Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "liquid gas" wg kryterium: Wszystkie pola


Tytuł:
Simultaneous velocity measurement of phases in a liquid-gas system
Autorzy:
Musoski, R.
Stelmach, J.
Powiązania:
https://bibliotekanauki.pl/articles/185238.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fluorescence
self-aspirating impeller
phase velocity
PIV
fluorescencja
samozasysający wirnik
prędkość fazowa
Opis:
Results of velocity measurements of liquid and gas bubbles in a tank with a self-aspirating disk impeller are analysed. Studies were carried out using a fluorescent dye tracer in the measuring system with two cameras (simultaneous phase velocity measurement) and with one camera (sequential measurement of phase velocity). Based on a comparative analysis of the acquired data it was found that when differences in the phase velocities were small the simultaneous velocity measurement gave good results. However, sequential measurement gives greater possibilities for setting the measuring system and if the analysis of instantaneous velocities is not necessary, it seems to be a better solution.
Źródło:
Chemical and Process Engineering; 2017, 38, 4; 577-585
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of liquid-gas flow in pipeline using gamma-ray absorption technique and advanced signal processing
Autorzy:
Hanus, Robert
Zych, Marcin
Mosorov, Volodymyr
Golijanek-Jędrzejczyk, Anna
Jaszczur, Marek
Andruszkiewicz, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1848957.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase flow
void fraction
gamma-ray absorption
flow regime identification
artificial neural network
Opis:
Liquid-gas flows in pipelines appear in many industrial processes, e.g. in the nuclear, mining, and oil industry. The gamma-absorption technique is one of the methods that can be successfully applied to study such flows. This paper presents the use of the gamma-absorption method to determine the water-air flow parameters in a horizontal pipeline. Three flow types were studied in this work: plug, transitional plug-bubble, and bubble one. In the research, a radiometric set consisting of two Am-241 sources and two NaI(TI) scintillation detectors have been applied. Based on the analysis of the signals from both scintillation detectors, the gas phase velocity was calculated using the cross-correlation method (CCM). The signal from one detector was used to determine the void fraction and to recognise the flow regime. In the latter case, a Multi-Layer Perceptron-type artificial neural network (ANN) was applied. To reduce the number of signal features, the principal component analysis (PCA) was used. The expanded uncertainties of gas velocity and void fraction obtained for the flow types studied in this paper did not exceed 4.3% and 7.4% respectively. All three types of analyzed flows were recognised with 100% accuracy. Results of the experiments confirm the usefulness of the gamma-ray absorption method in combination with radiometric signal analysis by CCM and ANN with PCA for comprehensive analysis of liquid-gas flow in the pipeline.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 145-159
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of raw liquid natural gas composition on combustion properties and emission characteristic
Autorzy:
Czyżewski, Paweł
Ślefarski, Rafał
Jójka, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2204069.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
toxic compounds
fuel flexibility
liquid natural gas
NO emission
Opis:
The article presents the results of numerical and analytical investigations of the influence of raw liquid natural gas (LNG) composition on parameters characterizing the combustion process. The high content of higher hydrocarbons influences the thermodynamic combustion process described with parameters like the adiabatic flame temperature, laminar flame speed and ignition delay time. A numerical study of the impact of LNG fuels on emission characteristics using the Cantera code has been performed. Results have shown that the change of grid natural gas to some types of liquid natural gas can result in an incomplete combustion process and an increase of emission of toxic compounds such as carbon monoxide and unburned hydrocarbons. For all investigated fuels the laminar flame speed rises by about 10% compared to natural gas, while the adiabatic flame temperature is nearly the same. The ignition delay time is decreased with an increase of ethane share in the fuel. The analysis of chemical pathways has shown that hydrogen cyanide and hydrogen formation is present, particularly in the high temperature combustion regimes, which results in an increase of nitric oxide molar fraction in flue gases by even 10% compared to natural gas. To summarize, for some applications, liquid natural gases cannot be directly used as interchangeable fuels in an industry sector, even if they meet the legal requirements.
Źródło:
Archives of Thermodynamics; 2023, 44, 1; 3--21
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Absorption of CO2 into perfluorinated gas carrier in the Taylor gas–liquid flow in a microchannel system
Autorzy:
Sobieszuk, P.
Pilarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/185397.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
perfluorodecalin (PFD)
liquid gas carrier
solubility
Taylor flow
microreactor
perfluorodekalina (PFD)
gaz ciekły
rozpuszczalność
przepływ Taylora
mikroreaktor
Opis:
The aim of this study was to determine the solubility of CO2 in perfluorodecalin (PFD) which is frequently used as efficient liquid carrier of respiratory gases in bioprocess engineering. The application of perfluorinated liquid in a microsystem has been presented. Gas-liquid mass transfer during Taylor (slug) flow in a microchannel of circular cross section 0.4 mm in diameter has been investigated. A physicochemical system of the absorption of CO2 from the CO2/N2 mixture in perfluorodecalin has been applied. The Henry’s law constants have been found according to two theoretical approaches: physical (H = 1.22x10-3 mol/m3Pa) or chemical (H = 1.26x10-3 mol/m3Pa) absorption. We are hypothesising that the gas-liquid microchannel system is applicable to determine the solubility of respiratory gases in perfluorinated liquids.
Źródło:
Chemical and Process Engineering; 2012, 33, 4; 595-602
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Liquid Perfluorochemicals as Flexible and Efficient Gas Carriers Applied in Bioprocess Engineering: An Updated Overview and Future Prospects
Autorzy:
Pilarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/185200.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ciecz perfluorochemiczna
fluorowęgiel
gaz ciekły
rozpuszczalność
hybrydowy system hodowli
liquid perfluorochemical
fluorocarbon
liquid gas carrier
solubility
cell/tissue culture
hybrid culture system
Opis:
Fully synthetic, biochemically inert and water-immiscible liquid perfluorochemicals (PFCs) are recognised as flexible liquid carriers/scavengers of gaseous compounds (respiratory gases mainly, i.e. O2 and CO2) and increasingly applied in bioprocess engineering. A range of unmatched physicochemical properties of liquid PFCs, i.e. outstanding chemo- and thermostability, extremely low surface tension, simultaneous hydro- and lipophobicity, which result from carbon chain substitution with fluorine atoms (the most electronegative chemical element) and the presence of intramolecular C–F bonds (the strongest single bond known in organic chemistry) have been described in detail. Exceptional propensity to solubility of respiratory gases in liquid perfluorinated compounds has been widely discussed. Advantages and disadvantages of bioprocess applications of liquid PFCs in the form of a pure PFC as well as in an emulsified form have been pointed out. A liquid PFC-mediated mass transfer intensification in various types of microbial, plant cell and animal cell culture systems: from miniaturised microlitre-scale cultures, via biomaterial-based scaffolds containing culture systems, to litre-scale bioreactors, has been reviewed and elaborated on bearing in mind the benefits of bioprocesses.
Źródło:
Chemical and Process Engineering; 2014, 35, 4; 463-487
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of a hybrid culture system with a stationary layer of liquid perfluorochemical applied as oxygen carrier
Autorzy:
Pilarek, M.
Dąbkowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/185054.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
liquid perfluorochemical (fluorocarbon)
liquid gas carrier
mathematical modelling
cell/tissue culture
hybrid culture system
ciecz perfluorochemiczna (fluorowęglowa)
gaz ciekły
modelowanie matematyczne
hybrydowy system hodowli
Opis:
A mathematical model of a hybrid culture system supported with a stationary layer of liquid perfluorochemical (PFC) as a source of O2 for cells which grow in the aqueous phase of culture medium has been developed and discussed. The two-substrate Monod kinetics without inhibition effects, i.e. the Tsao-Hanson equation, has been assumed to characterise the biomass growth. The Damköhler number which relates the growth rate to the mass transfer effects has been used to appraise the regime (i.e. diffusion-limited or kinetics) of the whole process. The proposed model predicted accurately previously published data on the submerged batch cultures of Nicotiana tabacum BY-2 heterotrophic cells performed in a culture system supported with a stationary layer of hydrophobic perfluorodecalin as a liquid O2 carrier. Estimated values of the parameters of the model showed that the process proceeded in the kinetics regime and the growth kinetics, not the effects of the mass transfer between aqueous phase and liquid PFC, had essential influence on the growth of biomass.
Źródło:
Chemical and Process Engineering; 2016, 37, 1; 149-158
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure drop in two-phase gas-liquid (Taylor) flow in microreactors
Autorzy:
Cygański, P.
Sobieszuk, P.
Pohorecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/185780.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przepływ Taylora
przepływ gaz-ciecz
spadek ciśnienia
mikroreaktor
gas-liquid Taylor flow
microreactor
pressure drop
Opis:
The pressure drop in microreactors for the gas - liquid Taylor flow was measured for 4 different microreactor geometries and 3 different gas - liquid systems. The results have been compared with the existing literature correlations. A selection of the best correlations has been made.
Źródło:
Chemical and Process Engineering; 2012, 33, 3; 369-384
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy of intrinsic mode function for gas-liquid flow pattern identification
Autorzy:
Sun, Z.
Gong, H.
Powiązania:
https://bibliotekanauki.pl/articles/221137.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas-liquid flow pattern
flow-pattern map
pressure fluctuation
bluff body
signal energy
intrinsic mode function
empirical mode decomposition
Opis:
Gas-liquid flows abound in a great variety of industrial processes. Correct recognition of the regimes of a gas-liquid flow is one of the most formidable challenges in multiphase flow measurement. Here we put forward a novel approach to the classification of gas-liquid flow patterns. In this method a flow-pattern map is constructed based on the average energy of intrinsic mode function and the volumetric void fraction of gas-liquid mixture. The intrinsic mode function is extracted from the pressure fluctuation across a bluff body using the empirical mode decomposition technique. Experiments adopting air and water as the working fluids are conducted in the bubble, plug, slug, and annular flow patterns at ambient temperature and atmospheric pressure. Verification tests indicate that the identification rate of the flow-pattern map developed exceeds 90%. This approach is appropriate for the gas-liquid flow pattern identification in practical applications.
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 759-766
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free surface of the liquid-gas phase separation as a measuring membrane of a device for measuring small hydrostatic pressure difference values
Powierzchnia swobodna rozdziału faz ciecz-gaz jako membrana pomiarowa urządzenia do pomiaru małych wartości różnicy ciśnienia hydrostatycznego
Autorzy:
Filipek, W.
Broda, K.
Branny, M.
Powiązania:
https://bibliotekanauki.pl/articles/219111.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
small values of differential pressure measurement
filtration
pressure gauges
małe wartości różnicy ciśnień
pomiary
filtracja
manometry
Opis:
To obtain a correct reading of fluid flow through a porous medium, it is necessary to know the pressure distribution. While in the case of large Reynolds numbers (turbulent flows) finding pressure measurement devices on the market is not a major problem, there are currently no available devices with sufficient accuracy for measurement of laminar flows (i.e. for Re numbers (Bear, 1988; Duckworth, 1983; Troskolański, 1957) in the range from 0.01 to 3). The reasons of this situation has been discussed in a previous articles (Broda & Filipek, 2012, 2013). Therefore, most of the work on this issue relates to testing velocity distribution of the filter medium (Bear, 1988) or pressure distribution at high hydraulic gradient levels (Trzaska & Broda, 1991, 2000; Trzaska et al., 2005). The so-called measurements of the lower limit of the applicability of Darcy’s law for liquid, as well as determining a threshold hydraulic gradient J0 (Bear, 1988) tend to cause especially great difficulty. Such measurements would be particularly important application in determining the infiltration of water into the mine workings, filtering through the foundations of buildings, etc. For several years, the authors (Broda & Filipek, 2012, 2013) have been engaged in the development of methods and measuring instruments (patent applications: P.407 380 and P.407 381), which Gould allow for measurement of hydrostatic pressure (differences) below 1 Pa. In the course of research, a New concept of methodology for measuring low values of hydrostatic pressure differences was developed, which is the subject of this article. This article seeks to introduce a new concept of using the free surface of liquid-gas separation as the measuring membrane of a device used in measurement of small values of hydrostatic pressure. The fokus is mainly on the possibility of building such a device – describing the technical difficulties that occurred during the execution of the idea. Consequently, less attention was paid to the broader considerations related to uncertainty of the proposed method’s measurements, due to the authors’ awareness that this is the first prototype of such a device and, on the basis of this experience, another one will be built and tested. The observations and numerical analysis of the image formed on the screen by the passage of a laser beam through the free surface of the liquid-gas separation show that at low values of pressure difference, the bubble acts as a membrane shifting in the direction of lower pressure, in such way that the displacement is proportional to the pressure difference at both ends of the bubble. The proprietary method of numerical data processing presented in this article, based on analysis of the intensity of color change in a frame moving along a selected line outside of visual changes in the image ofthe laser beam after passing through the test structure, provided a tool to create first mathematical models to describe the observed changes (2),(3). Presented in this article method of measuring the difference between the free surface levels in two containers, and hence the measurement of hydrostatic pressure difference provides a new tool for laboratory measurements in the fields of science, which were previously unattainable.
Do poprawnego opisu przepływu płynu przez ośrodek porowaty niezbędna jest znajomość rozkładu ciśnienia. O ile dla dużych liczb Reynoldsa (przepływy turbulentne) pomiar ciśnienia dostępnymi na rynku przyrządami nie stanowi większego problemu, to dla przepływów laminarnych cieczy (tj. dla liczb Re (Bear, 1988; Duckworth, 1983; Troskolański, 1957) z zakresu 0.01 do 3) nie ma na rynku przyrządów o wystarczającej dokładności. Przyczyny powodujące taką sytuację zostały omówione w poprzednich opracowaniach (Broda i Filipek, 2012, 2013), Dlatego większość prac dotyczących tego zagadnienia dotyczy badań rozkładu prędkości medium filtrującego przez badany ośrodek (Bear, 1988) lub rozkładu ciśnienia przy wysokich spadkach hydraulicznych (Trzaska i Broda, 1991, 2000; Trzaska i in., 2005). Zwłaszcza pomiary w zakresie tzw. dolnej granicy stosowalności prawa Darcy’ego dla cieczy oraz dotyczące określenia progowego spadku hydraulicznego J0 (Bear, 1988) sprawiają wielkie trudności. Pomiary takie miałyby duże znaczenie aplikacyjne zwłaszcza przy określaniu infiltracji wody do wyrobisk górniczych, filtracji przez fundamenty budowli itp. Autorzy od kilku lat (Broda i Filipek, 2012, 2013) zajmują się opracowaniem metody oraz przyrządu pomiarowego (wnioski patentowe: P.407 380 i P.407 381) pozwalających na pomiary wartości ciśnienia (różnicy ciśnienia) hydrostatycznego poniżej 1 Pa. W tym okresie opracowali nową metodę pomiaru, skonstruowali stanowisko badawcze i przeprowadzili pomiary różnicy ciśnień hydrostatycznych z dokładnością do 0.5 Pa znacznie ograniczając zjawisko histerezy (Broda i Filipek, 2012) (wniosek patentowy: P.407 380). W oparciu o zdobyte doświadczenie prace kontynuowano opracowując metodę pomiaru i budując nowe stanowisko do pomiaru bardzo małych różnic ciśnień z kompensacją wpływu ciśnienia atmosferycznego o dużo prostszej budowie, co znacząco zwiększyło dokładność i wiarygodność pomiarów (Broda i Filipek, 2013) (wniosek patentowy: P. 407 381). W trakcie prac badawczych narodziła się nowa koncepcja metodologii pomiaru niskich wartości różnicy ciśnienia hydrostatycznego, która jest przedmiotem niniejszego artykułu. Na rysunku 1 przedstawiono zdjęcie stanowiska pomiarowego służącego do określenia wpływu zmiany wartości różnicy ciśnienia hydrostatycznego na kształt a co za tym idzie przemieszczenie powierzchni swobodnej rozdziału faz ciecz-gaz, oraz omówiono jego budowę zwracając uwagę na istotne szczegóły konstrukcyjne. Przedstawiono także sposób kalibrowania przyrządu, wykonywania i obróbki zdjęć fotograficznych w celach pomiarowych z wykorzystaniem napisanego w języku Delphi autorskiego programu do obróbki numerycznej zdjęć. Występujące trudności ilustruje rysunek 2 przedstawiający przesunięcie linii odniesienia w trzech kolejno po sobie wykonanych zdjęciach. Następnie omówiono sposób przygotowania stanowiska do pomiarów oraz sposób ich przeprowadzania czego ilustracją są rysunki 3 i 4. Przedstawiono występujące problemy oraz zastosowane sposoby ich rozwiązania. Zarejestrowany przykładowy obraz po przejściu promienia lasera przez badaną strukturę dla wybranych wartości różnicy ciśnień hydrostatycznych uzyskany za pomocą kulek ceramicznych przedstawiono na rysunku 5. Rysunek 6 wyjaśnia metodę obróbki numerycznej zdjęć w oparciu o autorski program i zależności (1),(2),(3). Na rysunkach 7 i 9 zestawiono otrzymane krzywe zmienności intensywności barw uzyskane w trakcie opracowania numerycznego. Zwrócono także uwagę na rozkład zmian intensywności barw dla różnicy między powierzchniami swobodnymi cieczy w cylindrach (Rys. 8-11) dla wybranych serii pomiarowych. W dalszej części artykułu dokonano analizy otrzymanych obrazów zwracając uwagę na włączenie metody transformacji Fouriera lub „Falkowej” (Ziółko, 2000) do numerycznej analizy posiadanych danych (Rys. 12-14). Na rysunku 12 pokazano wybrane trzy zależności opisujące zmienność natężania barwy w funkcji położenia ramki (1), dla których dokonano transformacji Fouriera według zależności (3). Analizy dokonano metodą arytmetyczna Perry’ego (Ziółko, 2000) w okienku o szerokości n = 2300 przyjmując jako położenie startowe wartość x = 1600. Rysunek 13 przedstawia wartości współczynnika Ak a rys.14 przedstawia wartości kąta przesunięcia jk dla pierwszych 58 harmonicznych. Prace nad udoskonaleniem metody trwają. W dalszej części artykułu autorzy podsumowują osiągnięte wyniki zwracając uwagę na uzyskaną precyzję pomiarów oraz korzystne zastosowanie powierzchni swobodnej rozdziału faz ciecz-gaz jako membrany pomiarowej urządzenia do pomiaru małych wartości różnicy ciśnienia hydrostatycznego (Rys. 15-16) sugerując wprowadzenie do analizy trzeciego wymiaru co wiąże się z koniecznością kosztownej modernizacji stanowiska pomiarowego.
Źródło:
Archives of Mining Sciences; 2015, 60, 1; 341-358
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of mass transfer in annular gas-liquid flow in a microreactor
Autorzy:
Sobieszuk, P.
Napieralska, K.
Powiązania:
https://bibliotekanauki.pl/articles/185266.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mass transfer
annular flow
microreactor
masa transferu
przepływ pierścieniowy
mikroreaktor
Opis:
The paper presents an investigation of mass transfer in gas-liquid annular flow in a microreactor. The microreactor had a meandered shape with a square cross-section of the channel (292×292 μm, hydraulic diameter 292 μm) and 250 mm in length. The rate of CO2 absorption from the CO2/N2 mixture in NaOH (0.1 M, 0.2 M, 0.7 M, 1.0 M and 1.5 M) water solutions was measured. Two velocities of gas flow and two velocities of liquid flow were used. In two cases a fully developed annular flow at the beginning of the channel was observed, whilst in two cases annular flow was formed only in about 2/3 of the microchannel length. Based on the measurements of CO2 absorption rate, the values of volumetric liquid – side mass transfer coefficients with the chemical reaction were determined. Then physical values of coefficients were found. Obtained results were discussed and their values were compared with the values predicted by literature correlations.
Źródło:
Chemical and Process Engineering; 2016, 37, 1; 55-64
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of rotating magnetic field on gas-liquid volumetric mass transfer coefficient
Autorzy:
Rakoczy, R.
Konopacki, M.
Kordas, M.
Powiązania:
https://bibliotekanauki.pl/articles/185156.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mass transfer
volumetric mass transfer coefficient
rotating magnetic field
transfer masy
wolumetryczny współczynnik przenikania masy
obracanie pola magnetycznego
Opis:
The main objective of these experiments was to study the oxygen mass transfer rate through the volumetric mass transfer coefficient (kLa) for an experimental set-up equipped with a rotating magnetic field (RMF) generator and various liquids. The experimental results indicated that kLa increased along the magnetic strength and the superficial gas velocity. Mathematical correlations defining the influence of the considered factors on kLa were proposed.
Źródło:
Chemical and Process Engineering; 2017, 38, 3; 423-432
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contribution of liquid-and gas-side mass transfer coefficients to overall mass transfer coefficient in Taylor flow in a microreactor
Autorzy:
Sobieszuk, P.
Ilnicki, F.
Pohorecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/185639.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Taylor flow
mass transfer coefficients
microreactor
CFD simulations
przepływ Taylora
współczynnik przenikania masy
mikroreaktor
symulacje CFD
Opis:
Gas-liquid microreactors find an increasing range of applications both in production, and for chemical analysis. The most often employed flow regime in these microreactors is Taylor flow. The rate of absorption of gases in liquids depends on gas-side and liquid-side resistances. There are several publications about liquid-side mass transfer coefficients in Taylor flow, but the data about gas-side mass transfer coefficients are practically non existent. We analysed the problem of gas-side mass transfer resistance in Taylor flow and determined conditions, in which it may influence the overall mass transfer rate. Investigations were performed using numerical simulations. The influence of the gas diffusivity, gas viscosity, channel diameter, bubble length and gas bubble velocity has been determined. It was found that in some case the mass transfer resistances in both phases are comparable and the gas-side resistance may be significant. In such cases, neglecting the gas-side coefficient may lead to errors in the experimental data interpretation.
Źródło:
Chemical and Process Engineering; 2014, 35, 1; 35-45
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of vessel scale on gas hold-up in gas-liquid systems
Autorzy:
Cudak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/2034059.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
agitated vessel
mixing
gas hold-up
aqueous sucrose solution
mieszanie
zatrzymywanie gazu
wodny roztwór sacharozy
Opis:
The aim of the research presented in this paper was to determine the effect of vessel scale on gas hold- up in gas-liquid systems. The agitated vessel with internal diameters of T = 0:288 m and T = 0:634 m was filled with a liquid up to the height H = T. For the purpose of measurements, two high-speed impellers were used: Rushton turbine impeller (RT) or A 315 impeller.Within the study, the following parameters were altered: superficial gas velocity, impeller speed, impeller type and concentration of aqueous sucrose solution. In addition, influence of the vessel scale on gas hold-up value was analysed. Experimental results were mathematically described. Equations (5)–(7) do not have equivalents in the literature.
Źródło:
Chemical and Process Engineering; 2020, 41, 4; 241-256
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A conductometric method for determining of the upward gas-liquid-liquid three-phase flow
Autorzy:
Płaczek, M.
Pietrzak, M.
Witczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/240235.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
conductometric method
three-phase flow
flow patterns
metoda konduktometryczna
fluidyzacja zawiesin
minikanały rurowe
Opis:
This paper reports the results of research involving observations of flow patterns during air-oil-water three-phase flow through a vertical pipe with an internal diameter of 0.03 m and a length of 3 m. The conductometric method based on the measurement of electrical conductivity of the gas-liquid-liquid system was used to evaluate the flow patterns. In the studies, a set of eight probes spaced concentrically in two tube sections (four probes per each) with a spacing of 0.015 m were used. The paper presents a theoretical description of the test method and the analysis of the measurement results for air-oil-water multiphase flow system. Results of this study indicate that the developed method of characterizing the voltage of the gas-liquid-liquid system can be an important tool supporting other methods to identify flow patterns, including visual observation.
Źródło:
Archives of Thermodynamics; 2018, 39, 3; 97-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD prediction of gas-liquid flow in an aerated stirred vessel using the population balance model
Autorzy:
Kálal, Z.
Jahoda, M.
Fořt, I.
Powiązania:
https://bibliotekanauki.pl/articles/185765.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CFD
mixing tank
gas-liquid
drag correction
bubble size distribution
zbiornik mieszający
gaz-ciecz
korekta przeciągania
rozkład wielkości pęcherzyków
Opis:
The main topic of this study is the experimental measurement and mathematical modelling of global gas hold-up and bubble size distribution in an aerated stirred vessel using the population balance method. The air-water system consisted of a mixing tank of diameter T= 0.29 m, which was equipped with a six-bladed Rushton turbine. Calculations were performed with CFD software CFX 14.5. Turbulent quantities were predicted using the standard k-ε turbulence model. Coalescence and breakup of bubbles were modelled using the homogeneous MUSIG method with 24 bubble size groups. To achieve a better prediction of the turbulent quantities, simulations were performed with much finer meshes than those that have been adopted so far for bubble size distribution modelling. Several different drag coefficient correlations were implemented in the solver, and their influence on the results was studied. Turbulent drag correction to reduce the bubble slip velocity proved to be essential to achieve agreement of the simulated gas distribution with experiments. To model the disintegration of bubbles, the widely adopted breakup model by Luo & Svendsen was used. However, its applicability was questioned.
Źródło:
Chemical and Process Engineering; 2014, 35, 1; 55-73
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies