Tytuł:
The Use of PMU Data for Detecting and Monitoring Selected Electromagnetic Disturbances
Autorzy:
Barczentewicz, Szymon H.
Bień, Andrzej
Duda, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1844459.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical disturbances
phasor measurement unit
power quality
distribution system
Opis:
Power quality (PQ) monitoring is important for both the utilities and also the users of electric power. The most widespread measurement instrument used for PQ monitoring is the PQM (Power Quality Monitor) or PQA (Power Quality Analyzer). In this paper we propose the usage of PMU data for PQ parameters monitoring. We present a new methodology of PQ parameters monitoring and classification based on PMU data. The proposed methodology is tested with real measurements performed in distribution system using dedicated PMU system.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 4; 775-780
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of PV Inverters while Unintentional Islanding Using PMU
Autorzy:
Barczentewicz, Szymon Henryk
Lerch, Tomasz
Bień, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1844496.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical disturbances
phasor measurement unit
power quality
PV inverters
Opis:
Unintentional islanding detection is one the mandatory criterion that must be met by PV inverters before connecting them into the grid. Acceptable time for inverter for islanding detection is less than 2 seconds. In this paper voltage parameters after islanding occurrence and before turning off the inverter are analyzed. In order to simulate islanding state and perform measurements the testing system was build. Three different commercial PV inverters were tested. Measured signals were used to calculate voltage envelope, phasor, frequency and ROCOF. Collected data proved to be helpful to compere different inverters.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 3; 465-470
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fir Filters Compliant with the IEEE Standard for M Class PMU
Autorzy:
Duda, K.
Zieliński, T. P.
Powiązania:
https://bibliotekanauki.pl/articles/221798.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phasor estimation
Phasor Measurement Unit
FIR filter
cosine window
flat-top window
Opis:
In this paper it is shown that M class PMU (Phasor Measurement Unit) reference model for phasor estimation recommended by the IEEE Standard C37.118.1 with the Amendment 1 is not compliant with the Standard. The reference filter preserves only the limits for TVE (total vector error), and exceeds FE (frequency error) and RFE (rate of frequency error) limits. As a remedy we propose new filters for phasor estimation for M class PMU that are fully compliant with the Standard requirements. The proposed filters are designed: 1) by the window method; 2) as flat-top windows; or as 3) optimal min-max filters. The results for all Standard compliance tests are presented, confirming good performance of the proposed filters. The proposed filters are fixed at the nominal frequency, i.e. frequency tracking and adaptive filter tuning are not required, therefore they are well suited for application in lowcost popular PMUs.
Źródło:
Metrology and Measurement Systems; 2016, 23, 4; 623-636
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
Autorzy:
Arendarski, B.
Rabe, S.
Heineken, W.
Komarnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/140719.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
discrete Fourier transform (DFT)
dynamic phasor
measurement accuracy
phasor measurement unit (PMU)
power system
Opis:
Power systems that are highly loaded, especially by a stochastic supply of renew- ables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during au- tomated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 529--543
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A review of the importance of synchrophasor technology, smart grid, and applications
Autorzy:
Baba, Maveeya
Nor, Nursyarizal B.M.
Sheikh, Aman
Nowakowski, Grzegorz
Masood, Faisal
Rehman, Masood
Irfan, Muhammad
Arefin, Ahmed Amirul
Kumar, Rahul
Baba, A. Momin
Powiązania:
https://bibliotekanauki.pl/articles/2173713.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phasor measurement unit
PMU
micro-PMU
Global Positioning System
GPS
optimal PMU placement
smart grid
SG
jednostka pomiaru fazorów
mikro-PMU
globalny system pozycjonowania
optymalne rozmieszczenie PMU
sieć inteligentna
Opis:
The electrical network is a man-made complex network that makes it difficult to monitor and control the power system with traditional monitoring devices. Traditional devices have some limitations in real-time synchronization monitoring which leads to unwanted behavior and causes new challenges in the operation and control of the power systems. A Phasor measurement unit (PMU) is an advanced metering device that provides an accurate real-time and synchronized measurement of the voltage and current waveforms of the buses in which the PMU devices are directly connected in the grid station. The device is connected to the busbars of the power grid in the electrical distribution and transmission systems and provides time-synchronized measurement with the help of the Global Positioning System (GPS). However, the implementation and maintenance cost of the device is not bearable for the electrical utilities. Therefore, in recent work, many optimization approaches have been developed to overcome optimal placement of PMU problems to reduce the overall cost by providing complete electrical network observability with a minimal number of PMUs. This research paper reviews the importance of PMU for the modern electrical power system, the architecture of PMU, the differences between PMU, micro-PMU, SCADA, and smart grid (SG) relation with PMU, the sinusoidal waveform, and its phasor representation, and finally a list of PMU applications. The applications of PMU are widely involved in the operation of power systems ranging from power system control and monitor, distribution grid control, load shedding control and analyses, and state estimation which shows the importance of PMU for the modern world.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 6; art. no. e143826
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies