Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "źródło ciepła" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Evolution of microclimatic conditions in Paskov Mine
Ewolucja warunków mikroklimatycznych w Kopalni Paskov
Autorzy:
Zapletal, P.
Prokop, P.
Kosnovsky, V.
Powiązania:
https://bibliotekanauki.pl/articles/218734.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalń
warunki klimatyczne
źródło ciepła
urządzenie chłodnicze
mine ventilation
climatic conditions
source of heat
refrigerating unit
Opis:
The main subject of this paper focuses on scientific and research activities conducted in the Institute of Mining Engineering and Safety of the VŠB-Technical University of Ostrava. Cooperation between the VŠB-Technical University of Ostrava and OKD A.S., the only representative of coal mining in the Ostrava-Karviná coal basin, has recently begun to develop again. This paper describes an example discussed in a certain study, which has been undertaken for the Paskov mine, OKD a.s., dealing specifically with the evolution of microclimate parameters in mines that depend on the progress of mining activity at deeper levels over a period of several years. To this end, a special program, aimed at determination of the necessary refrigerating capacity, was established at the VŠB-Technical University of Ostrava.
W związku ze schodzeniem eksploatacji na większe głębokości i pogarszającymi się warunkami klimatycznymi OKD a.s. wystąpiła do VŠB-TU Ostrava, Wydział Górnictwa i Geologii o opracowanie studium pokazującego zmiany warunków mikroklimatycznych w kopalni Paskov w dwóch punktach czasowych oraz o określenie wymaganej mocy urządzeń chłodniczych. Do tego celu w VŠB-TU w Ostrawie opracowano specjalny program komputerowy określający wymagane moce chłodnicze. Na podstawie studium można podjąć decyzję o ewentualnym zamontowaniu centralnej klimatyzacji dla szybu zastępującej dotychczasowe lokalne jednostki chłodnicze. Studium przeprowadzono zgodnie z rozporządzeniem Czeskiego Urzędu Górnictwa nr 22/1989 w sprawie bezpieczeństwa i higieny pracy oraz bezpieczeństwa przy eksploatacji złóż górniczych oraz przy głębinowym wydobyciu surowców mineralnych, zgodnie z rozporządzeniem Czeskiego Urzędu Górnictwa nr 165/2002 w sprawie odrębnych systemów przewietrzenia w przypadku działalności wydobywczej w kopalniach, w których występuje gaz kopalniany oraz zgodne z rozporządzeniem Rady Ministrów nr 361/2007 w sprawie określenia warunków higieny pracy oraz zgodnie z pozostałymi obowiązującymi przepisami. Dla przejrzystości obliczeń zmian warunków mikroklimatycznych na wyrobiskach Kopalni Paskov do badań wybrano rejon przyszłego wydobycia - ściany nr 080 210 oraz drążonego wyrobiska nr 080 5255. Omawiany rejon pokładu 080 (dla przyszłej ściany nr 080 210 oraz eksploatowanego wyrobiska nr 080 5255) znajduje się w posieci wentylacyjnej szybu wylotowego nr II/4 (miejscowość Staříč). Wyrobiska zlokalizowano w odrębnym sektorze wentylacyjnym nr 080 210. W poszczególnych odcinkach zostały zainstalowane punktowe źródła ciepła (szczegóły w artykule) oraz lokalne urządzenia chłodnicze, co zostało przedstawione na rys. 1. Przez zainstalowanie klimatyzatorów lokalnych DV 150 w sieci wentylacyjnej w rejonie poddanym badaniu, tzn. w odrębnym sektorze wentylacyjnym nr 080 210, tj. w chodniku nr 080 5253 przed wlotem do wentylatora lutniowego APXK 630 wentylacji odrębnej drążonego chodnika nr 080 5255 oraz w chodniku nr 080 5253 w bliskim przedpolu ściany nr 080 210 doszło do wyraźnej poprawy warunków mikroklimatycznych dla ściany nr 080 210 oraz w jej chodniku wentylacyjnym (z sześciu przerw z powodu pogorszonych warunków mikroklimatycznych bez zainstalowanych klimatyzatorów lokalnych do stanu bez przerwy po zainstalowaniu klimatyzatorów lokalnych), jak również do poprawy warunków mikroklimatycznych na przodku drążonego chodnika nr 080 5255 przy akceptowalnych warunkach mikroklimatycznych w rejonie odprowadzenia strumienia wentylacyjnego z wyrobiska nr 080 5255 posiadającego wentylację odrębną. Przewidywana moc chłodnicza dla rejonu odrębnego sektora wentylacyjnego 080 210 wynosi 300 kW. Badania wskazały na istotną zależność, zgodnie z którą wraz ze wzrostem głębokości wydobycia pogarszają się warunki mikroklimatyczne w miejscu pracy. W przykładzie opisujemy wyrobisko przewidywane na rok 2012, znajdujące się na granicy eksploatacji podpoziomowej. Na tym przykładzie widać, że bez urządzeń chłodniczych nie byłaby możliwa eksploatacja w tym rejonie. W przypadku eksploatacji podpoziomowej warunki mikroklimatyczne w wielu planowanych wyrobiskach osiągały jeszcze gorsze wskaźniki. Z powyższego wynika ważny wniosek, że z punktu widzenia przepisów bezpieczeństwa i higieny pracy nie jest możliwe prowadzenie prac w takich miejscach bez lokalnych urządzeń chłodniczych lub bez centralnego systemu klimatyzacji.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 1045-1055
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of distance between heat sources in hybrid welded plate on fusion zone geometry
Wpływ odległości źródeł ciepła w płaskowniku spawanym hybrydowo na geometrię strefy przetopionej
Autorzy:
Piekarska, W.
Kubiak, M.
Saternus, Z.
Powiązania:
https://bibliotekanauki.pl/articles/383366.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid heat source
temperature field
fluid flow
numerical analysis
źródło ciepła hybrydowe
pole temperatury
przepływ cieczy
analiza numeryczna
Opis:
Results of numerical analysis into temperature field in hybrid laser-arc welding process with motion of liquid material taken into account are presented in this study. On the basis of obtained results the influence of the distance between the arc foot point and the laser beam focal point on the shape and size of fusion zone in hybrid butt welded plate. Temperature field was calculated on the basis of solution of transient heat transfer equation. The solution of Navier-Stokes equation allowed for simulation of fluid flow in the fusion zone. Fuzzy solidification front was assumed in calculations with linear approximation of solid fraction in solid-liquid region where liquid material flow through porous medium is taken into consideration. Numerical solution algorithms were developed for three-dimensional problem. Established numerical model of hybrid welding process takes into account different electric arc and laser beam heat sources power distributions.
W pracy przedstawiono wyniki numerycznej analizy pola temperatury w procesie spawania hybrydowego laser-łuk elektryczny z uwzględnieniem ruchu ciekłego metalu w strefie przetopienia. Na podstawie otrzymanych wyników oszacowano wpływ odległości elektrody od punktu skupienia wiązki laserowej na kształt strefy przetopionej płaskownika spawanego doczołowo. Pole temperatury otrzymano z rozwiązania równania nieustalonego przewodzenia. Rozwiązanie równania Naviera–Stokesa pozwoliło na symulację ruch cieczy w strefie przetopienia. Przyjęto łagodny front krzepnięcia z liniową aproksymacją udziału fazy stałej w obszarze dwufazowym, w którym uwzględniono ruch cieczy przez medium porowate. Opracowano algorytm numeryczny dla zagadnienia trójwymiarowego. W modelu numerycznym procesu spawania hybrydowym źródłem ciepła uwzględniono różne rozkłady mocy źródeł ciepła łuku elektrycznego i wiązki laserowej.
Źródło:
Archives of Foundry Engineering; 2011, 11, 2 spec.; 181-184
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of diffusion and internal heat source on a two-temperature thermoelastic medium with three-phase-lag model
Autorzy:
Othman, M. I.
Said, S. M.
Powiązania:
https://bibliotekanauki.pl/articles/240881.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
diffusion
Green-Naghdi theory
internal heat source
three-phase-lag model
two-temperature
dyfuzja
teoria Greena-Naghdiego
źródło ciepła
Opis:
The purpose of this paper is to depict the effect of diffusion and internal heat source on a two-temperature magneto-thermoelastic medium. The effect of magnetic field on two-temperature thermoelastic medium within the three-phase-lag model and Green-Naghdi theory without energy dissipation i discussed. The analytical method used to obtain the formula of the physical quantities is the normal mode analysis. Numerical results for the field quantities given in the physical domain are illustrated on the graphs. Comparisons are made with results of the two models with and without diffusion as well as the internal heat source and in the absence and presence of a magnetic field.
Źródło:
Archives of Thermodynamics; 2018, 39, 2; 15-39
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Artificial Neural Network to the Control of the Parameters of the Heat Treatment Process of Casting
Autorzy:
Wróbel, J.
Kulawik, A.
Bokota, A.
Powiązania:
https://bibliotekanauki.pl/articles/382692.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat treatment
moving heat source
artificial neural network
numerical modelling
control system
heating process
obróbka cieplna
źródło ciepła ruchome
sztuczna sieć neuronowa
modelowanie numeryczne
system sterowania
proces nagrzewania
Opis:
In the paper the use of the artificial neural network to the control of the work of heat treating equipment for the long axisymmetric steel elements with variable diameters is presented. It is assumed that the velocity of the heat source is modified in the process and is in real time updated according to the current diameter. The measurement of the diameter is performed at a constant distance from the heat source (Δz = 0). The main task of the model is control the assumed values of temperature at constant parameters of the heat source such as radius and power. Therefore the parameter of the process controlled by the artificial neural network is the velocity of the heat source. The input data of the network are the values of temperature and the radius of the heated element. The learning, testing and validation sets were determined by using the equation of steady heat transfer process with a convective term. To verify the possibilities of the presented algorithm, based on the solve of the unsteady heat conduction with finite element method, a numerical simulation is performed. The calculations confirm the effectiveness of use of the presented solution, in order to obtain for example the constant depth of the heat affected zone for the geometrically variable hardened axisymmetric objects.
Źródło:
Archives of Foundry Engineering; 2015, 15, 1; 119-124
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies