Wyszukujesz frazę "thermal screen" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Comparison of heat requirements in greenhouses for Kirşehir and Kahramanmaraş provinces
Autorzy:
Boyaci, Sedat
Akyüz, Adil
Tanriverdi, Çağatay
Powiązania:
https://bibliotekanauki.pl/articles/2131639.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
greenhouse
heat requirement
thermal screen
energy saving
Opis:
Greenhouses are artificial growing environments that can provide the growth factors required for the production of crop plants out of season. In these structures, the low temperature values that occur during the year cause losses in yield and quality because they are not suitable for plant cultivation. In order to be able to grow out of season in these periods, the amount of heat required by the plants should be provided with additional heating. In the study carried out to determine the amount of heat needed in greenhouses throughout the year for the provinces of Kırşehir and Kahramanmaraş, which are located in two different regions of Turkey, the heat requirements that will arise in the presence or absence of a thermal screen in greenhouses with the same characteristics were calculated. In the calculations, the most common tomato plant grown in both provinces has been considered. Accordingly, if the greenhouse temperature is kept at a constant temperature of 18°C throughout the year, the heat energy requirements that emerge during the year are 469.90 kWh m.-2 for Kırşehir and 254.71 kWh m.-2 for Kahramanmaraş. In the case of using a thermal screen, these values were calculated as 401.53 kWh m.-2 for Kırşehir province and 218.91 kWh m.-2 for Kahramanmaraş province. As a result of the study, the amount of heat energy needed in greenhouses in provinces decreased with the use of thermal screens. It has been determined that this situation is extremely important in terms of reducing the share of heating in production costs and the amount of carbon dioxide released into the atmosphere by fossil energy sources used for heating purposes.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2022, nr I/1; 5-20
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rzeczywista charakterystyka energetyczna budynku szklarni
Greenhouse actual energy performance
Autorzy:
Grabarczyk, S.
Powiązania:
https://bibliotekanauki.pl/articles/362368.pdf
Data publikacji:
2016
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
szklarnia
ekran termoizolacyjny
charakterystyka energetyczna
greenhouse
thermal screen
energy performance
Opis:
W artykule przedstawiono wyniki badań wykonanych w całorocznie eksploatowanej szklarni, których celem była analiza efektywności energetycznej oraz w rezultacie ustalenie zapotrzebowania na nieodnawialną energię pierwotną i wielkości emisji dwutlenku węgla do atmosfery. Badania przeprowadzono w szklarni z ekranem termoizolacyjnym, który w okresie nocnym w znaczący sposób ogranicza straty ciepła. W badaniach określono ilość energii użytecznej, końcowej i pierwotnej jaką zużywa typowy obiekt szklarniowy eksploatowany całorocznie w Polsce centralnej. W efekcie końcowym ustalono z jak dużą emisją dwutlenku węgla mamy do czynienia, gdy paliwem jest miał węglowy.
This paper presents results of research conducted in an all-year-round operated greenhouse. It aimed at analyzing its energy efficiency and, as a consequence, calculating its demand for non-renewable primary energy as well as the amount of the emission of carbon dioxide. The greenhouse had a thermal screen installed in order to reasonably reduce the loss of heat at night. As a result, it has been determined how much of the useful energy, final energy and primary energy is consumed yearly by a typical greenhouse, placed in central Poland. It has also been found out how much carbon dioxide is likely to be emitted to the atmosphere providing that fine coal is the fuel.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2016, T. 8, nr 4, 4; 15-22
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność wentylacji naturalnej w szklarni
Effectiveness of natural ventilation in a greenhouse
Autorzy:
Grabarczyk, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1848330.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
szklarnia
wentylacja naturalna
ekran termoizolacyjny
greenhouse
natural ventilation
thermal screen
Opis:
W szklarniach w celu utrzymania właściwej temperatury wewnętrznej, w okresie występowania dużych wartości natężenia promieniowania słonecznego, stosuje się zabiegi cieniowania z użyciem ekranów termoizolacyjnych oraz wietrzenia. Badania przeprowadzono w szklarni jednonawowej w celu określenia skuteczności wentylacji naturalnej. Przedmiotem analiz jest szklarnia z zainstalowanym wewnątrz ekranem termoizolacyjnym. Badania przeprowadzono podczas dni letnich. Efektem analiz było określenie na podstawie pomiarów i analiz obliczeniowych strumienia powietrza wentylacyjnego przepływającego przez wietrzniki dachowe szklarni. Ustalono zależności strumienia powietrznego po stronie nawietrznej oraz zawietrznej od prędkości wiatru, a także różnicy temperatur wewnątrz i na zewnątrz szklarni. Na podstawie obliczeń wykonanych dla obserwacji podczas cieniowania powierzchni uprawnej oraz przy otwartych wietrznikach określono współczynniki wymiany powietrza na powierzchnię jednostkową szklarni. Ustalono, że przy prędkości wiatru przekraczającej 0,8 m/s współczynnik wymiany powietrza w badanej szklarni przekracza wartość zalecaną przez ASAE wynoszącą 0,04 m3/(sxm2).
In greenhouses, in order to maintain proper indoor air temperature, during the period of high values of solar radiation intensity, shading treatments using thermal screens and ventilation are applied. The research was carried out in a mono-span greenhouse in order to determine the effectiveness of natural ventilation. The object of analysis is a greenhouse with a thermal screen installed inside. The tests were carried out during the summer days. The effect of the research was to determine the ventilation air flow through the vents of the greenhouse on the basis of measurements and calculation analyzes. The dependence of the air flow on the windward and leeward side was determined from the wind speed and the temperature difference between the indoor and outdoor air. On the basis of calculations made from observation during shading of the cultivated area and with open ventilators, the coefficients of air exchange per unit floor area of the greenhouse were determined. It was established that at a wind speed exceeding 0.8 m/s, the air exchange rate in the tested greenhouse exceeds the value recommended by the American Society of Agricultural Engineers of 0,04 m3/(sxm2).
Źródło:
Builder; 2021, 25, 5; 64-67
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of plastic tunnel equipment on its thermal balance components
Autorzy:
Kurpaska, S.
Powiązania:
https://bibliotekanauki.pl/articles/298188.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
plastic tunnel
thermal screen
thermal transmittance coefficient
convert rate of solar radiation
Opis:
The paper presents results of research conducted in a standard plastic tunnel equipped with thermal screens measuring 144 m2 . During the experiment the thermal screens in the tunnel were either in a folded or unfolded position (both during the radiation weather and at night), whereas vents were closed. Parameters of the ambient climate (the temperature, wind velocity, air humidity and solar radiation intensity) were measured during the experiment, as well as the parameters of the microclimate inside the objects (the temperature and air humidity).Thermal balance including: the change of heat accumulated inside the object, heat gains from the substratum (through radiation and penetration), heat gains from solar radiation and the heat flux loss were formulated for the discussed cases. In result of the analysis the differences of internal temperature were stated for the object with and without thermal screens. It was found that for the identical values of the ambient climate parameters the temperature inside the object without the thermal screen was c.a. 4.0% higher than in the object equipped with the thermal screen. The thermal transmittance value through the object casing was determined and the convert rate of solar radiation to heat causing increase in the internal temperature in the objects both with and without thermal screens.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2016, 19(4); 313-324
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych czynników na intensywność wymiany ciepła w ogrzewanym tunelu foliowym
Effect of selected factors on heat exchange intensity in the heated foil tunnel
Autorzy:
Kurpaska, S.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/289569.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
ekran cieplny
ekran zagrzejnikowy
strumień ciepła
współczynnik wymiany ciepła
foil tunnel
heat screen
thermal screen
heat flux
heat transfer coefficient
Opis:
W pracy zbadano wpływ wyposażenia ogrzewanego tunelu foliowego oraz różnicy temperatury między czynnikiem grzejnym a powietrzem wewnątrz obiektu na intensywność wymiany ciepła. Do analizy wykorzystano dane monitorowane przez system pomiarowy z tunelu zlokalizowanego na Akademii Rolniczej w Krakowie. Uzyskane wyniki badań pozwoliły określić wpływ wyposażenia dodatkowego na intensywność wymiany ciepła, a w konsekwencji na wymaganą powierzchnię grzewczą systemu grzejnego.
The work includes a study of the effect of the outfit of the heated foil tunnel and difference in temperature between heating medium and air inside the object on heat exchange intensity. For the analysis the data monitored by the measuring system in the tunnel located at the Academy of Agriculture in Krakow was used. The results obtained from the analysis allowed to determine the effect of additional equipment on heat exchange intensity, and in consequence on the required heating area of the heating system.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 11(86), 11(86); 261-268
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Screen Printed Layers on the Thermal Conductivity of Textile Fabrics
Wpływ warstw naniesionych metodą sitodruku na przewodność cieplną tkanin tekstylnych
Autorzy:
Kazani, I.
de Mey, G.
Hertleer, C.
Van Langenhove, L.
Guxho, G.
Powiązania:
https://bibliotekanauki.pl/articles/233169.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
screen printing
thermal conductivity
textile
thermographic camera
sitodruk
przewodność cieplna
tkanina
kamera termograficzna
Opis:
In the smart textile field the combination of textile and metallic materials is rising. In order to conduct electricity in textile, different methods are used. This paper deals with a new measuring method to determine the lateral thermal conductivity of a textile fabric. The technique starts by measuring the temperature distribution on the fabric using a thermographic camera. In addition to that, the method outlined in this paper will also allow to determine the change in thermal conductivity when an electric conducting layer has been screen printed on a textile fabric.
W dziedzinie inteligentnych tkanin wzrasta znaczenie połączeń materiałów tekstylnych i metalicznych. W celu przewodzenia energii elektrycznej w tkaninie stosuje się różne metody. W pracy zaprezentowano nową metodę pomiaru w celu określenia bocznej przewodności cieplnej tkaniny tekstylnej. Technika ta oparta jest na pomiarze rozkładu temperatury na tkaninie za pomocą kamery termograficznej. Oprócz tego, metoda opisana w pracy pozwala również na określenie zmiany przewodności cieplnej, gdy warstwa przewodząca prąd elektryczny zostanie wydrukowana na tkaninie.
Źródło:
Fibres & Textiles in Eastern Europe; 2018, 5 (131); 70-74
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies