Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gas chromatography/mass spectrometry" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Quantitation of anticancer drugs – Cyclophosphamide and ifosfamide in urine and water sewage samples by gas chromatography–mass spectrometry
Autorzy:
Lekskulchai, Veeravan
Powiązania:
https://bibliotekanauki.pl/articles/2168354.pdf
Data publikacji:
2016-07-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
environment
cyclophosphamide
antineoplastic agents
gas chromatography–mass spectrometry
ifosfamide
sensitive and specificity
Opis:
Objectives Cyclophosphamide (CP) and ifosfamide (IF) are effective anti-cancer drugs but their genotoxicity can harm everyone contacting them occupationally or environmentally. Therefore, a sensitive method for monitoring their amounts in biological and environmental samples is needed. This has aimed to develop a method for analyzing these drugs in urine and water sewage samples. Material and Methods The drug spiked samples were extracted, derivatized, and analyzed by gas chromatography–mass spectrometry and the analytical parameters were validated. Results The method gave linear calibration curves at the concentrations of 0–190 nmol/l. It had the quantitation limit of 3.8 nmol/l and showed acceptable specificity, accuracy, recovery and precision. Conclusions The developed method can be used reliably for monitoring CP and IF concentrations in urine and water sewage. The method will be applied for preventing health risk from occupational and environmental exposures to these drugs. Int J Occup Med Environ Health 2016;29(5):815–822
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 5; 815-822
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acute methoxetamine and amphetamine poisoning with fatal outcome: A case report
Autorzy:
Wiergowski, Marek
Anand, Jacek
Krzyżanowski, Maciej
Jankowski, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2178876.pdf
Data publikacji:
2014-08-06
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
acute poisoning
methoxetamine (MXE)
amphetamine
fatal new drug intoxication
gas chromatography
mass spectrometry
Opis:
Methoxetamine (MXE) is a psychoactive substance distributed mostly via the Internet and is not liable to legal regulation in Poland. MXE has a toxicity profile similar to that of ketamine but longer-lasting effects. The paper describes a case of acute poisoning that resulted from recreational use of MXE and amphetamine and ended in death. In mid-July 2012, a 31-year old man was admitted to the clinical toxicology unit in Gdańsk because of poisoning with an unknown psychoactive substance. The patient was transported to the emergency department (ED) at 5:15 a.m. in a very poor general condition, in a deep coma, with acute respiratory failure, hyperthermia (> 39°C) and generalized seizures. Laboratory tests showed marked leukocytosis, signs of massive rhabdomyolysis, hepatic failure and beginning of acute renal failure. Despite intensive therapy, the patient died 4 weeks after the poisoning in the course of multi-organ dysfunction syndrome. Chemical and toxicological studies of serum and urine samples collected on the poisoning day at 1:40 p.m. confirmed that amphetamine and MXE had been taken earlier that day. Concentration of amphetamine in the serum (0.06 μg/ml) was within the non-toxic range, while MXE (0.32 μg/ml) was within the toxic range of concentrations. Amphetamine was also detected in the patient's hair, which suggested a possibility of its use within the last dozen weeks or so. The serious clinical course of intoxication and co-existence of amphetamine and MXE in the patient's blood and urine suggest the possibility of adverse interactions between them.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 4; 683-690
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda oznaczania 1,2:3,4-diepoksybutanu w powietrzu na stanowiskach pracy
Method for determining 1,2:3,4-diepoxybutane in workplace air
Autorzy:
Kowalska, Joanna
Jeżewska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2164260.pdf
Data publikacji:
2016-09-30
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
stanowisko pracy
czynnik rakotwórczy
analiza powietrza
chromatografia gazowa
spektrometria mas
diepoksybutan
workplace
carcinogens
analysis of air
gas chromatography
mass spectrometry
diepoxybutane
Opis:
Wstęp 1,2:3,4-Diepoksybutan (DEB) jest substancją zaklasyfikowaną do grupy substancji rakotwórczych. W Polsce nie ustalono wartości najwyższego dopuszczalnego stężenia dla tej substancji w powietrzu na stanowiskach pracy. W związku ze stosowaniem DEB w krajowych przedsiębiorstwach zaistniała potrzeba opracowania czułej metody oznaczania 1,2:3,4-diepoksybutanu w środowisku pracy. Materiał i metody Badania wykonano techniką chromatografii gazowej (gas chromatography – GC) przy zastosowaniu chromatografu gazowego Agilent Technologies 7890A sprzężonego ze spektrometrem mas 5975C (prod. Agilent Technologies, USA) i kolumny kapilarnej Rtx-5MS (30 m × 0,25 mm × 0,25 μm) (prod. Restek, USA). Wyniki Opracowana metoda oznaczania polega na przepuszczeniu znanej objętości badanego powietrza przez rurkę pochłaniającą wypełnioną węglem aktywnym w celu osadzenia na nim par 1,2:3,4-diepoksybutanu, desorpcji pochłoniętego DEB mieszaniną dichlorometanu i metanolu (95:5, v/v) i analizie tak otrzymanego roztworu. Krzywa kalibracji w zakresie stężeń 0,09–2,06 μg/ml jest liniowa (r = 0,999), co odpowiada zakresowi 5–114 μg/m³ dla próbki powietrza o objętości 18 l. Granica wykrywalności (limit of detection – LOD) wynosi 9,89 ng/ml, a granica oznaczalności (limit of quantification – LOQ) – 29,67 ng/ml. Wnioski Opisana metoda analityczna umożliwia selektywne oznaczenie 1,2:3,4-diepoksybutanu w powietrzu na stanowiskach pracy w obecności buta-1,3-dienu, 1,2-epoksypropanu, toluenu, styrenu i 1,2-epoksy-3-fenoksypropanu. Metoda charakteryzuje się dobrą precyzją i dokładnością oraz spełnia wymagania normy PN-EN 482:2012 dla procedur dotyczących oznaczania czynników chemicznych. Med. Pr. 2016;67(5):645–652
Background 1,2:3,4-Diepoxybutane (DEB) is a substance classified to a group of carcinogens. The maximum admissible concentration (MAC) value for this substance in workplace air is not specified in Poland. Due to the fact that DEB has been used in domestic companies there is a need to develop a sensitive method for determining 1,2:3,4-diepoxybutane in the work environment. Material and Methods The studies were performed using gas chromatography (GC) technique. An Agilent Technologies chromatograph, series 7890A, with a mass selective detector (5975C, Agilent Technologies, USA) was employed in the experiment. Separation was performed on a capillary column with Rtx-5MS (30 m × 0.25 mm × 0.25 μm) (Restek, USA). Results The developed method consists in passing the known volume of air through sorbent tube filled with activated carbon, desorpting the DEB vapor with dichloromethane/methanol mixture (95:5, v/v) and analyzing the obtained solution. The method is linear (r = 0.999) within the investigated working range of 0.09–2.06 μg/ml, which is equivalent to air concentrations of 5–114 μg/m³ for a 18 l air sample; limit of detection (LOD) − 9.89 ng/ml and limit of quantification (LOQ) − 29.67 ng/ml. Conclusions The described analytical method enables selective determination of 1,2:3,4-diepoxybutane in the workplace air in the presence of 1,3-butadiene, 1,2-epoxypropane, toluene, styrene and 1,2-epoxy-3-phenoxypropane. The method is characterized by good precision and accuracy and meets the criteria for measurement of chemical agents, listed in PN-EN 482:2012. Med Pr 2016;67(5):645–652
Źródło:
Medycyna Pracy; 2016, 67, 5; 645-652
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja metody oznaczania siarczanu dietylu na stanowiskach pracy
Optimization of the method for the determination of diethyl sulfate at workplaces
Autorzy:
Kowalska, Joanna
Jeżewska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2162475.pdf
Data publikacji:
2018-05-22
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
stanowisko pracy
czynnik rakotwórczy
analiza powietrza
chromatografia gazowa
spektrometria mas
siarczan dietylu
workplace
carcinogens
analysis of air
gas chromatography
mass spectrometry
diethyl sulfate
Opis:
Wstęp Siarczan dietylu (diethyl sulfate – DES) jest substancją zaklasyfikowaną do grupy substancji rakotwórczych. W Polsce nie ustalono wartości najwyższego dopuszczalnego stężenia dla tej substancji w powietrzu na stanowiskach pracy. W związku ze stosowaniem DES w krajowych przedsiębiorstwach zaistniała potrzeba opracowania czułej metody oznaczania siarczanu dietylu w środowisku pracy. Materiał i metody Badania wykonano techniką chromatografii gazowej (gas chromatography – GC) przy zastosowaniu chromatografu gazowego Agilent Technologies 7890A sprzężonego ze spektrometrem mas 5975C (prod. Agilent Technologies, USA). W badaniu wykorzystano kolumnę kapilarną Rtx-5MS (30 m × 0,25 mm × 0,25 μm) (prod. Restek, USA). Przebadano możliwość wykorzystania rurek pochłaniających zawierających: węgiel aktywny (100 mg/50 mg), żel krzemionkowy (100 mg/50 mg) oraz Porapak Q (150 mg/75 mg), do pochłaniania siarczanu dietylu. Wyniki Opracowano metodę pobierania próbek powietrza zawierających siarczan dietylu. Z sorbentów wybrano Porapak Q do pochłaniania par DES. Oznaczanie zaadsorbowanego DES polega na jego desorpcji mieszaniną dichlorometanu i metanolu (95:5, v/v) i analizie chromatograficznej tak otrzymanego roztworu. Krzywa kalibracji w zakresie stężeń 0,27–5,42 μg/ml jest liniowa (r = 0,999), co odpowiada zakresowi 0,0075–0,15 mg/m³ dla próbki powietrza o objętości 36 l. Wnioski Opisana metoda analityczna umożliwia selektywne oznaczenie DES w powietrzu na stanowiskach pracy w obecności siarczanu dimetylu, etanolu, dichlorometanu, trietyloaminy, 2-(dietyloamino)etanolu i N,N'-bis(2-aminoetylo)etylenodiaminy. Metoda spełnia wymagania normy PN-EN 482 dla procedur dotyczących oznaczania czynników chemicznych. Med. Pr. 2018;69(3):291–300
Background Diethyl sulfate (DES) is a substance classified to the group of carcinogens. The value of maximum admissible concentration for this substance in workplace air is not specified in Poland. Due to the use of DES in domestic companies there is a need to develop a sensitive method for the determination of diethyl sulfate in the work environment. Material and Methods Studies were performed using gas chromatography (GC) technique. An Agilent Technologies chromatograph, series 7890A, with a mass selective detector (5975C, Agilent Technologies, USA) was used in the experiment. Separation was performed on a capillary column with Rtx-5MS (30 m × 0.25 mm × 0.25 μm) (Restek, USA). The possibility of using sorbent tubes filled with activated carbon (100 mg/50 mg), silica gel (100 mg/50 mg) and Porapak Q (150 mg/75 mg) for absorption of diethyl sulphate was investigated. Results The method of sampling air containing diethyl sulfate was developed. Among the sorbents to absorb DES Porapak Q was chosen. Determination of the adsorbed vapor includes desorption of DES, using dichloromethane/methanol mixture (95:5, v/v) and chromatographic analysis of so obtained solution. Method is linear (r = 0.999) within the investigated working range of 0.27–5.42 μg/ml, which is an equivalent to air concentrations 0.0075–0.15 mg/m³ for a 36 l air sample. Conclusions The analytical method described in this paper allows for selective determination of diethyl sulfate in the workplace air in the presence of dimethyl sulfate, ethanol, dichloromethane, triethylamine, 2-(diethylamino)ethanol, and triethylenetetramine. The method meets the criteria for performing procedures aimed at measuring chemical agents, listed in EN 482. Med Pr 2018;69(3):291–300
Źródło:
Medycyna Pracy; 2018, 69, 3; 291-300
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies