Tytuł:
Układ do ciągłego monitorowania stanu technicznego przekładni zębatych
System for continuous measurement of technical state of cylindrical gears
Autorzy:
Tomaszewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157894.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temperatura
drgania
badania doświadczalne
temperature
vibration
expert system
experimental investigations
Opis:
W pracy zaprezentowano doświadczalną metodę wyznaczania diagnostycznych parametrów przekładni. Do analizy wykorzystano moduł pomiarowy Vibrex oraz własny system ekspercki. Badania doświadczalne przeprowadzono w warunkach przemysłowych.
In the paper the experimental method of measurements of diagnostics parameters are presented. For analysis the Vibrex module and expert system are used. The experimental investigations were performed in service (industrial) conditions.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 105-107
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele medyczne do badań doświadczalnych
Medical modelling for experimental tests
Autorzy:
Miechowicz, S.
Kudasik, T.
Markowska, O.
Powiązania:
https://bibliotekanauki.pl/articles/152319.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modelowanie medyczne
elastooptyka
badania eksperymentalne
medical modelling
photoelastic examinations
experimental tests
Opis:
W artykule przedstawiono zagadnienia związane z wykorzystaniem modeli medycznych wykonanych technikami szybkiego prototypowania do badań doświadczalnych metodą elastooptyczną. Przeprowadzono analizę porównawczą przydatności wybranych materiałów w badaniach elastooptycznych metodą światła przechodzącego. Przedstawiono przykładowe wyniki analizy doświadczalnej wybranych modeli struktur anatomicznych. Potwierdzono przydatność wybranych metod modelowania medycznego w zastosowaniach eksperymentalnych.
For the analysis of complex medical issues, besides numerical methods, one can simultaneously make use of experimental tests to verify the obtained results. In the case of an experimental test it is necessary to make physical models and to carry out verifying tests on them. The physical model of the examined object can be fabricated with Rapid Prototyping technology from 3D-CAD virtual model. The Physical Rapid Prototyping model enables identifying the medical problem more efficiently and reconstructing the pathological changes clearly for experimental tests. Based on the medical model of real anatomical structures it is possible to manufacture experimental models that reconstruct complex inner structures very precisely. It allows avoiding simplified assumptions to experimental analysis. The photoelastic method can be used to verify the numerical analysis of the stress distribution in spatial models. The experimental research can be performed on real objects or their models. The photoelastic method is mainly used in cases where the stress distribution needs to be tested in those object areas that are difficult to access or the inner areas of structures. Some aspects of application of Rapid Prototyping (RP) methods to photoelastic tests are presented in this paper. The comparative analysis of the usefulness of available RP resin models applied to photoelastic experiment is performed. The process of preparation of an experimental model for the photoelastic method is described. The usefulness of the chosen RP resins for experimental tests is confirmed.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 4, 4; 203-206
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczalne wyznaczanie wybranych parametrów akcelerometrów MEMS - metodyka badań doświadczalnych
Experimental determination of selected parameters of MEMS accelerometers - methodology of experimental studies
Autorzy:
Łuczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/153697.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
akcelerometr MEMS
badania doświadczalne
pomiary
wzorcowanie
MEMS accelerometer
experimental studies
measurements
calibration
Opis:
W artykule przedstawiono problem doświadczalnego wyznaczania wartości najważniejszych parametrów metrologicznych akcelerometrów MEMS (Microelektromechanical Systems). Zaprezentowano odpowiednie stanowisko badawcze. Omówiono różne metody wzorcowania akcelerometrów. Zaproponowano dwie oryginalne procedury wzorcowania i podano odpowiadające im wartości niektórych parametrów metrologicznych uzyskanych dla przykładowego akcelerometru MEMS.
In the cases when metrological parameters of a sensor are of high importance, it is necessary to subject it to appropriate experimental studies. Generally, such a situation may take place when: significant metrological parameters of a sensor are not provided or may be overestimated in the related catalogs; a sensor must be calibrated by the user; an improvement of the sensor performance is striven for; significance of interactions between a sensor parameter and some disturbance must be verified; results of aging of a sensor, its durability or stability must be determined. Such cases are reported in [1-4]. While performing experiments described in the paper, two crucial issues were: an appropriate test rig presented in Section 2, and a methodology of performing the experiments discussed in the paper and in [8]. In Section 3 various ways of calibrating MEMS accelerometers are presented, with reference to related works of others, reported in [11-14], and their advantages and disadvantages are briefly discussed. Two original procedures of calibration are proposed. In the summary, the results obtained while calibrating the tested accelerometer according to three different methods are compared, and then a scope of application of each method is indicated. Further results of the considered experiments are reported by the author in the paper constituting a second part of the presented considerations, 'Experimental determination of selected parameters of MEMS accelerometers - results of the experimental studies'.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1321-1324
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary oporów przepływu dwufazowego w minikanałach
Measurements of two phase pressure drop in minichannels
Autorzy:
Dutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/156893.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
minikanały
opory przepływu dwufazowego
badania eksperymentalne
minichannels
two phase pressure drop
experimental investigations
Opis:
W artykule przedstawiono wyniki badań oporów przepływu mieszaniny woda-powietrze w minirurkach. W badaniach zastosowano 10 minirurek ze stali nierdzewnej o średnicy wewnętrznej dw = 0,64 ÷ 2,30 mm. Badania przeprowadzono w zakresie parametrów: masowe natężenie przepływu wody 0,15 ÷ 59 kg/h, powietrza 0,004 ÷ 0,7 kg/h, udział masowy powietrza w mieszaninie dwufazowej x = 0,0003 ÷ 0,22, gęstość strumienia masy mieszaniny (w?) = 46 ÷ 8582 kg/(m2os). Wykazano brak możliwości wykorzystania klasycznych metod obliczenia oporu przepływu dwufazowego.
The paper presents results of experimental investigations of frictional pressure drop in minichannels. Air-water mixture was used as working fluid. The test section was made from stainless-steel pipes of internal diameters equal to 0.64, 1.05, 1.10, 1.30, 1.35, 1.40, 1.60, 1.68, 1.94 and 2.30 mm. Investigations were performed for mass flux of 46 ÷ 8582 kg/(m2 s) and gas quality from 0.0003 to 0.22. The superficial velocity ranges of water and air were 0.1 ÷ 8.6 m/s and 0.9 ÷ 63.9 m/s, respectively. The results of experimental investigations were compared with the theoretical values obtained from the homogeneous equilibrium model (HEM). The dynamic viscosity coefficient was calculated using correlations proposed by: Owens, Mc Adams, Ackers, Cicchitti, Dukler, Beattie & Whaley, Lin. It was found that none of the tested correlations could predict the two-phase pressure drop satisfactorily. Even though there exist papers which confirm the suitability of the classical separated flow methods of Lockhart-Martinelli and Friedel for calculations of the frictional pressure drop of the two-phase flow in minichannels, the experimental study conducted by the author confirms the existence of substantial limitations. The classical correlations of Lockhart-Martinelli and Friedel can be only treated as primary estimation of resistances in the adiabatic two-phase flow in tubular minichannels. Experiments confirmed the need for introducing corrections and modifications to the classical method to obtain results reliable in case of minichannels.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 507-511
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania doświadczalne czujnika MEMS przy wykorzystaniu wibrometru laserowego
Experimental testing of MEMS pressure sensor using laser vibrometer
Autorzy:
Kasprowiak, M.
Jasiewicz, M.
Powałka, B.
Parus, A.
Powiązania:
https://bibliotekanauki.pl/articles/155986.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania doświadczalne
czujnik ciśnienia MEMS
wibrometr laserowy
experimental tests
MEMS pressure sensor
laser vibrometer
Opis:
W artykule przedstawiono problematykę doświadczalnych badań dynamicznych mikroukładów elektromechanicznych (MEMS) na przykładzie czujnika ciśnienia. Zaprezentowano stanowisko badawcze wykorzystujące wibrometr laserowy. W związku z trudnościami wymuszania dynamicznego MEMS zaproponowano metodę wzbudzania układu za pomocą przetwornika piezoelektrycznego a następnie porównano i omówiono wyniki badań uzyskanych przy zastosowaniu różnych sygnałów wymuszających.
The growth of technological capabilities in the field of manufacturing and machining of microelectromechanical systems (MEMS) results in the trend toward devices miniaturization. In many applications it is necessary to carry out experiments of MEMS (e.g. dynamic parameters identification), which in conjunction with miniature dimensions, turns out difficult [1]. Problematic is both a dynamic excitation of such structures vibrations recording. The paper presents the process and results of dynamic testing of MEMS structure using laser vibrometer. Section 2 presents test object, the pressure sensor, which was chosen due to the presence of a flexible diaphragm having a distinct form of vibration. In Section 3 the test stand, consisting of laser vibrometer, microscope, a PC with dedicated Polytec software and Signal Generator is described [3]. Due to impossibility of application of standard dynamic excitation (e.g. impact test or shaker) the piezoelectric transducer was proposed as an alternative [6]. The software enables generating both deterministic signals (e.g. Sine wave, Sweep, Square) as well as non-deterministic (Pseudo Random, Random Burst) by a signal generator coupled to the power supply. Section 4 includes the course of research and in Section 5 the comparison of test results for all applied excitation signals is presented. The summary and conclusions can be found in Section 6.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1084-1086
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary oporów przepływu jednofazowego w minikanałach
Measurements of single phase pressure drop in minichannels
Autorzy:
Dutkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/156887.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
minikanały
opory przepływu
współczynnik tarcia
badania eksperymentalne
minichannels
pressure drop
friction factor
experimental investigations
Opis:
W artykule przedstawiono wyniki badań dotyczących oporów jednofazowego przepływu wody (Re = 6 414) oraz powietrza (Re = 22 865) minikanałami. Jako minikanały zastosowano rurki ze stali nierdzewnej o całkowitej długości 500 mm i 15 różnych średnicach wewnętrznych (0,21 - 2,30 mm). Wyznaczono współczynnik strat liniowych podczas ruchu laminarnego, burzliwego i granicę przejścia z zakresu laminarnego w burzliwy. Wyniki badań porównano z wielkościami teoretycznymi znanymi z mechaniki płynów kanałów konwencjonalnych.
The paper presents results of experimental investigations of pressure drop in minichannels, with use of water and air as the working fluids. The test section was made from stainless steel pipes of internal diameters equal to 0.21, 0.31, 0.45, 0.55, 0.64, 0.80, 1.05, 1.10, 1.30, 1.35, 1.40, 1.60, 1.68, 1.94 and 2.30 mm. The experiments were conducted for the Reynolds number up to Re = 6 414 and Re = 22 865 for water and air, respectively. A friction factor is presented as a function of the Reynolds number. The experimental friction factor is compared with the results obtained from theoretical equations of Hagen-Poiseuille and Blasius. There was determined the boundary of transition to the turbulent flow. The deviation of all the results of experimental investigations was not greater than š 20% related to the friction factor coefficient theoretical value. On the basis of the experimental investigations performed, one can state that: - contradictory reports concerning a sooner transition to the turbulent flow different from those occurring in conventional channels were not confirmed; - the friction factor of laminar flow can be correctly predicted by the conventional correlation λ=64/Re; - the friction factor of turbulent flow can be correctly predicted by Blasius correlation, which is valid for conventional channels; - the theory of single-phase flow in conventional channels was found to produce valid predictions for experimental results.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 503-506
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki badań eksperymentalnych uniwersalnego estymatora / analizatora jakości energii elektrycznej w wersji 2.0
Experimental research results of universal estimator / analyzer of electrical power quality in the version 2.0
Autorzy:
Mindykowski, J.
Tarasiuk, T.
Maśnicki, R.
Górniak, M.
Szweda, M.
Powiązania:
https://bibliotekanauki.pl/articles/157485.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jakość energii elektrycznej
estymator / analizator
badania eksperymentalne
electrical power quality
estimator / analyzer
experimental research
Opis:
W pracy przedstawiono wybrane wyniki badań eksperymentalnych rozbudowanego, uniwersalnego estymatora/analizatora jakości energii elektrycznej w wersji 2.0. Artykuł dotyczy zagadnień związanych z oceną i poprawą jakości energii elektrycznej, zwłaszcza w izolowanych systemach okrętowych. W artykule krótko przedstawiono strukturę uniwersalnego estymatora/analizatora jakości energii elektrycznej w wersji 2.0, z podkreśleniem zmian konstrukcyjnych i funkcjonalnych w stosunku do wcześniej istniejącego rozwiązania, tj. estymatora/analizatora energii elektrycznej w wersji 1.0. Najważniejszą częścią przedstawionego artykułu jest syntetyczne omówienie trybów i wyników weryfikacji eksperymentalnej wykonanego urządzenia, podzielone na dwie części, dotyczące odpowiednio: badań laboratoryjnych wykonanych w Akademii Morskiej w Gdyni oraz prób środowiskowych wykonanych przez instytucję posiadającą właściwe uprawnienia akredytacyjne, tj. Centrum Techniki Morskiej.
In the paper some experimental research results of developed version 2.0 of the universal estimator/analyzer of electric power quality are presented. A subject matter of the paper concerns the issues connected with assessment and improvement of electrical power quality, in particular for applications in isolated ship power systems. In the article a structure of universal estimator/analyzer of electrical power quality in the version 2.0, taking into account the constructional and functional changes in relation to previously existing solution, i.e. the estimator/analyzer of electrical power quality in version 1.0 is shortly described. The most important part of the presented paper is synthetic discussion of the ways and results of the experimental verification of the elaborated device. This discussion is divided into two parts, concerning respectively laboratory tests carried out in the Gdynia Maritime University and environmental tests on marine equipment carried out by the appropriate accreditating institution it means Research & Development Marine Technology Centre - R&DMTC, Laboratory of Electromagnetic Compatibility.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 4, 4; 341-344
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar współczynnika przejmowania ciepła w warunkach odparowania rozprężnego czynnika chłodniczego
Measurement of the heat transfer coefficient during a refrigerant flashing flow
Autorzy:
Kruzel, M.
Dutkowski, K
Powiązania:
https://bibliotekanauki.pl/articles/155624.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania eksperymentalne
współczynnik przejmowania ciepła
minikanał
odparowanie rozprężne
experimental investigations
heat transfer coefficient
minichannel
flashing
Opis:
W artykule przedstawiono wyniki badań eksperymentalnych lokalnego współczynnika przejmowania ciepła. Wymiana ciepła odbywała się między ogrzewaną ścianką kanału a przepływającym wewnątrz czynnikiem chłodniczym (R134a i R404A). Wykorzystano 12, wykonanych ze stali nierdzewnej, rurek o średnicy wewnętrznej w zakresie dw = 0,64 ÷ 2,30 mm. Rurki tej średnicy, tzw. minikanały wykorzystuje się do budowy miniaturowych wymienników ciepła. Badania przeprowadzone w zakresie gęstości strumienia masy (wp) = 350 ÷ 1400 kg/(m2s) i gęstości strumienia ciepła dochodzącej do q = 90 kW/m2 pozwoliły zaobserwować występowanie, nie obserwowanego w kanałach konwencjonalnych, zjawiska flashingu. Wykazano, że w strefie objętej występowaniem zjawiska flashingu warunki wymiany ciepła pogarszają się, a wartość lokalnego współczynnika przejmowania ciepła w tej strefie może spaść nawet o 50%.
The paper presents the results of experimental investigations on the heat transfer coefficient. The heat was transferred between the heated channel wall and the refrigerant flowing inside the channel. Refrigerants R134a and R404A were used as a working fluid. During the experiments 12 tubes were used. The tubes were made of stainless steel and their inner diameter was: 0.45, 0.55, 0.80, 1.10, 1.15, 1.30, 1.35, 1.40, 1.60, 1.68, 1.94 and 2.30 mm. Channels with the above mentioned diameters are called minichannels and they are used to build miniaturized heat exchangers. The study was conducted in six series in which the mass flux density was changed (Table 1). During each series the heat flux density was stepwise increased and then decreased. Its maximum value was q = 90 kW/m2. This allowed obtaining the forced convection heat transfer or boiling phenomenon. In some cases, it was noted that the flashing phenomenon occurred. This phenomenon occurred when the local pressure was lower than the saturation pressure (at a given temperature). It revealed the evaporation of a liquid, not by applying heat from the wall, but by using the latent heat (heat of evaporation) [4, 5]. Reduction in the local pressure below the saturation pressure was common in minichannels. The reason is large pressure drops which occur in tubes of such small diameters. The flashing phenomenon was not observed inside conventional channels. The results of this study showed that in the zone of its occurrence the value of the local transfer coefficient decreased significantly (Figures 5 ÷ 8). During the experimental investigations the value of the local heat transfer coefficient decreased to 50%. From the conducted research it follows that the existence of the flashing phenomena in heat exchangers is harmful.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 10, 10; 879-882
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar mocy cieplnej pasywnego, powietrznego kolektora słonecznego
Measurement of thermal power of passive solar air collector
Autorzy:
Dutkowski, K
Piątkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/151292.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
powietrzny kolektor słoneczny
badania eksperymentalne
moc cieplna kolektora pasywnego
solar air collector
experimental investigations
heat efficiency
Opis:
W artykule przedstawiono wyniki badań eksperymentalnych prototypowego, powietrznego kolektora słonecznego. Badania przeprowadzono w warunkach laboratoryjnych. Ich celem było wyznaczenie wpływu natężenia promieniowania na przyrost temperatury powietrza oraz prędkość przepływu powietrza (na skutek ruchów konwekcyjnych). W efekcie pomiarów wyznaczono natężenie przepływu powietrza oraz moc cieplną kolektora. Pionierskie rozwiązanie konstrukcyjne jak i wyniki badań będą stanowiły punkt odniesienia dla wyników badań innych konstrukcji.
The results of experimental investigations of the prototype flat air solar collector are presented in this paper. The collector consists of an aluminum casing with dimensions 1.04 m (width) x 2.08 m (height) x 0.18 m (thickness). The air inlet to the collector has an inlet channel with diameter, din, of 110 mm and a length of 0.5 m. The air outlet channel has an internal diameter, dout, 130 mm and a length of 0.5 m. The prototype solar air collector has a cover made of a cellular polycarbonate with a thickness of 5 mm and in brown color. The study was performed on a laboratory set-up. The collector worked under conditions of natural convection. The tests were performed for a range of irradiance I = 0 - 325 W/m2. The absorber surface temperature variations, air temperature increase and the collector thermal power were determined. It was found that at maximum irradiation, the air velocity was w = 1 m/s, volume flow rate of air = 28 m3/h, and the corresponding heat transfer rate was Q = 270 W.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 10, 10; 868-871
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termograficzna ocena bezpiecznej odległości materiału palnego od przewodów instalacji odgromowej
Evaluation of safe distance between lightning protection system and combustible materials using thermal imaging
Autorzy:
Chybowski, R.
Ptak, S.
Bednarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/154522.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
instalacja odgromowa
materiał palny
kamera termowizyjna
badania eksperymentalne
lightning protection system
combustible material
infrared camera
experimental investigations
Opis:
W artykule przedstawiono wyniki badań bezpiecznej odległości pomiędzy materiałem palnym a instalacją odgromową. Badania przeprowadzono przy pomocy kamery termowizyjnej. Doświadczenia polegały na rozgrzaniu prądem pręta ze stali miękkiej o średnicy wymaganej w aktualnej normie i badaniu temperatury na powierzchni kartki papieru, modelującej powierzchnię materiału palnego. Arkusz umieszczano równolegle do odcinka drutu w różnych odległościach. Wyniki dowodzą, że dopuszczalne jest bezpieczne zmniejszenie odległości o co najmniej 20%.
This paper describes experimental research of a safe distance between combustible materials and a lightning protection system. The distance is required because of possible ignition of combustible materials as a result of thermal radiation emitted by the heated lightning protection wire. The euro - code which recently have became law in Poland determines the minimal distance to be at least 10 cm. Considering the phenomenon of lightning strikes, the required distance seems to be debatable. Experimental investigations were conducted on a test stand constructed in purpose to heat the steel wire using electricity. The temperature of about 800 °C was reached (Fig. 3) for both horizontal and vertical trials. A paper sheet was used to model the surface of combustible material and heated by infrared radiation emitted by a wire. The temperature of the paper sheet was measured using thermal camera (illustrated in Figure 4). The maximum temperatures of the paper sheet placed at various distances from the parallel heated wire are shown in Fig. 5. The study shows that even if a relatively high temperature is reached, it is safe to reduce the distance between a combustible material and a lightning protection system given by the mentioned euro - code.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1242-1244
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja doświadczalna analizatora jakości energii elektrycznej na statku m/s "Horyzont II"
Experimental verification of electrical power quality analyser on the ship m/s "Horyzont II"
Autorzy:
Tarasiuk, T.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157618.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
weryfikacja doświadczalna analizatora jakości
analizator jakości energii elektrycznej
experimental verification of electrical power
electrical power quality analyser
Opis:
W pracy przedstawiono strukturę i model fizyczny analizatora jakości energii elektrycznej opracowanego dla potrzeb energetyki okrętowej. Wspomniany model zrealizowany został z wykorzystaniem procesorów sygnałowych i przeszedł z wynikiem pozytywnym badania swoich właściwości w warunkach laboratoryjnych.Ostatecznej weryfikacji walorów użytkowych modelu dokonano na statku szkolno-badawczym Akademii Morskiej w Gdyni m/s "Horyzont II". W pracy przedstawiono wybrane przykłady przeprowadzonych badań.
Ii the paper the structure and physical model of the ships electrical power quality analyser has been presented. The above - mentioned model is based on the digital signals processing and it has been positively tested under the laboratoty conditions. The final verification of the operational properties of this device has been carried out on Gdynia Maritime University training ship m/v "Horizont II".
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 31-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zagrożenia piorunowego wybranych układów elektronicznych systemów kontrolno-pomiarowych
Research on lightning threat in selected electronic control and measuring systems
Autorzy:
Markowska, R.
Sowa, A.
Wiater, J.
Powiązania:
https://bibliotekanauki.pl/articles/157265.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowanie piorunowe
systemy kontrolno-pomiarowe
symulacyjne badania terenowe
lightning stroke
control and measuring systems
experimental simulation investigations
Opis:
Stworzenie kompleksowej ochrony urządzeń i systemów przed narażeniami piorunowymi wymaga przeanalizowania występującego zagrożenia oraz dobrania odpowiednich sposobów ochrony. Podstawowe informacje o zagrożeniu wywołanym przez rozpływający się prąd udarowy otrzymano prowadząc symulacyjne badania terenowe w rzeczywistych obiektach budowlanych. Porównując wyniki badań terenowych i obliczeń numerycznych opracowano modele matematyczne opisujące zjawiska zachodzące podczas bezpośrednich wyładowań piorunowych w urządzenia pioruno-chronne obiektów. Opracowane modele wykorzystano do określenia zagrożeń piorunowych wybranych układów kontrolno-pomiarowych.
Undisturbed operation of electronic equipment and systems requires complex analysis of lightning threats and careful selection of proper protection measures. Basic information on lightning threats resulting from surge current flows were obtained by conducting experimental simulation investigations of actual objects exposed to lightning [1-3]. In these experiments a surge generator was used as a source of the surge current. The generator was placed on the ground or on the analyzed object roof. It was connected to the object LPS and to its grounding system or auxiliary ground electrodes (Figs. 1, 2, 4, 6). Under such conditions, there were measured the surge current flows in conductive construction elements and equipotential bonding systems of the objects as well as the ground potential rises of these elements (Figs. 1, 3, 5, 6). The information obtained this way was then used for creating mathematical models of the phenomena observed during these experiments. Comparison of the measurement and calculation results allowed for developing the proper numerical representations of the analyzed objects, which then were used for creating mathematical models of various phenomena that may occur in these objects during natural lightning strikes to their LPS. The numerical analysis of these phenomena enabled determination of surge voltages and currents that arise in electronic control and measuring systems as a result of lightning current flows in the LPS of various buildings (Figs. 7, 8).
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 2, 2; 107-110
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental assessment of roundness profile measurement using the coordinate technique
Eksperymentalna ocena pomiaru zarysów okrągłości współrzędnościową techniką pomiarową
Autorzy:
Adamczak, S.
Jarema, M.
Powiązania:
https://bibliotekanauki.pl/articles/152534.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zarys okrągłości
pomiar
współrzędnościowa maszyna pomiarowa
eksperymentalny błąd metody
measurement
roundness profile
coordinate measuring machine
experimental method error
Opis:
Measurement laboratories in large production facilities with a stabilized and unchangeable production profile are equipped in accordance with the profile. In smaller companies where the profile is changeable, laboratories need to have more universal equipment. Frequently, a universal coordinate measuring machine is purchased to perform some basic tasks such as measurement of geometrical quantities, e. g. length or angle and assessment of selected parameters of geometrical surface structure, e.g. form and position deviation. The paper studies the accuracy of a typical coordinate measuring machine equipped with a pulse head applied to measurements of roundness profiles.
Duże zaklady przemysłowe o ustabilizowanym i niezmiennym profilu produkcji mają laboratoria pomiarowe wyposażone zgodnie z profilem swojej produkcji. Inna sytuacja jest w mniejszych firmach o zmiennym profilu produkcji. Tam laboratoria pomiarowe muszą być wyposażone w sprzęt pomiarowy o charakterze bardziej uniwersalnym. Rozwiązaniem tego problemu może być zakup współrzednościowej maszyny pomiarowej. Maszyny pomiarowe dzięki swojej uniwersalności stwarzają możliwość realizacji pomiarów podstawowych wielkości geometrycznych (dlugości i kąta). Umożliwiają również ocenić niektórych parametrów struktury geometrycznej powierzchni takich jak odchyłki ksztaltu i położenia. W artykule wyznaczono dokladność WMP w przypadku pomiaru zarysów okrągłoki dla typowej współrzednościowej maszyny pomiarowej wyposażonej w głowice impulsową.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 5, 5; 251-253
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar wybranych parametrów biomechanicznych w trakcie realizacji
Measurements of selected biomechanical parameters during experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D
Powiązania:
https://bibliotekanauki.pl/articles/153011.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
Opis:
Praca przedstawia jedną z metod badania osadzenia implantu w tkance kostnej. Opisano metodykę badań, dzięki której możliwa jest ocena jakości osadzenia implantu w tkance kostnej. W badaniach eksperymentalnych nowo poznawanych zjawisk kluczowe staje się odpowiednie dobranie aparatury pomiarowej. Poprawny dobór przyrządów pomiarowych pozwala na jednoznaczny opis badanego zjawiska lub obiektu.
The paper presents one of the methods of testing an implant mounting within the osseous tissue. It describes a methodology of the studies, which makes it possible to evaluate quality of the implant mounting within the osseous tissue. In the case of experimental studies of new phenomena being just investigated, it is crucial to appropriately select the measurement equipment. A correct selection of the measuring instruments allows one to unequivocally describe the studied phenomenon or object. A specific character of biomechanical properties of bones makes it impossible to carry out experiments using universal measuring machines, what results in a necessity of building custom test stations as well as special measure-ment systems based on well-developed measurement applications. As far as the described method of testing is concerned, there can be distinguished the following three stages:- the first, including preparations of the objects for the studies,- the second, including carrying out of measurements using the objects that have been prepared beforehand,- the third, including analytical determination of numerical values of the studied parameters. At the first stage, a minimum of the sample should be prepared, using an osseous tissue taken from a closer shaft of a cow thigh bone. After a pretreatment of the bone, a fragment of the tested mandrel should be mounted within it. The test station for experimental studies of the mandrel mounting within the osseous tissue must ensure a possibility of a real-time recording of the related displacements and load forces. The experiment was repeated many times in order to minimize the scatter of the indications. Basing on the obtained results, mutual correlations of particular data were determined, e.g. displacements of the mandrel within the bone in relation to the applied load. The obtained results make it possible to specify what kind of dynamics of the load applying influences the osseous tissue reaction rate.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 575-578
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niepewność jako miara poziomu zaufania do wyników procedur doświadczalnych
Uncertainty as a measure of the confidence level to results of experimental procedures
Autorzy:
Volodarskyi, I. T.
Kosheva, L. O.
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/154100.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
niepewność procedur eksperymentalnych
wartość wyniku badań
test
kontrola
prawdopodobieństwo poprawnych decyzji
uncertainty of experimental procedures
value of results
testing
control
probability of proper decisions
Opis:
Wykazano, że jakość procedur eksperymentalnych, takich jak zliczanie, kontrola oparta na pomiarach i badania właściwości substancji można charakteryzować poprzez szacowanie niepewności rezultatów tych procedur. Omówiono wpływ parametrów zmiennych kontrolowanych na rodzaj i prawdopodobieństwo niepoprawnych decyzji oraz niepewność kalibracji.
In this paper it is shown that it is possible to characterize the quality of the experimental procedures such as score of particles, control, testing, and research of material properties - all based on measurements, by using approaches based on estimating of the uncertainty of the results of these procedures. Formulas for uncer-tainty of these procedures are given. Also general formula of the probability of proper decisions based on the results of above proce-dures is given. Results of decisions for different relations between parameters of controlled variables are given in Table 1 and discussed in detail. Main conclusion is: such approach with estimation of the experimental procedure uncertainty can be used in practice to compare results of such procedures independently from their place and time of realization.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 483-485
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies