Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "winding" wg kryterium: Temat


Tytuł:
A transformer winding deformation detection method based on the analysis of leakage inductance changes
Autorzy:
Jiansheng, L.
Fengbo, T.
Chao, W.
Yuncai, L.
Peng, W.
Mengzhou, Z.
Miao, Y.
Powiązania:
https://bibliotekanauki.pl/articles/140628.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condition-based maintenance
winding deformation
leakage inductance
partial least squares regression
Opis:
The detection of transformer winding deformation caused by short-circuit current is of great significance to the realization of condition based maintenance. Considering the influence of environment and measurement errors, an online deformation detection method is proposed based on the analysis of leakage inductance changes. First, the operation expressions are derived on the basis of the equivalent circuit and the leakage inductance parameters are identified by the partial least squares regression algorithm. Second, the amount of the leakage inductance samples in a detection time window is determined using the Monte Carlo simulation thought, and then the samples in the confidence interval are obtained. Last, a criteria is built by the mean value changes of the leakage inductance samples and the winding deformation is detected. The online detection method considers the random fluctuation characteristics of the leakage inductance samples, adjust the threshold value automatically, and can quantify the change range to assess the severity. Based on the field data, the distribution of the leakage inductance samples is analyzed to obey the normal function approximately. Three deformation experiments are done by different sub-winding connections and the detection results verify the effectiveness of the proposed method.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 333-346
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic characterization of the nickel layer protecting the copper wires in harsh applications
Autorzy:
Roger, D.
Duchesne, S.
Iosif, V.
Powiązania:
https://bibliotekanauki.pl/articles/140802.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high temperature motor winding
nickel diffusion barrier
temperature dependent magnetic properties
Opis:
High Temperature (HT°) motor coils open new perspectives for extending the applications of electrical motors or generators to very harsh environments or for designing very high power density machines working with high internal temperature gradients. Over a temperature of 300E°, the classic enameled wire cannot work permanently, the turn-to-turn insulation must be inorganic and made with high temperature textiles or vitro-ceramic compounds. For both cases, a diffusion barrier must protect the copper wire against oxidation. The usual solution consists of adding a nickel layer that yields an excellent chemical protection. Unfortunately, the nickel has ferromagnetic properties that change a lot the skin effect in the HT wire at high frequencies. For many applications such as aeronautics, electrical machines are always associated with PWM inverters for their control. The windings must resist to high voltage short spikes caused by the fast fronted pulses imposed by the feeding inverter. The nickel protection layer of the HTE inorganic wire has a large influence on the high frequency behavior of coils and, consequently, on the magnitude of the voltage spikes. A good knowledge of the non-linear magnetic characteristics of this nickel layer is helpful for designing reliable HT inorganic coils. The paper presents a method able to characterize non-linear electromagnetic properties of this nickel layer up to 500E°.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 253-263
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic system for induction motor stator winding faults based on axial flux
Autorzy:
Wolkiewicz, M.
Skowron, M.
Powiązania:
https://bibliotekanauki.pl/articles/1193462.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stator winding fault
inter-turn short circuit
axial flux
diagnostic system
Opis:
The article presents the results of research on the use of an axial flux in the diagnostics of induction motor stator winding fed by a frequency converter. Voltage signal waveforms proportional to the axial flux were recorded during motor operation under various conditions and were analyzed with regard to the detection of stator winding short circuits. The taps of the selected coil turns of stator phases were introduced into the tested motor, which allowed to physical modelling inter-turn short circuits. The structure and operation of the computer system used to monitor the state of induction motor windings were discussed. The developed diagnostic system was made in the National Instruments LabVIEW environment. The analysis of faults of the axial flux was made in the detection of induction motor stator winding. The results of experimental research conducted using the developed diagnostic system have also been presented.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 137-150
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of star-delta mixed stator winding in permanent magnet synchronous machines with permanent magnets on the rotor surface
Zastosowanie uzwojenia mieszanego stojana typu gwiazda-trójkąt w maszynach synchronicznych o magnesach trwałych
Autorzy:
Gwoździewicz, M.
Gawron, S.
Powiązania:
https://bibliotekanauki.pl/articles/1807525.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
higher harmonics
synchronous motor
synchronous generator
permanent magnet
winding factor
windings
Opis:
W artykule przedstawiono rezultaty zastosowania uzwojenia mieszanego stojana typu gwiazdatrójkąt w maszynach synchronicznych o magnesach trwałych. Na bazie produkowanej przez KOMEL maszyny synchronicznej o magnesach trwałych typy PMGg180L-8 został zbudowany model polowoobwodowy w programie Maxwell wersja 14. Zbadano wpływ zastosowania uzwojenia mieszanego stojana typu gwiazda trójkąt na występowanie wyższych harmonicznych oraz właściwości eksploatacyjne maszyn synchronicznych o magnesach trwałych.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2011, 65, 31; 55-63
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne aspekty diagnostyki odkształceń uzwojeń transformatorów metodą analizy ich odpowiedzi częstotliwościowej (FRA)
Practical issues of transformer windings mechanical condition diagnostics by means of frequency response analysis (FRA)
Autorzy:
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/153183.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator
odkształcenie uzwojenia
odpowiedź częstotliwościowa
FRA
transformer
winding deformation
frequency response
Opis:
Średni wiek transformatorów eksploatowanych w Polsce ustawicznie się wydłuża. Obecnie ponad połowa ich populacji pracuje jest ponad 25 lat. Dlatego ważnym zagadnieniem jest znajomość ich stanu technicznego. Wśród wielu metod diagnozowania stanu technicznego transformatorów coraz większą popularność zdobywa analiza odpowiedzi częstotliwościo-wej uzwojeń transformatora (Frequency Response Analysis - FRA). Służy ona do diagnozowania stanu mechanicznego uzwojeń - ich odkształceń osiowych i promieniowych, jak i zwarć między zwojami. W artykule przedstawiono podstawowe informacje na temat tej metody i omówiono wpływ różnych czynników na rejestrowane przebiegi, takich jak konfiguracja przewodów pomiarowych, sposób ich podłączenia i rodzaj wybranego systemu diagnostycznego. Zaproponowano poprawkę unifikującą rejestracje systemów o różnych impedancjach kabli. Omówiono także wpływ innych czynników na rejestracje FRA i ich poprawną interpretację.
The average age of transformers operated in Poland is constantly increasing. At present over half of them is operated over 25 years. Therefore it is very important to recognize their technical condition. One of transformers' diagnostic methods is Frequency Response Analysis - FRA. It is used for diagnostics of windings' mechanical condition - their axial and radial deformations and local short-circuits. The paper presents basic information on this method and influence of various factors on measured curves, such as: configuration and arrangement of measuring cables or type of measuring device. The correction coefficient has been suggested to unify results measured by devices with different impedances of measuring cables. The influence of other factors on FRA measurements and their correct interpretation has also been given.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 10, 10; 720-722
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Armature MMF and electromagnetic performance analysis of dual three-phase 10-pole/24-slot permanent magnet synchronous machine
Autorzy:
Chen, Zhenfei
Xing, Ning
Ma, Hongzhong
Li, Zhixin
Li, Jiayu
Fan, Chenyang
Powiązania:
https://bibliotekanauki.pl/articles/2202550.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dual three-phase winding
fractional-slot
concentrated winding
permanent magnet synchronous machines (SCW-PMSMs)
MMF harmonic analysis
space harmonics
magnet eddy-current loss (ECL)
SVPWM voltage supply
Opis:
Fractional-slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs) have a good prospect of application in the drive system of electric and hybrid electric vehicles. However, the armature magnetomotive force (MMF) of FSCWPMSM contains a large number of space harmonics, which induce large magnet eddycurrent loss (ECL). To solve this problem, a dual three-phase 10-pole and 24-slot winding layout is proposed.MMFharmonic analysis shows that the 1st, 7th and 17th space-harmonic winding factors of the proposed winding can be reduced by 100%, 87% and 87% respectively, compared with a dual three-phase 10-pole and 12-slot winding. Electromagnetic performances of the proposed machine under rated sinusoidal current supply and space vector pulse-width-modulated (SVPWM) voltage supply are investigated based on 2D finite-element analysis. It is shown that the proposed machine can meet the requirement of torque and efficiency in the full speed range. Especially, magnet ECL can be reduced greatly due to the reduction of the 7th and 17th space harmonics.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 189--210
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of frequency response of transformer winding with axial deformations
Autorzy:
Gawrylczyk, K. M.
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/140733.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transformer
winding
frequency response analysis (FRA)
lumped parameters method
transmission line method
Opis:
One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows to determine the mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. Still pending problem is interpretation of measurements results. One of approaches is application of computer modeling to simulate various failure modes and connected with them changes in FRA response. The paper presents two types of models, one based on lumped parameters with RLC elements, and one based on distributed parameters with TLM method. Both methods give similar results, comparable to real measurements of simulated coil.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 5-17
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the proximity and skin effects on copper loss in a stator core
Autorzy:
Młot, A.
Korkosz, M.
Grodzki, P.
Łukaniszyn, M.
Powiązania:
https://bibliotekanauki.pl/articles/141349.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
end winding
copper loss
iron loss
ac loss
skin effect
proximity effect
Opis:
Accurate prediction of power loss distribution within an electrical device is highly desirable as it allows thermal behavior to be evaluated at the early design stage. Three-dimensional (3-D) and two-dimensional (2-D) finite element analysis (FEA) is applied to calculate dc and ac copper losses in the armature winding at high-frequency sinusoidal currents. The main goal of this paper is showing the end-winding effect on copper losses. Copper losses at high frequency are dominated by the skin and proximity effects. A time-varying current has a tendency to concentrate near the surfaces of conductors, and if the frequency is very high, the current is restricted to a very thin layer near the conductor surface. This phenomenon of nonuniform distribution of time-varying currents in conductors is known as the skin effect. The term proximity effect refers to the influence of alternating current in one conductor on the current distribution in another, nearby conductor. To evaluate the ac copper loss within the analyzed machine a simplified approach is adopted using one segment of stator core. To demonstrate an enhanced copper loss due to ac operation, the dc and ac resistances are calculated. The resistances ratio ac to dc is strongly dependent on frequency, temperature, shape of slot and size of slot opening.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 211-225
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of properties of induction machine with combined parallel star-delta stator winding
Analiza właściwości maszyny indukcyjnej z uzwojeniem stojana połączonym gwiazda-trójkąt
Autorzy:
Schreier, L.
Bendl, J.
Chomat, M.
Powiązania:
https://bibliotekanauki.pl/articles/1199581.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
induction machine
parallel combined stator winding
maszyna indukcyjna
równolegle polączone uzwojenie stojana
Opis:
W artykule przeanalizowano właściwości maszyny z równoległym połączeniem uzwojenia stojana. Analizę prowadzono w zakresie liczby przewodów delta i połączonego w gwiazdę uzwojenia. Przedstawiono wpływ stosunku liczby przewodów tych uzwojeń do możliwości stłumienia wyższych harmonicznych przestrzennych i dotyczących sprawności urządzenia. Pochodne równania maszyny z połączonym uzwojeniem stojana opisują zachowanie maszyny, zarówno w stanie ustalonym, nieustalonym oraz podczas awarii.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 1, 113; 147-153
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie falownika średniego napięcia do modernizacji napędów maszyn wyciągowych górniczych wyciągów szybowych
The use of a medium-voltage inverter for the modernization of winders in mining shafts
Autorzy:
Małczak, C.
Materzok, A.
Manczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/187489.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
górnicze wyciągi szybowe
modernizacja
maszyny wyciągowe
mining shafts
modernization
winders
winding machine
Opis:
W artykule przedstawiono wnioski po przeprowadzonej modernizacji maszyny wyciągowej. Modernizację tę przeprowadzono z wykorzystaniem falowników średniego napięcia. Opisano i przedyskutowano sprawność maszyny, a także wpływ zastosowanego rozwiązania na jakość energii elektrycznej sieci zasilającej.
The article feature conclusions drawn after the modernization of a winder. The modernization was conducted with the use of medium-voltage inverters. The efficiency of the winder was described and discussed along with the impact of this solution on the quality of energy in the power supply network.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2011, R. 49, nr 8, 8; 61-68
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie długości uzwojenia w słupach żelbetowych
Calculation of the winding length in the reinforced concrete poles
Autorzy:
Grabowski, R. J.
Powiązania:
https://bibliotekanauki.pl/articles/402924.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
słupy żelbetowe
długość uzwojenia
zbrojenie spiralne
concrete pole
winding length
reinforcement spiral
Opis:
Opracowano sposoby obliczania długości uzwojenia w słupach żelbetowych o przekroju prostokątnym, kołowym i eliptycznym. Problem ten jest dość ogólnikowo ujęty w literaturze i w zaleceniach normowych. Przedstawione w pracy sposoby obliczeń mogą być zastosowane w praktyce.
The ways of calculating the length of the winding in the reinforced concrete poles with rectangular, circular and elliptical section were developed. This problem is quite generally described in literature and standard recommendations. The presented methods of calculation may be used in practice.
Źródło:
Budownictwo i Inżynieria Środowiska; 2015, 6, 1; 5-9
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka silników wykorzystująca wielkości pomiarowe aparatury zabezpieczeniowej
Autorzy:
Juszczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/302840.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
diagnostyka silnika
awaria silnika
uzwojenie stojana
engine diagnostics
engine failure
stator winding
Opis:
Silniki stanowią ważny element systemu produkcyjnego, a brak ich dostępności może wiązać się z poważnymi stratami dla przedsiębiorstwa. W ostatnim stuleciu widoczne jest przesunięcie strategii Utrzymania Ruchu z oczekiwania na awarię silnika (strategia reaktywna – początek XX wieku) na proaktywną. Obecnie dostępne są bardzo złożone systemy monitoringu wykrywające anomalie w silnikach. Poprzez porównywanie różnych przetworzonych informacji, zebranych w czasie pracy silnika, pozwalają wykrywać pogarszanie się jego stanu technicznego i sygnalizować obsłudze konieczność interwencji w dogodnym momencie dla procesu produkcyjnego. Okazuje się, że takie zadania diagnostyczne może również realizować przekaźnik zabezpieczeniowy silnika, w oparciu o analizę mierzonych przez niego parametrów elektrycznych. Przykładem takiej diagnostyki jest wykrywanie uszkodzenia prętów wirnika, wykrywanie zwarć zwojowych stojana czy też kompleksowa diagnostyka ESA, bazująca na MCSA, zaimplementowana w zabezpieczeniu silnika Multilin 869 firmy General Electric (GE).
Źródło:
Napędy i Sterowanie; 2018, 20, 9; 100-110
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decentralized PI controller for multimotors web winding system
Autorzy:
Bouchiba, B.
Hazzab, A.
Glaoui, H.
Med-Karim, F.
Bousserhane, I. K.
Sicard, P.
Powiązania:
https://bibliotekanauki.pl/articles/384405.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
multi motors web winding system
PI controller
tension control
linear speed control
Opis:
Web winding systems allow the operations of unwinding and rewinding of various products including plastic films, sheets of paper, sheets, and fabrics. These operations are necessary for the development and the treatment of these products. Web winding systems generally consist of the same machine elements in spite of the diversity of the transported products. Due to the wide rang variation of the radius and inertia of the rollers the system dynamic change considerably during the winding/ unwinding process. Decentralized PI controller for web tension control and linear speed control are presented in this paper. The PI control method can be applied easily and is widely known, it has an important place in control applications. Simulation results show the effectiveness of the proposed linear speed and tension controller for web winding multi motors systems.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 2; 32-36
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-intrusive current-based fault detection of electro-mechanical actuators with brushed DC motors
Autorzy:
Hanuš, Ondřej
Smid, Radislav
Powiązania:
https://bibliotekanauki.pl/articles/2173890.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Electro-mechanical Actuator
EMA
Fault Detection and Diagnostics
FDD
jam
winding short
Opis:
This paper proposes data-based fault detection methods for an electromechanical actuator (EMA) with a brushed DC motor. The jam and winding short faults are considered in the study as the most prominent EMA faults. The fault detection is based on evaluating the properties of the motor current, considering the basic electromechanical parameters of EMAs. The main advantages are a non-intrusive approach utilising a commonly accessible motor current measurement, simple configurability, and the ability to detect faults under varying operation modes of EMA, including changes of speed, load, or movement profiles. The proposed methods have been evaluated with a custom testing system, and the results have proven the performance of the proposed approach to detect faults under varying operating conditions in industrial applications.
Źródło:
Metrology and Measurement Systems; 2022, 29, 3; 505--523
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit modelling of an advanced welding transformer with two parallel rectifiers
Autorzy:
Sakhno, L.
Sakhno, O.
Dubitsky, S.
Powiązania:
https://bibliotekanauki.pl/articles/141600.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arc welding
double-bridge rectifier
leakage inductance
three-winding transformer
transformer equivalent circuit
Opis:
The new topology of three-winding welding transformer is proposed. Each secondary winding is connected in parallel through the separate bridge rectifier to the welding arc. The main feature of the proposed device is parallel working of two secondary windings with different rated voltage. The advantage is nonlinear transformation ratio of current that provides unprecedented power efficiency. The self- and mutual leakage inductances, which are important in power conversion, are calculated by 2D FEA model. The operational current of the device is modelled numerically via P-Spice simulator. The proposed topology is up to 30% more power effective than conventional welding transformer provided that the leakage inductances of primary and secondary windings are correctly fitted. This transformer is used for manual arc welding.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 249-257
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies