Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gazy" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
A new design of wet scrubber for removal of fine particles from exhaust gas
Autorzy:
Liao, B.
Juang, S. H.
Lin, H.
Powiązania:
https://bibliotekanauki.pl/articles/208160.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
cleaning methods
filter surface
solid particles
Venturi scrubber
combustion gases
płuczka Venturiego
cząstki stałe
metody oczyszczania
gazy spalinowe
Opis:
Bag-house dust collectors are commonly used in the industry for removing solid particles from dust laden gas. Bag house filter media need to be periodically cleaned in order to remove accumulated particles from the filter surface. Pulse jet cleaning is the most common cleaning method but produces noise increment of about 30-40 dB, which is its major disadvantage. The present study reports on a new type of combined wet scrubber-Venturi scrubber in the shape of a cyclone. The proposed design eliminates the noise associated with the pulse jet filter-cleaning process and filter bag replacement costs. The experimental results were demonstrated with high efficiency in the design.
Źródło:
Environment Protection Engineering; 2016, 42, 1; 59-70
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emission assessment at the Štepánovice municipal landfill focusing on CO2 emissions
Autorzy:
Vaverková, M.
Adamcová, D
Powiązania:
https://bibliotekanauki.pl/articles/207422.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gas emissions
landfill
emission concentration
landfill gas
municipal landfills
emisje gazów
składowisko
stężenie emisji
składowisko odpadów komunalnych
gazy wysypiskowe
Opis:
Emission concentrations from the landfill Štěpánovice have been examined. Measurements were carried out in the years 2004–2011. The results of the study were used to diagnose the emissions of CO2 as important landfill gas components. They indicate that the concentration of CO2 emissions and the annual sum of these emissions do not exceed the reporting thresholds and therefore, the landfill does not meet conditions for being included in the integrated register of polluters.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 111-123
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous removal of SO2 and NOx from sintering flue gas using ammonia-Fe(II)EDTA combined with electrolytic regeneration
Autorzy:
Liang, Y.
Yao, X.
Quin, L.
Chen, W.
Han, J.
Powiązania:
https://bibliotekanauki.pl/articles/208117.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ammonia
desulfurization
flue gases
nitrogen oxides
nitrogen removal
sintering sulfur dioxide
amoniak
odsiarczanie
gazy odlotowe
tlenki azotu
usuwanie azotu
spiekanie
ditlenek siarki
Opis:
Sulfur dioxide and nitrogen oxide are health hazardous gases, which contribute to the formation of submicron acidic particulates. To reduce SO2 and NOx emission from the sintering flue gas, the combination of ammonia-Fe(II)EDTA solution scrubbing with Fe(III) electrolytic regeneration is proposed. The above method has the following advantages: direct conversion of NOx and SO2 to harmless N2 and SO4 2−, recovery of the by-product (NH4)2SO4), simultaneous removal of NOx and SO2 emission from flue gas in the reactor. The effect of the pH, initial Fe(II)EDTA concentration, and voltage on the desulfurization and denitration efficiencies was investigated using a bench-scale reactor. The maximal desulfurization and denitration efficiencies were 98% and 52%, respectively. The optimum parameters were pH ˃ 5.0, 2.1 V, and 0.05 mol·dm–3 Fe(II)EDTA concentration. SO2 and NOx removal from the sintering flue gas by ammonia-Fe(II)EDTA solution scrubbing combined with electrolytic regeneration was also demonstrated in a pilot-scale reactor.
Źródło:
Environment Protection Engineering; 2018, 44, 2; 19-36
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentrations of carbon monoxide and nitrogen oxides from a 15 kW heating boiler supplied periodically with a mixture of sunflower husk and wood pellets
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/207042.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pelletizing
carbon monoxide
combustion chambers
flue gases
nitrogen oxides
pollutant concentration
heating boiler
granulowanie
tlenek węgla
komory spalania
gazy spalinowe
tlenki azotu
stężenie zanieczyszczeń
kocioł grzewczy
Opis:
The impact of periodic feeding mode on the concentrations of carbon monoxide (CO) and nitrogen oxides (NO, NOx) in the flue gas downstream the boiler was analyzed during firing of a mixture of sunflower husk and wood pellets in an overfeed furnace. The mixtures containing 100, 70 and 50 wt. %, of sunflower husk pellets were supplied to the boiler in two feeding modes: 1 s of operation 4 s of stand-by and 1s of operation 6 s of stand-by. Correlation between pollutant concentrations and the temperature in the combustion chamber was evaluated. The following concentrations of CO for various feeding modes and sunflower husk pellet proportions have been obtained: 1:6,100% - 6150 mg/m3,1:6,70% - 3360 mg/m3, 1:6, 50% - 2600 mg/m3, 1:4,100% - 4580 mg/m3,1:4, 70% - 2570 mg/m3, 1:4,50% - 870 mg/m3 for 10% O2 content in the flue gas. The study indicates the advisability of reducing the stand-by period in the pellet feeding system.
Źródło:
Environment Protection Engineering; 2014, 40, 2; 65-74
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomass as an answer to sustainable energy. Opportunity versus challenge
Autorzy:
Cao, Y.
Pawłowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/207977.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomass
energy conservation
fossil fuels
greenhouse gases
renewable energy resources
bio-mass energy
energy from biomass
renewable energies
sustainable energy
biomasa
oszczędność energii
paliwa kopalne
gazy cieplarniane
odnawialne źródła energii
energia biomasy
energia z biomasy
energetyka zrównoważona
Opis:
Current world economic development is heavily dependent on fossil fuels that are nonrenewable and are main emitter of the greenhouse gases, leading to resources to be exhausted on one side, and the earth being warmer on the other. This in turn creates a shrinking bottleneck to economic development and wealth generation. Therefore, in pursuit of a sustainable future, a shift from fossil fuels to renewable energy should be taken essentially. Biomass is an indispensable element for development of sustainable energy because it is the only renewable energy source that can be used to produce liquid fuel. In the paper, the sustainability of energy from biomass has been discussed, with the focus on an identification of its benefits and challenges. The necessity of deployment of biomass energy and its progress in China and Poland have also been described.
Źródło:
Environment Protection Engineering; 2013, 39, 1; 153-161
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of emission and reduction of greenhouse gases from upstream petrochemical industry in Thailand
Autorzy:
Kanchanapiya, P.
Julapun, N.
Limphitakphong, N.
Pharino, C.
Chavanparit, O.
Powiązania:
https://bibliotekanauki.pl/articles/207793.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
greenhouse gases
aromatic compounds
energy conservation
energy utilization
fuel economy
fuels
olefins
petrochemical plant
petrochemicals
petrochemical industry
production process
gazy cieplarniane
związki aromatyczne
oszczędzanie energii
wykorzystanie energii
zużycie paliwa
paliwa
olefiny
zakłady petrochemiczne
petrochemia
przemysł petrochemiczny
proces produkcji
Opis:
The study aimed to determine the baseline and indicators for the emission of greenhouse gases (GHG) and to evaluate the effectiveness of GHG mitigation measures in Thai upstream petrochemical plants. During 2005–2010, the upstream production had an annual demand for energy in the range of 110 000–150 000 TJ, ca. 5–6% of the total Thailand energy consumption. The proportion of energy consumption for producing olefin and aromatic products is 73 and 14%, respectively. The amount of GHG emissions equalled approximately 7–9 Mt CO2 eq. This represents a 3% portion of the total GHG emissions of Thailand, separating into the olefin and aromatic products, around 69 and 18%, respectively. The ratios of GHG emission came from fuel combustion of 59%, steam consumption (28%), electricity consumption (10%) and flare (3%). The carbon intensity of upstream products in the olefins and aromatics’ groups had the range of 1.125–1.309 and 0.518–0.667 t CO2 eq/t, respectively. It was likely that the carbon intensity during the period of 2005–2010 was lowered as the industry sector took measures to improve energy conservation and developed their production processes. The GHG mitigation measures by energy conservation were already implemented including fuel saving (67%), steam saving (23%) and electricity saving (10%).
Źródło:
Environment Protection Engineering; 2015, 41, 2; 31-46
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies