Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Uzdatnianie wody"" wg kryterium: Wszystkie pola


Wyświetlanie 1-8 z 8
Tytuł:
Nanofiltration renovation of mineral water
Nanofiltracyjne uzdatnianie wody mineralnej
Autorzy:
Bodzek, M.
Tomaszewska, B.
Rajca, M.
Powiązania:
https://bibliotekanauki.pl/articles/205074.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mineral water
water renovation
nanofiltration
hydrogeochemical type of water
woda mineralna
uzdatnianie wody
nanofiltracja
hydrogeochemiczny rodzaj wody
Opis:
There is often a need to improve the taste of mineral water by reducing the sulphate ion content. It was found that for such an effect, nanofiltration (NF) process can be used. In the case, the proposed formula was assumed obtaining a mineral water with reduction of H2S and SO4 2- content through the following processes: stripping – UF/MF or rapid filtration – nanofiltration – mixing with raw water or filtration through calcium bed. The paper shows the results of the tests, with use of mineral waters and nanofiltration. Commercial nanofiltration membranes NF-270 Dow Filmtec and NF-DK GE Infrastructure Water&Process Technologies were applied. NF was carried out for mixed water from both water intakes (1 and 2), recovery of 50%, at transmembrane pressure of 0.8–1.2 MPa in the dead-end filtration mode. In addition, the permeate obtained in NF was filtered through a column filled with 1.0–3.0 mm limestone rock, in order to improve the composition of mineral water. The tested mineral water is the sulphate-chloride-sodium-calcium-magnesium in nature and contains 991 mg/L of SO42-and 2398 mg/L of TDS, while the permeate after NF showed the chloride – sodium hydrogeochemical type (TDS: 780–1470 mg/L, sulfate 10–202.7 mg/L, calcium 23–39.7 mg/L, magnesium 11–28 mg/L). As a result of water treatment in the NF process, high reduction of SO42- ions was obtained (79–98.7%), while the TDS was reduced in 51–64%. Because the process of NF allows for relatively high reduction of bivalent ions, a significant reduction in calcium ion content (84–88%) and magnesium (84–89%) has been also obtained. Monovalent ions were reduced to a lesser extent, i.e. sodium in 46% and bicarbonates in 39–64.1%. Despite obtaining the positive effect of the sulphate ions content reduction, the NF process significantly changed the mineralogy composition of water. The permeate filtration (DK-NF membrane) on the CaCO3 deposit led to a correction of the hydrogeochemical type of water from chloridesodium to chloride-bicarbonate-sodium. The concentration of calcium ions was increased by 60.5% and was 28.2 mg/L, and bicarbonate ions by 7.78% (increased to 195 mg/L). Based on a morphological assessment of the deposits in the SEM image and their chemical composition, the presence of gypsum crystals was detected on the surface of the NF-270 membrane. The deposits formed on the NF-DK membrane were of a completely different character as aggregations of iron and aluminium oxides/hydroxides were found. Such significant mineralogical differences between the secondary deposits crystallising on the surface of the membranes point to the impact of several factors, including membrane characteristics, concentration polarisation, mass transport mechanisms, etc.
W pracy przedstawiono wyniki badań, z wykorzystaniem wód mineralnych oraz nanofiltracji. Zastosowano komercyjną membranę nanofiltracyjną NF-270 firmy Dow Filmtec oraz membranę oznaczoną jako NF-DK firmy GE. Filtrację prowadzono dla odzysku wody wynoszącego 50%, pod ciśnieniem transmembranowym w zakresie 0,8–2,0 MPa w układzie filtracji dead-end. Dodatkowo permeat uzyskany w nanofiltracji filtrowano przez kolumnę wypełnioną skałą wapienną o frakcji 1,0–3,0 mm, w celu poprawy składu mineralnego wody. Badana woda mineralna posiadała charakter wody siarczanowo-chlorkowo-sodowo-magnezowo-wapniowej, natomiast permeat po NF wykazywał chlorkowo-sodowo-potasowy typ hydrogeochemiczny. W wyniku uzdatniania wody w procesie NF, uzyskano wysoką redukcję jonów SO4 – 96–98%, natomiast TDS zostało obniżone o ok. 51–64%. Ponieważ proces nanofiltracji pozwala na stosunkowo wysoką redukcję jonów dwuwartościowych, uzyskano również znaczące obniżenie zawartości jonów wapnia (84–88%) i magnezu (84–89%). Jony jednowartościowe obniżone zostały w mniejszym stopniu, tj. sód (46%), a wodorowęglany (49–51%). Filtracja permeatu, po membranie DK-NF, na złożu CaCO3, doprowadziła do korekty typu hydrogeochemicznego permeatu, z chlorkowo-sodowo-potasowego na chlorkowo-wodorowęglanowo-sodowy. Na podstawie oceny morfologicznej osadów w obrazach SEM i ich składu chemicznego, na powierzchni membrany NF-270 stwierdzono obecność kryształów gipsu. Osady utworzone na powierzchni membrany NFDK miały zupełnie inny charakter. Stwierdzono skupiska tlenków/wodorotlenków żelaza i glinu. Nanofiltracja jest odpowiednią metodą pozwalającą na modyfikację smakową wody mineralnej.
Źródło:
Archives of Environmental Protection; 2017, 43, 2; 51-59
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined Ozonation - Nanofiltration for Mycoestrogens Removal from Water
Ozonowanie-nanofiltracja w usuwaniu mykoestrogenów z wody
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/204556.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mykoestrogeny
mikrozanieczyszczenia organiczne
ozonowanie
nanofiltracja
system zintegrowany
uzdatnianie wody
mycoestrogens
organic micropollutants
ozonation
nanofiltration
integrated system
water treatment
Opis:
The paper describes the effectiveness of mycoestrogen removal in an integrated ozonation - nanofiltration system for water treatment. The results were compared to those obtained for ozonation and nanofiltration carried out as single processes. It has been found that the effectiveness of mycoestrogen removal in the integrated system was higher than that observed for single ozonation. During ozonation, the removal of micropollutants was affected by the dose of an oxidizing agent and type of treated water. As far as nanofiltration is concerned, its effectiveness both in the integrated system and as a single process was similar. Nevertheless, it is advisable to precede nanofiltration with ozonation because of membrane efficiency.
W pracy przedstawiono efektywność usuwania mykoestrogenów w zintegrowanym układzie oczyszczania wody ozonowanie - nanofiltracja. Wyniki badań porównano do wyników uzyskanych podczas ozonowania i nanofiltracji, które realizowane były jako procesy pojedyncze. Określono, że efektywność usuwania mykoestrogenów w układzie zintegrowanym jest wyższa niż obserwowana w pojedynczym procesie ozonowania. W przypadku ozonowania na usuwanie mikrozanieczyszczeń ma wpływ dawka utleniacza i rodzaj oczyszczanej wody. Z kolei efektywność nanofiltracji realizowanej jako proces pojedynczy i w układzie zintegrowanym pod kątem usuwania mykoestrogenów była zbliżona. Jednak biorąc pod uwagę wydajność membrany korzystniej jest proces nanofiltracji poprzedzić procesem ozonowania wody.
Źródło:
Archives of Environmental Protection; 2012, 38, 2; 103-109
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic risk assessment method : a proposal for assessing risk in water supply system
Metoda dynamicznego szacowania ryzyka : propozycja oceny ryzyka w systemie zaopatrzenia wody
Autorzy:
Fortmann-Roe, S.
Iwanejko, R.
Wójcik, W.
Powiązania:
https://bibliotekanauki.pl/articles/205339.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
risk
system dynamics
water treatment
waterborne pathogens
ryzyko
dynamika układu
uzdatnianie wody
patogeny wodorozcieńczalne
Opis:
System Dynamics is methodology for modeling and analyzing complex systems. Such systems can be characterized by interconnectedness and feedback. Applying risk assessment to the results of System Dynamics models is a challenge. Though in some cases the resulting time series data generated by a simulation may appear approximately random at a specific scale, there is often a high-degree of auto-correlation within the data series due to the deterministic nature of generation and feedback loops inherent in the system. This paper presents proposed Dynamic Risk Assessment Method (DRAM) that allows for the estimation of risk for system dynamics data series that appear to be approximately random. DRAM is based on standard risk assessment methods and is simple both to calculate and apply. In this article, the proposed method is applied to determine the risk connected with hypothetical costs of illness stemming from water supply system contamination with Cryptosporidium.
Dynamika Systemów jest metodologią modelowania i analizy złożonych systemów. Taki złożony system może być charakteryzowany przez wzajemne proste połączenia elementów oraz istniejące sprzężenia zwrotne. Przeprowadzenie oceny ryzyka przy modelowaniu Systemów Dynamicznych jest trudnym wyzwaniem. Chociaż w niektórych przypadkach, uzyskane za pomocą symulacji serie wyników mogą się wydawać przypadkowe, to jednak często istnieje wysoki stopień autokorelacji między tymi seriami wynikający z istnienia powiązań zwrotnych w systemie. Artykuł przedstawia propozycje Metody Dynamicznego Szacowania Ryzyka (MDSR), która pozwala oceniać ryzyko związane z hipotetycznymi kosztami zachorowań wywołanymi skażeniem systemu zaopatrzenia w wodę przez Cryptosporidium.
Źródło:
Archives of Environmental Protection; 2015, 41, 2; 36-40
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of Sludge from Mine Water Treatment Plant in The Segment of Thermal Insulation Mortars
Autorzy:
Václavík, V.
Daxner, J
Valíček, J
Dombek, V.
Dvorský, T.
Kušnerová, M
Václavíková, B.
Powiązania:
https://bibliotekanauki.pl/articles/204648.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mine water treatment
mine water
polyurethane
thermal insulation mortar
uzdatnianie wody kopalnianej
woda kopalniana
poliuretan
izolacja termiczna
Opis:
The results from the experimental research are presented in the abstract. The experimental research involved utilization of the sludge from the mine water treatment plant of Coal Quarry ČSA/Czechoslovak Army/ (hereinafter “ČSA”) and Coal Quarry Jana Švermy (hereinafter “JŠ”) in the segment of thermal insulation mortars. The mine water treatment is described below including chemical and mineralogical sludge composition as the additional component of the binding material in the polyurethane thermal insulation mortars. Furthermore the composition of experimental mixtures of the thermal insulation polyurethane mortar is presented in the work and its physical-mechanical properties. The monitored elements included the strength characteristics, heat conductivity coefficient λ, and water vapour diffusion coefficient μ.
Źródło:
Archives of Environmental Protection; 2014, 40, 1; 51-59
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study of hot mix asphalt containing water treatment and sewage sludge
Autorzy:
Bastidas-Martínez, J. G.
Camapum de Carvalho, J.
Lucena, L. C.
Farias, M. M.
Rondón-Quintana, H. A.
Powiązania:
https://bibliotekanauki.pl/articles/230585.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
osad
uzdatnianie wody
osad ściekowy
wypełniacz mineralny
mieszanka asfaltowa gorąca
water treatment
sludge
sewage sludge
mineral filler
hot mix asphalt
Opis:
Throughout the world, considerable quantities of water treatment sludge (WTS) and sewage sludge (SS) are produced as waste. This study assessed in the laboratory, the possibility to use both waste products when they are incorporated as filler at 1% with relation to the total mass of a hot mix asphalt - HMA. To this end, both waste products were initially reduced to ash through a calcination process. Resistance tests under monotonic load (Marshall and indirect tension tests), and cyclic load (resilient modulus test) were applied on mixes that contained WTS and SS. Besides, moisture damage (modified Lotmman test), and abrasion (Cantabro) resistance were assessed. An analysis of variance (ANOVA) test was performed in order to verify if the results are statically equal or not to those of the control HMA. As a general conclusion, it is reported that both materials show a resistance increase under monotonic load and higher stiffness under cyclic load (cohesion) when they are incorporated into the mix as filler despite the fact that the asphalt content used was less than the control mix. However, some problems are observed associated with moisture damage resistance, and friction wear (adherence).
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 225-240
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water and sewage sludge co-digestion : characteristic of the process and its possible applications
Współfermentacja osadów ściekowych i z uzdatniania wody : charakterystyka procesu i możliwości zastosowania
Autorzy:
Górka, Justyna Łucja
Cimochowicz-Rybicka, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/204961.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water treatment sludge
sewage sludge
co-fermentation
biogas
disintegration
dewatering
uzdatnianie wody
osad ściekowy
ko-fermentacja
biogaz
rozpad
odwadnianie
Opis:
The article describes problems related to intensification of energy production at a sewage treatment plant. The authors analyze anaerobic co-digestion of sludge from a water treatment plant and sewage treatment plant. The authors proposed a methodology of the research and analyzed the preliminary results, which showed that co-digestion of sewage and water sludge enhanced biogas production. The authors hope that the results of the study will provide a basis for development of methodology for sludge control and disposal.
Badania zaprezentowane w niniejszej publikacji, prowadziły do określenia możliwości wykorzystania osadów z uzdatniania wody jako substrat w procesie fermentacji metanowej osadów ściekowych. Autorzy zaproponowali metodologię badań i przeanalizowali wstępne wyniki, które wykazały, że dodanie osadów z uzdatniania wody do osadów ściekowych spowodowało zwiększoną produkcję biogazu. Zaproponowana technologia stanowi zintegrowany system gospodarki komunalnej, oparty na współpracy dwóch przedsiębiorstw: oczyszczalni ścieków i stacji uzdatniania, działających w systemie gospodarki cyrkulacyjnej. Rezultatem takiego rozwiązania są korzyści w zakresie odzysku biogazu, możliwego do wykorzystania w procesie kogeneracji.
Źródło:
Archives of Environmental Protection; 2019, 45, 1; 84-91
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative studies of coagulation in a batch and continuous mode systems
Badania porównawcze koagulacji w układzie porcjowym oraz przepływowym
Autorzy:
Mołczan, M.
Wolska, M.
Szerzyna, S.
Żółtowska, M.
Wiśniewski, J.
Adamski, W.
Powiązania:
https://bibliotekanauki.pl/articles/205234.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic matter
water treatment
DOC
color
coagulation jar test
UV absorbance
materia organiczna
uzdatnianie wody
kolor
jar test
absorbancja UV
Opis:
Coagulation studies were carried out simultaneously in a batch and continuous mode systems. Four coagulants of varied properties were used. Both test procedures contained the same process phases (rapid mixing, flocculation, sedimentation) and a corresponding coagulant dosage range (1.7–3.3 gAl/m3). In the batch mode test, the raw water composition was stable, while in the continuous mode test it was subject to changes resulting from natural variation in source water properties. The main process effectiveness measures were: color, absorbance at 254 nm, and dissolved organic carbon content. Studies in the batch mode system showed clear linear relationships between coagulant dosage and effectiveness of analyzed water contamination indicators values reduction. Tests in flow conditions confirmed the relationships found in the batch test, albeit with lesser agreement with a linear effectiveness – coagulant dosage model. Due to a comparison of coagulation results from both test systems, it was possible to determine the relationships between coagulation effectiveness obtained in continuous and batch mode systems. The linear relationships obtained show a dependence on current raw water properties and the type of coagulant used. However, in many cases, these relationships do not differ significantly as with respect to analyzed water quality indicators. The general rule is that the effectiveness observed in the continuous mode system is larger than that for the batch mode process, which is justified due to different process conditions. Determining the relationship between coagulation results obtained for different experimental procedures allows for predicting effects of changes in technical systems based on laboratory results.
Prowadzono jednoczesne badania koagulacji w układzie porcjowym oraz przepływowym. Korzystano z czterech koagulantów o zróżnicowanych właściwościach (polimeryzacja, zasadowość, zawartość glinu, koszt zakupu). Obie procedury badawcze zawierały te same fazy procesu (szybkie mieszanie, flokulację, sedymentację) oraz analogiczny zakres dawek koagulantów (1,7-3,3 gAl/m3). W teście porcjowym skład wody surowej był ustalony natomiast w badaniu przepływowym podlegał zmianom wynikającym z naturalnej zmienności charakterystyki ujmowanej wody powierzchniowej. Głównymi wskaźnikami oceny skuteczności procesu były: barwa, absorbancja w 254 nm oraz zawartość rozpuszczonego węgla organicznego. Badania w układzie porcjowym pokazały wyraźne liniowe zależności wiążące dawkę koagulantu ze skutecznością zmniejszania wartości analizowanych wskaźników zanieczyszczenia wody. Badania w warunkach przepływowych potwierdziły prawidłowości odnotowane w układzie porcjowym, jednak przy mniejszej zgodności uzyskanych wyników z liniowym modelem zależności skuteczności procesu od dawki koagulantu. Dzięki zestawieniu wyników koagulacji w obu układach doświadczalnych możliwe było określenie związków skuteczności koagulacji osiąganych w układzie przepływowym i porcjowym. Uzyskane liniowe przebiegi wykazują zależność od aktualnej charakterystyki oczyszczanej wody oraz rodzaju stosowanego koagulantu. Natomiast w wielu wypadkach nie różnią się istotnie w odniesieniu do analizowanych wskaźników jakości wody. Za regułę uznać można większą skuteczność koagulacji obserwowaną w układzie przepływowym wobec układu porcjowego, co znajduje uzasadnienie w różnych warunkach prowadzenia procesu. Ustalanie związków pomiędzy wynikami koagulacji uzyskiwanymi w różnych procedurach badawczych, a w szczególności w układzie porcjowym oraz przepływowym, pozwala na przewidywanie skutków zmian wprowadzanych w układach technicznych w oparciu o efekty doświadczeń laboratoryjnych.
Źródło:
Archives of Environmental Protection; 2018, 44, 3; 99-105
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of ceramic membranes for treating effluent water from closed-circuit fish farming
Zastosowanie membran ceramicznych do oczyszczania wód poprodukcyjnych z hodowli ryb w obiegach zamkniętych
Autorzy:
Bonisławska, M.
Nędzarek, A.
Drost, A.
Rybczyk, A.
Tórz, A.
Powiązania:
https://bibliotekanauki.pl/articles/204802.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Membrane filtration
fish farming
African catfish
water treatment
filtracja membranowa
hodowla ryb
sum afrykański
uzdatnianie wody
Opis:
The aim of the study was to analyze and assess the possibility of using a two-stage filtration system with ceramic membranes: a 3-tube module with 1.0 kDa cut-off (1st stage) and a one-tube module with 0.45 kDa cut-off (2nd stage) for treating effluent water from a juvenile African catfish aquaculture. The study revealed that during the 1st filtration stage of the effluent water, the highest degrees of retention were obtained with respect to: suspended solids SS (rejection coefficient RI=100%), turbidity (RI=99.40%), total iron (RI=89.20%), BOD5 (RI=76.0%), nitrite nitrogen (RI=62.30%), and CODCr (RI=41.74%). The 2nd filtration stage resulted in a lower reduction degree of the tested indicators in comparison to the 1st filtration stage. At the 2nd stage, the highest values of the rejection coefficient were noted in for the total iron content (RIV=100%), CODCr (RIV=59.52%; RV=64.28%, RVI=63.49%) and turbidity (RIV and RV = 45.0%, RVI=50.0%). The obtained results indicate that ceramic membranes (with 1.0 and 0.45 kDa cut-offs) may be used in recirculation aquaculture systems as one of the stages of effluent water treatment.
Celem pracy była analiza i ocena możliwości wykorzystania dwustopniowego systemu filtrowania z zastosowaniem membran ceramicznych w postaci modułu 3 rurowego o granicznej rozdzielczości membrany (z ang. cut-off) wynoszącej 1.0 kDa (I stopień) i modułu jednorurowego o granicznej rozdzielczości membrany wynoszącej 0.45 kDa (II stopień), do procesu oczyszczania wód poprodukcyjnych pochodzących z hodowli narybku suma afrykańskiego. Podczas I stopnia procesu filtracji wody poprodukcyjnej badania wykazały, że w najwyższym stopniu zatrzymywane były: zawiesina ogólna SS – RI= 100,0%, mętność RI=99.40%, zawartość żelaza ogólnego RI=89.20%, BZT5 RI=76.0%, oraz azot azotynowy RI=62.30% i ChZTCr RI=41.74%. II stopień procesu filtracji powodował mniejszy stopień redukcji wartości badanych wskaźników niż I stopień procesu filtracji. Wówczas najwyższy współczynnik retencji odnotowano w przypadku zawartości żelaza ogólnego RIV=100%, CODCr RIV=59.52%; RV=64.28%, RVI=63.49% i mętności RIV i RV= 45.0%, RVI=50.0%. Uzyskane wyniki wskazują na możliwość wykorzystania membran ceramicznych (o cut-off 1.0 i 0.45 kDa) w recyrkulacyjnych systemach akwakultury, jako jeden z etapów oczyszczania wód poprodukcyjnych.
Źródło:
Archives of Environmental Protection; 2016, 42, 2; 59-66
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies