Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cieplo" wg kryterium: Temat


Tytuł:
Heat transfer in falling film evaporators during the industrial process of apple juice concentrate production
Autorzy:
Cyklis, P.
Powiązania:
https://bibliotekanauki.pl/articles/240517.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
falling film evaporator
industrial
transport
ciepło
przemysł
Opis:
Falling film, shell-tube type evaporators are commonly used heat exchangers for the production of fruit juice concentrate. The main problem in the design of the exchanger is a reliable estimation of wall heat transfer coefficients for all effects in real operating conditions. Most literature sources for the overall heat transfer coefficients are based on laboratory measurements, where the tubes are usually short, no fouling exists and the flow rate is carefully adjusted. This paper shows the heat transfer estimated in real industrial operating conditions, compared to literature sources. Paper is based on the author’s own experience in designing and launching several evaporators for juice concentrate production into operation. As a summary, the design heat transfer coefficients are provided with relation to sugar content in juice concentrate.
Źródło:
Archives of Thermodynamics; 2018, 39, 3; 3-13
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste heat recovery from the air preparation room in a paint shop
Autorzy:
Adamkiewicz, Andrzej
Nikończuk, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/240142.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waste heat recovery
air compression
paint shop
ciepło odpadowe
sprężanie powietrza
lakiernia
Opis:
The policy of sustainable development seeks to improve energy efficiency of industrial equipment. Efforts to improve energy efficiency also apply to the paint shops, where the recovery of waste heat is sought. The main source of a large amount of low-temperature waste heat in the paint shop is the spray booth. The second place where a large amount of low temperature waste heat is released is the room where the compressed air is prepared. Low energy efficiency of air compressors requires a large electric power supply. As a result, the emitted large heat fluxes become waste energy of the technological process. Heat is equivalent to up to 93% of the electric power supplied in the air compression process. There are solutions for recovering heat from compressors coming from the oil cooling water, but then the waste heat from the cooling of the compressed air and from the electric motor is released into air in the room. A method for recovering low-temperature waste heat from the air preparation room by means of an air-source heat pump has been proposed. An energy balance of the air compression and dehumidification process for the paint shop was made. A Matlab’s built-in numerical model includes air compressor and dehumidifier, heat recovery and accumulation for the purposes of use in the spray booth. A simulation experiment was carried out on the effectiveness of heat recovery from the air preparation room. The use of combined energy management in paint shops was proposed.
Źródło:
Archives of Thermodynamics; 2019, 40, 3; 229-241
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Structure on Thermal Power of Cast-iron Heat Exchangers
Autorzy:
Mróz, M.
Orłowicz, A. W.
Tupaj, M.
Jacek-Burek, M.
Radoń, M.
Kawiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/382256.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
gray cast iron
thermal power
wymiennik ciepła
żeliwo szare
ciepło
Opis:
The objective of the study reported in this paper was to determine the effect of structure on thermal power of cast-iron heat exchangers which in this case were furnace chambers constituting the main component of household fireplace-based heating systems and known commonly as fireplace inserts. For the purpose of relevant tests, plate-shaped castings were prepared of gray iron with flake graphite in pearlitic matrix (the material used to date typically for fireplace inserts) as well as similar castings of gray cast iron with vermicular graphite in pearlitic, ferritic-pearlitic, and ferritic matrix. For all the cast iron variants of different structures (graphite precipitate shapes and matrix type), calorimetric measurements were carried out consisting in determining the heat power which is quantity representing the rate of heat transfer to the ambient environment. It has been found that the value of the observed heat power was affected by both the shape of graphite precipitates and the type of alloy matrix. Higher thermal power values characterize plate castings of gray iron with vermicular graphite compared to plates cast of the flake graphite gray iron. In case of plates made of gray cast iron with vermicular graphite, the highest values of thermal power were observed for castings made of iron with ferritic matrix.
Źródło:
Archives of Foundry Engineering; 2020, 20, 1; 27-30
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie ciepła ze spalin wylotowych z kotła w bloku energetycznym klasy 900 MW
The use of heat recovered from boiler flue gases in a 900 MW class power plant
Autorzy:
Wołowicz, M.
Milewski, J.
Bujalski, W.
Lewandowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/173055.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
spaliny
blok energetyczny
ciepło ze spalin
exhaust
power unit
heat from exhaust
Opis:
W artykule przedstawiona została koncepcja wykorzystania ciepła ze spalin wylotowych z kotła do podgrzewu wody zasilającej i powietrza dla nadkrytycznego bloku węglowego. W celu przeprowadzenia analizy zbudowany został model bloku pracującego w zmienionych warunkach (off design) oraz wygenerowane zostały jego charakterystyki. Przedstawiono informacje na temat zaproponowanej koncepcji umieszczenia dodatkowego wymiennika w schemacie cieplnoprzepływowym rozpatrywanego bloku. Omówiona została również koncepcja wykorzystania ciepła ze spalin do podgrzewu powietrza wlotowego do kotła i na podstawie obliczeń zaproponowane zostały parametry takiego układu.
The paper presents the concept of using heat recovered from flue gases to heat up feedwater and inlet air in supercritical coal-fired unit. This concept has been developed for the reference condensing unit of 900 MW – class. In order to enable the analyse the model of such unit was build and its characteristics were generated using the off design mode. The concept of an additional heat exchanger and its place in the unit scheme was provided. Also the concept of using heat recovered from flue gases to heat up the intake air to the boiler was discussed. Based on calculations the parameters of such system were proposed.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 101-108
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Superconductivity of MgB2 composited with Mg-Zn alloys
Nadprzewodnictwo kompozytów MgB2 - stop Mg-Zn
Autorzy:
Kawabata, T.
Namiki, T.
Matsuda, K.
Tokai, D.
Murakami, S.
Nishimura, K.
Powiązania:
https://bibliotekanauki.pl/articles/352713.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
composite materials
magnesium alloy
specific heat
MgB2
materiały kompozytowe
stop magnezu
ciepło
Opis:
The three-dimensional penetration method combined with semi-solid casting was used to fabricate metal-powder composite superconducting materials of MgB2 with magnesium alloys: MgB2/Mg - xwt% Zn (x = 1, 3, 6, 9). X-ray diffraction measurements indicated predominant peak patterns of MgB2 and a host alloy. Measured electrical resistivity (ρ) versus temperature showed a clear signal of superconducting transition at about 34 K for all the samples cut out from the composites. External field (H) dependence of ρ(T,H) provided upper critical field of about 5 T. A volume fraction of the superconducting state of the sample estimated from a low external field part of magnetization was almost the same as the nominal ratio of MgB2 powder against the host material. A magnetic hysteresis loop observed at 5 K suggested that an addition of Zn element to magnesium host-matrix little changed the critical current density (Jc). A comparison of the present results with the previous ones of MgB2/Mg-Al-Zn systems confirmed that simultaneously doped Al and Zn were necessary to enhance Jc. Specific heat measurements of the sample with an external field showed that the bulk superconductivity of MgB2 was well conserved in the composites.
Metodę trójwymiarowego zagęszczania w połączeniu z odlewaniem w stanie stało-ciekłym użyto do wytworzenia kompozytowych materiałów nadprzewodzących proszku MgB2 ze stopami magnezu MgB2/Mg - x %.wag Zn (x = 1, 3, 6, 9). Rentgenowskie pomiary dyfrakcyjne wykazały obecność wyraźnych pików od MgB2 i osnowy. Oporność elektryczna (ρ) mierzona w zależności od temperatury zawierała wyraźny sygnał przejścia nadprzewodzącego około 34 K dla wszystkich próbek wyciętych z kompozytów. Zależność ρ(T, H) od zewnętrznego pola (H) pokazała górna krytyczna wartość pola 5 T. Udział objętościowy próbki w stanie nadprzewodzącym oszacowany z niskiej części zewnętrznego pola magnetyzacji był prawie taki sam jak stosunek nominalnej zawartości proszku MgB2 do materiału osnowy. Pętla histerezy magnetycznej obserwowana przy 5 K sugeruje, ze dodatek Zn do osnowy magnezowej niewiele zmienia gęstość prądu krytycznego (Jc). Porównanie obecnych wyników z wcześniej uzyskanymi dla układów MgB2/Mg-Al-Zn potwierdziło, ze do zwiększenia Jc konieczne jest jednoczesne domieszkowane Al i Zn. Pomiary ciepła właściwego próbki w zewnętrznym polu wykazały, ze nadprzewodnictwo MgB2 zostało dobrze zachowane w kompozytach.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 315-319
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical analysis of temperature rising for chilled water in the long distance transport pipelines in coal mine
Analiza teoretyczna wzrostu temperatur ochłodzonej wody w transporcie rurociągami na duże odległości w kopalniach węgla
Autorzy:
Yudong, Qi
Weimin, Cheng
Song, Xin
Powiązania:
https://bibliotekanauki.pl/articles/218958.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wymiana ciepła
ciepło tarcia
model
analiza teoretyczna
heat transfer
friction heat
theoretical analysis
Opis:
In order to provide sufficient cooling capacity for working and heading faces of the coal mine, chilled water is often transported a long distance along pipelines in deep mine, which inevitably results in its temperature rising owing to heat transfer through pipe wall and the friction heat for flow resistance. Through theoretical models for temperature increasing of the chilled water were built. It is pointed out that the temperature rising of the chilled water should be considered as a result of the synergy effects of the heat transfer and the friction heat, but theoretical analysis shows that within engineering permitting error range, the temperature increasing can be regarded as the sum caused by heat transfer and fraction heat respectively, and the calculation is simplified. The calculation analysis of the above two methods was made by taking two type of pipe whose diameters are De273 × 7 mm and De377 × 10 mm, with 15 km length in coal mine as an example, which shows that the error between the two methods is not over 0.04°C within the allowable error range. Aims at the commonly used chilled water diameter pipe, it is proposed that if the specific frictional head loss is limited between 100 Pa/m and 400 Pa/m, the proportion of the frictional temperature rising is about 24%~81% of the total, and it will increase with high flow velocity and the thin of the pipe. As a result, the friction temperature rising must not be ignored and should be paid enough attention in calculation of the chilled water temperature rising along pipe.
W celu zapewnienia odpowiedniego chłodzenia dla urządzeń górniczych wykorzystywanych do prac wydobywczych i urządzeń do drążenia tuneli w kopalni konieczny jest transport ochłodzonej wody rurociągami, nierzadko na znaczne odległości w obrębie kopalni podziemnej. Transport rurociągami nieuchronnie prowadzi do wzrostu temperatury wody wskutek wymiany ciepła poprzez ścianki rurociągu i wskutek tarcia związanego z oporem przepływu. Opracowane zostały modele teoretyczne wzrostu temperatury wody ochładzanej; na ich podstawie wskazano, że wzrost temperatury wody rozpatrywać należy jako oddziaływanie efektu synergii pomiędzy wymianą ciepła i ciepłem tarcia. Analiza teoretyczna wykazuje jednak, że przy poziomie błędu dopuszczalnego w praktyce inżynierskiej, wzrost temperatury wody traktować można jako zwykłą sumę wpływu wymiany ciepła i ciepła tarcia, tym samym znacznie upraszczając procedurę obliczeniową. Weryfikację wyników obliczeń otrzymanych w oparciu o dwie wymienione metody prze-prowadzono poprzez zbadanie przepływu wody w kopalni węgla, rurociągiem o długości 15 km złożonym z dwóch rodzajów rur, o wymiarach De 273 × 7 mm i De 377 × 10 mm. Wykazano, że różnica wyników uzyskanych dla obydwu metod nie przekraczała 0.04°C, przy założonym dopuszczalnym poziomie błędu. W odniesieniu do typowych rodzajów rur używanych do przesyłania wody ochłodzonej proponuje się ograniczenie dopuszczalnego spadku ciśnienia w przewodzie w granicach 100 Pa/m-400 Pa/m. Udział wzrostu temperatury wskutek oddziaływania sił tarcia waha się w granicach 24%-81% i rośnie wraz ze wzrostem prędkości przepływu i ze zmniejszaniem grubości ścianek rury. Jest więc rzeczą oczywistą, że wzrost temperatury wody wskutek oddziaływania sił tarcia nie może być pomijany i winien zostać odpowiednio uwzględniony przy obliczeniach wzrostu temperatury wody w rurociągu.
Źródło:
Archives of Mining Sciences; 2019, 64, 4; 785-796
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simplified isoperibol calorimetry for thermal testing of dielectric and conducting materials
Autorzy:
Moroń, L.
Żyłka, P.
Powiązania:
https://bibliotekanauki.pl/articles/141344.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kalorymetr
korekcja
chłodzenie
wymiana ciepła
ciepło właściwe
calorimeter
correction
cooling
heat transfer
specific heat
Opis:
A simplified isoperibol calorimetry method for measuring specific heat in solids is described. Taking advantage of the classical Nernst dependency the specific heat is calculated from time-domain temperature curves registered for a sample forced heating and natural cooling phase. In order to improve accuracy of the measurements a correction factor, taking into account the heat transferred to the surrounding, is introduced along with a procedure of statistical elimination of unavoidable measurement deviations. The method is implemented in a simple and straightforward measuring system involving no vacuum calorimeter. The method is applicable for quick and routine specific heat measurements performed on small solid dielectric or metallic specimens at near-room temperature. Test results of various materials used commonly in electrical engineering are demonstrated and discussed as well as comparison to drop calorimetry and differential scanning calorimetry reference measurements is included. The overall repeatability of the test method and the simplified apparatus is estimated as not worse than 2.6%.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 95-104
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy analysis of the Szewalski cycle with a waste heat recovery system
Autorzy:
Kowalczyk, T.
Ziółkowski, P.
Badur, J.
Powiązania:
https://bibliotekanauki.pl/articles/240278.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Szewalski cycle
binary vapour cycle
exergy analysis
waste heat
idea Szewalskiego
analiza egzergii
ciepło odpadowe
Opis:
The conversion of a waste heat energy to electricity is now becoming one of the key points to improve the energy efficiency in a process engineering. However, large losses of a low-temperature thermal energy are also present in power engineering. One of such sources of waste heat in power plants are exhaust gases at the outlet of boilers. Through usage of a waste heat regeneration system it is possible to attain a heat rate of approximately 200 MWth, under about 90°C, for a supercritical power block of 900 MWel fuelled by a lignite. In the article, we propose to use the waste heat to improve thermal efficiency of the Szewalski binary vapour cycle. The Szewalski binary vapour cycle provides steam as the working fluid in a high temperature part of the cycle, while another fluid – organic working fluid – as the working substance substituting conventional steam over the temperature range represented by the low pressure steam expansion. In order to define in detail the efficiency of energy conversion at various stages of the proposed cycle the exergy analysis was performed. The steam cycle for reference conditions, the Szewalski binary vapour cycle as well as the Szewalski hierarchic vapour cycle cooperating with a system of waste heat recovery have been comprised.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 25-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
First principles calculations of thermodynamic properties of ZrB2
Autorzy:
Wani, T. A.
Das, B. K.
Powiązania:
https://bibliotekanauki.pl/articles/240687.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
TMB2
thermal expansion
Gruneisen parameter
debye temperature
specific heat
ekspandowanie termiczne
ciepło właściwe
rozszerzalność termiczna
Opis:
The thermodynamic properties, which are the important bulk properties for solids, have been investigated for ZrB2 under pressure through the quasi harmonic Debye model. The dependences of thermal expansion, Gruneisen parameter, Debye temperature and specific heat on pressure P are successfully obtained. The obtained results are in a good agreement with the available experimental and other theoretical data.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 113--124
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Organic Rankine cycle for residual heat to power conversion in natural gas compressor station. Part II: Plant simulation and optimisation study
Organiczny obieg rankina do produkcji energii elektrycznej z ciepła odpadowego w tłoczni gazu. Część II: Symulacja i optymalizacja instalacji
Autorzy:
Chaczykowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/219348.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gazociąg
tłocznia gazu
ciepło odpadowe
odzysk energii
optymalizacja
gas pipeline
compressor station
waste heat
energy recovery
optimization algorithms
Opis:
After having described the models for the organic Rankine cycle (ORC) equipment in the first part of this paper, this second part provides an example that demonstrates the performance of different ORC systems in the energy recovery application in a gas compressor station. The application shows certain specific characteristics, i.e. relatively large scale of the system, high exhaust gas temperature, low ambient temperature operation, and incorporation of an air-cooled condenser, as an effect of the localization in a compressor station plant. Screening of 17 organic fluids, mostly alkanes, was carried out and resulted in a selection of best performing fluids for each cycle configuration, among which benzene, acetone and heptane showed highest energy recovery potential in supercritical cycles, while benzene, toluene and cyclohexane in subcritical cycles. Calculation results indicate that a maximum of 10.4 MW of shaft power can be obtained from the exhaust gases of a 25 MW compressor driver by the use of benzene as a working fluid in the supercritical cycle with heat recuperation. In relation to the particular transmission system analysed in the study, it appears that the regenerative subcritical cycle with toluene as a working fluid presents the best thermodynamic characteristics, however, require some attention insofar as operational conditions are concerned.
W pierwszej części artykułu przedstawiono modele matematyczne elementów siłowni ORC, natomiast niniejsza, druga część artykułu, zawiera przykład ilustrujący efektywność różnych systemów ORC w instalacji odzysku ciepła w stacji przetłocznej. W wyniku lokalizacji w stacji przetłocznej, instalacja wyróżnia się pewnymi charakterystycznymi cechami, takimi jak stosunkowo duża wielkość systemu, praca przy niskich temperaturach otoczenia, zastosowanie skraplacza chłodzonego powietrzem. Obliczenia optymalizacyjne przeprowadzone dla 17 płynów pozwoliły na wybór odpowiednich czynników roboczych dla każdej konfiguracji obiegu, wśród których benzen, aceton i heptan wykazały najwyższą możliwość odzysku energii w obiegach nadkrytycznych, podczas gdy benzen, toluen i cykloheksan w obiegach podkrytycznych. Wyniki obliczeń pokazują, że dysponując strumieniem spalin z turbiny gazowej o mocy 25 MW, za pomocą benzenu jako czynnika roboczego, można uzyskać w obiegu nadkrytycznym z regeneracją ciepła maksymalną moc mechaniczną na wale turbiny wynoszącą 10,4 MW.W odniesieniu do systemu przesyłowego analizowanego w tej pracy najlepszym wariantem siłowni ORC z punktu widzenia charakterystyki termodynamicznej jest obieg nadkrytyczny z regeneracją ciepła przy zastosowaniu toluenu jako czynnika roboczego, jednak jego stosowanie mogłoby powodować problemy eksploatacyjne podczas użytkowania instalacji.
Źródło:
Archives of Mining Sciences; 2016, 61, 2; 259-274
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of an impulse and a reaction turbine stage for an ORC power plant
Autorzy:
Zaniewski, Dawid
Klimaszewski, Piotr
Witanowski, Łukasz
Jędzejewski, Łukasz
Klonowicz, Piotr
Lampart, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/240056.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CFD
waste heat recovery
steam turbine
organic Rankine cycle
ciepło odpadowe
odzysk ciepła
ORC
organiczny cykl Rankine'a
Opis:
Turbine stages can be divided into two types: impulse stages and reaction stages. The advantages of one type over the second one are generally known based on the basic physics of turbine stage. In this paper these differences between mentioned two types of turbines were indicated on the example of single stage turbines dedicated to work in organic Rankine cycle (ORC) power systems. The turbines for two ORC cases were analysed: the plant generating up to 30 kW and up to 300 kW of net electric power, respectively. Mentioned ORC systems operate with different working fluids: DMC (dimethyl carbonate) for the 30 kW power plant and MM (hexamethyldisiloxane) for the 300 kW power plant. The turbines were compared according to three major issues: thermodynamic and aerodynamic performance, mechanical and manufacturing aspects. The analysis was performed by means of the 0D turbomachinery theory and 3D computational aerodynamic calculations. As a result of this analysis, the paper indicates conclusions which type of turbine is a recommended choice to use in ORC systems taking into account the features of these systems.
Źródło:
Archives of Thermodynamics; 2019, 40, 3; 137-157
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Organic Rankine cycle for residual heat to power conversion in natural gas compressor station. Part I: Modelling and optimisation framework
Organiczny obieg Rankina do produkcji energii elektrycznej z ciepła odpadowego w tłoczni gazu. Część I: Model matematyczny systemu i sformułowanie zadania optymalizacji
Autorzy:
Chaczykowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/219914.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gazociąg
tłocznia gazu
ciepło odpadowe
odzysk energii
optymalizacja
gas pipeline
compressor station
waste heat
energy recovery
optimization algorithms
Opis:
Basic organic Rankine cycle (ORC), and two variants of regenerative ORC have been considered for the recovery of exhaust heat from natural gas compressor station. The modelling framework for ORC systems has been presented and the optimisation of the systems was carried out with turbine power output as the variable to be maximized. The determination of ORC system design parameters was accomplished by means of the genetic algorithm. The study was aimed at estimating the thermodynamic potential of different ORC configurations with several working fluids employed. The first part of this paper describes the ORC equipment models which are employed to build a NLP formulation to tackle design problems representative for waste energy recovery on gas turbines driving natural gas pipeline compressors.
W artykule analizowano organiczny obieg Rankine’a (ORC) w wariancie podstawowym i z regeneracją ciepła, w celu odzyskiwania ciepła odpadowego w tłoczni gazu. Przedstawiono model matematyczny elementów systemu oraz sformułowano problem optymalizacji systemu, przyjmując maksymalizację mocy elektrycznej produkowanej w instalacji odzysku ciepła jako funkcję celu. Zadanie optymalizacji rozwiązano z wykorzystaniem algorytmu genetycznego. Celem badań było oszacowanie potencjalnych możliwości produkcji energii elektrycznej przy różnych konfiguracjach układu ORC oraz przy różnych czynnikach roboczych. W pierwszej części pracy przedstawiono uproszczony model matematyczny obiegu ORC, który posłużył do sformułowania zadania programowania nieliniowego, pozwalającego na rozwiązywanie typowych problemów projektowych instalacji odzysku ciepła z turbin gazowych w stacjach przetłocznych gazu.
Źródło:
Archives of Mining Sciences; 2016, 61, 2; 245-258
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bidirectionally stretched flow of Jeffrey liquid with nanoparticles, Rosseland radiation and variable thermal conductivity
Autorzy:
Archana, M.
Gireesha, B. J.
Rashidi, M. M.
Prasannakumara, B. C.
Gorla, R. S. R.
Powiązania:
https://bibliotekanauki.pl/articles/240409.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat mass transfer
jeffrey nanofluid
variable thermal conductivity
rosseland approximation
suction
ciepło
masa
zmienna przewodność cieplna
aproksymacja
ssanie
Opis:
Heat and mass transfer stretched flow of an incompressible, electrically conducting Jeffrey fluid has been studied numerically. Nanoparticles are suspended in the base fluid and it has many applications such as cooling of engines, thermal absorption systems, lubricants fuel cell, nanodrug delivery system and so on. Temperature dependent variable thermal conductivity with Rosseland approximation is taken into account and suction effect is employed in the boundary conditions. The governing partial differential equations are first transformed into set of ordinary differential equations using selected similarity transformations, which are then solved numerically using Runge-Kutta-Felhberg fourth-fifth order method along with shooting technique. The flow, heat and mass transfer characteristics with local Nusselt number for various physical parameters are presented graphically and a detailed discussion regarding the effect of flow parameters on velocity and temperature profiles are provided. It is found that, increase of variable thermal conductivity, radiation, Brownian motion and thermophoresis parameter increases the rate of heat transfer. Local Nusselt number has been computed for various parameters and it is observed that, in the presence of variable thermal conductivity and Rosseland approximation, heat transfer characteristics are higher as compared to the constant thermal conductivity and linear thermal radiation.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 33--57
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Thermal Analysis Tests Results in the Numerical Simulations of Continuous Casting Process
Zastosowanie wyników badań analizy termicznej w obliczeniach numerycznych procesów odlewania stali
Autorzy:
Kargul, T.
Wielgosz, E
Falkus, J.
Powiązania:
https://bibliotekanauki.pl/articles/353992.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal analysis of steel
specific heat
enthalpy of phase transitions
steel
analiza termiczna stali
ciepło właściwe
entalpia przemian fazowych
stal
Opis:
Measurement of thermophysical properties of steel is possible by using different thermal analysis techniques. In the field of metallurgy the most relevant methods are Differential Thermal Analysis (DTA) and Differential Scanning Calorimetry (DSC). The paper presents the results of thermophysical properties which are necessary to carry out numerical simulation of continuous casting of steel. The study was performed for two steel grades S320GD and S235JR. The main aim of the research was to determine the dependence of specific heat on temperature. On the basis of obtained results the thermal effects of phase transformations and characteristic transition temperatures were also identified. Both the specific heat of steel and thermal effects of phase transformations are included in the Fourier-Kirchhoff equation, as the material properties necessary to obtain the numerical solution. The paper presents the research methodology, analysis of results and method of determining the specific heat of steel based on the results of DSC analysis.
Pomiar właściwości termofizycznych stali możliwy jest dzięki wykorzystaniu różnych technik analizy termicznej. W metalurgii najszersze zastosowanie znalazły różnicowa analiza termiczna (DTA) oraz różnicowa kalorymetria skaningowa (DSC). W pracy przedstawiono wyniki badań właściwości termofizycznych koniecznych do przeprowadzenia symulacji numerycznej procesu ciągłego odlewania stali. Badania wykonano dla dwóch gatunków stali S320GD i S235JR. Głównym celem badań było wyznaczenie funkcyjnej zależności ciepła właściwego analizowanych gatunków stali od temperatury. Na podstawie przeprowadzonych badań określono również efekty cieplne przemian fazowych oraz charakterystyczne temperatury przemian. Zarówno ciepło właściwe stali jak i efekty cieplne przemian fazowych wchodzą w skład równania Fouriera-Kirchhoffa, jako właściwości materiałowe konieczne do uzyskania rozwiązania numerycznego. W pracy przedstawiono metodykę badań, analizę uzyskanych wyników oraz sposób wyznaczania ciepła właściwego stali w oparciu wyniki analizy DSC.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 221-225
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Heat Capacity and Resistance to Cyclic Oxidation of Nickel Superalloys
Autorzy:
Przeliorz, R.
Binczyk, F.
Gradoń, P.
Góral, M.
Mikuszewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/381534.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
foundry technology
nickel superalloys
heat resistance
DSC calorimeter
heat capacity
technologie odlewnicze
nadstop niklu
odporność na ciepło
DSC kalorymetru
pojemność cieplna
Opis:
Paper presents the results of evaluation of heat resistance and specific heat capacity of MAR-M-200, MAR-M-247 and Rene 80 nickel superalloys. Heat resistance was evaluated using cyclic method. Every cycle included heating in 1100°C for 23 hours and cooling for 1hour in air. Microstructure of the scale was observed using electron microscope. Specific heat capacity was measured using DSC calorimeter. It was found that under conditions of cyclically changing temperature alloy MAR-M-247 exhibits highest heat resistance. Formed oxide scale is heterophasic mixture of alloying elements, under which an internal oxidation zone was present. MAR-M-200 alloy has higher specific heat capacity compared to MAR-M-247. For tested alloys in the temperature range from 550°C to 800°C precipitation processes (γ′, γ′′) are probably occurring, resulting in a sudden increase in the observed heat capacity.
Źródło:
Archives of Foundry Engineering; 2014, 14, 3; 67-70
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies