Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wodociągowa" wg kryterium: Temat


Tytuł:
System zaopatrzenia Wrocławia w wodę : stan obecny i perspektywy rozwoju
Water-spply system for the municipality of Wrocław : present condition and Developmental prospects
Autorzy:
Zięba, L.
Powiązania:
https://bibliotekanauki.pl/articles/237249.pdf
Data publikacji:
1998
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
sieć wodociągowa
sieć wodociągowa Wrocławia
jakość wody
badania jakości wody
Opis:
Presented is a joint approach to te problem of drinking and household water supply of the city of Wrocław ( with a population of about 760,000 ).The condition ot the entrie supply system is analyzed,particular consideration beig given to the waterpipenetwork and its influence on the guality of the water recived by the user.Water quality (both in the intakes operated by the waterworks and in the pipeline) is monitored continuosly. The flood of July 1997 raised serious problems to the management of the water supply system. The experience gained in those days made it possible to develop reliable measures which would work under critical conditions.Since approximately half of the water volume supplied to the users comes from infilitration intakes wich are fed by surface water,the aquiferous area in general, and the potential points of pollution discharge in particular,were subject to thorough analysis.Based on the analysis not only of the present condition,but of the developmental prospects as well, a critical account of alternative water sources is given and other methods of potable water recovery are considered with the aim to upgrade the quality of the water supplied.
Źródło:
Ochrona Środowiska; 1998, 3; 3-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości usunięcia substancji ropopochodnych z sieci i instalacji wodociągowych
Removal of crude oil spills from a rural water supply system
Autorzy:
Błażejewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/237562.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
sieć wodociągowa
instalacja wodociągowa
usuwanie zanieczyszczeń
substancje ropopochodne
osady żelaziste
roztwór myjący
Opis:
A rural water supply system was contaminated with crude oil along a length of several kilometres. The tap water had a disagreeable odour and carried oil spills on its surf ace. Prewashing with water was found to be insufficient. Analysis of pipe samples showed that crude oil had occluded on the iron-containing incrustation. On the basis of laboratory tests, a procedure was established for the removal of the oil-contaminated incrustation layer. The procedure involved a solution which was made up of NaHSO4, TPF and Roksol MS (a mixed nonionic and anionic surfactant). The pipeline was washed stepwise. The said solution was passed to particular pipe sections, and mixing was provided via air supply. After 24 hours of treatment, the pipe section was rinsed, and the effluent was collected in tanks before it was sent to the wastewater treatment plant. The rinsing procedure was discontinued after the concentration of anionic and nonionic surfactans decreased to the value of 0.1 g/m[3] and 0.2 g/m[3], respectively, and the tap water was free of benzene and of the typical crude oil odour.
Źródło:
Ochrona Środowiska; 2001, 4; 47-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty modelowania systemu zaopatrzenia w wodę na przykładzie miasta Łapy
Selected aspects of modelling in water supply system on the example of Łapy city
Autorzy:
Kruszyński, W.
Dzienis, L.
Powiązania:
https://bibliotekanauki.pl/articles/1825966.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zaopatrzenie w wodę
sieć wodociągowa
Opis:
Celem pracy jest modelowanie wybranych parametrów sieci wodociągowej miasta Łapy oraz symulacja zamiaru podłączenia nowych ujęć dla różnych wariantów lokalizacyjnych. Jako obiekt badań wybrano sieć wodociągową miasta Łapy o liczbie mieszkańców 2300, zasilaną z trzech ujęć. Średnie dobowe zużycie wody wynosi 1383 m3/d. Większość wody zużywana jest przez mieszkalnictwo oraz tereny przemysłowo-składowe.
The aim of the work was modeling of selected parameters of the water supply system of Łapy city and simulation of intention of connecting new intakes for various location variants. Water supply system of Łapy city with 2300 inhabitants supplied from three intakes was the object of investigations. Average day usage of water is 1 383 m3/d. Majority of water is used by housing and industry and storage terrains. In the first phase of creating the model digital map of Łapy in the scale 1:500 was used and following layers were marked off: net of water supply conductors, borders of plots and buildings. On the base of created map exact values of length and diameters of sections of water supply system and ordinates of individual elements of water supply system were obtained. In order to asses water usage records of readings (years 2006 and 2007) from all water meters located on the water supply system, of total 2056 objects, were taken. In order to verify values pressure in created model of water supply system [1] data loggers of pressure and temperature Cellbox-H were located on selected underground hydrants. Measurements gathered this way were used for comparison and calibration of pressure in given points of net obtained using the model and using real values from data logger. Utilization of measurements of water usage within one year in studied municipal enterprise allows to model average day water demand on the water supply system [2]. Modelling water pressure on the individual sections of water supply system is possible thanks to suitable introduction of data about studied system to programme executing the hydraulic simulation on the base of digital map of the city. In order to obtain credible results it is indispensable to start model on the basis of values of average day water usage and verification of obtained thanks to model pressures with measurements from data logger. Than calibration of model on the basis of executed measurements should be conducted, and next simulation of work in various conditions should be made.
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 605-614
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza hydraulicznej sprawności systemu dystrybucji wody w Jeleniogórskim Zespole Miejskim
Analysis of the Hydraulic Efficiency of the Water Supply Network for City of Jelenia Góra
Autorzy:
Siwoń, Z.
Cieżak, J.
Powiązania:
https://bibliotekanauki.pl/articles/236786.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system dystrybucji wody
sieć wodociągowa
Jeleniogórski Zespół Miejski
Opis:
On the basis of in-situ measurements and computer-aided modelling of the water-pipe network in Jelenia Góra,the values of the parameters describing the real wall roughness of cast-iron and steel pipes in service were determined.The data sets obtained were subject to statistical analysis to quantify the effect of service time,pipe diameter and maximum flow velocity in the pipes during 24 hours on the specific wall roughness values.
Źródło:
Ochrona Środowiska; 1999, 1; 3-6
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przedsięwzięcia służące utrzymaniu lub przywracaniu wymaganej jakości wody w sieci wodociągowej
Measures taken to maintain or re-establish the desired water quality in water-pipe networks
Autorzy:
Denczew, S.
Powiązania:
https://bibliotekanauki.pl/articles/237530.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
sieć wodociągowa
jakość wody
procesy technologiczne
prace modernizacyjne
Opis:
The considerations presented in this paper show that neither the improvement of water quality at the intake nor the modernization of the treatment train is a sufficient preventive measure because of the ever increasing deterioration of water quality in the distribution network. What deserves particular attention of the waterworks management is a continuing modernization or retrofit of the water-pipe system in order to upgrade the quality of the distributed water. In the present paper, a method of maintaining or re-establishing the desired water quality is proposed. The implementation of the method by the management of the Warsaw water distribution system not only has substantiated its utility in improving the quality of tap water, but also enables the operational service staff to intervene in case the quality of the water in the distribution system deteriorates.
Źródło:
Ochrona Środowiska; 2001, 4; 31-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ryzyko awarii magistrali wodociągowej "Iskrzynia" w Krośnie
Risk of water main "Iskrzynia" failure in Krosno
Autorzy:
Studziński, A.
Powiązania:
https://bibliotekanauki.pl/articles/399961.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
magistrala wodociągowa
awaria
ryzyko
water main
failure
risk
Opis:
W pracy przedstawiono analizę ryzyka braku dostawy wody dla miasta Krosna w przypadku awarii magistrali doprowadzającej wodę z ujęcia w Iskrzyni. Przedstawiono wielowa-riantowe symulacje skutków czasowego wyłączenia magistrali przyjmując zmienność rozbioru i napełnienia w zbiornikach sieciowych dla różnych czasów trwania awarii. Podstawą opracowania jest model hydrauliczny systemu zaopatrzenia w wodę. Wyniki symulacji porównano z danymi eksploatacyjnymi uzyskanymi podczas awarii magistrali.
Summary. The work contains risk analysis of water shortage in town of Krosno, resulting from water main failure providing water from Iskrzynia intake. The results of temporary closing this water main were shown for different conditions of water supply system work: water storage tanks filling, water demand, time when the pipeline is closed. The simulations of closing the water main were performed using hydraulical model of water supply system. Relults of the simulations were compared to field data from a failure of the water main.
Źródło:
Inżynieria Ekologiczna; 2011, 26; 247-256
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmian jakości wody w przewodach wodociągowych z wykładziną cementową
Water quality variations in cement-lined water-pipe networks
Autorzy:
Wąsowski, J.
Kowalski, D.
Kowalska, B.
Kwietniewski, M.
Zawilska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236692.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
sieć wodociągowa
wykładzina cementowa
stabilność chemiczna
zanieczyszczenie wody
tap water
water-pipe network
cement lining
chemical stability
water contamination
Opis:
Badania przeprowadzone w instalacji modelowej zasilanej wodą podziemną wykazały, że woda kontaktująca się z wykładziną cementową stopniowo traciła właściwości agresywne i nabierała zdolności do wytrącania węglanu wapnia. Świadczyło to o przechodzeniu składników cementu z wykładziny do wody wodociągowej. Poza głównymi składnikami (wapń, magnez, glin) stwierdzono obecność w wodzie także pierwiastków śladowych (cynk, bar, chrom, ołów, nikiel, kobalt), przy czym nie były to ilości znaczące. Wykazano, że wymywanie pierwiastków z cementu przebiegało intensywniej do wody poddawanej chlorowaniu. Końcowa zawartość wszystkich oznaczonych pierwiastków w wodzie po kontakcie z wykładziną cementową była znacznie poniżej wartości dopuszczalnych w wodzie przeznaczonej do spożycia.
Experiments performed in a model pipe system fed with underground water demonstrated that tap water exposed to cement-lining gradually lost its corrosive properties and continued to develop its potential for calcium carbonate precipitation. This was an indication that cement components were released from the lining into the water residing in the pipes. Apart from its main components (calcium, magnesium and aluminum), the water contained small quantities of trace elements (zinc, barium, chromium, lead, nickel and cobalt). The study produced the following findings: leaching of elements from the cement lining was enhanced upon exposure to chlorinated water, and the final concentration values of all the elements detected in the water after contact with the cement lining were much lower than those permissible for drinking water.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 53-58
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zmian poboru wody w wybranych miastach województwa dolnośląskiego w latach 2005–2010
Evaluation of changes in water consumption in selected cities of lower Silesian Voivodship in 2005–2010
Autorzy:
Szeląg, Z.
Malczewska, B.
Powiązania:
https://bibliotekanauki.pl/articles/950003.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
zużycie wody
sieć wodociągowa
water consumption
water supply network
Opis:
Przedmiotem pracy jest ocena zmian poboru wody w latach 2005–2010, w miastach Oborniki Śląskie, Bystrzyca Kłodzka oraz Kłodzko. Wszystkie miejscowości leżą w województwie dolnośląskim. Różnią się one liczbą mieszkańców oraz stopniem rozwoju różnych gałęzi gospodarki. W pracy przedstawiono zmiany ilości pobranej wody z podziałem na grupy użytkowników oraz ogólną ilość wody wtłoczoną do sieci. Zawarte zostały również informacje o ilości wody sprzedanej przez zakłady wodociągowe oraz wielkości strat wynikających z nieszczelności oraz awarii na sieciach wodociągowych.
The subject of the work is the evaluation of changes in water consumption for the years 2005–2010 in the towns of Oborniki Śląskie, Bystrzyca Kłodzka and Klodzko. All towns are located at the lower Silesian Voivodeship. They differ by its populations and the development of various economy branches. In this paper we are presenting the results of changes in the water uptake by user group and the total amount of water pumped into the network. The information about the quantity of water sold by water plants and the size of the losses resulting from leaks and accidents on the water-supply networks are also included.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 106-114
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba sformułowania w ujęciu systemowym reguły optymalnego osiągnięcia celów technicznych przy rozwiązywaniu problemów projektowych obiektów budowlanych na przykładzie sieci wodociągowych
An attempt of formulating the principle of optimal gain of technical target in resolving problems in design process of building objects in a system approach basing on water supply networks
Autorzy:
Dalewska-Kolan, M.
Podwójci, P.
Powiązania:
https://bibliotekanauki.pl/articles/1819752.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
sieć wodociągowa
projektowanie obiektów budowlanych
water supply
designing buildings
Opis:
Główne zadania, jakie na swojej drodze zawodowej napotykają inżynierowie, związane są z potrzebą, a niejednokrotnie koniecznością, rozwiązywania problemów, które ujawniają się w trakcie cyklów życia obiektów technicznych, to znaczy podczas ich projektowania, wykonywania, użytkowania i eksploatacji. Przez pojęcie "problem", rozumie się nieakceptowany lub niezgodny z preferencjami obecnych lub przyszłych użytkowników i eksploatatorów, istniejący stan obiektu. Rozwiązanie problemu to wskazanie drogi doprowadzającej do przekształcania w postać, której zaistnienie zlikwiduje niezgodności między stanem zastanym a oczekiwanym. W czasach ogromnego nagromadzenia obiektów technicznych uzyskanie poprawnego efektu końcowego, który powinien mieć charakter trwały w stosunku do przewidywanego czasu użytkowania i eksploatacji obiektu, jest prawdziwym wyzwaniem. Współczesne obiekty budowlane (np. sieci wodociągowe) stanowią, układy dynamiczne. Charakteryzują się dużą złożonością samą w sobie. Poza tym, pozostają w obustronnych relacjach z innymi obiektami, z którymi współdziałają, jak również z elementami otoczenia, z którymi współistnieją i funkcjonują [12, 14].
Applying the system thinking to design system, created by humans, makes potential possibilities to define optimal strategies in problem resolving, that is, to select alternative operations in the light of expected effects, to find optimal particular solutions and acceptable costs. The problem of design processes itself is very old. Everybody knows that for centuries scientists and engineers have designed different things. But nowadays designing is becoming more and more complex and complicated due to an increasing number of building investment, and their great density in our environment. System approach to give design engineers of the technical objects (the building objects) a prompt the need for using the following course of reasoning: 1. Each technical object is an artificial system (a gathering of elements) created by man with the aim of the fulfillment of his needs; 2. The technical object (the artificial system) - can be the over-system (higher level) of system and/or the sub-system (lower level) of system. They always are mutually dependent themselves. 3. Technical object exists and functions in definite (identified) surroundings with which stays on an interrelationship. 4. Whole cycle of life of technical object also is the system. Elements of it are individual stages of his existence. There is diverse but exact connection between design decisions and the technical condition of each phase and activities remaining phase. So the system approach for technical problem solving of design processes, requires to meet such conditions as: system must be strictly defined, system shall have hierarchical structure (e.g. horizontally-vertical) proper for the fulfilled tasks, with coordination nature and optimum in relation to the solved problems, system shall include the set of subsystems, assignment of elements and subsystems in this system can be variable, depending on functions fulfilled by them in the given moment. The system approach can help in making better decisions in design processes according to the principle of system approach which says: think globally act locally. In the article authors took the attempt of applying a system approach to formulate rules of operation during designing of the waterworks.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 1279-1289
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyboru optymalnego systemu zaopatrzenia w wodę na przykładzie Polkowic Dolnych
On the Choice of an optimum variant of water supply for the municipality of Polkowice Dolne
Autorzy:
Pawlak, A.
Kotowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/237662.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
zaopatrzenie w wodę
sieć wodociągowa
optymalizacja
Polkowice Dolne
Opis:
The main objective of the study was to establish the optimum variant of water distribution and the management of the water supply system for the period of up to 2005. The choice criterion included the following parameters: hydraulics, reliability, and pumping costs. Considered were three methods of water supply from two independent sources and two variants of water supply management (non-continuous water distribution from the pumping station with the involvement of an equalizing tank; continuous discharge from the pumping station with no equalizing tank). In terms of cost-effectiveness, the optimum pumping costs were those obtained with the variant involving an equalizing tank and 20-hour water distribution from the pumping station of the "Zofiówka" Water Treatment Plant.
Źródło:
Ochrona Środowiska; 2001, 1; 23-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarządzanie jakością wody w systemie wodociągowym
Water quality management in a water distribution system
Autorzy:
Kowalski, D.
Powiązania:
https://bibliotekanauki.pl/articles/236720.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
jakość wody
zarządzanie jakością
sieć wodociągowa
korygowanie jakości wody
water quality
quality management
tap water
water-pipe network
corrective actions
Opis:
Przedsiębiorstwo wodociągowe może być traktowane jako zakład produkcyjny, którego głównym umownym produktem jest woda, zaś podstawowym elementem produkcji jest dostarczanie wody o odpowiedniej jakości do odbiorców. Ujmowanie, oczyszczanie i dostarczanie wody poddawane są procesom planowania, kontroli, analizy oraz działaniom korygującym. Działania korygujące w przypadku przedsiębiorstw wodociągowych realizowane są głównie na wejściu do sieci wodociągowej, natomiast korygowanie jakości wody w samej sieci sprowadza się głównie do płukania i czyszczenia przewodów. W efekcie, w przypadku niedotrzymania wskaźników jakościowych i konieczności płukania przewodów, tracona jest znaczna część wody wodociągowej znajdującej się w systemie. W pracy zaproponowano dwie metody korygowania jakości wody w sieci wodociągowej, przy jednoczesnym ograniczeniu jej strat. Pierwsza wykorzystuje zbiorniki sieciowe, natomiast druga sieciowe stacje doczyszczania wody. Przydatność tych metod w procesie zarządzania jakością wody przetestowano za pomocą obliczeń symulacyjnych na przykładzie dwóch wybranych miast w Polsce. Wyniki symulacji sugerują, że zastosowanie obu metod może prowadzić zarówno do korekty jakości wody w sieci, jak również przyczynić się do ograniczenia skutków przewymiarowania systemów wodociągowych.
In this paper a water company is considered to be a production plant, where water is the main product, and the problem of supplying the user with water of the quality desired constitutes an important part of the production process. The processes of water intake, treatment and supply are made subject to planning, control, analysis and corrective actions. In most instances, corrective actions are taken at the input of the water-pipe network. Water quality correction in the water-pipe network generally includes pipe cleansing and flushing. In consequence, when the water fails to meet the required quality parameters, or when there is a need to flush the pipes, a major part of the water volume stored in the pipeline will be lost. In the paper two methods have been proposed for correcting water quality in the water distribution system, which enable the potential water loss to be reduced. One of these makes use of the storage tanks; the other one uses the network's cleansing and flushing stations. The applicability of the methods to the process of water quality management was tested by computer simulations, choosing two municipal water distribution systems as cases in point. The results suggest that the two methods will not only enable a correction of water quality in the distribution network, but also help reduce the implications of overdesign.
Źródło:
Ochrona Środowiska; 2009, 31, 3; 37-40
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ eksploatacji i stanu technicznego sieci na jakość wody wodociągowej
Influence of technical and operating conditions of the water distribution system on water quality
Autorzy:
Kuś, K.
Gamrot, B.
Malicka, K.
Ścieranka, G.
Powiązania:
https://bibliotekanauki.pl/articles/237728.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
zaopatrzenie w wodę
eksploatacja sieci wodociągowej
woda wodociągowa
jakość wody
Opis:
The combined water supply system being under responsibility of the Upper Silesian Water Board (USWB) basically supplies water to the industry, agriculture and population of Upper Silesia. This is the largest system of that kind operated in Poland and is rather unique in Europe. Water is sold at more than 800 points to water companies, which deliver water to the users in different cities. The ever decreasing water consumption by individual households and industry observed in recent years has brought about a considerable extension of the hydraulic residence time and a deterioration of water quality. The technical condition of the water-pipe network, the hydraulic parameters and water quality variations were analyzed on the example of a water distribution network operated by a local water company that purchases water from the USWB. The objective of the study was to assess the material and age of the pipes, residence time, flow velocity, pressure, as well as the physicochemical and bacteriological parameters at the points of purchase and other characteristic points along the network. Consideration was also given to the frequency of pipe failure and the resulting water loss. A clear definition of the factors that contribute to episodic or long-term deterioration of water quality made it possible to suggest some preventive measures (which had partly been implemented) to maintain or re-establish the desired quality of the water.
Źródło:
Ochrona Środowiska; 2001, 3; 17-20
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość wykorzystania danych o awariach sieci wodociągowej w procesie planowania jej remontu
Possibility of using data on the water supply network failures in the planning of its repair
Autorzy:
Piegdoń, I.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/104853.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
awaryjność
sieć wodociągowa
remont
GIS
failure
water network
repair
Opis:
W badaniach prowadzonych nad niezawodnością i bezpieczeństwem funkcjonowania systemów wodociągowych, podstawą wszelkich badań i analiz stanowią dane eksploatacyjne dotyczące sieci wodociągowej, opracowane na bazie dzienników i protokołów awarii prowadzonych w każdym przedsiębiorstwie wodociągowym. Systematycznie prowadzone badania awaryjności obejmujące swoim zakresem analizę przyczyn, skutków, rodzaju awarii oraz ich liczby, pozwalają osobom decyzyjnym w przedsiębiorstwie podjąć odpowiednie działania odnośnie planowania remontów na sieci oraz zarządzania pracą brygad remontowych. W pracy zaprezentowano analizę awaryjności wybranej sieci wodociągowej województwa podkarpackiego. Wyszczególniono przyczyny awarii oraz ich sezonowość. Wyniki analiz oparto o dane eksploatacyjne z kilku ostatnich lat. Dodatkowo przedstawiono możliwość wykorzystania danych o awariach w procesie planowania remontów przewodów wodociągowych. W tym celu zaprezentowano możliwości stosowania mapy numerycznej oraz bazy danych GIS.
In research on the reliability and safety of water supply systems operation, the basis for all research and analyzes are operational data on the water supply network, developed on the basis of logs and failure protocols carried out in each water supply company. Systematically performed failures, including the analysis of causes, consequences, type of failures and their number, allow decisionmakers in the enterprise to take appropriate actions regarding the planning of repairs on the network and management of maintenance brigades. The paper presents the failure analysis of a selected water supply network of the Podkarpackie region. The reasons for the failure and their seasonality are detailed. The results of analyzes were based on operational data from the last few years. Additionally, the possibility of using data on failures in the process of planning repairs of water pipes was presented. Due to this, the possibilities of using a numerical map and the GIS database were presented.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 4/II; 199-210
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie heterotroficznych bakterii z rodzaju Aeromonas w wybranym systemie dystrybucji wody
Occurrence of heterotrophic bacteria of the genus Aeromonas in a water distribution system: A case study
Autorzy:
Kręgiel, D.
Rygała, A.
Powiązania:
https://bibliotekanauki.pl/articles/237313.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
biofilm
adhezja
luminometria
tap water
adhesion
luminometry
Opis:
Hetrotroficzne bakterie Aeromomas sp występują powszechnie w środowisku wodnym, a niektóre z nich są patogenami dla ludzi i ryb. Występowanie bakterii Aeromonas hydrophila badano w systemie dystrybucji wody podziemnej, nie poddanej chlorowaniu. Badania przeprowadzono systematycznie w ciągu całego roku. Stwierdzono, że bakterie z rodzaju Aeromonas były wykrywane w wodzie wodociągowej w miesiącach letnich, od maja do października, przy czym największy wzrost liczby bakterii wynoszący 156 jtk/100 cm3 odnotowano w sierpniu. Około 80% wyizolowanych szczepów, wykazujących zdolność [beta]-hemolizy, zidentyfikowano jako Aeromonas hydrophila. Wyizolowane bakterie adherowały do powierzchni PVC, materiału powszechnie stosowanego w instalacjach wodociągowych. Biorąc pod uwagę zarówno silne właściwości adhezyjne Aeromonas sp., które stymulują tworzenie biofilmu, jak i możliwość występowania różnych czynników wirulencji warunkujących ich chorobotwórczość, należy rozważyć włączenie pałeczek z rodzaju Aeromonas do rutynowych badań mikrobiologicznych wody, a zwłaszcza do monitoringu funkcjonowania sieci i urządzeń wodociągowych.
Heterotrophic strains of Aeromonas sp. are ubiquitous in aquatic environments, but some of them have a pathogenic impact on humans and fish. Samples were taken regularly over a one-year period from a system distributing unchlorinated groundwater, which was analyzed for the presence of Aeromonas hydrophila. Bacteria of the genus Aeromonas were detected in tap water samples collected from May to October, the largest increase in the number of these bacteria (156 cfu/100 cm3) being observed in August. Approximately 80% of the isolated strains, with a capacity for [beta]-hemolysis, were identified as Aeromonas hydrophila. The bacteria showed the ability to adhere to the surface of PVC, a material widely used in water-supply systems. Taking into account, on the one hand, the strong adhesion properties of Aeromonas sp., which stimulate biofilm formation, and considering, on the other hand, the occurrence of various virulence factors that underlie the pathogenicity of Aeromonas sp., it seems recommendable to include rods of the genus Aeromonas not only into routine microbiological analysis of tap water, but also into the monitoring of the functioning of water distribution systems.
Źródło:
Ochrona Środowiska; 2010, 32, 4; 47-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wysokości ciśnienia na uszkadzalność i koszty napraw sieci wodociągowej
Effect of pressure head on the rate of failure and repair costs of water-pipe networks
Autorzy:
Hotloś, H.
Powiązania:
https://bibliotekanauki.pl/articles/237738.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
sieć wodociągowa
ciśnienie wody
niezawodność systemów wodociągowych
koszty eksploatacji
Opis:
Reliability of water supply to the user can be increased, e.g., by limiting excessive pressure in the water-pipe network, thus decreasing the rate of pipe failure, the volume of water loss in the pipeline and related operating costs. For the needs of the present study, use was made of the data sets (provided by the Waterworks of Wrocław) which had been collected during eight years of pipeline operation in two housing estates. The effect of pressure head on failure rate and repair cost was examined in terms of the following parameters: pipe material, pipe diameter, type of pipe damage, type of fittings damage, duration of service and year of pipeline construction. Data on the costs of pipeline and fillings repair covered the year 1999. The study has shown that the reduction of excessive pressure in the investigated pipeline brought about a noticeable decrease in the indices of damage and repair cost flow for the given water-pipe network Such indices may be of utility in budget planning, and also in finding the optimal decision with respect to the operation or retrofit of existing water-pipe lines.
Źródło:
Ochrona Środowiska; 2001, 2; 31-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies