Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "control of power" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Influence of A/D quantization in an interpolated DFT based system of power control with a small delay
Autorzy:
Borkowski, J.
Kania, D.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221386.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaic system
frequency estimation
signal processing
A/D converter
control of power system
Opis:
Fast and accurate grid signal frequency estimation is a very important issue in the control of renewable energy systems. Important factors that influence the estimation accuracy include the A/D converter parameters in the inverter control system. This paper presents the influence of the number of A/D converter bits b, the phase shift of the grid signal relative to the time window, the width of the time window relative to the grid signal period (expressed as a cycle in range (CiR) parameter) and the number of N samples obtained in this window with the A/D converter on the developed estimation method results. An increase in the number b by 8 decreases the estimation error by approximately 256 times. The largest estimation error occurs when the signal module maximum is in the time window center (for small values of CiR) or when the signal value is zero in the time window center (for large values of CiR). In practical applications, the dominant component of the frequency estimation error is the error caused by the quantization noise, and its range is from approximately 8×10-10 to 6×10-4.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 423-432
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy balancing in modular multilevel converter systems
Autorzy:
Blaszczyk, P.
Koska, K.
Klimczak, P.
Powiązania:
https://bibliotekanauki.pl/articles/201814.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MMC
multilevel converters
energy balancing
control of power
electronic converters
konwerter
bilans energetyczny
sterowanie elektroniczne
konwerter mocy
Opis:
The modular multilevel converter (MMC) is a well-known solution for medium and high voltage high power converter systems. This paper deals with energy balancing of MMCs. The analysis includes multi-converter systems. In order to provide clear view, the MMC control system is divided into hierarchical levels. Details of control and balancing methods are discussed for each level separately. Finally, experimental results, based on multi-converter test setup, are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 685-694
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interpolated-DFT-Based Fast and Accurate Amplitude and Phase Estimation for the Control of Power
Autorzy:
Borkowski, J.
Kania, D.
Powiązania:
https://bibliotekanauki.pl/articles/221570.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control of power
grid signal
amplitude and phase estimation
renewable energy
interpolated DFT
maximum decay side-lobes windows
Opis:
Quality of energy produced in renewable energy systems has to be at the high level specified by respective standards and directives. One of the most important factors affecting quality is the estimation accuracy of grid signal parameters. This paper presents a method of a very fast and accurate amplitude and phase grid signal estimation using the Fast Fourier Transform procedure and maximum decay side-lobes windows. The most important features of the method are elimination of the impact associated with the conjugate’s component on the results and its straightforward implementation. Moreover, the measurement time is very short ‒ even far less than one period of the grid signal. The influence of harmonics on the results is reduced by using a bandpass pre-filter. Even using a 40 dB FIR pre-filter for the grid signal with THD ≈ 38%, SNR ≈ 53 dB and a 20‒30% slow decay exponential drift the maximum estimation errors in a real-time DSP system for 512 samples are approximately 1% for the amplitude and approximately 8.5・10‒2 rad for the phase, respectively. The errors are smaller by several orders of magnitude with using more accurate pre-filters.
Źródło:
Metrology and Measurement Systems; 2016, 23, 1; 13-26
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy-optimal current distribution in an electrical network – controlling by the differential or the integral systems
Autorzy:
Siwczyński, M.
Żaba, S.
Drwal, A.
Powiązania:
https://bibliotekanauki.pl/articles/201855.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
principle of minimum energy losses
optimal control
suboptimal control
power series
operators of multiple differentiation or integration
decomposition of a rational function
zasada minimalnych strat energii
optymalna kontrola
nieoptymalna kontrola
Opis:
In the complex RLC network, apart from the currents flows arising from the normal laws of Kirchhoff, other distributions of current, resulting from certain optimization criteria, may also be received. This paper is the development of research on distribution that meets the condition of the minimum energy losses within the network called energy-optimal distribution. Optimal distribution is not reachable itself, but in order to trigger it off, it is necessary to introduce the control system in current-dependent voltage sources vector, entered into a mesh set of a complex RLC network. For energy-optimal controlling, to obtain the control operator, the inversion of R(s) operator is required. It is the matrix operator and the dispersive operator (it depends on frequency). Inversion of such operators is inconvenient because it is algorithmically complicated. To avoid this the operator R(s) is replaced by the R’ operator which is a?matrix, but non-dispersive one (it does not depend on s). This type of control is called the suboptimal control. Therefore, it is important to make appropriate selection of the R’ operator and hence the suboptimal control. This article shows how to implement such control through the use of matrix operators of multiple differentiation or integration. The key aspect is the distribution of a single rational function H(s) in a series of ‘s’ or ‘s1’. The paper presents a new way of developing a given, stable rational transmittance with real coefficients in power series of ‘s/s1. The formulas to determine values of series coefficients (with ‘s/s1’) have been shown and the conditions for convergence of differential/integral operators given as series of ‘s/s1’ have been defined.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 3; 613-620
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies