Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "demagnetization" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Development of a technique for inductive measurement of laser-induced magnetization dynamics in thin films
Autorzy:
Ilit’, Tomáš
Valko, Pavol
Držík, Milan
Ušáková, Marianna
Šoka, Martin
Marton, Marian
Behúl, Miroslav
Vojs, Marian
Powiązania:
https://bibliotekanauki.pl/articles/220843.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser-induced demagnetization
pulsed inductive microwave magnetometry
ultrafast demagnetization detection
Opis:
We present the development of a technique for studying laser-induced magnetization dynamics, based on inductive measurement. The technique could provide a simple tool for studying laser-induced demagnetization in thin films and associated processes, such as Gilbert damping and magnetization precession. It was successfully tested using a nanosecond laser and NiZn ferrite samples and - after further development - itis expected to be useful for observation of ultra-fast demagnetization. The combination of optical excitation and inductive measurement enables to study laser-induced magnetization dynamics in both thin and several micrometre thick films and might be the key to a new principle of ultrafast broadband UV-IR pulse detection.
Źródło:
Metrology and Measurement Systems; 2019, 26, 3; 531-540
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetization dependent demagnetization characteristic of rare-earth permanent magnets
Autorzy:
Bavendiek, Gregor
Müller, Fabian
Sabirov, Jamshid
Hameyer, Kay
Powiązania:
https://bibliotekanauki.pl/articles/140527.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
demagnetization
magnetic hysteresis
magnetization processes
permanent magnets
Opis:
Accurate demagnetization modelling is mandatory for a reliable design of rare- earth permanent magnet applications, such as e.g. synchronous machines. The magnetization of rare-earth permanent magnets requires high magnetizing fields. For technical reasons, it is not always possible to completely and homogeneously achieve the required field strength during a pulse magnetization, due to stray fields or eddy currents. Not sufficiently magnetized magnets lose remanence as well as coercivity and the demagnetization characteristic becomes strongly nonlinear. It is state of the art to treat demagnetization curves as linear. This paper presents an approach to model the nonlinear demagnetization in dependence on the magnetization field strength. Measurements of magnetization dependent demagnetization characteristics of rare-earth permanent magnets are compared to an analytical model description. The physical meaning of the model parameters and the influence on them by incomplete magnetization are discussed for different rare-earth permanent magnet materials. Basically, the analytic function is able to map the occurring magnetization dependent demagnetization behavior. However, if the magnetization is incomplete, the model parameters have a strong nonlinear behavior and can only be partially attributed to physical effects. As a benefit the model can represent nonlinear demagnetization using a few parameters only. The original analytical model is from literature but has been adapted for the incomplete magnetization. The discussed effect is not sufficiently accurate modelled in literature. The sparse data in literature has been supplemented with additional pulsed-field magnetometer measurements.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 33-45
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of rotor’s cage resistance on demagnetization process in the line start permanent magnet synchronous motor
Autorzy:
Zawilak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/141077.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
demagnetization
falling out of step
permanent magnets
synchronous motor
Opis:
This paper deals with the finite element analysis of the demagnetization process of the line start permanent magnet synchronous motor. Special attention has been paid to demagnetization risk assessment after resynchronization during a short-term supply power outage. The current and torque waveforms have been determined assuming the difference depending initial rotor position angle. It has been demonstrated that the highest demagnetization risk occurs when resynchronization (motor reclosing) is performed when induced electromotive forces are in anti-phase to the supply voltage waveforms. The effect of cage winding resistance on the risk of demagnetization is examined and discussed.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 249-258
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance comparison of double stator permanent magnet machines
Autorzy:
Awah, Chukwuemeka Chijioke
Powiązania:
https://bibliotekanauki.pl/articles/2172793.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
demagnetization
double stator
induced voltage
losses
power and torque
Opis:
The electromagnetic and output performance characteristics of three (3) different types of double stator permanent magnet machines are quantitatively compared and presented in this study, in order to determine the most promising machine topology amongst the considered machine types, for potential practical applications(s). Two-dimensional (2D) and three-dimensional (3D) finite element analysis (FEA) methods are deployed in the computation of the performance metrics using ANSYS-MAXWELL software. The compared machines in this work are designated as: Machine 1, Machine 2 and Machine 3, respectively. The investigated machines have varying structural arrangements and two separate excitation sources. Machine 1 has its magnets situated in the outer stator with corresponding armature windings on both inner and outer stators. The magnets of Machine 2 are located in its inner stator while it has armature windings on both inner and outer stator parts. More so, Machine 3 is equipped with magnets in its inner and outer stators, though without armature windings on the inner stator section. The considered performance metrics include: inducedelectromotive force (induced-EMF), torque, power, demagnetization, losses and efficiency. The results show that the investigated Machine 3 has higher induced-EMF value and more sinusoidal electromotive force waveform than the other compared machines. Consequently, Machine 3 also has larger electromagnetic torque and power. Moreover, Machine 1 has the best flux-weakening potential, obtained from both the ratio of its maximum speed to base speed and the flux-weakening factor ( kp).
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 829--850
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measures to reduce the residual field and field gradient inside a magnetically shielded room by a factor of more than 10
Autorzy:
Voigt, J.
Knappe-Grüneberg, S.
Schnabel, A.
Körber, R.
Burghoff, M.
Powiązania:
https://bibliotekanauki.pl/articles/220358.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnetic shielding
magnetic shielded room
msr
residual field
residual field gradient
degaussing
demagnetization
Opis:
Very low residual magnetic field and field gradients are essential for a number of high resolution fundamental physical experiments and for further improvement of very sensitive magnetic measurement devices. The scope ranges from spin precession experiments, e.g. with 3He or neutrons, to biomagnetic measurements, like magnetoencephalograms, and to low field MR spectroscopy. One method of reducing environmental magnetic noise is to use a magnetically shielded room (MSR). Here, measures are demonstrated to improve residual field and field gradient inside a common MSR by a factor of more than 10 by a specific degaussing procedure, material selection of prefabricated parts and active shielding. The process is independent of the shielding factor and works also properly for heavily shielded rooms.
Źródło:
Metrology and Measurement Systems; 2013, 20, 2; 237-248
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimized design of a high-power-density PM-assisted synchronous reluctance machine with ferrite magnets for electric vehicles
Autorzy:
Liu, X.
Li, Y.
Liu, Z.
Ling, T.
Luo, Z.
Powiązania:
https://bibliotekanauki.pl/articles/140849.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
permanent magnet (PM)-assisted synchronous reluctance machine
ferrite magnet
demagnetization
mechanical strength
torque ripple
finite element analysis
Opis:
This paper proposes a permanent magnet (PM)-assisted synchronous reluctance machine (PMASynRM) using ferrite magnets with the same power density as rareearth PM synchronous motors employed in Toyota Prius 2010. A suitable rotor structure for high torque density and high power density is discussed with respect to the demagnetization of ferrite magnets, mechanical strength and torque ripple. Some electromagnetic characteristics including torque, output power, loss and efficiency are calculated by 2-D finite element analysis (FEA). The analysis results show that a high power density and high efficiency of PMASynRM are obtained by using ferrite magnets.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 279-293
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies