Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "line" wg kryterium: Wszystkie pola


Tytuł:
Electromotive force induced in a loop conductor under a power line conductor
Autorzy:
Budnik, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/378317.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electromotive force
loop conductor
overhead power line
earth return
Opis:
The study presents methods of the calculation of electromotive force (emf) induced in a mitigation loop located under an overhead power line conductor. The loop can be treated as a rectangular loop (two-conductor closed mitigation loop) located near the power line horizontal to the earth surface. Exact and simplified methods of the determination of the emf are presented. The exact method bases on the earth return circuit theory, whereas the simplified method allows one to calculate the induced emf under the assumption neglecting earth currents.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 85-92
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energooszczędne moduły do zasilania LED-owych liniowych źródeł światła
Energy - efficient modules for supplying LED Line
Autorzy:
Gondek, J.
Kordowiak, S
Habdank-Wojewódzki, T.
Powiązania:
https://bibliotekanauki.pl/articles/377709.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
LED-owe liniowe źródła światła
LED Line
energooszczędne moduły elektroniczne
zasilacz diod LED
Opis:
LED-owe liniowe źródła światła znajdują coraz szersze zastosowanie w technice świetlnej, zastępując tradycyjne fluorescencyjne źródła światła. Charakteryzują się znacznie lepszymi parametrami technicznymi, w tym fotometrycznymi (efektywna skuteczność świetlna LED jest większa niż lamp fluorescencyjnych) [3], [7], [9], [10]. Do ich zasilania konieczne są energooszczędne moduły z układami automatyki i sterowania, umożliwiające współpracę z systemami oświetleniowymi.
The paper contain the result of research work out in Cracow University of Technology with AGH University of Science and Technology and Private Institute of Electronic Engineering. The works dedicated for elaboration modules for supplying LED Line. Electronics circuits ASICs are discussed. To perform the modules surface mount technology SMT and thick-film technology were used.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 219-225
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja parametrów mechanicznych układu dwumasowego w trybie on-line za pomocą rozmytego bezśladowego filtru Kalmana
On–line identification of mechanical parameters of two–mass system using fuzzy unscented Kalman filter
Autorzy:
Dróżdż, K.
Powiązania:
https://bibliotekanauki.pl/articles/376164.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
identyfikacja parametrów
filtr Kalmana
układ dwumasowy
systemy rozmyte
Opis:
Artykuł dotyczy zagadnień związanych z identyfikacją parametrów mechanicznych układu dwumasowego, przeprowadzanej w trybie on-line za pomocą rozmytego bezśladowego filtru Kalmana. W celu realizacji procesu identyfikacji zastosowano adaptacyjną strukturę sterowania rozważanego układu z dwoma dodatkowymi sprzężeniami zwrotnymi. Do klasycznego algorytmu UKF wprowadzono zaprojektowane systemy rozmyte, których zadaniem była adaptacja wyrazów macierzy kowariancji filtru Kalmana. Poprawia to jakość identyfikacji oraz przyspiesza ten proces. W pracy przedstawiono przegląd literatury, model matematyczny rozpatrywanego układu napędowego, omówiono algorytm rozmytego bezśladowego filtru Kalmana oraz zastosowane systemy rozmyte. Następnie zaprezentowano wyniki badań i przeprowadzono porównanie jakości identyfikacji realizowanej przez oba algorytmy filtrów Kalmana.
In the paper issues related to the on-line identification of mechanical parameters of the two-mass system using fuzzy unscented Kalman filter are presented. In order to perform the identification process, an adaptive control structure with two additional feedbacks was used. To the classical algorithm UKF designed fuzzy systems were introduced. Their task was an adaptation of elements of the Kalman filter’s covariance matrices. It improves the quality of identification. In this paper a review of the literature, mathematical model of the two-mass system, UKF algorithm and designed fuzzy systems are discussed. Subsequently, the research results and comparison of the identification quality for considered Kalman filters are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 91; 121-132
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using the EMTP/ATP program for calculation of electric and magnetic field distribution under overhead line
Zastosowanie programu EMTP/ATP do obliczania rozkładu pól i elektrycznych i magnetycznych pod linią napowietrzną
Autorzy:
Wiśniewski, J.
Anderson, E.
Karolak, J.
Powiązania:
https://bibliotekanauki.pl/articles/376500.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric field
magnetic field
overhead line
EMTP-ATP
Opis:
This paper presents the method of calculation of the electric and magnetic fields under overhead transmission line with any number of circuits, phase positions, voltages and current loads. Calculations of this type usually require specialized and costly programs. The program EMTP/ATP is a royalty free tool to calculate the electric transient and steady states in complex power systems. You can use this program and through appropriate modeling the multi-phase wire system representing the line and measurement device calculate the strength of the electric and magnetic fields. The results of calculations are characterized by a very small error compared to the results obtained by using the specialized program. This method can be used with other popular engineering tools like Matlab/Simulink or PSCad.
W artykule przedstawiono metodę obliczeń pól elektrycznych i magnetycznych pod linią wysokiego napięcia o dowolnym układzie faz, liczbie torów, napięciach i obciążeniach. Obliczenia tego typu wymagają zwykle wyspecjalizowanych i kosztownych programów. Program EMTP/ATP jest bezpłatnym narzędziem do obliczania stanów ustalonych i nieustalonych w złożonych układach elektroenergetycznych. Można przy użyciu programu poprzez odpowiednie zamodelowanie układu wieloprzewodowego odwzorować układ pomiarowy pozwalający obliczyć wartość natężenia składowej elektrycznej i magnetycznej pola. Uzyskane wyniki obliczeń charakteryzują się bardzo małym błędem w stosunku do wyników uzyskanych wyspecjalizowanym programem. Metodę tę można stosować przy użyciu także innych szeroko rozpowszechnionych inżynierskich narzędzi jak Matlab/Simulink lub PSCad.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 73-80
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Filtration of digital signals using wavelets
Autorzy:
Łuczak, D.
Skrzypiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/376402.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wavelet transform
on-line filtering
Gaussian noise
digital signal
Opis:
The article constitutes a set of research referring to the removal of the noise of Gaussian distribution of signal using wavelet analysis. The thesis has been launched of presentation of existing analysis algorithms, starting of discrete transform related to Mallat’s algorithm, and ending with the selected methods on inverse wavelet transform. The task was carried out by using the simulation scripts of package Wavelet Toolbox in MATLAB. The studies of using on-line filtering algorithms has been undergone. The delay value, which was implemented by the various filtration methods, was determined through simulations. The inclusion of the comparison of results allows to evaluate the quality of filtration.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 85; 187-195
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza możliwości systemów SCADA w wersji off-line i on-line na przykładzie turbiny wiatrowej TACKE TW600
Comparative analysis of offline and online version of SCADA systems based on TACKE TW600 wind turbine
Autorzy:
Szmechta, M.
Boczar, T.
Szczyrba, T.
Powiązania:
https://bibliotekanauki.pl/articles/376730.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
SCADA
TACKE TW600
turbina wiatrowa
VISUPROfessional
Opis:
W artykule wykonano analizę porównawczą dwóch rozwiązań systemu SCADA, jakie mogą mieć zastosowanie dla turbin wiatrowych. Analizowanym rozwiązaniem w wersji off-line jest oprogramowanie VISUPROfessional firmy GE Wind Energy dedykowane dla elektrowni produkcji TACKE i GE. Rozwiązaniem typu on-line jest system oferowany jako gotowy produkt przez firmę Wind-Service.com Sp. z o.o. Należy podkreślić, że w pracach związanych z jego tworzeniem brali udział pracownicy naukowo-dydaktyczni i doktoranci Politechniki Opolskiej. W artykule dokonano analizy porównawczej obu rozwiązań z punktu widzenia ich zalet ale także ograniczeń, aspektów związanych bezpośrednio z ich eksploatacją ale przede wszystkim zwracając szczególną uwagę na wymierne korzyści z ich praktycznego zastosowania dla firm serwisujących inwestycje wiatrowe, a także zwiększenie korzyści ekonomicznych dla właścicieli i potencjalnych inwestorów elektrowni wiatrowych.
Due to the large number of investments in wind power in recent years in Poland, the solutions of SCADA systems introduced in the article play an increasingly important role in this sector. Generally, from the point of view of available solutions, SCADA systems which can be used to diagnose the state of operation, and support the decision making and control of wind power plants can be divided into two solutions, off-line and on-line. This paper made a comparative analysis of the two solutions that may be applicable for wind turbines of the type Tacke TW600. The paper presents a comparative analysis of the two solutions of SCADA systems from the point of view of their benefits but also limitations directly related to aspects of their operation but also paying particular attention to the tangible benefits of their practical application to companies servicing wind investment and increase economic benefits for owners and potential investors of wind power.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 219-226
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power losses in the three-phase gas-insulated line
Autorzy:
Szczegielniak, T.
Kusiak, D.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/376150.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high-current busduct
electromagnetic field
power losses
Opis:
This paper presents an analytical method for determining the power losses in the three–phase gas–insulated line (i.e., high-current busduct) of circular cross–section geometry which phase conductors are placed in vertex of a square. The mathematical model takes into account the skin effect and the proximity effects, as well as the complete electromagnetic coupling between phase conductors and enclosures (i.e., screens). The power losses produced by high-current busducts are usually calculated numerically with the use of a computer. However, the analytical calculation of the power losses is preferable, because it results in a mathematical expression for showing its dependences on various parameters of the line arrangement. Moreover, knowledge of the relations between electrodynamics and constructional parameters is necessary in the optimization construction process of the high-current busducts.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 89; 89-98
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental results of parallel connected inverters feeding medium voltage transformer
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/377860.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical transformer
line side inverter
inrush currents
inverter parallel operation
Opis:
Development of medium voltage, high power ship electrical installations on board of special purpose vessels, has led to use of grid side inverters along with step-up grid transformers. In this paper there is presented theoretical background and experimental results of two inverters in parallel connection feeding one 0,4/15 kV transformer.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 359-368
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power line magnetic field mitigation using a passive loop conductor
Autorzy:
Budnik, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/376311.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
magnetic field
electric field
electric power lines
Fourier transform
loop conductor
Opis:
The paper presents in a tutorial manner methods of the calculation of magnetic fields in vicinity of overhead electric power lines without and with passive mitigation loops. Exact and simplified methods of the determination of the magnetic field of a straight overhead conductor based on the Fourier transform technique are presented. The mitigation effects due to the passive loop are also investigated, whereas the mitigation loop can be treated as a rectangular loop (two-conductor closed mitigation loop) horizontal located under the power line. The decomposition of the magnetic fields in two components: magnetic field obtained in free space from the Biot-Savart law and the magnetic field produced by earth current shows that in practical cases the effects from earth currents can be neglected as compared with effects from line currents.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 137-145
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit analysis of LSPMS motor supplied with distorted voltage
Autorzy:
Barański, M.
Powiązania:
https://bibliotekanauki.pl/articles/378202.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
FE method
line start permanent magnet synchronous motor
distorted voltage
in–house software
Comsol package
Opis:
A line start permanent magnet synchronous motor (LSPMSM) supplied with distorted voltage is analysed. The study is based on the field–circuit model. The algorithm for solving the equations of the model is discussed. In the analysis of the selected states of the motor the non–linearity of the magnetic circuit and skewed slots of the rotor are taken into consideration. In order to verify the developed algorithm and software, among others the startup process of the motor has been examined. The electromagnetic torque and phase currents are calculated. The results of computations have been compared to the results obtained using the commercial FEM package Comsol Multiphisics. Selected results of simulation tests are shown.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 91; 287-297
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Własności falowe ekranu rzeczywistej współosiowej linii długiej
Wave properties of the screen of real coaxial long line
Autorzy:
Tarczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/376313.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
własności falowe
ekran rzeczywistej współosiowej linii długiej
metoda impulsowa
Opis:
W artykule przedstawione są wyniki pomiarów mających na celu zbadanie własności falowych ekranu rzeczywistej współosiowej linii długiej. Zbudowano układ odniesienia dla linii kablowej stosując rurę miedzianą grubościenną do wnętrza, której włożono badany kabel. Rurę wraz z kablem ułożono w okrąg o niedużej średnicy i ułożono tak, aby wszystkie zwoje stykały się ze sobą na całej długości. Ułożona w ten sposób rura stanowiła prawie idealny poziom odniesienia i tym samym nie wykazywała cech linii długiej. Wpływ poziomu odniesienia badano przez pomiar przemieszczania się impulsów napięciowych w przewodzie środkowym oraz ekranie kabla. Wynikami pomiarów są oscylogramy obrazujące przemieszczanie się impulsów napięciowych. Wyniki tych pomiarów będą wykorzystane do udoskonalenia lokalizacji miejsca uszkodzenia powłok kabli energetycznych i telekomunikacyjnych metodami impulsowymi.
The article presents the results of measurements to investigate the wave properties of screen real coaxial transmission line. Constructed system of reference for the cable line using thick-walled copper pipe to the interior, which tested the cable is inserted. The pipe with the cable was laid in a circle with a small diameter and arranged so that all the coils touch each other throughout. Arranged in this way the pipe was nearly perfect reference level and thus does not show the characteristics of long lines. Influence of the reference level has been studied by measuring the movement of voltage pulses in the line center and the cable screen. Measurement results are oscillograms showing the movement of voltage pulses. The results of these measurements will be used to improve the location of the damage to the coating power and telecommunication cables using pulse methods.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 149-154
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energooszczędny napęd z silnikiem synchronicznym o magnesach trwałych z łagodnym startem
Energy-optimal control of line start permanent magnet synchronous motor
Autorzy:
Pajchrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/378045.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
silnik synchroniczny
LSPMSM
PMSM
układ napędowy
Opis:
W artykule przedstawiono układ napędowy z silnikiem synchronicznym o magnesach trwałych z rozruchem bezpośrednim (LSPMSM) przeznaczony dla napędu wentylatora. Omówiony został algorytm sterowania silnika LSPMSM według zasady u/f oraz optymalizacja korekty napięcia zasilającego za pomocą algorytmu genetycznego, która zapewnia zmniejszone zużycie energii elektrycznej. Model układu opracowano w języku Matlab. Przedstawione wyniki badań symulacyjnych ilustrują poprawne działanie energooszczędnego układu napędowego z silnikiem LSPMSM dla napędu wentylatora.
This paper presents the drive system of line start synchronous motor with permanent magnet (LSPMSM) for fan application. There was presented to the motor u/f control algorithm for LSPMSM and optimization of the supply voltage using a genetic algorithm, which provides reduced power consumption. The model developed in Matlab. The simulation results illustrate the correct operation of energy-efficient of LSPMSM drive for fan applications.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 75; 135-140
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozpoznawanie oraz lokalizacja w obrazie przewodów linii wysokiego napięcia
Power line detection
Autorzy:
Kowalski, P.
Smyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/376446.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wykrywanie krawędzi
wykrywanie krzywych
wykrywanie przewodów wysokiego napięcia
aproksymacja kształtu przewodu
przetwarzanie obrazu
Opis:
W pracy przedstawiono opracowany algorytm rozpoznawania oraz lokalizacji przewodów linii wysokiego napięcia na podstawie obrazu horyzontalnego. Procedura detekcji przewodu została podzielona na trzy etapy. Pierwszy etap zawiera algorytm wykrywania krawędzi wykazujący największą czułość na krawędzie poziome, a jednocześnie brak czułości na krawędzie pionowe. Efektem jest znaczna redukcja liczby wykrytych krawędzi w porównaniu do algorytmów wykrywających krawędzie we wszystkich kierunkach ze stałą czułością. Drugi etap polega na filtracji wykrytych krawędzi oraz klasyfikacji punktów do dalszej analizy. Na podstawie lokalnych różnic między sąsiadującymi pikselami wstępnie odrzucane są miejsca zawierające przypuszczalnie szum lub tło. Finalna klasyfikacja punktów reprezentujących przewód dokonywana jest z wykorzystaniem algorytmu znajdującego najdłuższą ścieżkę. Ostatni, trzeci etap polega na lokalizacji przewodu poprzez aproksymację jego kształtu na podstawie sklasyfikowanych punktów. Kontur wykrytego przewodu uzupełniany jest zbiorem pikseli reprezentującym przerwane ścieżki, zwiększając w ten sposób dokładność finalnej aproksymacji. Procedurę wykrywania przewodu zrealizowaną przy użyciu poszczególnych algorytmów przetestowano dla zdjęć rzeczywistych przewodów elektrycznych i stwierdzono jej pełną skuteczność.
The paper presents the algorithm for recognizing and locating high voltage power lines with the use of horizontal images. The algorithm has the highest sensitivity to horizontal edges and at the same time is insensitive to vertical edges. The first stage includes an edge detection algorithm. The second stage involves filtering of detected edges and classifying the points for further analysis. Using gradient method, the regions containing noise or background are discarded. The final classification of pixels representing the line is made using the longest path detection algorithm. In the third stage a shape of the wire is approximated based on the set of selected points. Then the contour of the detected wire is constructed with a set of pixels representing interrupted paths, thus increasing the accuracy of the final approximation.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 96; 255-266
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena algorytmów zabezpieczeń admitancyjnych linii średnich napięć
Evaluation of admittance protection for medium voltage line
Autorzy:
Lorenz, J
Handke, J.
Kwapisz, A.
Staszak, B.
Powiązania:
https://bibliotekanauki.pl/articles/377876.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
zabezpieczenie admitancyjne
kryteria admitancyjne
sieć średniego napięcia
Opis:
W artykule przedstawiono wyniki prowadzonych w Instytucie Elektroenergetyki Politechniki Poznańskiej badań nad oceną skuteczności działania zabezpieczeń admitancyjnych od skutków jednofazowych zwarć z ziemią w sieciach średniego napięcia. Badania efektywności stworzonych algorytmów zabezpieczeniowych prowadzone są z wykorzystaniem sygnałów uzyskanych z modeli laboratoryjnych i rzeczywistych układów sieciowych. Opracowane modele zabezpieczeń admitancyjnych pozwalają na dobór istotnych parametrów algorytmów decyzyjnych. Zamieszczono wyniki analizy działania zabezpieczeń realizujących wybrane kryteria admitancyjne dla określonych przypadków zwarć doziemnych. Symulacje wykonano za pomocą pakietów oprogramowania EMTP.
The results of evaluation of the earth fault admittance protection efficiency in MV networks developed in the Institute of the Electrical Power Engineering at Poznań University of Technology are presented in this paper. Efficiency tests of developed protection algorithms are made with utilization of measurement signals acquired from models and from network systems. The model of admittance protection allows to determinate important parameters of decision making algorithm. The results of protection operating analyses for selected admittance criterion are included. Simulation are made with use of EMTP applications.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 70; 17-23
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies