Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "by-products" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Comparison of Methods For Ethylhexyl 4-Methoxycinnamate Acid Ester Oxidation In Water Medium
Autorzy:
Studziński, W.
Gackowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124606.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
EHMC
oxidation
by-products
GC-MS
Opis:
The aim of the studies was to compare an impact of oxidizing agents on degradation of ethylhexyl 4-methoxycinnamate acid (EHMC). The oxidation reaction was carried out in the presence of sodium hypochlorite, hydrogen peroxide and ozone with/without UV radiation. EHMC degradation and the analysis of products were performed using gas chromatograph coupled with a mass spectrometry detector. The most effective method of EHMC degradation turned out to be ozonation with participation of UV radiation. In this system, degradation proceeded most quickly and generated a small amount of by-products (2-propyl-1-pentanol; 4-metoxybenzaldehyde and Z-EHMC). Under the influence of sodium hypochlorite, numerous chloroorganic products were formed, which can cause secondary contamination of water. Application of appropriate oxidation processes can contribute to degradation of micropollutants and thus to improvement of water quality.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 204-210
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste Management Options for the Combustion by Products in the Context of the Retardation of Soil Resources’ Depletion
Autorzy:
Śliwka, M.
Pawul, M.
Kępys, W.
Pomykała, R.
Powiązania:
https://bibliotekanauki.pl/articles/124013.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
combustion by-products
fly ash
bottom ash
environment, biomass
phytotests, toxicity
Opis:
This paper presents the results of the preliminary experiments conducted on fly ash and bottom ash samples that were collected from a fluidised-bed boiler after biomass combustion. The purpose of the research was to determine potential possibilities of the introduction of such types of waste to soil, in accordance with the ecological engineering assumptions. The following physical and chemical properties of the analysed waste were determined: particle size distribution, pH, chemical composition, and leaching. The chemical properties of the tested power-generation waste were essentially different, depending on the time of waste sample collection from the installation, despite the fact that other identical sampling conditions were observed: the same installation, the same combustion process, and the same type of fuel. To determine the eco-toxicity of the tested waste samples, the vegetation experiments were conducted that allowed to evaluate the influence of the tested waste samples on selected test plant species. The tests concerned for example the influence of fly ash and bottom ash on such physiological processes as seed germination and plant growth (the growth of both roots and shoots). The experiments indicated certain options of the introduction of the tested waste into soil. However, due to a considerable changeability of the waste composition and structure that presented a risk of the introduction of undesired pollutants into soil, including heavy metals, such use would be possible upon previous regular evaluation of the waste’s physical, chemical, and eco-toxic properties.
Źródło:
Journal of Ecological Engineering; 2017, 18, 5; 216-225
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka problemów eksploatacji suw czaniec w latach 2009-2010
Characteristic of operating difficulties of wtp czaniec in the year 2009-2010
Autorzy:
Zimoch, I.
Kotlarczyk, B.
Nadolska, K.
Powiązania:
https://bibliotekanauki.pl/articles/399953.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
koagulacja
stacja uzdatniania wody
mętność
uboczne produkty dezynfekcji
coagulation
water treatment plant
turbidity
disinfection by-products
Opis:
SUW Czaniec opiera swą produkcję na zasobach wód górskich pobieranych ze zbiornika Czaniec, charakteryzujących się intensywną zmianą jakości w czasie ulew i topnienia śniegu. Spływy powierzchniowe, jaki i zwiększenie przepływu w korytach rzek i potoków skutkują napływem ładunku zanieczyszczeń do zbiornika w Czańcu, co powoduje takie zwiększenie mętności i barwy, iż układ technologiczny uzdatniania wody nie jest w stanie zatrzymać zanieczyszczeń w wymaganym stopniu. Zjawiska gwałtownych zmian jakości wody w źródle, nabrały w ostatnich latach na sile, czego bezpośrednim efektem są wymuszone postoje technologiczne SUW Czaniec. W artykule przedstawiono pełną charakterystykę warunków technologicznych eksploatacji SUW w zmiennych okolicznościach produkcji wody. Integralnym elementem opracowania jest ocena efektów technologicznych wraz z analizą ekonomiczną eksploatacji stacji.
Water production of WTP Czaniec is based on mountain water resources. The water intake is located at the Czaniec reservoir. During downpour and snow's melting raw water has intensive changed of quality. Increase of water colour and turbidity in Czaniec reservoir have resulted from the flood run-off in river- bed and stream as well as earth flow, hence in the technological system of water treatment arises difficulties of correct water purification. Te effect of rapid water changes in source increases at last year, witch are direct results of forced shutdowns of water production of WTP Czaniec. The article presents a full characterization of the technological conditions of service at varying circumstances WTP water production. An integral element of the study is to assess the effects of technology along with the economical analysis of the WTP operating.
Źródło:
Inżynieria Ekologiczna; 2011, 26; 257-268
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wody basenowej pływalni krytych oraz kąpielisk sezonowych z wykorzystaniem testu MICROTOX®
Qualitative assessment of water in indoor swimming pool and seasonal bathing resorts using MICROTOX® test
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/400114.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
uboczne produkty dezynfekcji
woda basenowa
biotest bakteryjny
klasyfikacja toksyczności
disinfection by-products
pool water
bacterial bioassays
toxicity classification
Opis:
Przeprowadzone badania miały na celu określenie wielkości efektu toksycznego na podstawie inhibicji bioluminescencji bakterii Aliivibrio fischeri wywołanej przez zanieczyszczenia obecne w próbkach wody basenowej. Wykorzystywanym narzędziem był test Microtox®. Szybkość z jaką uzyskuje się wyniki w tym bioteście pozwala na stosowanie go w stosunku do wielu toksykantów. Ponadto przeprowadzono pomiar absorbancji w nadfiolecie UV254, którego wartość stanowiła parametr zastępczy dla określenia udziału prekursorów ubocznych produktów dezynfekcji w próbkach. Część próbek charakteryzowała się wysokimi wartościami UV254, w przypadku próbki popłuczyn jednego z badanych obiegów wyniosła 144 m-1. Przedstawione w pracy badania jakości wód basenowych obiektów krytych i odkrytych, z zastosowaniem testu Microtox® pozwoliły na potwierdzenie wpływu takich czynników jak wymiana powietrza czy źródło zasilania obiegów basenowych na jakość wody. W ramach pracy określono, że zanieczyszczenia obecne w wodzie basenowej powoduje jej toksyczność wobec bakterii. Uzyskano niższe wartości toksyczności w przypadku kąpielisk sezonowych, niż w przypadku pływalni krytej. Natomiast nie stwierdzono zależności pomiędzy wysokimi wartościami absorbancji w nadfiolecie UV254 a podwyższoną toksycznością próbek wody. Przeprowadzona ocena toksykologiczna może stanowić przesiewowy test jakości wody basenowej. Istotnym jest by przed jego wykonaniem poddać kontroli zawartość chloru wolnego, ponieważ wysokie stężenia mogą przyczyniać się do uzyskiwania wartości inhibicji bioluminescencji w zakresie wartości dla wysokiej toksyczności.
The tests were to specify the toxic effect on the basis of Vibrio fischeri luminescence inhibition caused by chemical compounds present in pool water samples. The testing tool was Microtox®. This biotest produces quick results thus making it a comfortable tool for testing water for various toxicants. Furthermore, UV254 absorbance measure was carried out and its value was a proxy parameter for defining participation of precursors to disinfection by-products in the samples. Some of the samples had high UV254 values, one of them was 144 m 1. The Microtox® quality tests of indoor and outdoor swimming pool water presented in the paper proved impact of such factors like air exchange or supply of pool water circulation on water quality. Seasonal bathing waters had lower toxicity values. In the context of the work specifies that impurities in the water cause its toxicity. However, there was no relationship between high UV254 absorbance values and higher toxicity of the samples. The toxicological analysis may serve as a screening test of swimming pool water quality. It is of key importance to check the free chlorine value for a water sample. High chlorine concentration can cause higher bioluminescence inhibition values.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 210-216
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies