Variable dynamics of sewage supply to wastewater treatment plant depending on the amount of precipitation water inflowing to sewerage network
Zmienność dynamiki dopływu ścieków do oczyszczalni w aspekcie przedostawania się wód opadowych do systemu kanalizacyjnego
Autorzy:
Bugajski, P. M.
Kaczor, G.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/292612.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
precipitation
precipitation water
sewerage system
wastewater
opad atmosferyczny
system kanalizacyjny
ścieki
wody opadowe
Opis:
The paper analyzes the effect of precipitation water that inflowing to sanitary sewage system as accidental water on the changes in the total amount of treated sewage. The effects of accidental water supply on the total amount of sewage inflowing to treatment plant were analyzed based on mean daily amounts from the investigated periods and mean daily amounts from incidental supplies. The study was conducted in the years 2010–2015. Six characteristic research periods were identified (one per each calendar year), when the amount of sewage in the sanitary sewage system was greater than during dry weather. The analysis of changes in the amount of sewage supplied to the sewerage system in the six investigated periods revealed that the accidental water constituted from 26.8% to 48.4% of total sewage inflowing to the wastewater treatment plant (WWTP). In exceptional situations, during intense rains, the share of precipitation water in the sewerage system would increase up to 75%. Then, the rainwater inflowing the sewerage system caused hydraulic overloading of the WWTP by exceeding its maximum design supply.
W artykule przedstawiono analizę dotyczącą wpływu wielkości opadów atmosferycznych, które trafiają do kanalizacji sanitarnej jako wody przypadkowe, na zmienność ilości ścieków poddawanych procesom oczyszczania. Analizą dotyczącą wpływu wód przypadkowych na ilość ścieków dopływających do oczyszczalni objęto wartości średnie dobowe z badanych okresów oraz średnie dobowe dopływy ścieków z przypadków incydentalnych. Badania prowadzono w okresie od 2010 do 2015 roku, w którym wyróżniono 6 charakterystycznych okresów badawczych po jednym w każdym roku kalendarzowym, w których stwierdzono zwiększoną ilość ścieków w kanalizacji sanitarnej w porównaniu z ilością ścieków w kanalizacji w okresie pogody bezdeszczowej. W wyniku przeprowadzonej analizy dotyczącej zmienności ilości ścieków w kanalizacji w 6 okresach badawczych stwierdzono, że udział wód przypadkowych stanowił od 26,8 do 48,4% ogólnej ilości ścieków dopływających do oczyszczalni, natomiast w przypadkach incydentalnych w warunkach intensywnych opadów atmosferycznych udział wód opadowych w ogólnej ilości ścieków w systemie kanalizacyjnym wzrastał do 75%. W okresie badań w incydentalnych przypadkach wody opadowe przedostające się do kanalizacji powodowały przeciążenia hydrauliczne obiektu ponad dopływ maksymalny, na jaki została zaprojektowana oczyszczalnia.
Źródło:
Journal of Water and Land Development; 2017, 33; 57-63
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie przydomowe a zagrożenie środowiska wodnego
Water environment pollution and building on-site waste-water treatment systems
Autorzy:
Eymontt, A.
Rogulski, B.
Powiązania:
https://bibliotekanauki.pl/articles/239330.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ścieki
oczyszczalnia przydomowa
złoże
rozsączanie
wastewater
on-site system
bed
drainage
Opis:
Oczyszczalnie przydomowe ścieków bytowych są od kilkunastu lat wprowadzane na tereny wiejskie jako rozwiązanie alternatywne w stosunku do zbiorczych systemów oczyszczania ścieków. W wielu gminach, korzystając z liberalnych przepisów dotyczących ich budowy i eksploatacji, zastosowano rozwiązania grupowe, po kilkaset oczyszczalni w jednej gminie lub wsi, co stwarza zagrożenie dla środowiska wodnego i glebowego przy niewielkiej, wymaganej przepisami redukcji zanieczyszczeń w odprowadzanych, oczyszczonych ściekach. Dotychczasowe wyniki badań jakości odprowadzanych ścieków wykazały, że równolegle należy badać jakość wód gruntowych i podziemnych wokół oczyszczalni przydomowych, a szczególnie grup oczyszczalni, co pozwoli na określenie zakresu ich zastosowania. Na terenach wiejskich znajduje się większość zasobów wodnych i należy przeciwdziałać ich zanieczyszczaniu. W ocenie badanych oczyszczalni mogą być szczególnie przydatne normy i projekty tematycznych norm europejskich.
On-site waste-water treatment systems have been implemented on rural areas for several years as alternative solution to the typical canalization. In many gminas, availing of the liberal building and exploitation regulations treated about the on-site systems have been implemented grouped such a systems with a few hundred in one gmina or village. It causes great pollution water and soil environment, when pollution reduction level in treated waste-water, according to the existing regulations is very low. Up till now, measurement results of the quality of outlet waste-water from on-site systems showed us, that parallel should be measured quality of the surface and underground waters from around on-site systems, particularly groups of the on-site systems, what allows for the evaluation of the future scope of these systems building. It must be underlined, that on the rural areas are the greatest part of the water magazines, and we must prevent water pollution. In evaluation of the on-site systems will be very helpful European Standards and Standards Projects from that area.
Źródło:
Problemy Inżynierii Rolniczej; 2006, R. 14, nr 2, 2; 107-116
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of extraneous waters on the quality and loads of pollutants in wastewater discharged into the treatment plant
Wpływ wód przypadkowych na zmienność stężeń i ładunków zanieczyszczeń w ściekach dopływających do oczyszczalni
Autorzy:
Kaczor, G. B.
Chmielowski, K.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/292491.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
extraneous waters
i/i
sewage
sewage system
wastewater treatment plant
kanalizacja
oczyszczalnia ścieków
ścieki
wody przypadkowe
Opis:
The aim of the study was to analyze an influence of an inflow penetrating into two selected small sewerage systems during a rainy weather on pollutant concentration and load in raw sewage. Studies were conducted in 2010–2015 on two small sewerage systems in Małopolska province. The studies confirmed that the inflow penetrating into the sewerage systems resulted in a decrease of pollutant concentrations in sewage. However, they also showed that this dilution was not constant for all types of pollutants. The most important outcome of the study was demonstrating that despite its diluting effect on pollutants, the intense inflow into a sewerage system resulted in an increase of a sewage pollutant load. This increase was not regular, but it was rising dramatically when the inflow share in sewage exceeded 50%. The study indicated that the inflow penetrating into the sewerage system should not be disregarded, as it actually presented a significant threat to the wastewater treatment process and in consequence to the quality of recipient waters.
Celem badań było przeanalizowanie wpływu wód przypadkowych, dopływających do dwóch wybranych małych systemów kanalizacyjnych podczas pogody deszczowej, na stężenie i ładunki zanieczyszczeń w ściekach surowych. Badania prowadzono w latach 2010–2015 w dwóch małych systemach kanalizacyjnych funkcjonujących w województwie małopolskim. Przeprowadzone badania potwierdziły, że dopływy wód przypadkowych do kanalizacji powodują zmniejszenie stężenia zanieczyszczeń zawartych w ściekach. Jednakże rozcieńczenie to nie jest stałe w odniesieniu do wszystkich rodzajów zanieczyszczeń. Najważniejszym rezultatem badań było wykazanie, że – mimo rozcieńczenia ścieków – intensywny dopływ wód przypadkowych do kanalizacji sanitarnej powodował zwiększenie ładunków zanieczyszczeń w dopływie do oczyszczalni. Zwiększenie to nie było regularne, lecz gwałtownie przyrastające, gdy udział wód przypadkowych w ściekach przekraczał 50%. Wyniki badań wskazują, że dopływów wód przypadkowych do kanalizacji nie należy lekceważyć, gdyż stanowią one w rzeczywistości istotne zagrożenie dla procesu oczyszczania ścieków, a w dalszej kolejności – jakości wód w odbiorniku.
Źródło:
Journal of Water and Land Development; 2017, 33; 73-78
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie ścieków z małej przetwórni owocowo-warzywnej w złożach gruntowo-roślinnych z przepływem pionowym
Treatment of wastewaters from small fruit and vegetable processing plant in the reed bed systems with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/338470.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
oczyszczalnia hydrofitowa
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano skuteczność oczyszczania ścieków z małej przetwórni owocowo-warzywnej w 4 złożach gruntowo-roślinnych z przepływem pionowym, porośniętych trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-8 000 i 2 000-13 000 g O2·m-³. Największą skuteczność oczyszczania osiągnięto na wpracowanym złożu piaskowym, znoszącym zadowalająco obciążenia tą substancją wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i w ChZT - do ok. 110 g O2·m-²·d-¹. W przypadku wpracowującego się złoża piaskowo-żwirowego, wskaźniki te wyniosły tylko około 50 i 70 g O2·m-²·d-¹. Zastosowanie na takim samym złożu wzbogacania ścieków azotem, zmniejszającego stosunek BZT5 : N z około 200 do 70 powodowało zwiększenie wartości tych wskaźników odpowiednio do około 70 i 90 g O2·m-²·d-¹. Wyniki te osiągnięto, gdy temperatura odpływów ze złóż była większa niż 5°C. W przypadku temperatury 4-4,5°C wystarczającą skuteczność zapewniło zmniejszenie obciążenia złóż wyrażonego w BZT5 do ok. 50 g O2·m-²·d-¹ i w ChZT - do ok. 70 g O2·m-²·d-¹.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2007, T. 7, z. 2b; 177-184
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Całoroczne oczyszczanie ścieków z przetwórstwa owocowo-warzywnego w złożu hydrofitowym
Annual treatment of wastewater from small fruit and vegetable processing plant in the reed bed system with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339528.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
złoże hydrofitowe
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano całoroczną skuteczność oczyszczania ściekow z małej przetworni owocowo-warzywnej w piaskowym złożu hydrofitowym z przepływem pionowym, porośniętym trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-11 800 g O2·m-³ i 2 000-17 000 g O2·m-³. Skuteczność jej usuwania zależała w dużym stopniu od temperatury złoża. W temperaturze powyżej 5°C znosiło ono zadawalająco obciążenia wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i wyrażone w ChZT do ok. 130 g O2·m-²·d-¹. W temperaturze 3.5°C dopuszczalne okazały się obciążenia złoża wyrażone w BZT5 i ChZT odpowiednio do ok. 50 g O2· m-²·d-¹ i do ok. 70 g O2·m-²·d-¹. W temperaturze złoża 1-2°C dopuszczalne obciążenie wyrażone w ChZT wyniosło ok. 30 g O2 ·m-²·d-¹.
Annual efficiency was examined of the treatment of wastewater from small fruit and vegetable processing plant in a sandy hydrophyte bed with vertical flow overgrown by reed. The main pollutant in this wastewater poor in nitrogen and phosphorus was organic matter. Its concentration expressed in BOD5 and COD amounted to 1500–11 800 g O2·m-³ and 2000–17 000 g O2·m-³, respectively. The efficiency of its elimination depended to a large extent on reed bed temperature. At temperatures exceeding 5°C the reed bed satisfactorily withstood the load 90 g O2·m-²·d-¹ and about 130 g O2·m-²·d-¹ measured in BOD5 and COD, respectively. At temperatures of 3-5°C permissible organic matter loads were about 50 g O2·m-²·d-¹ and about 70 g O2·m-²·d-¹, respectively and at outflow temperatures of 1-2°C - 30 g O2·m-²·d-¹ expressed in COD.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2011, 11, 1; 289-298
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies