Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tissue analysis" wg kryterium: Temat


Tytuł:
Phalaenopsis cultivation in different media. Part II. Nutrients and chlorophyll concentration in leaves and roots
Uprawa Phalaenopsis w różnych podłożach. Część II. Zawartość składników pokarmowych oraz chlorofilu w liściach i korzeniach
Autorzy:
Trelka, T.
Breś, W.
Jóźwiak, A.
Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/11541938.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
Phalaenopsis
plant cultivation
medium
leaf
root
nutrient concentration
chlorophyll concentration
orchid
tissue analysis
macroelement
microelement
pot plant
Opis:
Effect of growing media on macro- and microelements, as well as on chlorophyll concentration in Phalaenopsis orchids were investigated. In the years 2006–2008, an experiment on Phalaenopsis orchids cultivation was carried out. The plants were planted into New Zealand sphagnum moss, mixture of expanded clay pellets and New Zealand sphagnum moss (v:v = 1:1), or into expanded clay pellets only. Orchids were grown in translucent plastic pots. Total macro and micro elements concentration in leaves and roots were determined. Furthermore concentrations of chlorophyll a and chlorophyll b in leaves and roots were measured. Growing media exert a significant influence on the nutritional status of Phalaenopsis orchids. The highest concentration of magnesium, iron and copper was found in plants grown in expanded clay, less in orchids grown in the mixed medium and the least in plants grown in sphagnum moss. A higher concentration of nitrogen, phosphorus, potassium, calcium and manganese was found in leaves. Inversely, in roots, there was a higher concentration of magnesium, iron and zinc. Growing media did not affect chlorophyll concentration in leaves and roots of Phalaenopsis.
Do badań dotyczących wpływu podłoży na zawartość składników pokarmowych oraz chlorofilu w liściach i korzeniach storczyka Phalaenopsis wybrano odmiany ‘Springfield’ i ‘Zagreb’. W roku 2006 rośliny sadzono do następujących podłoży: mech torfowiec (New Zealand sphagnum moss), mieszanka mchu torfowca z keramzytem (v:v = 1:1) oraz w keramzyt o granulacji 8–16 mm. Początkowo (8,5 miesiąca) storczyki rosły w doniczkach o średnicy 7 cm, następnie w przeźroczystych pojemnikach o średnicy 11 cm i pojemności 0,5 dm3. Raz na dwa tygodnie rośliny dokarmiano pożywką o składzie: N-NH4 – 100; N-NO3 – 120; P – 40, K – 230; Ca – 30; Mg – 20; Na – 10; Cl – 20; S-SO4 – 40; Fe – 0,8; Mn – 0,4; Zn – 0,2; Cu – 0,07; B – 0,2 mg·dm-3; pH 6,6; EC – 1,8 mS·cm-1. W roku 2008 (stadium kwitnienia) w liściach i korzeniach oznaczono całkowite zawartości makro- i mikroelementów oraz chlorofilu a i b. Podłoża wpływały na stan odżywienia roślin – najwyższą zawartość magnezu, żelaza, miedzi stwierdzono w organach roślin uprawianych w keramzycie, najmniejszą w storczykach uprawianych w mchu torfowcu. Jednocześnie zawartość cynku i manganu była najwyższa w roślinach uprawianych w mchu torfowcu. W liściach stwierdzono wyższą zawartość azotu, fosforu, potasu, wapnia i manganu, natomiast w korzeniach magnezu i żelaza i cynku. Ponadto liście zawierały więcej chlorofilu-a i chlorofilu-b w porównaniu z korzeniami.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2010, 09, 3; 95-104
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Empirical Mode Decomposition of Backscattered Ultrasound Signal Power Spectrum for Assessment of Tissue Compression
Autorzy:
Byra, M.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177950.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tissue characterization
tissue compression
quantitative ultrasound
empirical mode decomposition
signal analysis
Opis:
Quantitative ultrasound has been widely used for tissue characterization. In this paper we propose a new approach for tissue compression assessment. The proposed method employs the relation between the tissue scatterers’ local spatial distribution and the resulting frequency power spectrum of the backscattered ultrasonic signal. We show that due to spatial distribution of the scatterers, the power spectrum exhibits characteristic variations. These variations can be extracted using the empirical mode decomposition and analyzed. Validation of our approach is performed by simulations and in-vitro experiments using a tissue sample under compression. The scatterers in the compressed tissue sample approach each other and consequently, the power spectrum of the backscattered signal is modified. We present how to assess this phenomenon with our method. The proposed in this paper approach is general and may provide useful information on tissue scattering properties.
Źródło:
Archives of Acoustics; 2018, 43, 3; 447-453
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Digital analysis and potato tissue image processing at the application of Voronois diagrams
Autorzy:
Pukos, A.
Pezda, M.
Guc, A.
Powiązania:
https://bibliotekanauki.pl/articles/25331.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil structure
potato tissue
Voronoi's diagram
plant tissue
cell wall
geometrical property
image analysis
Źródło:
International Agrophysics; 1995, 09, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity analysis of transient bioheat transfer during thermal injury formation of biological tissue
Autorzy:
Jasiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/122465.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
bioheat transfer
tissue injury integral
tissue injury
sensitivity analysis
przepływ ciepła
uraz tkanki
analiza wrażliwości
Opis:
The sensitivity analysis of the transient temperature field in the 2D tissue domain with respect to its thermophysical parameters is discussed. In particular, the influence of tissue specific heat, thermal conductivity, perfusion rate and metabolic heat source on the temperature distribution is considered. In order to determine the influence of variations of these parameters on temperature distribution, the direct approach of sensitivity analysis is applied. The algorithm of modeling of tissue injury withdrawal based on Arrhenius integral is also presented. At the stage of numerical realization the boundary element method is used. In the final part of paper the results obtained are shown.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2014, 13, 2; 33-42
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cell orientation in potato tuber parenchyma tissue
Autorzy:
Gancarz, M.
Konstankiewicz, K.
Zgorska, K.
Powiązania:
https://bibliotekanauki.pl/articles/25689.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
microstructure
cell parameter
potato tuber
parenchyma tissue
image analysis
Opis:
The paper presents the results of the research of the size and shape of parenchyma tissue cells in potato tubers depending on the direction and site of sampling in tubers. An optical confocal microscope was used to observe samples in their natural state. The investigation was carried out for 1 mm thick samples cut from cylindrical samples (10x10 mm)taken in two mutually perpendicular directions of the inner and outer core of each variety. The analysis was done ten times.The methods developed for the composition and image analysis ensure obtaining a sufficient number of cells to determine tissue structure parameters (surface, shape, elongation and number of cells per 1 mm2) and decays of these parameters were obtained. Statistical analysis was performed using the -Kolmogorov-Smirnov compliance test.Arelationship between the direction of sampling and the size and shape of the inner core of cells was found. Greater surface area and elongation of the inner core cells for the longitudinal direction in the tuber (stolon – top) was demonstrated. There was no such a correlation for the outer core in the tubers of the cultivars examined.
Źródło:
International Agrophysics; 2014, 28, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cell structural parameter of potato tuber tissue
Autorzy:
Konstankiewicz, K.
Czachor, H.
Gancarz, M.
Krol, A.
Pawlak, K.
Zdunek, A.
Powiązania:
https://bibliotekanauki.pl/articles/24511.pdf
Data publikacji:
2002
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
physical property
cell structure
potato
tissue
image analysis
tuber
Źródło:
International Agrophysics; 2002, 16, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microarray Inspector: tissue cross contamination detection tool for microarray data
Autorzy:
Stępniak, Piotr
Maycock, Matthew
Wojdan, Konrad
Markowska, Monika
Perun, Serhiy
Srivastava, Aashish
Wyrwicz, Lucjan
Świrski, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1039460.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
microarray
transcription profiling
contamination analysis
adipose tissue
cancer
data quality
Opis:
Microarray technology changed the landscape of contemporary life sciences by providing vast amounts of expression data. Researchers are building up repositories of experiment results with various conditions and samples which serve the scientific community as a precious resource. Ensuring that the sample is of high quality is of utmost importance to this effort. The task is complicated by the fact that in many cases datasets lack information concerning pre-experimental quality assessment. Transcription profiling of tissue samples may be invalidated by an error caused by heterogeneity of the material. The risk of tissue cross contamination is especially high in oncological studies, where it is often difficult to extract the sample. Therefore, there is a need of developing a method detecting tissue contamination in a post-experimental phase. We propose Microarray Inspector: customizable, user-friendly software that enables easy detection of samples containing mixed tissue types. The advantage of the tool is that it uses raw expression data files and analyses each array independently. In addition, the system allows the user to adjust the criteria of the analysis to conform to individual needs and research requirements. The final output of the program contains comfortable to read reports about tissue contamination assessment with detailed information about the test parameters and results. Microarray Inspector provides a list of contaminant biomarkers needed in the analysis of adipose tissue contamination. Using real data (datasets from public repositories) and our tool, we confirmed high specificity of the software in detecting contamination. The results indicated the presence of adipose tissue admixture in a range from approximately 4% to 13% in several tested surgical samples.
Źródło:
Acta Biochimica Polonica; 2013, 60, 4; 647-655
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of plant tissue images obtained by confocal tandem scanning reflected light microscope
Autorzy:
Gancarz, M.
Konstankiewicz, K.
Pawlak, K.
Zdunek, A.
Powiązania:
https://bibliotekanauki.pl/articles/25430.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
plant cell
confocal microscopy
plant tissue
structural parameter
image analysis
Źródło:
International Agrophysics; 2007, 21, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New image analysis method for the estimation of global and spatial changes in fruit microstructure
Autorzy:
Pieczywek, P.M.
Cybulska, J.
Dyki, B.
Konopacka, D.
Mieszczakowska-Frac, M.
Zdunek, A.
Powiązania:
https://bibliotekanauki.pl/articles/24601.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
image analysis
global change
spatial change
fruit
apple
plant tissue
microstructure
Źródło:
International Agrophysics; 2016, 30, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantitative method for determining cell structural parameters of plant tissues
Autorzy:
Konstankiewicz, K.
Pawlak, K.
Zdunek, A.
Powiązania:
https://bibliotekanauki.pl/articles/24956.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
quantitative method
plant tissue
cell structure
potato
parenchyma
tuber
image analysis
Źródło:
International Agrophysics; 2001, 15, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the optode array representation using optical properties at systole and diastole
Autorzy:
Jumadi, N A
Beng, G K
Mohd-Ali, M. A.
Zahedi, E
Powiązania:
https://bibliotekanauki.pl/articles/173805.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical simulation
optical properties
optode array
semi-infinite tissue layer
statistical
analysis
Opis:
The necessity to develop an optode array in order to probe the fetus oxygenation noninvasively regardless of the fetus position has been highlighted in previous literature. In this paper, a series of optical simulations are carried out to determine the best representation of optode array by using optical properties at systolic and diastolic states. The selection is based on the highest flux values accumulated at respective detectors. To accomplish the objective, a homogenous three-layer semi-infinite tissue model is implemented to represent the pregnant woman model. The geometry of the model as well as Monte Carlo simulation are carried out using commercial software, whereas the optical properties related to systolic and diastolic states are defined for all wavelengths. A statistical noise analysis is also introduced in order to find a sufficient number of rays to be launched into the optical tissue system.
Źródło:
Optica Applicata; 2013, 43, 4; 747-759
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
BoneCreo: a novel approach for generating a geometric model of the bone structure
Autorzy:
Wrona, A.
Powiązania:
https://bibliotekanauki.pl/articles/306211.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
model numeryczny
kości
symulacja komputerowa
numerical model
bone tissue
image analysis
computer simulation
Opis:
Bones, the fundamental part of the skeleton, are constantly subjected to many biological processes including growth, feeding and remodelling. Remodelling causes changes in bone structure that may be difficult to notice on a day-to-day basis but become significant over the longer time span. It acts on the cancellous and cortical bone tissue, causing alterations in thickness and spatial arrangement in the first and alternations in pore size in the second. In healthy individuals such changes are a part of the natural bone remodelling process explained by Wolff’s law. However, the direction of such changes is difficult to predict in patients in various pathological states in which bone health is affected. Here, we present a method to generate a computer based geometric model of the bone structure based on the cancellous tissue structure images. As a result we obtained a geometric model of the structure corresponding to the physical model of the cancellous bone. Such a model can be used in computer simulation to predict the remodelling changes in the healthy and pathological bone structures.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 3; 3-12
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A numerical study on indentation properties of cortical bone tissue : Influence of anisotropy
Autorzy:
Demiral, M.
Abdel-Wahab, A.
Silberschmidt, V.
Powiązania:
https://bibliotekanauki.pl/articles/306784.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza MES
anizotropia
metoda Olivera i Pharra
identacja
finite element analysis
anisotropy
Oliver–Pharr method
cortical bone tissue
indentation
Opis:
Purpose: The purpose of this study is to investigate the effect of anisotropy of cortical bone tissue on measurement of properties such as direction-dependent moduli and hardness. Methods: An advanced three-dimensional finite element model of microindentation was developed. Different modelling schemes were considered to account for anisotropy of elastic or/and plastic regimes. The elastic anisotropic behaviour was modelled employing an elasticity tensor, and Hill’s criteria were used to represent the direction-dependent post-yield behaviour. The Oliver–Pharr method was used in the data analysis. Results: A decrease in the value of the transverse elasticity modulus resulted in the increased material’s indentation modulus measured in the longitudinal direction and a decreased one in the transverse direction, while they were insensitive to the anisotropy in post-elastic regime. On the other hand, an increase in plastic anisotropy led to a decrease in measured hardness for both directions, but by a larger amount in the transverse one. The size effect phenomenon was found to be also sensitive to anisotropy. Conclusions: The undertaken analysis suggests that the Oliver–Pharr method is a useful tool for first-order approximations in the analysis of mechanical properties of anisotropic materials similar to cortical bone, but not necessarily for the materials with low hardening reserves in the plastic regime.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 2; 3-14
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Confocal microscopy for investigations of agricultural materials
Autorzy:
Konstankiewicz, K.
Krol, A.
Pukos, A.
Powiązania:
https://bibliotekanauki.pl/articles/25302.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
microstructure
potato tissue
image transmission
computer image analysis
tandem scanning reflected light microscope
agricultural material
confocal microscopy
tomograph image
Źródło:
International Agrophysics; 1995, 09, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the influence of elevated temperature on oxygen distribution in soft tissue
Autorzy:
Jasiński, Marek
Zadoń, Maria
Powiązania:
https://bibliotekanauki.pl/articles/38910037.pdf
Data publikacji:
2023
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
bioheat transfer
tissue thermal damage
oxygen transport
Krogh cylinder
oxyhemoglobin dissociation curve
finite difference method
shooting method
sensitivity analysis
Opis:
The purpose of the study was to analyze the combined model of bioheat transfer and oxygen distribution in tissue during exposition to the external heat impulse. The effect of temperature and thermal damage to the tissue on the values of its thermophysical parameters was taken into account. The variable value of the perfusion coefficient affects the blood velocity in the capillary and thus the distribution of the partial oxygen pressure in the tissue. Various models of the oxygen dissociation curves were also considered and a sensitivity analysis was performed for the parameters of the oxygen distribution model. In the numerical realization stage, the finite difference method and the shooting method were used.
Źródło:
Engineering Transactions; 2023, 71, 3; 287-306
0867-888X
Pojawia się w:
Engineering Transactions
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies