Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power loss" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Distributed generation’s integration planning involving growth load models by means of genetic algorithm
Autorzy:
Rahman, Y. A.
Manjang, S.
Yusran, A.
Ilham, A.
Powiązania:
https://bibliotekanauki.pl/articles/141167.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
genetic algorithm
load models
power loss
load growth
Opis:
The growth in the system load accompanied by an increase of power loss in the distribution system. Distributed generation (DG) is an important identity in the electric power sector that substantially overcomes power loss and voltage drop problems when it is coordinated with a location and size properly. In this study, the DG integration into the network is optimally distributed by considering the load conditions in different load models used to surmount the impact of load growth. There are five load models tested namely constant, residential, industrial, commercial and mixed loads. The growth of the electrical load is modeled for the base year up to the fifth year as a short-term plan. Minimization of system power loss is taken as the main objective function considering voltage limits. Determination of the location and size of DG is optimally done by using the breeder genetic algorithm (BGA). The proposed studies were applied to the IEEE 30 radial distribution system with single and multiple placement DG scenarios. The results indicated that installing an optimal location and size DG could have a strong potential to reduce power loss and to secure future energy demand of load models. Also, commercial load requires the largest DG active injection power to maintain the voltage value within tolerable limits up to five years.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 667--682
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GA based optimal planning of VAR sources using Fast Voltage Stability Index method
Autorzy:
Bhattacharyya, B.
Rani, S.
Vais, I. R.
Bharti, P. I.
Powiązania:
https://bibliotekanauki.pl/articles/140784.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power loss
FVSI method
genetic algorithm
operating cost
reactive power planning
weak nodes
Opis:
This paper presents a novel approach for reactive power planning of a connected power network. Reactive power planning is nothing but the optimal usage of all reactive power sources i.e., transformer tap setting arrangements, reactive generations of generators and shunt VAR compensators installed at weak nodes. Shunt VAR compensator placement positions are determined by a FVSI (Fast Voltage Stability Index) method. Optimal setting of all reactive power reserves are determined by a GA (genetic algorithm) based optimization method. The effectiveness of the detection of the weak nodes by the FVSI method is validated by comparing the result with two other wellknown methods of weak node detection like Modal analysis and the L-index method. Finally, FVSI based allocation of VAR sources emerges as the most suitable method for reactive power planning.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 789-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of smart transformer on different radialdistribution systems
Autorzy:
Mahmoud, Ibrahem Mohamed A.
Abdelsalam, Tarek Saad
Swief, Rania
Powiązania:
https://bibliotekanauki.pl/articles/1841278.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
smart transformer
smart grid
direct approach
power flow
power loss reduction
inteligentny transformator
inteligentna sieć
bezpośrednie podejście
przepływ mocy
redukcja strat mocy
Opis:
The work is intended to extend the application of a smart transformer on a radialdistribution system. In this paper, an updated algorithm on the backward/forward powerflow is introduced. The so-called direct approach of power flow is employed and analyzed.In addition, the paper focused on integrating a smart transformer to the network and solvingthe updating network also using the direct approach load flow. The solution of the smarttransformer using the direct approach power flow method is quite straightforward. Thismodel is applied to radial distribution systems which are the IEEE 33- and IEEE 69-bussystems as a case study. Also, the paper optimizes the best allocation of the smart transformerto reduce the power losses of the grid.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 271-283
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Trade based on alliance chain in energy from distributed photovoltaic grids
Autorzy:
Ding, Ran
Feng, Chaohan
Wang, Dongsheng
Sun, Rongfu
Wang, Longyang
Yuan, Shaojun
Powiązania:
https://bibliotekanauki.pl/articles/1841289.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
alliance chain
distributed photovoltaic grid
power transmission loss
pricing strategy
łańcuch sojuszu
rozproszona sieć fotowoltaiczna
straty w przenoszeniu mocy
polityka cenowa
Opis:
With the rapid development of distributed photovoltaic grids, more and more users join the power sales side, and the traditional power grid operation mode is no longer applicable. This paper analyzes the characteristics of the distributed photovoltaic grid under overload conditions, and further summarizes the problems that the distributed photovoltaic grid will face under these conditions. To solve these problems, the alliance chain technology was introduced into the distributed photovoltaic grid. At the same time, this paper establishes a photovoltaic pricing strategy that considers power transmission loss. Finally, the feasibility of the theory is verified by constructing a virtual model.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 325-336
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal allocation of DG units in distribution system considering variation in active power load
Autorzy:
Kumar, M.V. Likith
Bilgundi, Srishail K.
Pradeepa, H.
Powiązania:
https://bibliotekanauki.pl/articles/140424.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
exact loss formula
loss reduction
loss sensitivity formula
optimal DG placement
uncertainties in active power load
voltage profile
Opis:
High distribution system power-losses are predominantly due to lack of investments in R&D for improving the efficiency of the system and improper planning during installation. Outcomes of this are un-designed extensions of the distributing power lines, the burden on the system components like transformers and overhead (OH) lines/conductors and deficient reactive power supply leading to drop in a system voltage. Distributed generation affects the line power flow and voltage levels on the system equipment. These impacts of distributed generation (DG) may be to improve system efficiency or reduce it depending on the operating environment/conditions of the distribution system and allocation of capacitors. For this purpose, allocating of distributed generation optimally for a given radial distribution system can be useful for the system outlining and improve efficiency. In this paper, a new method is used for optimally allocating the DG units in the radial distribution system to curtail distribution system losses and improve voltage profile. Also, the variation in active power load in the system is considered for effective utilization of DG units. To evidence the effectiveness of the proposed algorithm, computer simulations are carried out in MATLAB software on the IEEE-33 bus system and Vastare practical 116 bus system.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 265-277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D loss and heat analysis at the end region of 4-poles 1150 MW nuclear power turbine generator
Autorzy:
Zhou, G.
Han, L.
Fan, Z
Liao, Y.
Huang, S.
Powiązania:
https://bibliotekanauki.pl/articles/950663.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
loss and heat
end region
4-poles nuclear power turbine generator
electromagnetic field
temperature field
Opis:
To study the principle of loss and heat at the end region of large 4-poles nuclear power turbine generator, 3D transient electromagnetic field and 3D steady temperature field finite element (FE) models of the end region are established respectively. Considering the factors such as rotor motion, core non-linearity and time-varying of electromagnetic field, the anisotropic heat conductivity and different heat dissipation conditions of stator end region, a 50 Hz, 1150 MW, 4-poles nuclear power turbine generator is investigated. The loss and heat at the generator end region are calculated respectively at no-load and rated-load, and the calculation results are compared with the test data. The result shows that the calculation model is accurate and the generator design is suitable. The method is valuable for the research of loss and heat at the end region of large 4-poles nuclear power turbine generator and the improvement of the generator’s operation stability. The method has been applied successfully for the design of the larger nuclear power turbine generators.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 47-61
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies