Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wastewater treatment plant" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Sustainable sewage sludge management in Morocco: Constraints and solutions
Autorzy:
Ghacha, Abdessamad
Ben Allal, Laila
Ammari, Mohammed
Powiązania:
https://bibliotekanauki.pl/articles/293242.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
disposal
recovery
sewage sludge
sustainable management
wastewater
wastewater treatment plant
Opis:
The remarkable development of sanitation in Morocco has inevitably led to the production of sludge generated from wastewater treatment plants in increasing quantities. Consequently, the problem of sludge management becomes persistent and worrying. The aim of this paper was to contribute to the study of sewage sludge management issue in Morocco by identifying the various constraints hampering the sustainable disposal and/or recovery of municipal sewage sludge and drawing up recommendations for the decision-makers. Moreover, in the context of improving by learning from best practices and seeking common solutions regarding this problematic, benchmarking with other countries has been conducted as well. To carry out this study, a methodological approach was defined based on bibliographic research, surveys, interviews and benchmarking. The constraints hampering the sustainable management of sludge are numerous and complex, they have not been technical and environmental but also a regulatory, institutional-organizational and economic-financial nature yet. Therefore, municipalities, government and academia ideally would be encouraged to participate in the decision-making process regarding the management of sewage sludge. Technical solutions, when coupled with stakeholder participation, can lead to policy implementation with a higher chance of improving the present situation. In the case of Morocco, when comparing with others sludge recovery and disposal routes, land application (reuse in agriculture, silviculture and rehabilitation of degraded soils) remains the most environmentally friendly option, as well as a sustainable and economically viable solution.
Źródło:
Journal of Water and Land Development; 2020, 46; 71-83
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological reliability of sewage treatment plant with the Pomiltek Mann type bioreactor
Autorzy:
Kurek, Karolina
Bugajski, Piotr
Operacz, Agnieszka
Młyński, Dariusz
Wałęga, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/292901.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pollution indicators
technological reliability
wastewater treatment plant
Weibull method
Opis:
The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was performed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction (n) and treatment plant reliability factors (RF) were calculated. Average reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The reliability results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.
Źródło:
Journal of Water and Land Development; 2020, 46; 146-152
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków w przydomowej hybrydowej oczyszczalni hydrofitowo-biologicznej
The efficiency of wastewater treatment with the household hybrid (biological-constructed wetland) wastewater treatment plant
Autorzy:
Bergier, T.
Włodyka-Bergier, A.
Powiązania:
https://bibliotekanauki.pl/articles/339038.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie hydrofitowe
oczyszczanie ścieków
przydomowe oczyszczalnie
constructed wetlands
household wastewater treatment plant
wastewater treatment
Opis:
W artykule przedstawiono wyniki badań nad skutecznością usuwania zanieczyszczeń w przydomowej oczyszczalni ścieków komunalnych firmy Enko, zainstalowanej przy Urzędzie Gminy w Zawoi. Badaniom poddano ścieki surowe, ścieki po wstępnym oczyszczeniu i ścieki oczyszczone. Próbki pobierano co miesiąc, w okresie od listopada 2010 r. do czerwca 2011 r. Przeanalizowano zdolność usuwania w oczyszczalni Enkosystem substancji rozpuszczonych w postaci jonów (przewodność elektryczna właściwa), zawiesiny ogólnej, ogólnego węgla organicznego, BZT5, azotu ogólnego i fosforu ogólnego. Na podstawie uzyskanych wyników stwierdzono dużą, dochodzącą aż do 99%, skuteczność usuwania związków organicznych podatnych na biochemiczny rozkład (BZT5). Również dużą skuteczność usuwania zanieczyszczeń zaobserwowano dla zawiesiny ogólnej - od 74 do 95%. Ogólny węgiel organiczny również był usuwany ze stosunkowo dużą skutecznością (30-81%). Średnia skuteczność usuwania substancji rozpuszczonych w postaci jonów (mierzonych jako przewodność elektryczna właściwa) wynosiła 28%, natomiast fosforu ogólnego 41%. Najgorzej oczyszczalnia Enkosystem usuwała związki azotu - średnio o 27%. Oczyszczalnia Enkosystem pracowała prawidłowo, a wartości badanych wskaźników w zasadzie nie przekraczały wartości dopuszczalnych, zdefiniowanych w polskich przepisach prawnych.
The paper presents results of a study on the efficiency of a household hybrid wastewater treatment plant (WWTP) made by the Enko company, installed for the Town Hall in Zawoja. Samples of raw, pre-treated and treated sewage were analysed. The samples were taken every month, since November 2010 till June 2011. The following parameters were analysed: electrolytic conductivity, suspended solids, total organic carbon, BOD5, total nitrogen and total phosphorus. A high BOD removal efficiency of up to 99% was observed. Suspended solids were also removed with a high efficiency between 74% and 95%. Total organic carbon was removed with a relatively high efficiency (30-81%). The average removal efficiency for electric conductivity was 28%, and 41% for total phosphorus. The worst effects were noted for total nitrogen, the average removal efficiency of which was 27%. Enkosystem WWTP was characterized by proper performance, the values of analysed parameters did not in general exceed the standards defined by Polish legal regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 1; 25-36
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wastewater reuse and mapping of irrigable soils: Case of Sidi Bel Abbes City, Algeria
Autorzy:
Mahfoud, Zakaria
Khaldi, Abdelkader
Korichi, Khaled
Powiązania:
https://bibliotekanauki.pl/articles/293066.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bacteriology
physico-chemical parameters
reuse
soil
Sidi Bel Abbes City
wastewater
wastewater treatment plant (WWTP)
Opis:
This work aims to evaluate the treated wastewater from the activated sludge treatment plant in the City of Sidi Bel Abbes (North-Western Algeria) which is required for reuse in irrigation. The control of irrigated areas downstream is done based on a pedological study. Physico-chemical analysis such as (pH, BOD5, COD and SS) indicate results in Algerian and international standards required by the WHO. The Sodium Adsorption Ratio and Electrical Conductivity values of the treated wastewater belong to the C3-S1 class. The treated wastewater has a fairly good microbiological quality that meets Algerian standards. The helminth eggs are practically absent. The concentrations of heavy metals are much lower than the limits prescribed in the Algerian decrees. Therefore, the overall processing plant efficiency is satisfactory and has the characteristics of a good treated water quality for reuse in the field of irrigation while protecting the environment. The pedological study of the soil samples shows that the most dominant fraction is undeveloped calcimagnetic. The planned irrigation plain covers an area of about two thousand hectares. Depending on the crops to irrigate; the development and nature of the necessary or recommended improvements, the proposed irrigation perimeter could be classified into five categories in which only three categories are irrigable. Water projects have been proposed to ensure the irrigation of three subdivided sectors.
Źródło:
Journal of Water and Land Development; 2020, 46; 153-161
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of hydraulic load of a wastewater treatment plant in Jasło
Analiza obciążenia hydraulicznego oczyszczalni ścieków w Jaśle
Autorzy:
Młyński, D.
Chmielowski, K.
Młyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/292287.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
hydraulic load
sewage
sewage amount
wastewater treatment plant
ilość ścieków
obciążenie hydrauliczne
oczyszczalnie ścieków
ścieki
Opis:
The paper presents an analysis of hydraulic load in a wastewater treatment plant (WTP) in Jasło. The study was based on the records of daily sewage volume entering the treatment plant within a multi-year period of 2010–2014. The analysis took into account the average daily amount of incoming sewage, the maximum daily peaking factor for the incoming sewage, changes in the sewage volume depending on specific month and day of a week, and class intervals with the greatest frequency of occurrence. The analysis revealed that the average daily volume of the sewage entering the WTP in Jasło in the investigated multi-year period was 13 045 m3·d–1. The amount of incoming sewage was variable, as evidenced by the maximum peaking factors of daily sewage inflow that ranged from 1.07 to 2.78, depending on a specific month. The sewage admission was the largest in March, May and June and on Saturdays. Sewage volume interval most often occurring at the WTP in Jasło was the one between 8 000 and 10 000 m3·d–1. The study results indicated that the facility was hydraulically underloaded.
W artykule przedstawiono analizę obciążenia hydraulicznego oczyszczalni ścieków w Jaśle. Badania przeprowadzono na podstawie rejestrów dobowych objętości ścieków dopływających do oczyszczalni w wieloleciu 2010–2014. Wyznaczono średnią dobową ilość dopływających ścieków w badanym pięcioleciu, określono maksymalne współczynniki nierównomierności dobowej dopływu ścieków, kształtowanie się wielkości dopływu w poszczególnych miesiącach oraz dni tygodnia analizowanego wielolecia i wyznaczono przedziały klasowe, w których najczęściej pojawiały się dopływy ścieków. Na podstawie przeprowadzonej analizy stwierdzono, że średnia dobowa ilość ścieków dopływających do oczyszczalni w Jaśle w rozpatrywanym wieloleciu wynosi 13 045 m3·d–1. Ilość dopływających ścieków charakteryzuje się nierównomiernością, o czym świadczą wielkości maksymalnych współczynników nierównomierności dobowej dopływu ścieków, które w poszczególnych miesiącach przyjmowały wartości z przedziału od 1,07 do 2,78. Ponadto stwierdzono, że największe dopływy ścieków występują w miesiącach: marzec, maj, czerwiec, a w ciągu tygodnia – w soboty. Analiza częstości wystąpienia poszczególnych ilości ścieków dopływających do jasielskiej oczyszczalni wykazała, że najczęściej pojawiającym się dopływem był dopływ przyjmujący wartości z przedziału od 8 000 do 10 000 m3·d–1. Bazując na uzyskanych wynikach, stwierdzono, że oczyszczalnia ścieków w Jaśle pracuje w warunkach niedociążenia hydraulicznego.
Źródło:
Journal of Water and Land Development; 2016, 28; 61-67
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of wastewater purification in medium sand with a lightweight expanded clay aggregate assisting layer
Autorzy:
Kalenik, Marek
Wichowski, Piotr
Chalecki, Marek
Kiczko, Adam
Powiązania:
https://bibliotekanauki.pl/articles/27312642.pdf
Data publikacji:
2023
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
domestic wastewater infiltration drainage
domestic wastewater purification
individual wastewater treatment plant
individual WWTP
lightweight expanded clay aggregate
LECA
soil bed
Opis:
The objective of this experimental study was to examine whether an assisting layer of lightweight expanded clay aggregate (LECA) of the granulation 1-4 mm, introduced into a subsoil, is able to improve an efficiency of removal of total nitrogen and total phosphorus from domestic wastewater. In the investigations, an assisting 0.10 and 0.20 m thick LECA layer was applied. It has been observed that the effectiveness of removal of total suspended solids (TSS), total nitrogen and total phosphorus from wastewater as well as the level of biochemical oxygen demand (BOD5 ) and chemical oxygen demand (COD) is in accordance with the Polish standards on wastewater disposal into grounds and surface water. The performed experiments showed that the effectiveness of raw wastewater purification for the medium sand soil bed with the 0.20 m thick assisting LECA layer is higher than for the 0.10 m thick assisting layer. In the medium sand soil bed with the 0.20 m thick assisting LECA layer, the removal efficiency regarding total nitrogen increased by 20.6%, total phosphorus by 5.2%, ammonium nitrogen by 8.8% and TSS by 5.3%, and reduction efficiency regarding BOD5 increased by 1.7% and COD by 2.3% with relation to the 0.10 m thick assisting LECA layer (all percentages - in average). The results of the experiment showed that the LECA with the granulation 1-4 mm can be used to assist in removal of total nitrogen and total phosphorus from wastewater with application of infiltration drainage.
Źródło:
Journal of Water and Land Development; 2023, 57; 30--38
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of extraneous waters on the quality and loads of pollutants in wastewater discharged into the treatment plant
Wpływ wód przypadkowych na zmienność stężeń i ładunków zanieczyszczeń w ściekach dopływających do oczyszczalni
Autorzy:
Kaczor, G. B.
Chmielowski, K.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/292491.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
extraneous waters
i/i
sewage
sewage system
wastewater treatment plant
kanalizacja
oczyszczalnia ścieków
ścieki
wody przypadkowe
Opis:
The aim of the study was to analyze an influence of an inflow penetrating into two selected small sewerage systems during a rainy weather on pollutant concentration and load in raw sewage. Studies were conducted in 2010–2015 on two small sewerage systems in Małopolska province. The studies confirmed that the inflow penetrating into the sewerage systems resulted in a decrease of pollutant concentrations in sewage. However, they also showed that this dilution was not constant for all types of pollutants. The most important outcome of the study was demonstrating that despite its diluting effect on pollutants, the intense inflow into a sewerage system resulted in an increase of a sewage pollutant load. This increase was not regular, but it was rising dramatically when the inflow share in sewage exceeded 50%. The study indicated that the inflow penetrating into the sewerage system should not be disregarded, as it actually presented a significant threat to the wastewater treatment process and in consequence to the quality of recipient waters.
Celem badań było przeanalizowanie wpływu wód przypadkowych, dopływających do dwóch wybranych małych systemów kanalizacyjnych podczas pogody deszczowej, na stężenie i ładunki zanieczyszczeń w ściekach surowych. Badania prowadzono w latach 2010–2015 w dwóch małych systemach kanalizacyjnych funkcjonujących w województwie małopolskim. Przeprowadzone badania potwierdziły, że dopływy wód przypadkowych do kanalizacji powodują zmniejszenie stężenia zanieczyszczeń zawartych w ściekach. Jednakże rozcieńczenie to nie jest stałe w odniesieniu do wszystkich rodzajów zanieczyszczeń. Najważniejszym rezultatem badań było wykazanie, że – mimo rozcieńczenia ścieków – intensywny dopływ wód przypadkowych do kanalizacji sanitarnej powodował zwiększenie ładunków zanieczyszczeń w dopływie do oczyszczalni. Zwiększenie to nie było regularne, lecz gwałtownie przyrastające, gdy udział wód przypadkowych w ściekach przekraczał 50%. Wyniki badań wskazują, że dopływów wód przypadkowych do kanalizacji nie należy lekceważyć, gdyż stanowią one w rzeczywistości istotne zagrożenie dla procesu oczyszczania ścieków, a w dalszej kolejności – jakości wód w odbiorniku.
Źródło:
Journal of Water and Land Development; 2017, 33; 73-78
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena pracy zmodernizowanej oczyszczalni ścieków w Trepczy w województwie podkarpackim
The assessment of work of modernized wastewater treatment plant in Trepcza in podkarpackie voivodeship
Autorzy:
Młyńska, A.
Chmielowski, K.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/338998.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
jakość ścieków
modernizacja
oczyszczalnia ścieków
redukcja
wskaźniki zanieczyszczeń
modernization
pollutants indicators
reduction
sewage quality
wastewater treatment plant
Opis:
Niezależnie od jakości ścieków surowych dopływających do lokalnych oczyszczalni dąży się do tego, aby zachodzące w nich procesy oczyszczania zapewniały wymagany stopień eliminacji zanieczyszczeń. W przeciwnym razie może to wskazywać na potrzebę przeprowadzenia modernizacji obiektu. Oczyszczalnia ścieków komunalnych, będąca przedmiotem niniejszego opracowania, poddana została przebudowie m.in. w celu osiągnięcia lepszej skuteczności zachodzących procesów technologicznych. Na podstawie dokonanych w 2015 r. pomiarów wybranych parametrów fizykochemicznych ścieków surowych i oczyszczonych, obejmujących BZT5, ChZT, zawiesinę ogólną, azot ogólny (Nog.) i fosfor ogólny (Pog.), można stwierdzić, że modernizacja obiektu przyniosła zamierzony efekt. Każdorazowo oczyszczone ścieki odprowadzane do rzeki San spełniały wymagania jakościowe regulowane przez obowiązujące prawo, a wyznaczone średnie wielkości procentowej redukcji wskaźników zanieczyszczeń (RBZT5= 98,9%, RChZT = 94,0%, Rzaw.og.= 98,6%, RNog. = 85,0%, RPog. = 97,5%) świadczą o wysokiej efektywności zachodzących procesów oczyszczania.
Independently of the quality of raw sewage inflowing to domestic wastewater treatment plants, its aim to provide each time a required degree of pollutants elimination during sewage treatment processes. Otherwise, it can indicate on the need for the modernization of the object. Wastewater treatment plant which is a subject of this study was re-build, among others, in order to achieve better effectiveness of technological processes. As it turns out, basis on the performed in 2015 measurements of some physicochemical parameters of raw and treated sewage including BOD5, COD, total suspended solids, total nitrogen (Ntot) and total phosphorus (Ptot.), it can be stated that modernization of the analyzed treatment plant provided expected results. Namely, each time, treated sewage discharged to the San river, meet the quality requirements regulated by the applicable standards. Calculated average values of percentage reduction of pollutants indicators (RBOD5= 98.9%, RCOD= 94.0%, Rsusp.sol.= 98.6%, RNtot.= 85.0%, RPtot.= 97.5%) indicates on high effectiveness of technological processes of sewage treatment.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2017, 17, 4; 95-110
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operating household wastewater treatment plants in the light of binding quality standards for wastewater discharged to water bodies or to soil
Użytkowanie przydomowych oczyszczalni ścieków w świetle obowiązujących standardów jakości ścieków odprowadzanych do wód lub do ziemi
Autorzy:
Jawecki, B.
Pawęska, K.
Sobota, M.
Powiązania:
https://bibliotekanauki.pl/articles/946891.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
administrative decision
agglomeration
household wastewater treatment plant
sanitary sewage
stopping the operation of installation
wastewater treatment efficiency
aglomeracja
decyzja administracyjna
kanalizacja sanitarna
przydomowa oczyszczalnia ścieków
skuteczność oczyszczania ścieków
wstrzymanie eksploatacji instalacji
Opis:
The study presents the legal requirements concerning the quality of wastewater discharged to waterbodies and to soil after treatment in household wastewater treatment plants located in agglomerations or outside them. The procedure of stopping the operation of a household treatment plant that doesn't meet the statutory wastewater treatment efficiency was presented. The decision ordering to stop the use of a household wastewater treatment plant has to be preceded by a decision ordering to take measures to limit its adverse impact on the environment. The clarification procedure has to determine the adverse impact on the environment in a doubtless manner and it has to be reflected in the documentation. The assessment of adverse impact should take into account the binding standards of use of the environment. Stopping the operation of a household wastewater treatment plant may result in issuing a decision ordering the user to connect to the sanitary sewage system.
W pracy przedstawiono wymogi prawne, dotyczące jakości ścieków wprowadzanych do wód i do ziemi po oczyszczeniu w przydomowych oczyszczalniach ścieków zlokalizowanych na terenie aglomeracji lub poza nią. Wskazano procedurę wstrzymania eksploatacji przydomowej oczyszczalni ścieków, w sytuacji gdy nie spełnia ona wymaganej przepisami skuteczności oczyszczania ścieków. Decyzja o wstrzymaniu eksploatacji przydomowej oczyszczalni ścieków musi być poprzedzona decyzją nakazującą ograniczenie negatywnego oddziaływania przydomowej oczyszczalni ścieków na środowisko. Postępowanie wyjaśniające negatywne oddziaływanie na środowisko musi zostać stwierdzone w sposób niebudzący wątpliwości oraz znajdować odzwierciedlenie w dokumentacji postępowania, a ocena negatywnego oddziaływania na środowisko powinna uwzględniać obowiązujące standardy korzystania ze środowiska. Konsekwencją wstrzymania eksploatowanej przydomowej oczyszczalni może być wydanie decyzji nakazującej podłączenie się do kanalizacji sanitarnej.
Źródło:
Journal of Water and Land Development; 2017, 32; 31-39
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the stability and reliability of the water treatment plant in Nowy Sącz using control cards
Autorzy:
Śliz, Paulina
Bugajski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2073749.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
control cards
pollution reduction efficiency
stability of wastewater treatment
technological reliability
water treatment plant
Opis:
The subject of the study was to evaluate the stability and reliability of the sewage treatment plant in Nowy Sącz. The scope of the analysed indicators included the main indicators of wastewater contamination: BOD5(biochemical oxygen demand), CODCr (chemical oxygen demand), total suspended solids (TSS), total nitrogen (Ntot), and total phosphorus (Ptot). The operation stability of the sewage treatment plant in Nowy Sącz was determined on the basis of control cards x for 24 observations made in the period 2018-2019 (2 years). Moreover, the technological reliability of the tested sewage treatment plant (WN) was determined based on the values of the analysed pollution indicators in treated sewage and their permissible values. On the basis of the conducted analyses, full stability of the removal process of most of the analysed contaminants was found. In no case was there any crossing of the control lines, only a single grouping of samples above the help line in the case of total nitrogen, which could indicate a periodical disturbance in the stability of the removal process of this compound. On the basis of the obtained values of the reliability coefficient, which were below WN=1.00, reliable operation of the analysed facility was found, with a high degree of reduction (ƞ) of the analysed pollutants. The method of determining the technological reliability and stability of the treatment plant with the use of control cards is an effective and easy tool for detecting any disturbances and instabilities in the processes taking place in the tested facility. It enables the operator to take quick action to remove them, thus ensuring a safe wastewater treatment process for the environment and human health.
Źródło:
Journal of Water and Land Development; 2022, 52; 251--256
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of raw and purified wastewater reuse from the Dar El-Gueddari treatment plant on the soil
Autorzy:
Njimat, Smail
Elfettahi, Fouad
Griou, Hajar
El Brouzi, Mohammed Y.
Aboulouafa, Mohammed
Ibn Ahmed, Said
Powiązania:
https://bibliotekanauki.pl/articles/1844311.pdf
Data publikacji:
2021
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
dilutions
electrical conductivity
infiltration
organic matter
pH
treatment plant
wastewater irrigation
Opis:
The study has been carried out at two experimental sites. It aims to assess the impact of the reuse of raw wastewater, purified and diluted with conventional water on the physicochemical quality of soils compared to irrigated soils with conventional drilled water and non-irrigated soil. The obtained results show that the electrical conductivity EC and sodium gradually increase in all the plots irrigated with wastewater. Additionally, a slight increase in the pH levels at the first site and a slight decrease in the second site was seen, but at both sites the soils remained alkaline. The infiltration rate of water slide decreases in relation to the amount of irrigation, especially in plots irrigated by raw and treated wastewater. For the same plots, the values of organic matter increased, and the values obtained for the exchangeable sodium percentage (ESP) became high in the third year and reached 17.0% and 16.7% respectively.
Źródło:
Journal of Water and Land Development; 2021, 49; 121-128
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Gryfinie
Efficiency of sewage treatment plant in Gryfino
Autorzy:
Szczerbińska, N.
Gałczyńska, M.
Ulas, K.
Burczyk, P.
Mikołajczak, M.
Buśko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339125.pdf
Data publikacji:
2018
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
efektywność oczyszczania ścieków
oczyszczalnia ścieków
ścieki oczyszczone
ścieki surowe
efficiency of wastewater treatment purified sewage
raw sewage
sewage treatment plant
Opis:
Polska – wchodząc w struktury Unii Europejskiej – zobowiązała się do uporządkowania gospodarki ściekowej do końca 2015 r. Dzięki prawidłowej pracy oczyszczalni ścieki odprowadzane do wód odbiornika nie stanowią dla nich zagrożenia. Jest to szczególnie ważne ze względu na potrzebę utrzymania dobrego stanu wód powierzchniowych. Celem badań było określenie efektywności oczyszczania ścieków przez mechaniczno-biologiczną oczyszczalnię ścieków w Gryfinie na podstawie analizy ilości zanieczyszczeń niesionych wraz ze ściekami komunalnymi. Badania przeprowadzono na terenie oczyszczalni ścieków w Gryfinie. Analizy składu ścieków surowych i oczyszczonych obejmowały pięcioletni okres – od 2011 do 2015 r. Analizowano BZT5, ChZT, zawiesinę ogólną, Nog i Pog. Obliczono efektywność pracy oczyszczalni ścieków, skuteczność zmniejszania zanieczyszczeń i wskaźnik technologicznej sprawności oczyszczania. Wyniki badań opracowano statystycznie. Stwierdzono, że średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do zawiesiny ogólnej wyniósł 98,0%, BZT5 – na poziomie 98,9%, natomiast ChZT – na poziomie 97,4%. Średni wskaźnik sprawności oczyszczania ścieków w odniesieniu do azotu ogólnego oraz fosforu ogólnego wyniósł odpowiednio 89,6% i 96,4%. Ustalono, że efektywność oczyszczalnia ścieków w Gryfinie była bardzo duża i zgodna z przepisami.
Poland entering the structures of the European Union committed itself to organize wastewater management by the end of 2015. Due to the correct operation of the sewage treatment plant, the sewage discharged into the receiver water does not pose any danger to them. This is especially important because of the need to maintain good surface water quality. The aim of the study was to analyse the amount of pollutants transported with municipal wastewater, to determine the efficiency of wastewater treatment by mechanical-biological sewage treatment plant in Gryfino. The research was carried out on the sewage treatment plant in Gryfino. Analyses of raw and purified wastewater were carried on a five year period from 2011 to 2015. BOD5, COD, general suspension, total nitrogen and total phosphorus were analyzed. The efficiency of sewage treatment plant operation, efficiency of pollution reduction and the technological wastewater treatment efficiency rate were calculated. The results of the research were statistically analyzed. It was found that the average wastewater treatment efficiency rate for the total suspended solids was 98.0%, and BOD5 – 98.9%, and COD – 97.4%. The average efficiency index of wastewater treatment for total nitrogen and total phosphorus was 89.6% and 96.4% respectively. It was found that the efficiency of the wastewater treatment plant in Gryfino was very good and consistent with the regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2018, 18, 2; 85-98
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości oczyszczania ścieków bytowych w quasi technicznej instalacji zagrodowej typu IBMER na terenach górzystych
The quality of farm house-hold wastewater treatment in quasi-technical farmstead installation of IBMER model, in winter period on the mountainous terrain
Autorzy:
Jucherski, A.
Powiązania:
https://bibliotekanauki.pl/articles/238623.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczanie ścieków
obiekt gruntowo-roślinny
klimat
teren górzysty
oczyszczalnia zagrodowa
nitryfikacja
denitryfikacja
wastewater treatment
constructed wetland plant
mountainous climate
farm house-hold wastewater
nitrification
denitrification
ground-vegetable filtration media
Opis:
Przedstawiono wyniki dwuletnich (2005-2006) badań instalacji do oczyszczania ścieków bytowych o wydajności do 1 m3/d, koncepcji IBMER w Tyliczu, składającej się z 3.komorowego osadnika o pojemności czynnej 6 m3, urządzenia ze zraszanym złożem z granulatu ilasto-gliniastego (keramzyt) o powierzchni 2,5 m2 i stokowego złoża glebowo-darniowego o powierzchni 61 m2. Wskaźniki całorocznej skuteczności oczyszczania ścieków w tej instalacji - przy średnim dobowym dopływie 655 l - były znacząco wyższe od obowiązujących wymagań, a niekorzystne warunki zimowe wpływały ujemnie jedynie na efektywność usuwania azotu całkowitego. Średnie wartości wskaźników skuteczności zmniejszania wielkości i stężeń badanych składników zanieczyszczeń wynosiły: 97,9/97,9% BZT5; 94,3/89,2% ChZT; 97,2/99,5% N-NH4; 60,5/78,5% N-NC; 84,4/84,3% P-PO4 (zima/lato). Konieczne jest dalsze technologiczne doskonalenie urządzeń instalacji w celu zwiększenia efektywności denitryfikacji ścieków.
Paper described the results of two-year investigations (2005-2006) of the sewage treatment in single farm purifying installation of treatment output 1 m3 per day. The installation consists of 3 chamber settling tank of 6 m3 active capacity, the plant with sprinkled bed of light expanded clay aggregates (keramzit) of about 2.5 m2 surface and the slope soil-turf filtration bed of 61 m2 surface. The indices of all-year long wastewater treatment effectiveness in tested installation - at average wastewater inflow 655 I per day - were significantly higher than the compulsory requirements, and severe winter conditions affected only the efficiency of total nitrogen removal. Average indices of reducing pollutants quantity and concentration in treated wastewater amounted to: 97.9/97.9% - BOD; 94.3/89.2% - COD; 97.2/99.5% N-NH4; 60.5/78.5% Ntot; 84.4/84.3% P-PO4 (winter/summer). Further technological improvements of the installation would be necessary to increase the efficiency of sewage denitrification.
Źródło:
Problemy Inżynierii Rolniczej; 2007, R. 15, nr 2, 2; 51-60
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies