Tytuł:
Long lasting transients in power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97714.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inrush current
arc fumace transformer
harmonic filter
switching transient
Opis:
The practice of operating AC electrical arc fumace power supply systems has shown that energizing unloaded fumace transformer can cause long lasting transients in filter circuits of static VAR compensators used in the supply systems. Examination of the supply system configuration impact on switching transient behaviour has been carried out by example of a 50 MVA arc fumace unit. The transient analysis has been carried out through simulating by Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 324-333
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactive compensator synthesis in time-domain
Autorzy:
Siwczyński, M.
Jaraczewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201083.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power and energy theory
reactive power filters
reactive current
optimization
harmonic filter design
Opis:
The source reactive-current compensation is crucial in the energy transmission efficiency. The compensator design in a frequencydomain has already been widely discussed and examined. This paper presents results of a study on how to design reactive compensators in a time-domain. It is the first time the reactive compensator has been designed in a time domain. The example of a compensator is presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 1; 119-124
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients impact on power filter circuit sizing
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97523.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
transient and dynamic overvoltage
transient and dynamic overcurrent
equipment ratings
Opis:
The practice of operating multiple single-tuned filters in AC electrical arc furnace power supply systems has shown, that frequent energizing unloaded furnace transformer can cause damage of the filters. To examination of supply and filter system configuration impact on switching transient and dynamic overvoltages and overcurrents, an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink Software. Using ANSI/IEEE Standards paper focuses on the selections of ratings for capacitors and air-core reactors used in multiple single-tuned harmonic filters configurations. Comparison of filter reactor and capacitor bank design based on steady state operation and transformer energizing was shown.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 111-119
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ charakterystyk eksploatacyjnych sieci przemysłowych na dobór parametrów filtrów harmonicznych
Impact of industrial network operating characteristics on the harmonic filter parameters sizing
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/268765.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
filtr wyższych harmonicznych
stany ustalone
stany przejściowe
bateria kondensatora
dławik filtrujący
harmonic filter
steady state
transients
capacitor bank
air-core filter reactor
Opis:
Układy kompensacji mocy biernej oraz filtracji, oparte na kondensatorach znajdują powszechne zastosowanie w praktycznych rozwiązaniach systemów przemysłowych. Ich parametry znamionowe wyznaczane są wyłącznie w oparciu o harmoniczne prądów oraz napięć w stanach ustalonych, niemniej jednak tyczy się to głównie jednostek filtrujących o prostej topologii. Stąd, mając na uwadze bardziej złożone układy w większości przypadków istniejących lub nowoprojektowanych obiektów wymaga się, aby analizowane układy były dostosowane do pracy zarówno w warunkach ustalonych jak i przejściowych. Korzystając ze standardów oraz norm, w artykule omówiono procedurę doboru parametrów baterii kondensatorów oraz dławików układów filtrujących z pozycji ich bezawaryjnej pracy w elektrycznych sieciach przemysłowych. Zaproponowana metoda ma wspomóż działania projektowe filtrów harmonicznych.
The application of harmonic filter circuit based on power capacitor banks are widely used in practical solutions in industrial systems. The component ratings of these units are often specified based solely on a combination of steady state fundamental and harmonic voltages and currents. Although, this may be adequate in single-tuned or single branch units and method may not properly rate the components for more complex applications such as multiple, single-tuned harmonic filter circuits in compensated installations. Thus, in the most cases of commonly used or newly designed circuits are required to be adapted to operate as well in steady state and transients conditions. Using the exsisting Standards, the article propose a method for determining equipment ratings parameters of the capacitor banks and air-core filter reactors according to malfunctions. The study illustrated in this paper will be used to support and improve harmonic filter realiability and design. It is hoped that ideas will be a resource for a future filter application guide being contemplated by the capacitor subcommittee.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 47-51
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dwusekcyjny filtr piątej harmonicznej do kompensacji mocy biernej napędów walcarek rur
Bisectional 5th harmonic filter for reactive power compensation of pipe rolling mill drives
Autorzy:
Jagieła, K.
Gała, M.
Rak, M.
Kępiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1369646.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
dwusekcyjny filtr piątej harmonicznej
kompensacja mocy biernej
napęd
bisectionat 5th harmonic filter
reactiv power compensation
pipe rolling mill
Opis:
The article deals with a designed and practically applied bisectional passive filter that works as a reactive power compensator as well as suppresses the 5th harmonic of the supply voltage. There are presented calculations concerning harmonic currents in the supply power and in the switched sections of the 5th harmonic filter. The calculations are illustrated by diagrams of current transfer functions versus the harmonic order. In the second part of the article there are presented time variations of parameters of the electric Power consumed by a high power dc converter drive applied to a pipe rolling mill. These quantities include: Power factor tg?, the mean phase current in the supply circuit and the percentage content of the chase voltage 5th harmonic for different configurations of the filter compensator. The presented measurements and analysis allow to formulate conclusions and design recommendations.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 3, 96; 13-18
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast estimation of the non-stationary amplitude of a harmonically distorted signal using a Kalman filter
Autorzy:
Kovač, U.
Košir, A.
Powiązania:
https://bibliotekanauki.pl/articles/220868.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
amplitude estimation
harmonic signal
harmonic distortion
Kalman filter
Opis:
In this paper we introduce a self-tuning Kalman filter for fast time-domain amplitude estimation of noisy harmonic signals with non-stationary amplitude and harmonic distortion, which is the problem of a contactvoltage measurement to which we apply the proposed method. The research method is based on the self-tuning of the Kalman filter's dropping-off behavior. The optimal performance (in terms of accuracy and fast response) is achieved by detecting the jump of the amplitude based on statistical tests of the innovation vector of the Kalman filter and reacting to this jump by adjusting the values of the covariance matrix of the state vector. The method's optimal configuration of the parameters was chosen using a statistical power analysis. Experimental results show that the proposed method outperforms competing methods in terms of speed and accuracy of the jump detection and amplitude estimation.
Źródło:
Metrology and Measurement Systems; 2013, 20, 1; 27-42
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three phase active power filter with selective harmonics elimination
Autorzy:
Sozański, K.
Powiązania:
https://bibliotekanauki.pl/articles/141370.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
discrete fourier transform
harmonic distortion
power system harmonics
Opis:
This paper describes a three phase shunt active power filter with selective harmonics elimination. The control algorithm is based on a digital filter bank. The moving Discrete Fourier Transformation is used as an analysis filter bank. The correctness of the algorithm has been verified by simulation and experimental research. The paper includes exemplary results of current waveforms and their spectra from a three phase active power filter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 33-44
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
Autorzy:
Bielecka, Agata
Wojciechowski, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/135289.pdf
Data publikacji:
2020
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
shunt active power filter (SAPF)
harmonic compensation
reactive power compensation
prediction
closed-loop
open-loop
Opis:
This paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations were conducted in the PLECS program using a control algorithm written in C programming language.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2020, 61 (133); 9-16
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid-side current harmonic suppression based on Butterworth filter and quasi-proportional resonance controller
Autorzy:
Zhao, Feng
Zhang, Jianing
Chen, Xiaoqiang
Wang, Ying
Powiązania:
https://bibliotekanauki.pl/articles/2172801.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Butterworth filter
current harmonic suppression
high-speed electric multiple units
quasi-PR controller
traction drive system
Opis:
In order to meet the lightweight requirements of high-speed trains, the inductancecapacitance (LC) resonance circuits are cancelled in the traction drive system of some high-speed electric multiple units (EMUs) in China, which will lead to large low-order current harmonics on the grid side in the traction drive system of EMUs, seriously affecting the power quality. Therefore, the low-order harmonic current of the traction drive system of an EMU is studied in this paper. Firstly, the working principle of a four-quadrant pulse rectifier in a traction drive system is analyzed, and then the generation mechanism of loworder current harmonics on the grid side is studied deeply. Secondly, the voltage outer loop and current inner loop control of a four-quadrant pulse rectifier are optimized respectively. In the voltage outer loop control, a Butterworth filter is designed to suppress the beat frequency voltage of the DC side voltage, so as to indirectly suppress the low-order current harmonics. In the current inner loop, a quasi-proportional resonance (PR) controller with harmonic compensation is used to suppress low-order current harmonics, and a novel loworder current harmonics suppression strategy based on the Butterworth filter and quasi-PR controller is proposed. Finally, the results of the simulated validation of the proposed control strategy show that compared with the existing method of the notch filter ₊ PR controller, the proposed optimal control strategy has a better effect on low-order current harmonic suppression, and improves the dynamic performance of the control system, further showing the correctness and effectiveness of the optimal control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 909--929
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The DC-side active filter with dual-buck full-bridge inverter for wind generators
Autorzy:
Chen, X-Q.
Zhao, S-W.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/141358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-pulse ac-dc converter
auto-transformer
harmonic suppression
DC-side active filter
dual-buck full-bridge inverter
Opis:
This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional bridge-type inverters, and therefore this system with the character low harmonic distortion and high reliability. The proposed dc-side active filter is realized by using dual-buck full bridge converter, which directly injects compensation current at dc-side of two six-pulse diode bridges rectifiers. Compared with the conventional three-phase active power filter at ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping the diode bridges output current to be triangular without using the instantaneous reactive power compensation technology, only using simple hysteretic current control, even though under load variation and unbalanced voltage disturbances, and while an acceptable linear approximation to the accurate waveform of injection current is recommended. The performance of the system was simulated using MATLAB/Simulink, and the possibility of the dc-side active filter eliminating current harmonics was confirmed in steady and transient states. The simulation results indicate, the system has a total harmonic distortion of current reduced closely to 1%, and a high power factor on the wind generator side.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 263--277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fuzzy logic approach to shunt active power filter and hybrid active power filter
Autorzy:
Sahoo, Nirjharini
Panda, Gayadhar
Subudhi, B. D.
Powiązania:
https://bibliotekanauki.pl/articles/41189662.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
Index terms
shunt active power filter
hybrid active power filter
hysteresis current controller
total harmonic distortion (THD)
indirect current controller
filtr mocy czynnej
filtr hybrydowy
zniekształcenie harmoniczne
regulator prądu
Opis:
This paper describes a Fuzzy Logic approach to Shunt Active power filter (SAPF) versus Hybrid Active Power Filter (HAPF) using Simulink. Here hysteresis controlled PWM method is applied to the SAPF and HAPF as a current controller and Fuzzy logic controller as a inverter dc voltage controller. To reduce harmonics, Shunt Active Power Filters (SAPFs) are used with various control schemes, but Hybrid Active power filter is a power electronic device which has both the characteristics of passive power filters and active power filters, which helps in cancelation of the harmonics by producing compensating signal. The fuzzy-hysteresis controller is designed and its simulation results are presented for both the filter types, showing acceptable THD results for the word length used in the fixed-point computations involved in the switching sequence generation. The results of the above controller are compared with the Indirect current controller.
Źródło:
Journal of Power Technologies; 2023, 103, 4; 209-217
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies