Tytuł:
Surface Modification of Self-Consolidated Microporous Ti Implant Compacts Fabricated by Electro-Discharge-Sintering in Air
Autorzy:
Jo, Y. J.
Yoon, Y. H.
Kim, Y. H.
Chang, S. Y.
Kim, J. Y.
Lee, Y. K.
Van Tyne, C. J.
Lee, W. H.
Powiązania:
https://bibliotekanauki.pl/articles/356790.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
titanium
implant
porous
sintering
X-ray photoelectron spectroscopy (XPS)
Opis:
A single pulse of 0.75-2.0 kJ/0.7g of atomized spherical Ti powders from 300 mF capacitor was applied to produce a microporous Ti implant compact by electro-discharge-sintering (EDS). A solid core in the middle of the compact surrounded by a microporous layer was found. X-ray photoelectron spectroscopy was employed to study the surface characteristics of the EDS Ti compact and it revealed that Ti, C and O were the main constituents on the surface with a smaller amount of N. The surface was lightly oxidized and was primarily in the form of TiO2 resulting from the air oxidation during EDS processing. The lightly oxidized surface of the EDS compact also exhibited Ti nitrides such as TiN and TiON, which revealed that the reaction between air constituents and the Ti powders even in times as short as 128 msec.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2B; 1287-1291
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Properties of Ca65-xMg17.5Zn17.5+x (x = 0, 2.5, 5) Alloys
Autorzy:
Babilas, R.
Wojciechowski, P.
Bajorek, A.
Sakiewicz, P.
Cesarz-Andraczke, K.
Powiązania:
https://bibliotekanauki.pl/articles/352466.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ca-based alloys
corrosion
hydrogen evolution
X-ray photoelectron spectroscopy
Opis:
The aim of the paper is to study the effect of zinc addition on the corrosion behavior of Ca65-xMg17.5Zn17.5+x(x = 0, 2.5, 5 at.%) alloys in simulated physiological fluids at 37°C. The electrochemical measurements allowed to determine a corrosion potential, which showed a positive shift from –1.60 V for Ca65Mg17.5Zn17.5 alloy to –1.58 V for Ca60Mg17.5Zn22.5 alloy, adequately. The more significant decrease of hydrogen evolution was noticed for Ca60Mg17.5Zn22.5 alloy (22.4 ml/cm2) than for Ca62.5Mg17.5Zn20 and Ca65Mg17.5Zn17.5 samples (29.9 ml/cm2 and 46.4 ml/cm2), consequently. The corrosion products after immersion tests in Ringer’s solution during 1 h were identified by X-ray diffraction and X-ray photoelectron spectroscopy as calcium, magnesium oxides, carbonates, hydroxides and calcium hydrate.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 3; 1033-1040
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multi-analytical approach for the analysis of cation distribution in a aluminoceladonite structure
Autorzy:
Kądziołka-Gaweł, Mariola
Dulski, Mateusz
Czaja, Maria
Krzykawski, Tomasz
Szubka, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2172615.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aluminoceladonite
ions position characterization isomorphic substitutions
Fe bearing phyllosilicates
X-ray photoelectron spectroscopy
Mössbauer spectroscopy
Raman spectroscopy
glinokrzemiany
krzemiany warstwowe
rentgenowska spektrometria fotoelektronów
XPS
spektroskopia mössabuerowska
spektroskopia Ramana
Opis:
In this paper cation arrangement in two samples of aluminoceladonite, emerald green and dark-green were studied by Mössbauer, Raman and X-ray photoelectron spectroscopies. The X-ray photoelectron spectroscopy (XPS) spectra obtained in the region of the Si2p, Al2p, Fe2p, K2p, and O1s core levels provided information, for the first time highlighting a route to identify the position of Si, Al, K, and Fe cations in a structure of layered silicates. The XPS analysis showed the presence of Al in tetrahedral and octahedral coordination while the K2p line indicated the possibility of K+ substitution by other cations in interlayer sites. Mössbauer spectroscopy provided information about crystal chemistry with respect to the local electronic and geometric environment around the Fe atom and to distortions of the polyhedra. It turned out that iron was located mostly in the cis-octahedra position wherein about 75% of iron appeared in the form of Fe3+. The most preferred cation combinations around Fe corresponded to 3Fe3+ ions and MgFe2+Fe3+/2MgFe3+. Raman spectroscopy illustrated aluminium substitution in silicon and iron positions wherein the concentration of the aluminium determined the degree of structural distortion within the layered system. These isomorphic substitutions implied a typical band arrangement in the hydroxyl region, which has not been observed in celadonites so far.
Źródło:
Acta Geologica Polonica; 2022, 72, 3; 353--368
0001-5709
Pojawia się w:
Acta Geologica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physicochemical and electrochemical properties of AISI 316L stainless steel used for implants in human urinary system
Ocena własności fizykochemicznych i elektrochemicznych stali AISI 316L stosowanej na implanty w urologii
Autorzy:
Walke, W.
Przondziono, J.
Powiązania:
https://bibliotekanauki.pl/articles/351228.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
electrochemical impedance spectroscopy (EIS)
X-ray photoelectron spectroscopy (XPS)
scanning electron microscopy (SEM)
austenityczna stal nierdzewna AISI 316L
elektrochemiczna spektroskopia impedancyjna EIS
rentgenowska spektroskopia fotoelektronów XPS
skaningowa mikroskopia elektronowa (SEM)
Opis:
The main purpose of this study was to evaluate physicochemical and electrochemical properties of AISI 316L stainless steel with modified surface, used for implants in human urinary system. In order to simulate conditions, which occur in the tissue environment of the urinary system, the test pieces were exposed in a urinary solution at temperature of T=37 ±1ºC, for a period of 30 days. Evaluation of physicochemical properties of biomaterial was made on the basis of surface chemical analysis (XPS). To evaluate the effects which occur on the surface of the examined steel, Electrochemical Impedance Spectroscopy (EIS) method was also employed. Analysis of test results shows favourable influence of the suggested surface treatment of AISI 316L stainless steel. Samples having electrolytically polished and chemically passivated surface featured the best physicochemical and electrochemical characteristics.
Podstawowym kryterium przydatności biomateriału metalowego na implanty urologiczne (stenty urologiczne) jest biokompatybilność. Jest ona w głównej mierze związana z własnościami fizykochemicznymi powierzchni implantu, które powinny być dostosowane do cech środowiska tkanek układu moczowego człowieka. W celu poprawy biokompatybilności stali Cr-Ni-Mo ustalono warunki wytwarzania warstw pasywnych na jej powierzchni. Wytworzenie warstwy pasywnej obejmowało etap polerowania elektrolitycznego i pasywowania. Taki sposób obróbki powierzchniowej zapewnił chropowatość Ra < 0,16 μm wymaganą dla tego rodzaju implantów. W pracy tej szczególną uwagę skoncentrowano na analizie długotrwałego oddziaływania środowiska sztucznego moczu na własności fizykochemiczne wytypowanej stali. Zasadniczym celem pracy była ocena własnosci fizykochemicznych i elektrochemicznych stali AISI 316L o modyfikowanej powierzchni stosowanej na implanty w układzie moczowym człowieka. W celu zasymulowania warunków występujących w środowisku tkankowym układu moczowego próbki poddawano ekspozycji w roztworze sztucznego moczu o temperaturze T=37±1ºC przez okres 30 dni. O przydatności zaproponowanej warstwy pasywnej do uszlachetniania powierzchni stali w znacznym stopniu decyduje jej skład chemiczny. Dlatego w pracy wykonano badania składu chemicznego metodą spektroskopii fotoelektronów (XPS), z użyciem wielofunkcyjnego spektrometru elektronów PHI 5700/660 firmy Physical Electronics, podczas których zidentyfikowano i wyznaczono stężenia atomowe pierwiastków w badanych warstwach pasywnych. Dla próbek przeprowadzono pomiar widma fotoelektronów w szerokim zakresie energii wiązania od 0÷1400 eV oraz dokładne pomiary linii widmowych poszczególnych pierwiastków składowych z warstwy powierzchniowej. Dla oceny zjawisk zachodzacych na powierzchni badanej stali zastosowano również metodę elektrochemicznej spektroskopii impedancyjnej (EIS). Pomiary przeprowadzono z wykorzystaniem systemu pomiarowego AutoLab PGSTAT 302N wyposażonego w moduł FRA2 (Frequency Response Analyser). Badania przeprowadzono w alternatywnym roztworze symulującym środowisko moczu człowieka. Zastosowana w pracy mikroskopia skaningowa pozwoliła na ocene stanu powierzchni stali AISI 316L przed i po ekspozycji w sztucznym moczu. Analiza wyników badań wskazuje na korzystny wpływ zaproponowanej obróbki powierzchniowej stali AISI 316L. Najkorzystniejszą charakterystykę fizykochemiczną i elektrochemiczną miały próbki o powierzchni polerowanej elektrolitycznie i pasywowanej chemicznie. Przeprowadzone w pracy badania stanowią podstawę do dalszych analiz związanych z zagadnieniem biokompatybilności stali Cr-Ni-Mo stosowanej na implanty w urologii.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 625-630
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Properties of Particles Emitted from Selected Coal-Fired Heating Plants and Electric Power Stations in Poland : Preliminary Results
Autorzy:
Pastuszka, J.S.
Konieczyński, J.
Talik, E.
Powiązania:
https://bibliotekanauki.pl/articles/205429.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
particulates emission
coal-fired power
heating station
surface chemical composition
X-ray
photoelectron spectroscopy
XPS
specific absorption
Opis:
The surface properties of particles emitted from six selected coal-fired power and heating plants in Poland have been studied in this work for the first time. Samples were collected beyond the control systems. Surface composition of the size-distributed particles was obtained by photoelectron spectroscopy (XPS). The reflection of the smallest, submicron particles was also measured to calculate their specific/mass absorption. The surface layer of the emitted particles was clearly dominated by oxygen, followed by silicon and carbon. The sum of the relative concentration of these elements was between 85.1% and 91.1% for coarse particles and 71.8–93.4% for fine/submicron particles. Aluminum was typically the fourth or fifth, or at least the sixth most common element. The mass absorption of the submicron particles emitted from the studied plants ranged from 0.02 m2g-1 to 0.03 m2g-1. Only specific absorption obtained for the “Nowy Wirek” heating plant was significantly higher than in other studied plants probably because the obsolete fire grate is used in this heating plant. The obtained results suggest that the power/heating-plant-emitted fine particles contain less carbonaceous material/elemental carbon on their surfaces than those that are typical in urban air.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 13-27
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies