Tytuł:
An investigation on using the falling mass technique for dynamic force calibrations
Autorzy:
Gelany, Shaker A.
Mahmoud, Gouda M.
Powiązania:
https://bibliotekanauki.pl/articles/1849097.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration
dynamic calibration
impact force
falling weight
Opis:
In this paper, we present an experimental setup developed for the calibration of dynamic force transducers which is based on the drop mass method. The traceability to SI units is realized through well-known mass characteristics and a reference shock accelerometer attached to that mass. Two approaches are proposed to analyse dynamic force employing a drop mass system. One approach depends on the inertial force of a falling mass while the other deals with the work-energy principle. Results of both approaches are then compared to the response of a statically calibrated force transducer. It is shown that the obtained maximum relative deviations between the response of force transducer and the first approach results are 1% while those of the second approach are 2%.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 455-463
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An investigation on using the falling mass technique for dynamic force calibrations
Autorzy:
Gelany, Shaker A.
Mahmoud, Gouda M.
Powiązania:
https://bibliotekanauki.pl/articles/1849140.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration
dynamic calibration
impact force
falling weight
Opis:
In this paper, we present an experimental setup developed for the calibration of dynamic force transducers which is based on the drop mass method. The traceability to SI units is realized through well-known mass characteristics and a reference shock accelerometer attached to that mass. Two approaches are proposed to analyse dynamic force employing a drop mass system. One approach depends on the inertial force of a falling mass while the other deals with the work-energy principle. Results of both approaches are then compared to the response of a statically calibrated force transducer. It is shown that the obtained maximum relative deviations between the response of force transducer and the first approach results are 1% while those of the second approach are 2%.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 455-463
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An investigation on using the falling mass technique for dynamic force calibrations
Autorzy:
Gelany, Shaker A.
Mahmoud, Gouda M.
Powiązania:
https://bibliotekanauki.pl/articles/1849008.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
calibration
dynamic calibration
impact force
falling weight
Opis:
In this paper, we present an experimental setup developed for the calibration of dynamic force transducers which is based on the drop mass method. The traceability to SI units is realized through well-known mass characteristics and a reference shock accelerometer attached to that mass. Two approaches are proposed to analyse dynamic force employing a drop mass system. One approach depends on the inertial force of a falling mass while the other deals with the work-energy principle. Results of both approaches are then compared to the response of a statically calibrated force transducer. It is shown that the obtained maximum relative deviations between the response of force transducer and the first approach results are 1% while those of the second approach are 2%.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 455-463
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Establishing and characterizing a permanent magnet system for the prototype of NISs Kibble balance
Autorzy:
Emira, Sayed
Shaaban, E. R.
Rashad, M. M.
Gelany, Shaker A.
Powiązania:
https://bibliotekanauki.pl/articles/2203366.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Kibble balance
Planck constant
magnet system
magnetic field
Opis:
The Kibble balance experiment is used to redefine the kilogram as a unit of mass based on the Planck constant. To demonstrate and understand the basic principle of the Kibble balance, the National Institute of Standards (NIS)-Egypt has constructed a prototype Kibble balance that can measure gram-level masses with 0.01% relative uncertainty. Through the construction of this prototype, the challenges can be studied and addressed to overcome the weaknesses of NIS’s prototype. This study presents the design and construction of the prototype Kibble balance. It also focuses on the design and performance of the magnetic system, which is a crucial element of the Kibble balance. Analytical modeling and finite element analysis were used to evaluate and improve the magnet system. Several other aspects were also discussed, including the yoke’s material and enhancing the magnetic profile within the air gap of the magnet system. Over a vertical distance of 30 mm inside the air gap, the magnetic flux density was found to be 0.3 T, and the uniformity was found to be 8 x 10-5.
Źródło:
Metrology and Measurement Systems; 2023, 30, 1; 3--16
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study to determine food consumption of cotton leafworm, Spodoptera littoralis, on some cotton genotypes
Autorzy:
Khedr, M.A.
Al-Shannaf, H.M.
Mead, H.M.
Shaker, S.A.E.-A.
Powiązania:
https://bibliotekanauki.pl/articles/65971.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
comparative study
food consumption
cotton leafworm
Spodoptera littoralis
cotton
genotype
Opis:
A study was done on the feeding behaviour, development indices, and biochemical response of 4th instar larvae of Spodoptera littoralis in which seven cotton genotypes were used: Giza86, Giza88, Giza92, 10229 × Giza 86, H10, Suvin, and Karshenseki. Castor bean leaves were used as the control. All the tested cotton genotypes decreased the feeding behavior of S. littoralis larvae in terms of consumption percentages, consumption rate (CR), growth rates (GR), efficiency of conversion of ingested and digested food (ECI and ECD), approximate digestibility (AD), and feeding deterrence (FDI) compared to the control. Additionally, all the tested cotton varieties prolonged the time taken for larval and pupal duration and reduced both the pupation percentages and the weight of the resulting pupae, as compared to the control. Giza86 recorded the lowest values of both larval growth index and fitness (7.31 and 1.05, respectively) while the genotype Suvin recorded the lowest standardised growth index (0.020) more than other genotypes and the control that gave 10.16, 1.53, and 0.032, respectively. There was a significant inhibition in the level of both total soluble protein and total lipids, and activities of amylase and the trehalase enzymes in all the tested varieties, compared to that found in the control.
Źródło:
Journal of Plant Protection Research; 2015, 55, 3
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies