Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Costa, F." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
A comparative study on the performance of radiation detectors from the HgI2 crystals grown by different techniques
Autorzy:
Martins, J. F. T.
Costa, F. E.
dos Santos, R. A.
de Mesquita, C. H.
Hamada, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/146916.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
crystal growth
iodide mercury crystal
physical vapor transport (PVT)
radiation detector
semiconductor crystal
Opis:
In this work, the establishment of a technology for HgI2 purification and crystal growth is described, aiming at a future application of this crystal as a room temperature radiation semiconductor detector. Two methods of crystal growth were studied in the development of this work: (1) physical vapor transport (PVT) and (2) saturated solution from dimethylsulphoxide (DMSO) complexes. In order to evaluate the crystals obtained using each of these methods, systematic measurements were carried out for determining the stoichiometry, structure, orientation, surface morphology and impurity of the crystal. The influence of these physicochemical properties of the crystals developed was evaluated in terms of their performance as a radiation detector. The best response to radiation was found for the crystals grown by the PVT technique. Significant improvement in the performance of HgI2 radiation detector was found, purifying the crystal by means of two successive growths by the PVT technique.
Źródło:
Nukleonika; 2012, 57, 4; 555-562
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an automation system for iodine-125 brachytherapy seed encapsulated by Nd:YAG laser welding
Autorzy:
Somessari, S. L.
Feher, A.
Sprenger, F. E.
Rostelato, M. E. C. M.
da Costa, F. E.
Calvo, W. A. P.
Powiązania:
https://bibliotekanauki.pl/articles/147664.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
iodine-125 seeds
prostate cancer
brachytherapy
Nd:YAG laser welding
Opis:
The aim of this work is to develop an automation system for iodine-125 radioactive seed production by Nd:YAG laser welding, which has been used successfully in low dose rate (LDR) brachytherapy treatment. This small seed consists of a welded titanium capsule, with 0.8 mm in diameter and 4.5 mm in length, containing iodine-125 adsorbed onto a silver rod. The iodine-125 seeds are implanted into the human prostate to irradiate the tumor for cancer treatment. Nowadays, the Radiation Technology Center, at Institute for Nuclear and Energy Research, Săo Paulo, Brazil (IPEN-CNEN/SP) imports and distributes 36,000 iodine-125 seeds per year, for the clinics and hospitals in the country. However, the Brazilian market potential is now over 8,000 iodine-125 seeds per month. The local production of these iodine-125 radioactive sources became a priority for the Institute, in order to reduce the price and the problems of prostate cancer management. It will permit to spread their use to a larger number of patients in Brazil. On the other hand, the industrial automation plays an important role for iodine-125 seeds in order to increase the productivity, with high quality and assurance, avoiding human factors, implementing and operating with good manufacturing practices (GMP). The technology consists of appliance electronic and electro-mechanical parts and components to control machines and processes. The automation system technology for iodine-125 seed production developed in this work was mainly assembled employing a programmable logic controller (PLC), a stepper motor, an Nd:YAG laser welding machine and a supervisory. The statistical repeatability of correctly encapsulated sealed sources with this automation system is greater than 95 per cent.
Źródło:
Nukleonika; 2011, 56, 4; 369-374
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
Autorzy:
Calvo, W. A. P.
Rela, P. R.
Napolitano, C. M.
Kodama, Y.
Omi, N. M.
da Costa, F.
de Andrade e Silva, L. G.
Powiązania:
https://bibliotekanauki.pl/articles/148041.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
multipurpose irradiator
gamma irradiator
compact irradiator
cobalt-60 irradiator
gamma facility
Opis:
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m2 of floor area, the irradiator design is a product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 PBq. The performed qualification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process qualification. The initial load of the multipurpose irradiator was 3.4 PBq with 13 cobalt-60 sources model C-188, supplied by MDS Nordion – Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The polymethylmetacrylate (PMMA) dosimeter system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning with dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial gamma irradiators available on the market.
Źródło:
Nukleonika; 2009, 54, 2; 93-97
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cost-effective approach to lung cancer risk for a radiological dispersal device (RDD) scenario
Autorzy:
Costa, Karolina P. S.
Lima, Sergio X.
Brum, Tercio
Lima, Zelmo R.
Amorim, Jose C. C.
Healy, Matthew J. F.
Vital, Helio C.
Prah, Matjaž
Andrade, Edson R.
Powiązania:
https://bibliotekanauki.pl/articles/146560.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
environment
contamination
radiation
cost-effectiveness
risk
Opis:
A release of radioactive material into the environment can lead to hazardous exposure of the population and serious future concerns about health issues such as an increased incidence of cancer. In this context, a practical methodology capable of providing useful basic information from the scenario can be valuable for immediate decisions and future risk assessment. For this work, the simulation of a radiological dispersal device (RDD) filled with americium-241 was considered. The radiation dose simulated by the HotSpot code was used as an input to the epidemiological equations from BEIR V producing the data used to assess the risk of lung cancer development. The methodology could be useful in providing training for responders aimed to the initial support addressed to decision-making for emergency response at the early phase of an RDD scenario. The results from the simulation allow estimating (a) the size of the potentially affected population, (b) the type of protection action considering gender and location of the individuals, (c) the absorbed doses, (d) the matrix of lung cancer incidence predictions over a period of 5 years, and (e) the cost-effectiveness in the initial decision environment.
Źródło:
Nukleonika; 2019, 64, 4; 123-129
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulated nuclear contamination scenario, solid cancer risk assessment, and support to decision
Autorzy:
Lima, Sergio X.
Costa, Karolina P. S.
Lima, Zelmo R.
Rother, Fagner C.
Araujo, Olga M. O.
Vital, Helio C.
Brum, Tercio
Junior, Wilson F. R. S.
Amorim, Jose Carlos C.
Healy, Matthew J. F.
Andrade, Edson R.
Powiązania:
https://bibliotekanauki.pl/articles/146554.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
improvised nuclear device
IND
induced cancer
risk assessment
decision
ocena ryzyka
decyzja
Opis:
The detonation of an (hypothetical) improvised nuclear device (IND) can generate atmospheric release of radioactive material in the form of particles and dust that ultimately contaminate the soil. In this study, the detonation of an IND in an urban area was simulated, and its effects on humans were determined. The risk of solid cancer development due to radiation was calculated by taking into account prompt radiation and whole-body exposure of individuals near the detonation site up to 10 km. The excess relative risk (ERR) of developing solid cancer was evaluated by using the mathematical relationships from the Radiation Effects Research Foundation (RERF) studies and those from the HotSpot code. The methodology consists of using output data obtained from simulations performed with the HotSpot health physics code plugging in such numbers into a specific given equation used by RERF to evaluate the resulting impact. Such a preliminary procedure is expected to facilitate the decision-making process significantly.
Źródło:
Nukleonika; 2019, 64, 2; 41-48
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies