Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ultra-performance liquid chromatography" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Optimization of ultra-performance liquid chromatography (UPLC) with fluorescence detector (FLD) method for the quantitative determination of selected neurotransmitters in rat brain
Autorzy:
Stragierowicz, Joanna
Daragó, Adam
Brzeźnicki, Sławomir
Kilanowicz, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2164059.pdf
Data publikacji:
2017-07-26
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
brain
neurotransmitters
glutamate
fluorescence detector
ultra-performance liquid chromatography
γ-aminobutyric acid
Opis:
Background Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. Material and Methods We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Results Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52–1.84%), inter-day precision (2.47–3.12%), limit of detection (5–30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. Conclusions The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583–591
Źródło:
Medycyna Pracy; 2017, 68, 5; 583-591
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring surface contamination for thirty antineoplastic drugs: a new proposal for surface exposure levels (SELs)
Autorzy:
Dugheri, Stefano
Mucci, Nicola
Bucaletti, Elisabetta
Squillaci, Donato
Cappelli, Giovanni
Trevisani, Lucia
Bonari, Alessandro
Cecchi, Michele
Mini, Enrico
Ghiori, Andrea
Tognoni, Daniela
Berti, Nicola
Alderighi, Francesca
Li Vigni, Nicola
Orlandi, Irene
Arcangeli, Giulio
Powiązania:
https://bibliotekanauki.pl/articles/2152946.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
health risk assessment
antineoplastic drugs
wipe test
ultra-high performance liquid chromatography
surface exposure level
tandem mass spectrometry
Opis:
Background Chemotherapy drugs are widely used to treat cancer, but their active compounds represent a danger for workers who could be exposed to them. However, they aren’t yet included in directive CE No. 1272/2008 and the European Biosafety Network has only recommended a limit value of 100 pg/cm2 for surface contamination. Thus, it is crucial to assess surface contaminations in healthcare environments. Currently, the technique of choice is surface wipe test combined with liquid chromatography tandem mass spectrometry to achieve high sensibility. Material and Methods A campaign involving Careggi University Hospital (Florence, Italy) was performed from January 2020 to December 2021, collecting 1449 wipe samples between administration units, preparation unit, and personnel gloves. From the obtained data, the 90th percentile was calculated for 30 antiblastic drugs and proposed as surface exposure levels (SELs); while from data concerning personnel glove contamination, weekly contamination was estimated. Results In the 2-year period only 417 wipe samples were found positive (28.8%), the majority of which regard samples coming from administration unit bathrooms. The proposed SELs are almost all <100 pg/cm2, except for few drugs which produce higher contamination on bathroom surfaces. Also, the estimation of pharmacy personnel’s glove contamination highlighted very low results (ng/week). Conclusions Deeply established protocols and procedures for safe handling of ADs allow for obtaining excellent cleaning results and thus a safer work environment, however, the risk of cytostatic contaminations cannot be avoided in healthcare workplaces, and thus a harmonization of classification and labeling of chemotherapy drugs throughout the European Union should be done.
Źródło:
Medycyna Pracy; 2022, 73, 5; 383-396
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies