Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cooling power" wg kryterium: Temat


Tytuł:
Maximisation of Combined Cycle Power Plant Efficiency
Maksymalizacja sprawności elektrowni gazowo-parowych
Autorzy:
Kotowicz, J.
Job, M.
Brzęczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397508.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
combined cycle power plant
turbine cooling
thermodynamic optimisation
elektrownia gazowo-parowa
chłodzenie turbiny
optymalizacja
Opis:
The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.
W artykule przedstawiono koncepcje zwiększenia sprawności nowoczesnej elektrowni gazowo-parowej. Poprawa charakterystyk pracy turbiny gazowej oraz wykorzystanie ciepła powietrza chłodzącego układ przepływowy turbiny gazowej pozwalają na osiągnięcie sprawności elektrycznej brutto rzędu 65%. Analizy przeprowadzono w szerokim zakresie stopni sprężania w kompresorze. Sporządzono główne charakterystyki pracy analizowanego układu gazowo-parowego dla różnych typów chłodzenia otwartego powietrzem ekspandera turbiny gazowej: konwekcyjnego, transpiracyjnego oraz błonowego.
Źródło:
Acta Energetica; 2015, 4; 42-53
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency of failures in selected urban vehicle systems
Autorzy:
Rymarz, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1819085.pdf
Data publikacji:
2020
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
system failure
public transport bus
seasonality
cooling system
power supply systems
driving system
engine
Opis:
The aim of this study was to examine the relationship between the occurrence of selected types of failures and the time and season of their occurrence in public transport buses in the city of Lublin. The analysis was carried out for buses operated in the Municipal Transport Company within the past 3 years. The chi-squared analysis showed that during operation, there are significant differences between the failures and the annual season, but there are no differences between the frequency of failures and the time of day.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2020, 64 (136); 9-13
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic Safety Assessment of ESBWR gravity driven cooling system
Autorzy:
Kaszko, Aleksej
Niewiński, Grzegorz
Stępień, Michał
Powiązania:
https://bibliotekanauki.pl/articles/132047.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
nuclear power plant
Probabilistic Safety Assessment
PSA
Fault Tree Analysis
FTA
Gravity Driven Cooling System
GDCS
Opis:
According to Polish nuclear law, newly emerging nuclear facilities require probabilistic safety assessment (PSA). This article is intended to present the PSA method and to present the error tree method by which the probability of unavailability of the gravity reactor cooling system (GDCS) of the ESBWR power plant designed by GE Hitachi was determined. This work includes creatiion process of a damage tree and performing a quantitative analysis in SAPHIRE tool and estimating uncertainty using the Monte Carlo method. As a part of the work, it was shown that in the probability of failure of a single GDCS P LINE-A line, the most important element are the basic events related in particular to the operation of service valves.
Źródło:
Modern Engineering; 2020, 1; 18-25
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat power determination of Dv-290 refrigerator’s evaporator on the basis of thermodynamic parameters of inlet air
Określenie mocy cieplnej parownika chłodziarki Dv-290 na podstawie parametrów termodynamicznych powietrza wlotowego
Autorzy:
Nowak, B.
Kuczera, Z.
Powiązania:
https://bibliotekanauki.pl/articles/218808.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc cieplna
air conditioning of mines
air cooling
compression refrigerator
thermal power
Opis:
The present paper introduces a method for calculating the thermal power of DV-290 mining air cooler’s evaporator. The power usually differs from the nominal power given by the manufacturer. The thermodynamic parameters of cooled air are not obtained as a result of in situ measurements, but in indirect manner that is by determining the evaporation and condensation’s pressure values of R407C refrigerant. The pressure dependencies formulated as a function of air enthalpy at the evaporator’s inlet were obtained using calculations of a computer program which solves the system of equations describing heat and mass transfer in the refrigerator’s compressor on the basis of previous measurements of air performed before and after its cooling. The obtained dependencies are demonstrated in a graphical (fig. 2 and fig. 3) and analytical (the regression equations (19) and (20)) manner, the values of correlation coefficients are also presented. For the known evaporation and condensation pressure values of the refrigerant, and thus for its basic physical parameters the complete thermal power of the evaporator was determined, that is its: air cooling overt power, dehumidification occult power, temperature, relative humidity and specific humidity of air after its cooling. In addition, using the mentioned method, the capacity of DV-290 refrigerator’s evaporator is provided for the given thermodynamic parameters of air before cooling, along with air thermodynamic parameters after cooling.
W pracy zaproponowano metodę obliczania mocy cieplnej parownika górniczej chłodziarki powietrza DV-290. Moc ta zazwyczaj jest różna od mocy znamionowej podanej przez jej producenta. Wymaganą znajomość parametrów termodynamicznych schłodzonego powietrza otrzymuje się, nie jak dotychczas w wyniku ich pomiarów in situ, lecz drogą pośrednią wyznaczając najpierw wartości ciśnień parowania i skraplania czynnika chłodniczego R407C. Odpowiednie zależności tych ciśnień w funkcji jednostkowej entalpii powietrza na wlocie parownika otrzymano, na podstawie wcześniejszych pomiarów parametrów powietrza przed i po jego schłodzeniu, z obliczeń utworzonym programem komputerowym rozwiązującym układ równań opisujący wymianę ciepła i masy w chłodziarce sprężarkowej. Uzyskane zależności przedstawiono w sposób graficzny (rys. 2 i rys. 3) oraz analityczny - równania regresji (19) i (20), podając też wartości współczynników korelacji. Dla znanych wartości ciśnień parowania i skraplania czynnika chłodniczego, a więc także i jego podstawowych parametrów fizycznych, korzystając z wymienionego programu komputerowego, wyznaczono, w funkcji jednostkowej entalpii powietrza na wlocie parownika, całkowitą jego moc cieplną z podziałem na moc jawną ochładzania powietrza, utajoną moc osuszania powietrza, temperaturę, wilgotność względną i wilgotność właściwą powietrza po jego ochłodzeniu. Podano też, dla przykładowych zadanych parametrów termodynamicznych powietrza przed jego schłodzeniem obliczone wspomnianą metodą, moce parownika chłodziarki DV-290 oraz parametry termodynamiczne powietrza po schłodzeniu.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 911-920
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The results of the experimental research of the heat transfer coefficient during steam condensation in the tubes of the diesel radiator sections
Rezultaty ehksperimenthykh issledovanijj koehfficienta teplootdanykh pri kondensacii para v trubkakh teplovoznykh radiatornykh sekcijj
Autorzy:
Sklifus, Y.
Mohyla, V.
Powiązania:
https://bibliotekanauki.pl/articles/792234.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
experimental research
heat transfer coefficient
heat transfer ratio
diesel locomotive
phase transition
cooling system
power plant
steam condensation
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Renowacja kolektora wody chłodzącej w elektrowni Konin
Renovation of a cooling water collector at Konin power plant
Autorzy:
Abel, T.
Powiązania:
https://bibliotekanauki.pl/articles/163621.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
Elektrownia Konin
kolektor wody chłodzącej
remont
technologia
MAXI-LINING
KANREM
Konin power plant
cooling water collector
renovation
technology
Opis:
W pracy przedstawiono projekt oraz etapy realizacji renowacji rurociągu zlokalizowanego na terenie Elektrowni Konin. W projekcie tym wykorzystano bezwykopowe technologie renowacji rurociągów wielkowymiarowych.
This article describes the design and stages of construction of a pipeline on the site of the Konin power plant. The project involved the use of trenchless technologies for the renovation of large pipelines.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 112-115
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water management at CCGT unit
Optymalizacja gospodarki wodą w bloku gazowo-parowym
Autorzy:
Szaban, J.
Wawrzyński, I.
Powiązania:
https://bibliotekanauki.pl/articles/276594.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optymalizacja
Ovation
SmartProcess
chłodnia wentylatorowa
Cykl Kombinowany w Wysokosprawnej Kogeneracji
optimization
power plant
cooling towers
Combined Cycle Gas Turbine
Opis:
This paper discusses a water management optimization of cooling towers. Description of a problem solution as well as its industrial application is included. The used software belongs to Emerson's SmartProcess products. It has been applied to two power plants as a part of the Ovation DCS (distributed control system).
W artykule omówiono optymalizacje gospodarki wodnej w chłodni wentylatorowej. Podano opis rozwiązania problemem jak również jego zastosowania w przemyśle. Zastosowano część oprogramowania z pakietu SmartProcess dostarczanego przez Emerson. Pakiet użyto w dwóch elektrowniach, jako uzupełnienie rozproszonego systemu sterowania Ovation.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 250-253
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection and calculation of air cooling solutions in underground coal mines in Vietnam
Dobór i obliczenia rozwiązań chłodzenia powietrza w podziemnych kopalniach węgla w Wietnamie
Autorzy:
Borowski, Marek
Trung Tien, Quan
Łuczak, Rafał
Życzkowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1841452.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
air temperature
air humidity
air cooling
thermal power of cooler
temperatura powietrza
wilgotność powietrza
chłodzenie powietrza
moc cieplna chłodnicy
Opis:
Currently, Vietnamese underground mines have been exploited down to -500 m and, in the near future, they will be exploited deeper. The exploitation of coal of seams has an negative impact on a workers environment. The increase in the depth of coal seam exploitation causes is the increase of adverse microclimate factors such as temperature, moisture, heat radiation. According to the current Viet¬namese laws, coal deposits can be mined in a condition when air temperature does not exceed 30oC, although this rule is not always observed, especially during summer. The article show how reducing the adverse impact of climate factors in the mines and calculating the parameters which reduce the temperature on an example in one of underground coal mines in Vietnam.
Obecnie wietnamskie kopalnie podziemne zostały wyeksploatowane do -500 m, w najbliższej przyszłości będą eksploatowane głębiej. Eks¬ploatacja ma negatywny wpływ na środowisko. Działalność eksploatacji w wyrobiskach powoduje wzrost niekorzystnych czynników mi-kroklimatycznych, takich jak temperatura, wilgotność, promieniowanie cieplne. Zgodnie z obowiązującym wietnamskim prawem, złoża węgla mogą być eksploatowane w warunkach, gdy temperatura powietrza nie przekracza 30°C, chociaż nie zawsze jest to przestrzegane, zwłaszcza latem. W artykule przedstawiono rozwiązanie ograniczania niekorzystnego wpływu czynników klimatycznych w kopalniach oraz obliczenie parametrów obniżających temperaturę powietrza na przykładzie podziemnych kopalń węgla w Wietnamie.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 237-244
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological and biomechanical principles of the controlling molluscs Melanoides tuberculata (Müller 1774) and Tarebia granifera (Lamarck, 1822) in reservoirs of strategic importance
Autorzy:
Oleh, Marenkov
Kyrylo, Batalov
Olena, Kriachek
Powiązania:
https://bibliotekanauki.pl/articles/1177801.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Clea helena
Melanoides tuberculata
Tarebia granifera
Zaporizhia Nuclear Power Plant
assassin snail
biological invasion
cooling pond
red-rimmed melania
thiarids
Opis:
The article presents the results of complex laboratory investigations on the biological and biomechanical ways of control of Melanoides tuberculata (Müller 1774) and Tarebia granifera (Lamarck, 1822) molluscs in simulated conditions close to the conditions of the cooling pond of the Zaporizhia Nuclear Power Plant. It was determined that molluscs have naturalized in the Zaporizhia Nuclear Power Plant cooling pond, quickly increased their number and created a threat to hydraulic structures. Taking into account biological features of Thiaridae mollusks and technical and ecological features of Zaporizhia NPP, we carried out a series of experiments using biological control measures (the use of predatory species of hydrobionts) and mechanical means for controlling mollusks. Representatives of different taxons of the Animalia Kingdom were selected as predatory species of hydrobionts, which potentially can consume gastropods: Mollusca, Crustaceans and Fish. It has been found experimentally that the use of marbled crayfish Procambarus virginalis (Lyko, 2017), pumpkinseed Lepomis gibbosus (Linnaeus, 1758) and Botia lohachata Chaudhuri, 1912 has not given positive results in the development of measures to control the number of molluscs. Positive results were obtained in a series of experiments with predatory mollusc assassin snail Clea helena (von dem Busch, 1847), but it was noted that in the presence of more accessible feeds, assassin snail Clea helena (von dem Busch, 1847) consumes smaller quantities of Thiaridae mollusks. The most successful results we obtained in experiments with traps for molluscs. We have developed experimental constructions of traps with lower and upper inlets that act as mollusk accumulator and can be installed in the coastal zone of the reservoir and Zaporizhia NPP cooling system channels for reducing the number of reproductive individuals of Melanoides tuberculata (Müller 1774) and Tarebia granifera (Lamarck, 1822). The most effective were the traps with the lower inlet to which the mollusks could get faster. In order to attract mollusks to traps, we have conducted studies on the use of feed baits for molluscs. Most effectively, molluscs fell into traps that contained lime feed, feedstock sunflower oil and anise oil. The most effective among mollusks was the bait with the addition of anise oil. During the exposure, traps with anise bait traps accumulated 14.1% of molluscs. The conducted researches can serve as the basis for the development of biomelioration measures aimed at reducing the negative impact of accidental introduction of new species of molluscs into technical reservoirs of strategic importance.
Źródło:
World Scientific News; 2018, 99; 71-83
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania podłoża i analiza numeryczna posadowienia chłodni kominowej bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II
The tests of the subsoil and numerical analysis of the foundation of cooling tower 910 MW unit power in Power plant Jaworzno III - Power plant II
Autorzy:
Biały, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2055989.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
chłodnia kominowa
chłodnia hiperboloidalna
blok energetyczny
Elektrownia Jaworzno III
podłoże gruntowe
badanie geotechniczne
wiercenie
osiadanie
posadowienie budowli
analiza numeryczna
cooling tower
hyperbolic cooling tower
power unit
subsoil
geotechnical investigation
boring
settlement
foundation
numerical analysis
Opis:
W artykule zaprezentowano wyniki analiz numerycznych osiadań hiperboloidalnej chłodni kominowej bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II. Obliczenia osiadań bazowały na wynikach sondowań statycznych CPTU i testów DMT. Grunty w symulacjach numerycznych opisano modelem Coulomba-Mohra.
The paper presents the results of numerical analysis settlements of hyperbolic cooling tower of the 910 MW power unit in the Power plant Jaworzno III – Power plant II. The calculation of the settlements based on results of CPTU and DMT tests. The grounds in the numerical simulations were described using the Coulomb-Mohr model.
Źródło:
Przegląd Budowlany; 2021, 92, 9; 10--14
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognoza temperatury i wilgotności powietrza na wylocie parownika chłodziarki bezpośredniego działania
An air-temperature and air-humidity prognosis at an evaporator inlet of a direct-action refrigerator
Autorzy:
Nowak, B.
Łuczak, R.
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/165689.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
prognoza temperatury i wilgotności powietrza
chłodzenie powietrza
moc cieplna chłodnicy
air-temperature and air-humidity prognosis
air cooling
thermal power of cooler
Opis:
W artykule podano sposób określenia temperatury i wilgotności właściwej powietrza opuszczającego parownik chłodziarki bezpośredniego działania typu TS-300, pracującej w konkretnych warunkach cieplno-wilgotnościowych. W tym celu wykorzystano dane techniczne współpracującego z taką chłodnicą wentylatora lutniowego oraz równania modeli matematycznych opisujących pracę rozważanego systemu (Łuczak 2012, Nowak, Łuczak 2015, Nowak i in. 2016) i proces chłodzenia powietrza w parowniku (Filek, Nowak 1994). Uzyskane z rozwiązań przyjętych opisów matematycznych wyniki obliczeń numerycznych porównano z rezultatami pomiarów i określono istotność statystyczną uzyskanych odchyłek, oceniając tym samym praktyczną przydatność przyjętego modelu do oceny skuteczności pracy chłodziarki powietrza TS-300.
This paper presents methods of determination of temperature and specific humidity of air, leaving the direct-action refrigerator’s evaporator (TS-300) working in the particular hot-humidity conditions. For this, technical data of fan co-working with that cooler, mathematical equations describing operation of this system (Łuczak 2012, Nowak, Łuczak 2015, Nowak et al. 2016) as well as air-cooled process in the evaporator were used (Filek, Nowak 1994). The results obtained from mathematical equations were compared with the measured results and statistical significance of deviations were defined. For this reason, practical usability of the model for evaluation of the work effectiveness of the air refrigerator was examined.
Źródło:
Przegląd Górniczy; 2017, 73, 4; 56-61
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja redukcji hałasu chłodnic wentylatorowych
The concept of noise reduction of cooling fans
Autorzy:
Zając, J.
Włodarz, R.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153871.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
chłodnica wentylatorowa
hałas
skorygowany poziom ciśnienia akustycznego
transformator elektroenergetyczny
ograniczanie hałasu
cooling fan
noise
corrected sound pressure level
power transformer
noise reduction
Opis:
Tematyka artykułu dotyczy prowadzonych przez firmę Energo-Silesia i pracowników Politechniki Opolskiej badań i prac koncepcyjnych zmierzających do zaprojektowania oraz skonstruowania nowoczesnej, niskoszumnej chłodnicy wentylatorowej. Celem omawianych w artykule badań jest próba optymalizacji aktualnie stosowanych w przemyśle konstrukcji olejowo-powietrznych układów chłodzących transformatorów pod kątem możliwość redukcji generowanego przez nie hałasu. W pracy zaproponowano trzy sposoby redukcji poziomu ciśnienia akustycznego poprzez: zmianę kształtu dyfuzora wylotu powietrza, zastosowanie cichobieżnych wentylatorów i regulacji prędkości obrotowej wentylatorów.
During the operation a power transformer produces noise whose main sources are, among others, cooling fans and magnetostrictive vibrations of the core [1, 2]. A power transformer installed in an industrial object should be chosen in such a way that the noise arising during its normal operation does not exceed the limit values set out in particular in environmental standards [3, 4]. The paper presents the scope of research and conceptual work conducted by the staff of the Energo-Silesia company and Opole University of Technology. It is aimed at design and construction of a modern, low-noise cooling fan. The main objective of the work is an attempt to optimise the methods used in construction industry of oil-air cooling systems of power transformers as well as to assess constraints generated by the environmental sound pressure level. There are proposed three potential areas for possible reduction of noise produced in coolers. The first is optimisation of a structure housing the column and use of steering cooler air stream (Fig. 1b). The second option is to use a specialised fan blade design, and consequently a reduced power level (Figs. 2 and 4). The last and most widely described in publications is the concept of intelligent speed control of fan motors (Figs. 8 and 9).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 338-342
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania podłoża i analiza numeryczna posadowienia chłodni kominowej bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II
The tests of the subsoil and numerical analysis of the foundation of cooling tower 910 mw unit power in Power plant Jaworzno III - Power plant II
Autorzy:
Biały, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/2055974.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
chłodnia kominowa
chłodnia hiperboloidalna
blok energetyczny
Elektrownia Jaworzno III
podłoże gruntowe
badanie geotechniczne
wiercenie
osiadanie
posadowienie budowli
analiza numeryczna
cooling tower
hyperbolic cooling tower
power unit
subsoil
geotechnical investigation
boring
settlement
foundation
numerical analysis
Opis:
W artykule zaprezentowano wyniki analiz numerycznych osiadań hiperboloidalnej chłodni kominowej bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II. Obliczenia osiadań bazowały na wynikach sondowań statycznych CPTU i testów DMT. Grunty w symulacjach numerycznych opisano modelem Coulomba-Mohra.
The paper presents the results of numerical analysis settlements of hyperbolic cooling tower of the 910 MW power unit in the Power plant Jaworzno III – Power plant II. The calculation of the settlements based on results of CPTU and DMT tests. The grounds in the numerical simulations were described using the Coulomb-Mohr model.
Źródło:
Przegląd Budowlany; 2021, 92, 9; 10--14
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Moc cieplna wymienników górniczej sprężarkowej chłodziarki powietrza
Thermal power of exchangers in mine compression refrigerator of air
Autorzy:
Nowak, B.
Filek, K.
Powiązania:
https://bibliotekanauki.pl/articles/350086.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc wymienników ciepła
air conditioning of mine
air cooling
compression refrigerator
thermal power of heat exchanger
Opis:
Artykuł dotyczy górniczej sprężarkowej chłodziarki powietrza. Rozważono jej pracę zarówno z wewnętrznym regeneracyjnym wymiennikiem ciepła (dochładzaczem), jak i bez tego wymiennika. Podano równania, z których wyznaczyć można moce cieplne parownika, skraplacza i dochładzacza chłodziarki. Założono skupiony charakter wszystkich elementów chłodziarki (oprócz wymienionych, także sprężarki i zaworu rozprężnego). W przypadku chłodziarki z dochładzaczem otrzymano układ złożony z 12 równań algebraicznych, w którym niewiadomymi, oprócz mocy cieplnych trzech wspomnianych wymienników, są temperatura i wilgotność powietrza schłodzonego, temperatura wody za skraplaczem i temperatura czynnika chłodniczego w pięciu charakterystycznych punktach jego obiegu oraz stopień suchości czynnika na wlocie parownika. W przypadku chłodziarki bez dochładzacza układ składa się z dziewięciu równań o tych samych, co poprzednio, niewiadomych, z wyjątkiem trzech dotyczących dochładzacza.
This article applies to mine compression refrigerator of air. In this article, work of refrigerator with or without inner regenerative heat exchanger (subcooler) is considered. The equations are given, from which thermal powers of evaporator, condenser and subcooler of refrigerator are determined. Focused character of all elements of refrigerator is assumed (expect specified, compressor and expansion valve also). For refrigerator with subcooler, system compound with 12 algebraic equations is received, in which unknowns are: temperature and humidity of cooled air, temperature of water after the condenser and temperature of refrigerant in five characteristic points of its circulation and ariolity degree of refrigerant of evaporator's inlet. For refrigerator without subcooler, the system is composed of 9 equations with the same as before unknowns, with the exception of 3 equations refer to subcooler.
Źródło:
Górnictwo i Geoinżynieria; 2009, 33, 3; 79-91
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalne określenie wpływu doboru czynnika chłodniczego na moc cieplną chłodziarki sprężarkowej
Experimental determination of influence of refrigerant selection on thermal power of compression refrigerator
Autorzy:
Filek, K.
Nowak, B.
Powiązania:
https://bibliotekanauki.pl/articles/350309.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
ekologiczne czynniki chłodnicze
klimatyzacja kopalń
chłodzenie powietrza
moc parownika chłodziarki sprężarkowej
ecological refrigerants
mine air conditioning
cooling system
power of compression refrigerator
Opis:
W artykule przedstawiono zagadnienie skuteczności schładzania powietrza górniczą chłodziarką sprężarkową, określając eksperymentalnie moc cieplną jej parownika przyjętą jako kryterium jakości chłodzenia. Pomiary przeprowadzono na stanowisku badawczym dla pracy chłodziarki z trzema różnymi proekologicznymi czynnikami chłodniczymi - R404A, R407C i R507. W tym celu dokonano pomiarów temperatury i wilgotności powietrza przed i po schłodzeniu oraz natężenia jego przepływu przez parownik. W sumie zbadano chłodzenie powietrza w 108 różnych wariantach - po 36 dla każdego z wymienionych czynników chłodniczych. Poszczególne warianty badań różnią się warunkami wejściowymi - stanem poddanego chłodzeniu powietrza i natężeniem jego przepływu. Wykonując pomiary dla różnych czynników chłodniczych, utrzymywano możliwie jednakowe warunki wejściowe w odpowiadających sobie wariantach. Temperaturę powietrza przed parownikiem utrzymywano na trzech poziomach, jego wilgotność względną również na trzech poziomach, natomiast wydatek przepływu powietrza na czterech poziomach. Rezultaty badań w postaci, wyliczanej każdorazowo na podstawie pomiarów, mocy cieplnej parownika przedstawiono w tabeli i na wykresach, oddzielnie dla poszczególnych wydatków przepływu. Uzyskane wyniki badań pozwoliły ocenić jakość chłodzenia powietrza badaną chłodziarką w zależności od wykorzystywanego w niej czynnika chłodniczego.
In this article a problem of air-cooling efficiency by using mine compression refrigerator is presented. Experimentally, a thermal power of evaporator was defined, as figure of cooling merit. Measurements were carried out on test stand for refrigerator work with three different pro-ecological refrigerants - R404A, R407C and R507. For that purpose, it was achieved the measurements of temperature and humidity of air before and after cooling, and rate of air flow through evaporator. In amount, cooling of air in 108 different variants were studied - 36 for each mentioned refrigerant. Particular variants of studies were differed in input conditions - state of cooling air and rate of air flow. Making measurements for different refrigerants were kept up equal input conditions in suited variants. Temperature of air before evaporator was kept up on three levels, its relative humidity - on three levels, too, efficiency of flow - on four levels. Results of those studies in form of thermal power of evaporator, which was enumerated on the basis of measurements, are presented in table, whereas on charts are shown separately results for each flow efficiency. Obtained results of studies allowed to estimate a quality of air cooling by refrigerator in dependence on using refrigerant.
Źródło:
Górnictwo i Geoinżynieria; 2006, 30, 2; 9-18
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies