Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "breakdown" wg kryterium: Temat


Tytuł:
Determining Maitenance Services Using Production Performance Indicators
Autorzy:
Szwedzka, K.
Jasiulewicz-Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/409212.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
maintenance
KPI
breakdown
stop time
production volume
Opis:
Increasing efficiency of machines and strong competition between companies, popularized the use of measures for maintenance service, designed to increase efficiency and reduce the costs of the machines usage. These indicators, help to achieve the reliability of production centers, eliminating potential events associated with electric, hydraulic and pneumatic failures. The aim of the work was to investigate the dependence of performance indicators used by the maintenance services, with the number of parts produced on automated production lines. Then assessed the relationship between the productivity of the line and the ratio of effective production time and how much time is spent on resolving the failure. Interpretation of measurement helped to make the joint improvement activities in the publication described production plants.
Źródło:
Research in Logistics & Production; 2016, 6, 4; 361-374
2083-4942
2083-4950
Pojawia się w:
Research in Logistics & Production
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obciążenia dynamiczne bębnów łańcuchowych w stanach awaryjnych przenośnika ścianowego
Dynamic load of chain drums in the breakdowns of a face conveyor
Autorzy:
Dolipski, M.
Remiorz, E.
Sobota, P.
Powiązania:
https://bibliotekanauki.pl/articles/186465.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
awaria
bęben łańcuchowy
obciążenia
breakdown
chain drum
load
Opis:
W wysoko wydajnych przenośnikach zgrzebłowych zainstalowanych w ścianach o dużej długości stan obciążenia napędów i układów łańcuchowych zmienia się w porównaniu ze ścianą konwencjonalną. Duże wartości maksymalne i amplitudy obciążeń dynamicznych w przenośniku mogą być przyczyną wystąpienia stanów awaryjnych, takich jak zrywanie się łańcucha zgrzebłowego. W artykule przedstawiono wyniki symulacji komputerowych wpływu zerwania łańcucha na obciążenia dynamiczne bębnów łańcuchowych w napędzie głównym i pomocniczym podczas rozruchu i w ruchu ustalonym, w przenośniku ścianowym o długości 350 m.
In high-efficiency chain conveyors installed in long faces the condition of driver and chain systems load is changing in comparison with standard faces. High maximum values and amplitudes of dynamic loads in the conveyor can cause breakdowns, such as the breaking of a conveyor chain. The article presents the results of computer simulations showing the impact of the chain breaking on the dynamic load of chain drums in the major and auxiliary drives during the start-up and the set operation, in a 350-metres long face conveyor.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2010, R. 48, nr 12, 12; 5-11
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A breakdown of sector performance of the visegrad countries and germany in light of structural convergence
Autorzy:
Úradníček, Vladimír
Zimková, Emília
Powiązania:
https://bibliotekanauki.pl/articles/434116.pdf
Data publikacji:
2013
Wydawca:
Wydawnictwo Uniwersytetu Ekonomicznego we Wrocławiu
Tematy:
business cycle synchronization
sector breakdown
Krugman specialization index
Opis:
The aim of this contribution is to analyze a breakdown of sector performance of the Visegrad countries and Germany in light of structural convergence. The macroeconomic view on structural convergence was researched by the estimation of business cycle synchronization of pairs of countries. The microeconomic aspect of structural convergence is characterized by the breakdown of sector performance of the analyzed countries and the application of the Krugman specialization index.
Źródło:
Śląski Przegląd Statystyczny; 2013, 11(17); 31-48
1644-6739
Pojawia się w:
Śląski Przegląd Statystyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Detonation Performance and Characteristics of 2,4,6-Trinitrotoluene Based Melt Cast Explosives Containing Aluminum by Laser Induced Breakdown Spectroscopy
Autorzy:
Rezaei, Amir Hossein
Keshavarz, Mohammad Hossein
Tehrani, Masoud Kavosh
Darbani, Mohammad Reza
Powiązania:
https://bibliotekanauki.pl/articles/358347.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
laser induced breakdown
spectroscopy
molecular structure
chemical analysis
Opis:
Aluminized melt cast formulations based on 2,4,6-trinitrotoluene (TNT) deliver an enhanced blast effect because the secondary combustion process of aluminum (Al) occurs beyond the detonation zone. A new method is introduced to assess the detonation performance and characteristics of aluminized TNT explosives on the basis of the laser-induced breakdown spectroscopy (LIBS) technique, in both air and argon (Ar) atmospheres. The plasma emissions of the prepared samples were recorded, where the atomic lines of Al, C, O and H as well as the molecular bands of AlO, CN and C2 were identified. A good discrimination and separation between the samples was possible using LIBS and principle component analysis (PCA), although they had similar atomic compositions. The quantitative calibration curve obtained using the relative intensity of Al/O was used to determine the detonation velocity/pressure and aluminum content of the TNT/Al samples. Comparisons between experimental and theoretical spectra were made using a Nelder–Mead temperature program for CN bands, which provided good agreement with the fitted spectra. Finally, CN vibrational temperatures were calculated from these spectral fittings. These temperatures have higher values in an Ar atmosphere than in an air atmosphere. Thus, increasing the oxygen concentration can decrease these temperatures in TNT/Al standard samples.
Źródło:
Central European Journal of Energetic Materials; 2019, 16, 1; 3-20
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dispersion of estimates of linear regression parameters in case of the deepest regression method
Zróżnicowanie ocen parametrów regresji liniowej uzyskanych metodą najgłębszej regresji
Autorzy:
Pruska, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/907023.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
the deepest regression method
outliers
dispersion
breakdown value
Opis:
The deepest regression method is such a method of estimation of regression parameters that the maximal regression depth characterises the obtained model. In this paper the deeepest regression method is presented and the simulation analysis (Monte Carlo experiments) of dispersion of linear regression parameter estimates is conducted in case of data sets with different numbers of outliers. On the basis of the results of Monte Carlo experiments the characteristics of distribution of regression parameter estimates are determined and compared with the results of analogous experiments conducted with the use of the least square method.
Metoda najgłębszej regresji polega na oszacowaniu parametrów liniowej funkcji regresji w taki sposób, aby uzyskanemu modelowi odpowiadała największa głębia regresyjna. W pracy przedstawiono charakterystykę metody najgłębszej regresji i przeprowadzono symulacyjną analizę (metodami Monte Carlo) zróżnicowania ocen parametrów modelu regresji liniowej uzyskanych tą metodą dla zbiorów danych zawierających różną liczbę obserwacji nietypowych. Na podstawie przeprowadzonych eksperymentów Monte Carlo wyznaczono charakterystyki rozkładu ocen parametrów i dokonano porównania otrzymanych wyników z wynikami analogicznych eksperymentów, w których do estymacji parametrów wykorzystano metodę najmniejszych kwadratów.
Źródło:
Acta Universitatis Lodziensis. Folia Oeconomica; 2008, 216
0208-6018
2353-7663
Pojawia się w:
Acta Universitatis Lodziensis. Folia Oeconomica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekspertyzy konstrukcyjne przewodów wodociągowych sposobem na eliminację ich awarii
Autorzy:
Kuliczkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/364938.pdf
Data publikacji:
2011
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
awaria
technologie bezwykopowe
wodowciągi
breakdown
sewage
trenchless technology
Opis:
Awarie przewodów wodociągowych są niezwykle uciążliwe zarówno dla odbiorców wody, jak również dla użytkowników terenów, na których mają one miejsce. W trakcie eksploatacji przewodów wodociągowych może wystąpić wiele czynników wpływających na istotną zmianę początkowej wartości współczynnika bezpieczeństwa ich konstrukcji i przyczyniających się do powstania awarii.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2011, 6; 58-61
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca silnikowa generatora synchronicznego podczas awaryjnego połączenia z siecią elektroenergetyczną
The motor work of synchronous generator during single-and double-phase supply from electrical network
Autorzy:
Zakrzewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/159861.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
maszyny synchroniczne
stany awaryjne
synchronous machines
breakdown state
Opis:
W pracy zwrócono uwagę na bieg synchroniczny generatora pracującego jako silnik w warunkach, kiedy wskutek awarii wyłącznika sieciowego jeden lub dwa bieguny pozostają w stanie zamkniętym. Określono wartość momentu maksymalnego, który teoretycznie może być rozwijany przez silnik w wymienionych stanach zasilania od strony sieci elektroenergetycznej. Założono, że strona GN transformatora blokowego jest połączona w gwiazdę z przewodem zerowym, strona DN w trójkąt.
The paper deals with the synchronous run of three – phase generator which works as a motor during single- and double-phase supply from electrical network. The maximal torque of the motor in this states was defined. The generator transformer connection is: HV winding-star with neutral conductor, LV winding-triangle.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 275; 23-29
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przebicie elektryczne izolacyjnej warstwy tlenku aluminium elektrycznych podzespołów pojazdów
Electrical breakdown of aluminium oxide insulating layer electrical sub-assembly vehicles
Autorzy:
Bąk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/198630.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
przebicie elektryczne
warstwa tlenkowa
electrical breakdown
oxide layer
Opis:
W artykule przedstawiono podstawowe zastosowania elektrolitycznych warstw tlenkowych jako izolatora uzwojeń elektromagnesów i transformatorów oraz uzwojeń elektrycznych siłowników służących do sterowania zaworów silników spalinowych pojazdów samochodowych. Opisano wyniki badań mechanizmu przebicia elektrycznego anodowych powłok tlenkowych wytworzonych na taśmach aluminiowych (Al99,5), przeznaczonych na uzwojenia elektrycznych urządzeń sterujących w pojazdach. W artykule opisano wyniki badań zjawisk zachodzących w powłoce tlenkowej oraz w warstwie powierzchniowej utlenionej taśmy aluminiowej (Al99,5), w miejscu przebicia elektrycznego. Do przebicia elektrycznego wykorzystano elektrodę stożkową, pozwalającą ściśle określić miejsce zniszczenia powłoki wskutek przepływu prądu elektrycznego. Podczas badań wykonano pomiary i rejestrację krzywych przebiegu napięcia i prądu przebicia w celu określenia energii zużytej na uszkodzenie warstwy tlenkowej. Ilość energii elektrycznej zużytej podczas przebicia jest wystarczająca do stopienia zarówno warstwy tlenkowej, jak i mikroobjętości aluminium pod warstwą.
The thesis presents the basic applications of electrolytic oxide layers as insulator of electric winding of electromagnet and transformers and electric winding of cylinders used for steering the valve of combustion engines. The results of research describe the mechanism of avalanche breakdown of oxide layers anode produced on aluminum strip (Al99,5), designed for electric winding which steer the vehicle equipment and valve of combustion engines. The phenomena occurring in the oxide layer and surface layer of oxidized aluminum strip (Al99,5) where the avalanche breakdown occurred are described. Conical electrode was used to define precisely the place of layer destruction due to electric current flow. During the research measurements and registration of voltage and current curve were made to define the energy used to destroy the oxide layer. The amount of energy used during the avalanche breakdown is enough to melt both the oxide layer and micro volume of aluminum under the layer.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2012, 77; 5-12
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of microparticles in initiating the electric breakdown in high–voltage vacuum insulation systems
Autorzy:
Opydo, W.
Opydo, D.
Bieliński, W.
Powiązania:
https://bibliotekanauki.pl/articles/97674.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high–voltage vacuum insulation systems
metallic microparticles
electric breakdown
Opis:
The paper presents the hypotheses of initiating mechanisms of the electric breakdown in vacuum insulation systems caused by small material granules, i.e. the microparticles. The microparticles detached from the parent electrode have an electric charge and move in the inter–electrode area due to the electric field. The role of a microparticle in initiating the breakdown in a vacuum insulation system depends to a considerable extent on the microparticle energy at the moment of its impact against the opposite electrode, i.e. on its velocity at the impact time. The paper presents calculation of the microparticle velocity values at the moment of the impact against the opposite electrode under the conditions existing in practice in the vacuum insulation systems. It was assumed for purposes of the calculation that the microparticles are spherical and made of copper, aluminum or iron, and are subjected to constant electric field. Minimum values of the microparticle velocity necessary to cause plastic deformation of the electrode surface in result of the impact are determined. (The calculations have been carried out with the computer program developed in C# language on the Visual Studio 2013 environment.)
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 177-186
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Breakdown cause and effect analysis. Case study
Autorzy:
Biały, W.
Ružbarský, J.
Powiązania:
https://bibliotekanauki.pl/articles/409633.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
analysis
production process
breakdown
FMEA
Ishikawa diagram
Pareto chart
Opis:
Every company must ensure that the production process proceeds without interferences. Within this article, the author uses the term “interferences” in reference to unplanned stoppages caused by breakdowns. Unfortunately, usually due to machine operators’ mistakes, machines break, which causes stoppages thus generating additional costs for the company. This article shows a cause and effect analysis of a breakdown in a production process. The FMEA as well as quality management tools: the Ishikawa diagram and Pareto chart were used for the analysis. Correction measures were presented which allowed for a significant reduction in the number of stoppages caused by breakdowns.
Źródło:
Management Systems in Production Engineering; 2018, 2 (26); 83-87
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownie jądrowe w warunkach awarii katastrofalnej
Autorzy:
Grządzielski, I.
Sroka, K.
Powiązania:
https://bibliotekanauki.pl/articles/397401.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
elektrownie jądrowe
awaria
katastrofa
nuclear power plants
breakdown
disaster
Opis:
W artykule podjęto próbę wstępnej oceny pracy elektrowni jądrowych w warunkach awarii katastrofalnej. Analizę tę przeprowadzono, wykorzystując doświadczenia z przebytych awarii katastrofalnych w krajach ze znaczącą generacją z elektrowni jądrowych. Na bazie tych doświadczeń podjęto próbę zdefiniowania charakterystycznych cech elektrowni jądrowych i sformułowania wymagań, jakie muszą spełniać te elektrownie w systemie elektroenergetycznym w kontekście możliwości wystąpienia blackoutu.
Źródło:
Acta Energetica; 2011, 1; 5-10
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formulaic Sequences as Fluency Devices in the Oral Production of Native Speakers of Polish
Autorzy:
Guz, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/620584.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
formulaic sequences
speed fluency
breakdown fluency
temporal speech measures
Opis:
In this paper we attempt to determine the nature and strength of the relationship between the use of formulaic sequences and productive fluency of native speakers of Polish. In particular, we seek to validate the claim that speech characterized by a higher incidence of formulaic sequences is produced more rapidly and with fewer hesitation phenomena. The analysis is based on monologic speeches delivered by 45 speakers of L1 Polish. The data include both the recordings and their transcriptions annotated for a number of objective fluency measures. In the first part of the study the total of formulaic sequences is established for each sample. This is followed by determining a set of temporal measures of the speakers’ output (speech rate, articulation rate, mean length of runs, mean length of pauses, phonation time ratio). The study provides some preliminary evidence of the fluency-enhancing role of formulaic language. Our results show that the use of formulaic sequences is positively and significantly correlated with speech rate, mean length of runs and phonation time ratio. This suggests that a higher concentration of formulaic material in output is associated with faster speed of speech, longer stretches of speech between pauses and an increased amount of time filled with speech.
Źródło:
Research in Language; 2014, 12, 2; 113-129
1731-7533
Pojawia się w:
Research in Language
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of selected parameters on the electrical strength of a high-voltage vacuum insulation system
Autorzy:
Lech, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/27309926.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
electrical breakdown
electrical contacts
electrical strength
switchgear
vacuum insulation
Opis:
The article presents the results of laboratory measurements of breakdown voltages in a high-voltage vacuum insulating system for different pressures, contact gaps, type of electrode contacts and type of residual gas inside the discharge chamber. First of all, the electrical strength of the discharge chamber with a contact system terminated with contact pads made of W70Cu30 and Cu75Cr25 material was compared for selected values of contact gaps. It was found that below a pressure of = 3.0×10−1 Pa the electrical strength reaches an approximately constant value for each of the set contact gaps . Analytical relationships were determined to calculate this value for each of the contact pads used. Above a pressure of = 3.0 × 10−1 Pa, the measured values of breakdown voltages decrease sharply. The values of breakdown voltages in the discharge chamber with residual gases in the form of air, argon, neon and helium were also determined for selected values of contact gaps . Depending on the residual gases used, significant differences were noted in the values of pressure at which the loss of insulating properties in the discharge chamber occurred. These values were 3.3 × 10−1 Pa for argon, 4.1 × 10−1 Pa for air, 6.4 × 10−1 Pa for neon, and 2.55 × 100 Pa for helium, respectively.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 597--611
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability analysis of N-policy vacation-based FTC system subject to standby switching failures
Autorzy:
Kumar, Sudeep
Gupta, Ritu
Powiązania:
https://bibliotekanauki.pl/articles/27315336.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reliability
standby switching failure
N-policy
server breakdown
optional service
Opis:
The paper is aimed to investigate the reliability metrics of a multi-unit fault-tolerant control (FTC) system wherein the units are subject to failure and those are repairable by two heterogeneous servers. Server 1 remains permanently available for essential service of failed units, whereas server 2 goes on vacation and renders service based on the N-policy threshold, which may also provide optional and essential services. Server 1 may break down at a steady rate during its servicing period but immediately gets repaired and resume servicing the failed units. When the working unit fails, the available warm standby unit holds responsibility for the smooth operation of the system. The transition of standby units to operational mode may be unsuccessful with switching failure probability. We develop a Markovian model to obtain the steady-state probabilities. We explore computational and sensitivity analysis of different performance measures for various variability of the parameters.
Źródło:
Operations Research and Decisions; 2023, 33, 2; 53--80
2081-8858
2391-6060
Pojawia się w:
Operations Research and Decisions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki badań uszkodzeń awaryjnych wybranej grupy ciągników rolniczych
Analysis of mechanisation services in ecological farms
Autorzy:
Rybacki, P.
Durczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/290932.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
uszkodzenie awaryjne
demontaż
maszyna rolnicza
breakdown damage
disassembly
farm machine
Opis:
Uszkodzenia awaryjne są szczególnie groźne w maszynach rolniczych, pracujących w bardzo niestabilnych i trudnych warunkach atmosferycznych i glebowych. Mogą mieć one różną postać i przyczyny je wywołujące. Celem pracy jest przeprowadzenie badań uszkodzeń awaryjnych nowoczesnych ciągników rolniczych, w aspekcie wad konstrukcyjnych i montażowych zespołów i części oraz prawidłowego użytkowania.
Breakdown damage is particularly dangerous in farm machines, working in highly unstable and difficult weather and soil conditions. This damage may have various forms and may be induced by different reasons. The purpose of this work is to carry out the research on breakdown damage cases in modern farm tractors, in the aspects of constructional and assembly defects in units and parts, and correct operation.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 5, 5; 247-252
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies