Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fault-arc" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
FEM analysis of magnetic field and forces in area ARC fault of autotransformer HV winding
Autorzy:
Koteras, D.
Powiązania:
https://bibliotekanauki.pl/articles/141136.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
3D magnetic field analysis
electrodynamic forces
mechanical stresses
electric arc fault in windings
Opis:
In this paper the electric arc fault in the high voltage winding turn of the power autotransformer has been investigated. 3D magnetic field distributions in the leakage domain and electrodynamic forces acting on high voltage winding have been calculated. Finite Element Method was used for the magnetic flux density simulation. The elctrodynamic force value under the fault exceed significantly the nominal mechanical stresses of the winding.
Źródło:
Archives of Electrical Engineering; 2014, 63, 4; 601-608
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems and counter measures of arc suppression coilin 10 kV distribution system
Autorzy:
Ni, Hui
Ding, Pei
Ma, Yunlong
Ai, Shaogui
Ma, Feiyue
Zhang, Qingping
Powiązania:
https://bibliotekanauki.pl/articles/141485.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arc suppression coil
capacitive current
artificial grounding fault test
neutral non-effective grounding system
Opis:
The arc suppression coil determines whether it can effectively extinguish the arc when it is grounded in the neutral non-effective grounding system. An artificial grounding test is an importantway to verify its performance. In this study, 13 substations with the 10 kV system in the Ningxia areawere selected and considered. Based on the artificial single-phase grounding test, the residual current, the compensation current and the off-resonance degree were measured in the arc suppression coil, and the performance of the arc suppression coil in the 10 kV system was verified. The experimental results show that the error of arc suppression coil automatic measurement is large, the off-resonance degree is large, the resistive component in the compensation current is excessive, the harmonic component exists in the compensating current and capacitive current. To solve these problems, this paper puts forward the corresponding countermeasures for reference.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 135-146
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies