Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sensors" wg kryterium: Temat


Tytuł:
The sensitivity of sensor structures with oxide graphene exposed to selected gaseous atmospheres
Autorzy:
Pustelny, T.
Drewniak, S.
Setkiewicz, M.
Maciak, E.
Urbańczyk, M.
Procek, M.
Gut, K.
Opilski, Z.
Jagiello, J.
Lipinska, L.
Powiązania:
https://bibliotekanauki.pl/articles/200229.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
graphene
graphene oxide
gas sensors
resistive sensors
Opis:
The paper presents the results of investigations on the resistive structure with a graphene oxide (GO) sensing layer. The effects of dangerous gases (hydrogen and nitrogen dioxide) on the structure were studied; the resistance changes were examined during the flow of the selected gas in the atmosphere of synthetic air. Measurements were performed with a special emphasis on the detection of low concentrations of the analyzed gases. The reactions of the sensing structure to the effect of nitrogen and synthetic air at different humidity were also tested. Much attention was also paid to the fast response of the sensor to the changes in the gas atmosphere. The thin palladium layer (~2 nm) has been applied in order to improve the sensing properties of the structure. The investigations were performed in the temperature range from RT to 120°C and the analyzed gases in synthetic air were batched alternately with pure synthetic air.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 705-710
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical fibre current sensor for electrical power engineering
Autorzy:
Barczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/200123.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnetooptic effect
optical fiber current sensors
polarimetric sensors
Opis:
The paper presents the experimental results of the investigations of optical fibre current sensors with an external transformation. The head of the sensor is made of the glass which has a high value of the Verdet constant. The sensor was built on the glass bar (with high value of the Verdet coefficient), polarisers, plastic optical fibres, a light source and a detector module. The paper deals with magnetic field measurements of two types of electrical current conductors: a typical conductor with circular cross-section and a busduct. Output signals from the optical current sensor were displayed on the digital oscilloscope and memorized in ěComp for a further analysis. This type of sensor was investigated on a laboratory stand and on an electrical power line which included conductor where the high intensity electric current flow. The constructed optoelectronic current sensor was tested for detection of current with intensity of the order of 200 A, with an accuracy of a few percent. Practically, the upper border of the current detection by means of this sensor is much higher.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 409-414
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study of Types of Sensors used in Remote Sensing
Autorzy:
Vincent, Shweta
Francis, Sharmila Anand John
Raimond, Kumudha
Kumar, Om Prakash
Powiązania:
https://bibliotekanauki.pl/articles/227262.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
disaster management
microwave sensors
optical sensors
Remote Sensing
Opis:
Of late, the science of Remote Sensing has been gaining a lot of interest and attention due to its wide variety of applications. Remotely sensed data can be used in various fields such as medicine, agriculture, engineering, weather forecasting, military tactics, disaster management etc. only to name a few. This article presents a study of the two categories of sensors namely optical and microwave which are used for remotely sensing the occurrence of disasters such as earthquakes, floods, landslides, avalanches, tropical cyclones and suspicious movements. The remotely sensed data acquired either through satellites or through ground based-synthetic aperture radar systems could be used to avert or mitigate a disaster or to perform a post-disaster analysis.
Źródło:
International Journal of Electronics and Telecommunications; 2019, 65, 2; 217-228
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Explosives vapors–concentrating and optoelectronic detection
Autorzy:
Wojtas, J.
Rutecka, B.
Popiel, S.
Nawała, J.
Wesołowski, M.
Mikołajczyk, J.
Cudziło, S.
Bielecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/221395.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
explosives concentrator
explosive detection
optoelectronic sensors
CEAS sensors
Opis:
Detection of explosives vapors is an extremely difficult task. The sensitivity of currently constructed detectors is often insufficient. The paper presents a description of an explosive vapors concentrator that improves the detection limit of some explosives detectors. These detector s have been developed at the Institute of Optoelectronics. The concentrator is especially dedicated to operate with nitrogen oxide detectors. Preliminary measurements show that using the concentrator, the recorded amount of nitrogen dioxide released from a 0.5 ng sample of TNT increases by a factor of approx. 20. In the concentrator an induction heater is applied. Thanks to this and because of the miniaturization of the container with an adsorbing material (approx. 1 cm3), an extremely high rate of tempera ture growth is achieved (up to 500°C within approx. 25 s). The concentration process is controlled by a microcontroller. Compact construction and battery power supply provide a possibility of using the concentrator as a portable device.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 177-190
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low Humidity Characteristics of Polymer-Based Capacitive Humidity Sensors
Autorzy:
Majewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/221201.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polymer-based capacitive humidity sensors
low humidity measurement
humidity sensors modelling
Opis:
Polymer-based capacitive humidity sensors emerged around 40 years ago; nevertheless, they currently constitute large part of sensors’ market within a range of medium (climatic and industrial) humidity 20-80%RH due to their linearity, stability and cost-effectiveness. However, for low humidity values (0-20%RH) that type of sensor exhibits increasingly nonlinear characteristics with decreasing of humidity values. This paper presents the results of some experimental trials of CMOS polymer-based capacitive humidity sensors, as well as of modelling the behaviour of that type of sensor. A logarithmic functional relationship between the relative humidity and the change of sensor output value at low humidity is suggested.
Źródło:
Metrology and Measurement Systems; 2017, 24, 4; 607-616
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effects of humidity on the stability of LTCC pressure sensors
Autorzy:
Santo Zarnik, M.
Belavic, D.
Powiązania:
https://bibliotekanauki.pl/articles/221696.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thick-film piezoresistive sensors
capacitive pressure sensors
offset stability
relative humidity
Opis:
LTCC-based pressure sensors are promising candidates for wet-wet applications in which the effect of the surrounding media on the sensor's characteristics is of key importance. The effect of humidity on the sensor's stability can be a problem, particularly in the case of capacitive sensors. A differential mode of operation can be a good solution, but manufacturing the appropriate sensing capacitors remains a major challenge. In the case of piezoresistive sensors the influence of humidity is less critical, but it still should be considered as an important parameter when designing sensors for low-pressure ranges. In this paper we discuss the stability of the sensors' offset characteristics, which was inspected closely using experimental and numerical analyses.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 133-140
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New Approach to Measurement of Frequency Shifts Using the Principle of Rational Approximations
Autorzy:
Murrieta-Rico, F. N.
Petranovskii, V.
Sergiyenko, O. Y.
Hernandez-Balbuena, D.
Lindner, L.
Powiązania:
https://bibliotekanauki.pl/articles/220851.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency measurement
rational approximations
sensors
Opis:
When a frequency domain sensor is under the effect of an input stimulus, there is a frequency shift at its output. One of the most important advantages of such sensors is their converting a physical input parameter into time variations. In consequence, changes of an input stimulus can be quantified very precisely, provided that a proper frequency counter/meter is used. Unfortunately, it is well known in the time-frequency metrology that if a higher accuracy in measurements is needed, a longer time for measuring is required. The principle of rational approximations is a method to measure a signal frequency. One of its main properties is that the time required for measuring decreases when the order of an unknown frequency increases. In particular, this work shows a new measurement technique, which is devoted to measuring the frequency shifts that occur in frequency domain sensors. The presented research result is a modification of the principle of rational approximations. In this work a mathematical analysis is presented, and the theory of this new measurement method is analysed in detail. As a result, a new formalism for frequency measurement is proposed, which improves resolution and reduces the measurement time.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 45-56
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Directed Cooperation in Multihop Wireless Sensors Network
Autorzy:
Nikodem, J.
Klempous, R.
Nikodem, M.
Woda, M.
Chaczko, Z.
Powiązania:
https://bibliotekanauki.pl/articles/226150.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wireless sensors network
directed cooperation
relations
Opis:
This paper proposes a relational abstraction for Wireless Sensors Network where node can identify its neighbors around it. Because of limited radio link range only some of nodes have a direct contact with the base station and transmission is carried out in a multihop way so information is send from one node to another towards the BS. We propose a relation π that represents cooperation between nodes and takes advantages of topological properties of the network. Based on the hop-distance from the BS any node k can determine a set N<(k) that consists of nodes to which k should send messages in order to retain a data-flow direction towards the BS.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 1; 7-11
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparison of Proximity Sensors for a Bicycle-to-Car Distance Rangefinder
Autorzy:
Zieliński, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/1844684.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distance measurement
road traffic
proximity sensors
Opis:
In the article, three types of proximity sensors that might be used in bicycle rangefinder to measure the distance between the bicycle and an overtaking car are compared. The influence of various factors on the accuracy of the distance measurements obtained using ultrasonic, infrared and laser sensors is tested, among others, light conditions, car surface type and colour, rain, pollination and vibrations.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 2; 277-282
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas sensors based on nanostructures of semiconductors ZnO and TiO2
Autorzy:
Pustelny, T.
Procek, M.
Maciak, E.
Stolarczyk, A.
Drewniak, S.
Urbańczyk, M.
Setkiewicz, M.
Gut, K.
Opilski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/201719.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas sensors
nanostructures
TiO2
ZnO
Opis:
The paper presents a resistance structures with sensor layers based on nanostructures elaborated on the base of TiO2 and ZnO. The structures were tested concerning their sensitivities to the effects of nitrogen dioxide in the atmosphere of synthetic air. The TiO2 and ZnO nanostructures played the role of sensor layers. Investigations have proved that the elaborated resistance structures with TiO2 and ZnO layers are sensitive to the presence of NO2 in the atmosphere of synthetic air. The resistance of the structure amounted to about 20 in the case of ZnO structures and to about 200 in the case of TiO2 structures. The investigations confirmed that resistance structures with ZnO and TiO2, exposed to the effect of nitrogen dioxide in the atmosphere of synthetic air changes their resistances relatively fast. This indicates that such structures might be practically applied in sensors of nitrogen dioxide ensuring a short time of response.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 4; 853-859
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of Surface Acoustic Wave Sensors for the Detection and Identification of Toxic Environmental Gases/Vapours
Autorzy:
Panneerselvam, G.
Thirumal, V.
Pandya, H. M.
Powiązania:
https://bibliotekanauki.pl/articles/176789.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
toxic gases
SAW
surface acoustic wave
SAW sensors
E-Nose
electronic nose
gas sensors
selective coating
Opis:
Detection and identification of toxic environmental gases have assumed paramount importance precisely in the defense, industrial and civilian security sector. Numerous methods have been developed for the sensing of toxic gases in the environment ever since surface acoustic wave (SAW) technology came into existence. Such SAW sensors called electronic nose (E-Nose) sensor use the frequency response of a delay line/resonator. SAW device is focused and given importance. The selective coating between input and output interdigital transducers (IDTs) in the SAW device is responsible for corresponding changes in operating frequency of the device for a specific gas/vapour absorbed from the environment. A suitable combination of well-designed SAW delay lines with selective coatings not only help to improve sensor sensitivity and selectivity but also leads to the minimization of false frequency alarms in the E-Nose sensor. This article presents a comprehensive review of design, development, simulation and modelling of a SAW sensor for potential sensing of toxic environmental gases.
Źródło:
Archives of Acoustics; 2018, 43, 3; 357-367
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wearable Biosensor: How to Improve the Efficacy in Data Transmission in Respiratory Monitoring System?
Autorzy:
Kanthi, M.
Dilli, Ravilla
Powiązania:
https://bibliotekanauki.pl/articles/2200696.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
data format
microcontrollers
respiration
sensors
time synchronization
Opis:
Respiratory rate measurement is important under different types of health issues. The need for technological developments for measuring respiratory rate has become imperative for healthcare professionals. The paper presents an approach to respiratory monitoring, with the aim to improve the accuracy and efficacy of the data monitored. We use multiple types of sensors on various locations on the body to continuously transmit real-time data, which is processed to calculate the respiration rate. Variations in the respiration rate will help us identify the current health condition of the patient also for diagnosis and further medical treatment. The software tools such as Keil μVision IDE, Mbed Studio IDE, Energia IDE are used to compile and build the system architecture and display information. EasyEDA is used to provide pin map details and complete architecture information.
Źródło:
International Journal of Electronics and Telecommunications; 2023, 69, 1; 25--32
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fibre-optic sensor for simultaneous measurement of thickness and refractive index of liquid layers
Autorzy:
Marzejon, Marcin
Karpienko, Katarzyna
Mazikowski, Adam
Jędrzejewska-Szczerska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/220419.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fibre-optic
sensors
interferometry
Fabry-Pérot interferometer
Opis:
In this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry-Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We performed a series of experiments using two light sources and only one sensing head. The spectra were collected in ranges of 1220-1340 nm and 1500-1640 nm. The obtained results show that using two spectra recorded simultaneously for two wavelength ranges enables to determine thickness in a range of 50-500 μm, and refractive index of a liquid film in a range of 1.00-1.41 RIU using only one sensing head.
Źródło:
Metrology and Measurement Systems; 2019, 26, 3; 561-568
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Matching Characteristics of Annular Piezoelectric Ultrasonic Sensor
Autorzy:
Li, Haoran
Hu, Yan
Li, Laibo
Xu, Dongyu
Powiązania:
https://bibliotekanauki.pl/articles/2141675.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
piezoelectric ceramics
ultrasonic sensors
acoustic matching characteristics
Opis:
Using intelligent materials and sensors to monitor the safety of concrete structures is a hot topic in the field of civil engineering. In order to realize the omni-directional monitoring of concrete structural damage, the authors of this paper designed and fabricated an embedded annular piezoelectric ultrasonic sensor using the annular piezoelectric lead zirconate titanate (PZT) ceramic as a sensing element and epoxy resin as the matching and the backing layers. The influence of different matching and backing layers thickness on the acoustic characteristic parameters of the sensor were studied. The results show that the resonant frequency corresponding to the axial mode of annular piezoelectric ceramics moves toward the high frequency direction with the decrease of the height of piezoelectric ceramics, and the radial vibration mode increases as well as the impedance peak. With the thickness of the backing layer increases from 1 mm to 2 mm, the radial resolution of the annular piezoelectric ultrasonic sensor is enhanced, the pulse width is reduced by 39% comparing with the sensors which backing layer is 1 mm, and the head wave amplitude and −3 dB bandwidth are increased by 61% and 66%, respectively. When the matching layer thickness is 3 mm, the sensor has the highest amplitude response of 269 mV and higher sensitivity.
Źródło:
Archives of Acoustics; 2022, 47, 2; 275-284
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards tuning of thermal sensitivity of the long period fiber gratings using a liquid crystal layer
Autorzy:
Czapla, A.
Bock, W.
Mikulic, P.
Woliński, T.
Powiązania:
https://bibliotekanauki.pl/articles/200642.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
long period fiber grating
liquid crystal
sensors
Opis:
A high-efficiency thermal tuning filter based on a long-period fiber grating (LPFG) combined with a low-birefringence liquid crystal (LB LC) cladding layer is presented. Two types of LPFGs were studied and compared: the LPFGs based on a standard telecommunication fiber produced by an electric arc technique, and the LPFGs based on a boron co-doped fiber written by a UV technique. Both types of LPFGs when enhanced with an external LB LC layer exhibit two different temperature sensitivities, which depend on the temperature range of operation. For the LPFGs based on standard telecommunication fiber we can conclude that the presence of the LB LC cladding increases the thermal tuning efficiency by more than one order of magnitude over the value for the LPFGs in air. In the case of the LPFGs based on the boron co-doped fiber we discovered it is possible to obtain either a temperature-independent attenuation band or the attenuation bands with high temperature sensitivities, just by careful choice of the order of the cladding mode and the operating wavelength.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 4; 503-508
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies