Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "partial discharges" wg kryterium: Temat


Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt badawczo-rozwojowy SORAL – system oceny stanu technicznego i ryzyka awarii linii kablowych SN oparty o badania diagnostyczne wykonywane w trybie off line
SORAL - system for condition monitoring and failure risk assessment of MV cable lines based off line diagnostic methods
Autorzy:
Noske, Sławomir
Zasada-Chruścińska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/267590.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
pomiary diagnostyczne kabli
pomiary wyładowań niezupełnych
pomiary tangensa delta
Health Index
Diagnostic measurements of cables
partial discharges
tangent delta measurements
health Index
Opis:
Sieć kablowa średniego napięcia (SN) stanowi istotny element sieci dystrybucyjnej. Dotychczasowe zarządzanie tą częścią sieci jest głównie oparte na analizach awaryjności, tzn. wzrost liczby awarii na danej linii świadczy o pogarszającym się stanie technicznym. Jest to system mało efektywny, wiąże się z dodatkowymi kosztami usuwania awarii, przerwami w dostawie energii, utrudnionym planowaniem inwestycji i prac eksploatacyjnych. Planowane, w ramach projektu SORAL, prace badawczo-rozwojowe mają doprowadzić do wdrożenia zarządzania siecią kablową SN opartego na wymiernej ocenie stanu technicznego poszczególnych elementów linii. Podstawą prac jest wykorzystanie pomiarów diagnostycznych. Analizy rynku i doświadczenia Energa Operator SA z pracy w międzynarodowych stowarzyszeniach wskazują, że projekt ma charakter innowacyjny na poziomie światowym.
The article describes the current experience in applying the diagnostics of MV cable lines in the DSO and the ongoing SORAL project. Diagnostic systems which measure partial discharges and tan delta in MV lines have been used in Poland since the turn of the century. Research work so far has focused on MV cables and on attempts to define key parameters which would indicate advanced ageing processes. The measurements and analyses conducted so far have not enabled the formulation of assessment criteria for failure risk. However, key parameters indicating the increase in the failure risk have been identified. The research up to now is a valuable contribution to the process of creating assessment criteria for failure risk, using the IT system which automates this process. This task is carried out now in the SORAL project. The project is implemented by DSO (ENERGA-OPERATOR) and IT Company (Globema) consortium and is financed from EU funds.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 23-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilot implementation of the on-line partial discharge monitoring system for heads of the high voltage cable lines
Autorzy:
Konarski, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/220896.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable lines diagnostics
partial discharges
unconventional methods of partial discharges measurement
UHF electromagnetic method
Opis:
The article presents the assumptions, characteristics and description of the implementation of a pilot system for on-line monitoring of partial discharges in heads of the high-voltage cable lines. The main purpose of the implementation was to increase the reliability of cable line heads by equipping them with a system of continuous assessment of technical condition with direct transmission of measurement data and alarms to the SCADA system. In order to achieve the assumed goal, unconventional methods for measuring partial discharges were used, the application of which does not require disconnecting the line from the voltage. The implementation was carried out on an active 110 kV high voltage cable line in the area of activity of one of the Distribution System Operators.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 373-382
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charge dynamics of partial discharges explored applying a chopped sequence
Autorzy:
Florkowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2086894.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
chopped sequence
high voltage insulation
non-invasive diagnostics
wyładowania niezupełne
sekwencja posiekana
izolacja wysokiego napięcia
diagnostyka nieinwazyjna
Opis:
Diagnostic methodologies are of fundamental importance for operational strategies of electrical devices, both in the power grid and in industrial applications. This paper reports about a novel approach based on partial discharge analysis applied to high voltage electrical insulation. Especially dynamics of charges deposited by partial discharges is explored applying a chopped sequence. The applications refer to microvoids occurring inside solid insulating systems or at the interfaces, such as delaminations at the electrodes. The experiments were carried out on embedded voids having distinctive wall dielectric materials. The underlying physical phenomena of post discharge charge transport are analyzed. The assessment is performed using phase-resolved partial discharge patterns acquired applying a chopped sequence. The chopped partial discharge (CPD) method provides quantitative insight into post discharge charge decay processes due to deposited and accumulated charges fluctuations. The assessment indicator is based on comparing partial discharge inception angle between chopped sequence and continuous run. The experiments have shown that materials with distinctive surface conductivity revealed adequately different charge decay time dynamics. The detailed analysis yields time constant of walls charge decay for insulating paper equal to 12 ms and cross-linked polyethylene 407 ms. The CPD method may be further used to investigate streamer physics inside bounded cavities in the form of voids. The presented method provides a quantitative approach for charge non-invasive decay assessment and offers high potential in future diagnostics applications.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 5; e138817, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Selected Hierarchical Clustering Methods for Classification the Acoustic Emission Signals Generated by Partial Discharges
Autorzy:
Borucki, Sebastian
Łuczak, Jacek
Lorenc, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2097707.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
power transformer
clustering method
Opis:
The paper presents the results of the application of the hierarchical clustering methods for the classification of the acoustic emission (AE) signals generated by eight basic forms of partial discharges (PD), which can occur in paper-oil insulation of power transformers. Based on the registered AE signals from the particular PD forms, using a frequency descriptor in the form of the power spectral density (PSD) of the signal, their representation in the form of the set of points on plane XY was created. Next, these sets were subjected to analysis using research algorithms consisting of selected clustering methods. Based on the suggested numeric performance indicators, the analysis of the degree of reproduction of the actual distribution of points showing the particular time waveforms of the AE signals from eight adopted PD forms (PD classes) in the obtained clusters was carried out. As a result of the analyses carried out, the clustering algorithms of the highest effectiveness in the identification of all eight PD classes, classified simultaneously, where indicated. Within the research carried out, an attempt to draw general conclusions as to the selection of the most effective hierarchical clustering method studied and the similarity function to be used for classification of the selected basic PD forms.
Źródło:
Archives of Acoustics; 2021, 46, 3; 409-417
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of layout and concentration of defects on the electromechanical constraints in the MV cables insulation
Autorzy:
Medoukali, Hemza
Zegnini, Boubakeur
Powiązania:
https://bibliotekanauki.pl/articles/2203642.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnosing
microcavities
density
electromechanical
XLPE
MV
FEM
partial discharges
diagnostyka
mikrowgłębienia
gęstość
wyładowanie niezupełne
metoda elementów skończonych
Opis:
The problem of the dense presence of voids in the solid insulation of cables remains a concern for researchers in terms of diagnosis and maintenance. The focus of this paper is to investigate the influence of both the layout and density of microcavities on the electrical and electromechanical constraints in the XLPE insulation of MV cables using numerical simulation. The simulation is based on the resolution of Laplace’s equation by the finite element method (FEM) using MATLAB. The electrostatic pressure and the elongation of the microcavities are estimated. This elongation leads to the formation of microchannels and then develops due to partial discharges to arborescence and in the end, the cable becomes out of service. This process takes a long time, so we use simulations to deepen the understanding of this phenomenon in a very short time. The electromechanical constraints are determined for different layouts and densities of microcavities.
Źródło:
Diagnostyka; 2023, 24, 2; art. no. 2023206
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies