Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zero-valent iron" wg kryterium: Temat


Tytuł:
Efficiency of Pb(II) and Mo(VI) removal by kaolinite impregnated with zero-valent iron particles
Autorzy:
Rybka, Karolina
Suwała, Katarzyna
Maziarz, Paulina
Matusik, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/127609.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
zero-valent iron particles
kaolinite
adsorption
Pb(II)
Mo(VI)
Opis:
In this work, kaolinite modified with zero-valent iron was synthesized and used as a sorbent for Pb(II) and Mo(VI) removal from aqueous solutions. The obtained material was characterized by X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. The methods revealed successful modification by the Fe0 particles precipitation on the surface of well-ordered kaolinite. The sorption experiment results showed a significant increase of sorption capacity in relation to the raw kaolinite. The kaolinite with 25% content of Fe0 was found to be the best material for Pb(II) and Mo(VI) removal, resulting in approximately 500 mmol•kg-1 and 350 mmol•kg-1 sorption, respectively. The possible mechanisms responsible for metals’ removal were identified as reduction by Fe0 ‘core’ and adsorption on the iron hydroxides ‘shell’. The study indicated that the obtained material is capable of efficient Pb(II) and Mo(VI) removal and may be an interesting alternative to other methods used for heavy metals’ removal.
Źródło:
Mineralogia; 2017, 48, 1/4; 71-86
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactivity of nano zero-valent iron in permeable reactive barriers
Autorzy:
Pawluk, K.
Fronczyk, J.
Garbulewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/779492.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
contaminated groundwater
permeable reactive barrier
nano zero-valent iron
reactivity
Opis:
In this paper, the ability of nZVI to remove heavy metals (Cd, Cu, Ni, Pb, Zn) from multicomponent aqueous solutions was investigated through batch experiments. The experimental data were fitted to a second-order kinetic model based on solid capacity. The data for copper and lead fitted well into the second-order kinetic model, thus suggesting that the adsorption had a physical character. The values of the removal ratio and the second-order rate constant indicated that the order of adsorption priority of nZVI was as follows: Pb>Cu>Zn>Cd>Ni. The adsorption isotherm data were described by the most conventional models (Henry, Freundlich, and Langmuir). Equilibrium tests showed that copper and zinc were removed from the solution by adsorption processes, i.e., complexation and competitive adsorption. The test results suggested that the removal processes using nZVI are more kinetic than equilibrium. The study demonstrated that nZVI is favorable reactive material; however, comprehensive investigation should be performed for further in situ applications in PRB technology.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 1; 7-10
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Desalination of groundwater and impoundments using Nano-Zero Valent Iron, n-Fe°
Autorzy:
Antia, D.D.J.
Powiązania:
https://bibliotekanauki.pl/articles/108538.pdf
Data publikacji:
2015
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
desalination
zero-valent iron
ZVI
diffusion
saline aquifers
saline impoundments
Opis:
Salinization of groundwater is a major problem, particularly in areas with limited infrastructure. 14 diffusion reactors are operated diabatically at -8°C to 20°C to determine the amount of NaCl removed by n-Fe°. The reactors establish NaCl removal by Fe°: (i) 44,000-77,000 nm particle size (PS) = 0.0675-0.1925 g L-1 [feed water (FW) = 0.89 g L-1]; (ii) 50 nm PS = 0.953-1.14 g L-1 [FW = 1.095-1.19 g L-1]; (iii) 50 nm PS under nitrogen saturation (0.1-0.2 MPa) = 9.693 g L-1 [FW = 10 g L-1]; (iv) <0.01 g 50 nm PS L-1 under nitrogen saturation (0.1-0.2 MPa) = 1.564 g L-1 [FW = 4 g L-1]; (v) 50 nm PS modified by nitrogen saturation (PSN) = 5.52 g L-1 [FW = 6.89 g L-1]. Desalination commences at a time, t, after the n-Fe° is added to the water, and continues with an exponential decline until a base (equilibrium) salinity is reached. The effectiveness of n-Fe° as a desalination agent appears to increase with increased water salinity. Placement of PSN in an existing impoundment, or aquifer, may provide a cost effective, zero energy, partial desalination solution, which can be used to support emergency relief, agriculture and extractive industries.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2015, 3, 1; 21-38
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Species formed on iron surface during removal of copper ions from aqueous solutions
Autorzy:
Suponik, T.
Winiarski, A.
Szade, J.
Powiązania:
https://bibliotekanauki.pl/articles/110906.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water
zero-valent iron
copper
X-ray photoelectron spectroscopy
diffraction
Opis:
The subject of the research covered in this paper is the removal of copper (Cu2+) cations from water at low pH (initial values of pH 3 and 6) by means of zero-valent iron. The chemical states and atomic concentrations of solids formed on the surface of zero-valent iron, and the type of deposited polycrystalline substances have been analyzed with the use of XPS and XRD. The type of process causing the copper removal from water at low pH, corresponding to the effect of acid mine drainage, has been identified by analyzing the changes of physicochemical parameters and specified chemicals content in water. Cu2+ was removed from water for the initial pH of 6 was much more effective than at lower pH. The formation of CuxFe3-xO4 , where x≤1, and to a lesser degree Cu2O, Cu0 and/or CuO and/or Cu2S, were the basic processes of the removal of copper at almost neutral pH of water (pH about 6), while the formation of copper in metallic form and Cu2O, as well as probably CuO, were the basic processes for lower pH (pH about 3). The adsorption of Cu2+ on the surface of shell covering square-shaped cold-rolled steel sheet cell was an additional process causing the removal of copper from water at almost neutral pH.
Źródło:
Physicochemical Problems of Mineral Processing; 2015, 51, 2; 731-743
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactivity of nZVI in the removal of Cu(II) and Zn(II) from synthetic mine drainage
Autorzy:
Suponik, Tomasz
Neculita, Carmen Mihaela
Powiązania:
https://bibliotekanauki.pl/articles/2032928.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
mining industry
nZVI
zero-valent iron
Cu(II)
Zn(II)
przemysł wydobywczy
Opis:
Adsorption properties, including isotherms and kinetics, of nano zero-valent iron (nZVI) for Cu(II) and Zn(II) removal from synthetic mine drainage were evaluated in batch tests. The influence of contact time, nZVI doses, pH, ionic strength, temperature, and concentration on nZVI adsorption properties was assessed. The removal of Cu(II) and Zn(II) increased with pH from 3 to 7 and then stabilized up to pH 10. Moreover, the increased Cu(II) adsorption capacity upon increasing temperature and a positive enthalpy change (ΔH) indicate that the adsorption process is endothermic. The results also showed that the adsorption equilibrium for Cu(II) and Zn(II) was achieved after 50 and 30 min, respectively. Kinetics were best described by a pseudo-nth order model, with the order of sorption of 2.231 and 1.363, and the rate constants of 0.0008 and 0.0679 mg1-n·gn-1/min, for Cu(II) and Zn(II), respectively. The correlation between the amount of metals adsorbed on nZVI surface and the residual amount of metals in water during isothermal tests was best described by the nonlinear Sips model. Using this model, high q maxS were found: 286.6 mg/g and 142.6 mg/g, for Cu(II) and Zn(II), respectively, as indication of their high sorption capacity.
Źródło:
Environment Protection Engineering; 2021, 47, 2; 93-108
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of nanoscale zero-valent iron doped carbonized zeolitic imidazolate framework-8 for methylene blue removal in water
Autorzy:
Chen, Shuai
Qiao, Lemeng
Feng, Xuejiao
Huang, Yufu
Gao, Guilan
Guan, Jie
Lin, Donghai
Powiązania:
https://bibliotekanauki.pl/articles/2204144.pdf
Data publikacji:
2023
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Nanoscale zero-valent iron
Carbonized zeolitic imidazolate framework-8
Mesoporous carbon
Methylene blue
Opis:
Nanoscale zero-valent iron-doped carbonized zeolitic imidazolate framework-8 (nZVI/CZIF-8) was prepared by carbonation of ferric nitrate and ZIF-8 at 800 °C and used as an adsorbent to remove methylene blue (MB) from water. The synthesized nZVI/CZIF-8 has a specific surface area of 806.9 m2/g, a pore volume of 0.86 cm3/g and an nZVI content of 1.35%, respectively. Both the nZVI/CZIF-8 and CZIF-8 have identical functional groups of O-H, C-H and C=C. With the increase of CZIF-8 size, MB removal rate increased. The doping of nZVI increased the MB removal percentage from 74.5% for ZIF-8 to 96.2% within 80 min for nZVI/CZIF-8. The MB removal percentage increased with the dosage of nZVI/CZIF-8. The MB adsorption with the adsorbents conforms to the Freundlich adsorption isothermal model and the removal rate fitted well to a pseudo-first-order model. The results demonstrate the feasibility of synthesizing high active and stable nZVI/CZIF-8 particles.
Źródło:
Polish Journal of Chemical Technology; 2023, 25, 1; 12--19
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of 4-chlorophenol from aqueous solution by granular activated carbon/nanoscale zero valent iron based on Response Surface Modeling
Autorzy:
Majlesi, M.
Hashempour, Y.
Powiązania:
https://bibliotekanauki.pl/articles/205422.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
response surface methodology
4-chlorophenol
NZVI/AC
activated carbon
nano zero-valent iron
Opis:
The phenolic compounds are known as priority pollutants, even in low concentrations, as a result of their toxicity and non-biodegradability. For this reason, strict standards have been established for them. In addition, chlorophenols are placed in the 38th to 43th in highest priority order of toxic pollutants. As a consequence, contaminated water or wastewaters with phenolic compounds have to be treated before discharging into the receiving water. In this study, Response Surface Methodology (RSM) has been used in order to optimize the effect of main operational variables responsible for the higher 4-chlorophenol removal by Activated Carbon-Supported Nanoscale Zero Valent Iron (AC/NZVI). A Box-Behnken factorial Design (BBD) with three levels was applied to optimize the initial concentration, time, pH, and adsorbent dose. The characterization of adsorbents was conducted by using SEM-EDS and XRD analyses. Furthermore, the adsorption isotherm and kinetics of 4-chlorophenol on AC and AC/NZVI under various conditions were studied. The model anticipated 100% removal efficiency for AC/NZVI at the optimum concentration (5.48 mg 4-chlorophenol/L), pH (5.44), contact time (44.7 min) and dose (0.65g/L). Analysis of the response surface quadratic model signified that the experiments are accurate and the model is highly significant. Moreover, the synthetic adsorbent is highly efficient in removing of 4-chlorophenol.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 13-25
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of heavy metals from groundwater affected by acid mine drainage
Autorzy:
Suponik, T.
Blanco, M.
Powiązania:
https://bibliotekanauki.pl/articles/110087.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
coal mine waste dumps
acid mine drainage
groundwater
PRB technology
metals
zero-valent iron
Opis:
Batch tests have been used to assess the level of the removal of metals (copper, nickel, cobalt, zinc, and chromium, in cationic and in anionic forms) from water at low pH values affected by acid mine drainage. The predominant processes which result in the removal with the use of zero-valent iron (Fe0) in Permeable Reactive Barrier Technology were evaluated. The most probable processes for each metal have been presented in drawings. There are: reductive precipitation leading to the metallic form, co-precipitation mainly with iron in the form of oxides and/or hydroxides and adsorption on the surface of iron corrosion products or on the surface of zero-valent iron.
Źródło:
Physicochemical Problems of Mineral Processing; 2014, 50, 1; 359-372
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Spontaneous Oxidation Processes of Zero-valent Iron and Electrocoagulation for Reactive Black 5 Removal
Zastosowanie procesów samorzutnego utleniania żelaza na zerowym stopniu utlenienia (ZVI) oraz elektrokoagulacji (EC) w usuwaniu Reactive Black 5
Autorzy:
Wysocka, I.
Filipkowska, U.
Jóźwiak, T.
Powiązania:
https://bibliotekanauki.pl/articles/233177.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
dye removal
zero-valent iron
electrocoagulation
reactive dyes
usuwanie barwników
utlenianie żelaza
elektrokoagulacja
barwniki reaktywne
Opis:
Two methods of Reactive Black 5 dye removal were compared in this work, namely electrocoagulation (EC) and one based on spontaneous electrochemical oxidation of zero-valent iron (ZVI). Both methods are based on electrode processes and the sorption process and allow to achieve a similar effectiveness of dye removal. In the case of ZVI, however, a longer contact time or a greater surface area of the electrodes applied is necessary. In turn, the ZVI enables to conduct the processes of dye removal with no requirement for an external source of electric current (lower exploitation inputs). The study demonstrated that the application of both the ZVI method and EC is especially advisable in the case of lower initial concentrations of dye in the solution, i.e. the higher the concentration, the lower the contribution of electrode processes in dye removal from the solution and the greater the contribution of sorption processes.
W ramach niniejszej pracy porównano dwie metody usuwania barwnika Reactive Black 5. Metodę elektrokoagulacji (EC), oraz metodę opartą na samorzutnym elektrochemicznym utlenianiu żelaza na 0 stopniu utlenienia (ZVI). Obie metody wykorzystują procesy elektrodowe oraz procesy sorpcji, umożliwiając uzyskanie podobnej efektywność usuwania barwnika. W przypadku ZVI wymagany jest jednak dłuższy czas kontaktu, lub większa powierzchnia zastosowanych elektrod. ZVI umożliwia jednak przeprowadzenie procesów usuwania barwy, bez konieczności stosowania zewnętrznego źródła prądu (mniejsze nakłady eksploatacyjne). Badania wykazały, że zastosowanie zarówno metody ZVI i EC ma szczególne uzasadnienie w przypadku niższych stężeń początkowych barwnika w roztworze. Im wyższe stężenie, tym udział procesów elektrodowych w usuwaniu barwy roztworu jest mniejszy a przewagę zyskują procesy sorpcji.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 4 (124); 121-128
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automotive fleet repair facility wastewater treatment using air/ZVI and air/ZVI/H2O2 processes
Oczyszczanie ścieków z zakładów naprawczych floty samochodowej z wykorzystaniem procesów powietrze/ZVI i powietrze/ZVI/H2O2
Autorzy:
Bogacki, J. P.
Al-Hazmi, H.
Powiązania:
https://bibliotekanauki.pl/articles/205311.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
zero-valent iron
advanced oxidation processes
AOP
ZVI
oczyszczanie ścieków
żelazo metaliczne
zaawansowane procesy utleniania
Opis:
Advanced automotive fleet repair facility wastewater treatment was investigated with Zero-Valent Iron/Hydrogen Peroxide (Air/ZVI/H2O2) process for different process parameters: ZVI and H2O2 doses, time, pH. The highest Chemical Oxygen Demand (COD) removal efficiency, 76%, was achieved for ZVI/H2O2 doses 4000/1900 mg/L, 120 min process time, pH 3.0. COD decreased from 933 to 227 mg/L. In optimal process conditions odor and color were also completely removed. COD removal efficiency was increasing with ZVI dose. Change pH value below and over 3.0 causes a rapid decrease in the treatment effectiveness. The Air/ZVI/H2O2 process kinetics can be described as d[COD]/dt = -a [COD]tm, where ‘t’ corresponds with time and ‘a’ and ‘m’ are constants that depend on the initial reagent concentrations. H2O2 influence on process effect was assessed. COD removal could be up to 40% (560 mg/L) for Air/ZVI process. The FeCl3 coagulation effect was also evaluated. The best coagulation results were obtained for 700 mg/L Fe3+ dose, that was slightly higher than dissolved Fe used in ZVI/H2O2 process. COD was decreased to 509 mg/L.
Ścieki z zakładu naprawczego floty samochodowej poddano oczyszczaniu z wykorzystaniem żelaza metalicznego i nadtlenku wodoru (Air/ZVI/H2O2). Badano wpływ dawki żelaza i nadtlenku wodoru, czasu i pH na efektywność procesu. Największy stopień usunięcia ChZT, 76%, uzyskano dla dawek ZVI/H2O2 4000/1900 mg/L, czasu 120 min i pH 3.0. ChZT zmniejszono z 933 do 227 mg/L. Dodatkowo uzyskano całkowite usunięcie barwy i zapachu. Skuteczność usunięcia ChZT rosła wraz ze wzrostem zastosowanej dawki ZVI. Zmiana pH na inne niż 3, powoduje gwałtowne zmniejszenie efektywności procesu. Kinetyka procesu może zostać opisana z wykorzystaniem równania d[COD]/dt = -a [COD]tm, gdzie ‘t’ oznacza czas a ‘a’ i ‘m’ są stałymi zależnymi od początkowego stężenia reagentów. Badano także wpływ H2O2 na efektywność procesu. Skuteczność usunięcia ChZT wynosi 40% (560 mg/L) w przypadku zastosowania ZVI bez dodatku H2O2. Określono także skuteczność koagulacji z wykorzystaniem FeCl3. Najlepsze rezultaty uzyskano dla dawki Fe3+ 700 mg/L, zmniejszając ChZT do 509 mg/L.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 24-31
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the effect of reactive materials on the content of selected elements in Indian mustard grown in Cu-contaminated soils
Ocena wpływu materiałów reaktywnych na zawartość wybranych pierwiastków w gorczycy sarepskiej uprawianej na glebie zanieczyszczonej miedzią
Autorzy:
Radziemska, M.
Jeznach, J
Mazur, Z.
Fronczyk, J.
Bilgin, A.
Powiązania:
https://bibliotekanauki.pl/articles/947316.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Indian mustard
lignite
soil contamination
zero-valent iron (ZVI)
gorczyca sarepska
węgiel brunatny
zanieczyszczenie gleby
żelazo elementarne
Opis:
Zero-valent iron (ZVI) represent a promising agent for environmental remediation. The research was aimed to determine the influence of copper in doses of 0, 80, 150, 300, and 600 mg Cu·kg–1 of soil as well as ZVI, and lignite additives on the content of macroelements in the Indian mustard (Brassica juncea (L.) Czern.). The average accumulation of analyzing elements in Indian mustard grown in copper contaminated soil were found to follow the decreasing order Mg > Na > P > Ca > K > N. Soil contamination at 600 mg Cu·kg–1 of soil led to the highest increase in P, Mg, N, and Ca content. The application of ZVI had a positive influence on the average phosphorus and potassium content of Indian mustard. Moreover, the application of ZVI and lignite had a positive influence on the average Mg and Ca content in the above-ground parts of Indian mustard. From the analyzed reactive materials, the application of lignite was shown to be the most effective resulting in the decrease in the average nitrogen and calcium content when compared to the control crop. Calcium content in plants from the control group, without the addition of zero-valent iron, and powered lignite (control), was positively correlated with increasing doses of copper.
Zakres badań obejmował określenie wpływu zanieczyszczenia gleby miedzią (0, 80, 150, 300 i 600 mg Cu·kg–1) oraz dodatku żelaza elementarnego (ZVI) i węgla brunatnego na zawartość wybranych makroelementów w gorczycy sarepskiej (Brassica juncea (L.) Czern.). Średnia zawartość analizowanych makroskładników w gorczycy rosnącej na glebie zanieczyszczonej miedzią kształtowała się następująco: Mg > Na > P > Ca > K > N. Gleba zanieczyszczona w dawce 600 mg Cu·kg–1 spowodowała zwiększenie zawartości P, Mg, N i Ca. Dodatek żelaza elementarnego (ZVI) wywarł pozytywny wpływ na średnią zawartość fosforu i potasu w Brassica juncea. Ponadto ZVI i węgiel brunatny wpływały pozytywnie na średnią zawartość Mg i Ca w częściach nadziemnych analizowanej rośliny. Spośród dodawanych do gleby analizowanych materiałów reaktywnych węgiel brunatny spowodował największy wzrost zawartości azotu i wapnia w częściach nadziemnych analizowanej rośliny. Zawartość wapnia w roślinach rosnących w grupie kontrolnej (bez dodatku żelaza elementarnego i węgla brunatnego) była dodatnio skorelowana ze wrastającym zanieczyszczeniem gleby miedzią.
Źródło:
Journal of Water and Land Development; 2016, 28; 53-60
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3-aminopropyltriethoxysilane functionalized nanoscale zero-valent iron for the removal of dyes from aqueous solution
Autorzy:
Zhang, J.
Liu, Q.
Ding, Y.
Bei, Y.
Powiązania:
https://bibliotekanauki.pl/articles/779270.pdf
Data publikacji:
2011
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
3-aminopropylotrietoksysilan
żelazo zerowartościowe
separacja magnetyczna
3-aminopropyltriethoxysilane
nano zero-valent iron
acid brilliant scarlet GR
reactive brilliant red K-2BP
magnetic separation
Opis:
Batch studies were conducted to investigate the potential of 3-aminopropyltriethoxysilane modified nano zero-valent iron (APS-NZVI) to adsorb two dyes (acid brilliant scarlet GR and reactive brilliant red K-2BP) from aqueous solution. APS-NZVI showed good adsorption performance for two dyes. Under the adsorption conditions of pH 4.5, initial concentration was 100 mg/L, and time=4h, the maximum adsorption capacities of APS-NZVI were 121.06 mg/g for acid brilliant scarlet GR and 191.5 mg/g for reactive brilliant red K-2BP, respectively. The results revealed that the adsorption behavior of the dyes on the nano-particles fitted well with the Langmuir model and the sorption kinetics fits well the pseudo-second-order rate equation.
Źródło:
Polish Journal of Chemical Technology; 2011, 13, 2; 35-39
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic-assisted synthesis of reactive carboxymethyl cellulose stabilized nano zero-valent iron and its application for removal of Cr6+ and Cu2+ ions
Autorzy:
Ayob, A.
Santiagoo, R.
Amneera, W. A.
Ismail, N.
Abdullah, A. Z.
Powiązania:
https://bibliotekanauki.pl/articles/207403.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
high resolution transmission
electron microscopy
light scattering
transmission electron microscopy X ray diffraction
zero-valent iron
wysoka rozdzielczość transmisyjna
mikroskopia elektronowa
dyfrakcja rentgenowska
żelazo
Opis:
Carboxymethyl cellulose (CMC) was used in the chemical reduction using sodium borohydride to yield dispersive nano zero-valent iron (nZVI) particles as reactive and stable adsorbents. CMC- -stabilized nZVI particles were characterized via UV-visible light spectroscopy, X-ray diffraction, dynamic light scattering, transmission electron microscopy, and specific surface area assisted using a probe ultrasonication dispersing tool at 50% amplitude power. High catalytic reactivity obtained in pseudo-first order reaction for Cr6+ (rate constant K1 = 0.0311 min–1) and pseudo-second order for Cu2+ (rate constant K2 = 0.0946 g·mg–1·min–1) indicated that colloidal stability of nZVI particles can be achieved with a stabilizer for the removal of toxic contaminants.
Źródło:
Environment Protection Engineering; 2016, 42, 2; 55-79
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Azo Dye Acid Red 27 from Aqueous Solutions Using Classical and Modified Fenton Reagent with Zero-Valent Iron
Usuwanie barwnika azowego czerwień kwasowa 27 z roztworów wodnych przy zastosowaniu odczynnika Fentona modyfikowanego żelazem zero wartościowym
Autorzy:
Kliś, Simona
Thomas, Maciej
Barbusiński, Krzysztof
Gołombek, Klaudiusz
Krzemiński, Łukasz
Chyc, Marek
Powiązania:
https://bibliotekanauki.pl/articles/234298.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
Acid Red 27
Fenton reagent
modified Fenton reagent
zero-valent iron
wastewater treatment
czerwień kwasowa 27
odczynnik Fentona
zmodyfikowany odczynnik Fentona
żelazo o zerowej wartościowości
oczyszczanie ścieków
Opis:
The article compares the classic Fenton reagent (Fe2+/H2O2) with its modification with zero-valent iron (ZVI/ H2O2) to remove azo dye Acid Red 27 from aqueous solutions at a concentration of 100 mg/L. For both methods, the most favorable parameter values were determined at which visual discoloration of the solutions tested was obtained (for Fe2+/ H2O2:pH 3.5, H2O2=60 mg/L, Fe2+/ H2O2=0.3, t=15 min, and for ZVI/ H2O2pH = 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min). Under these conditions, the COD value was reduced by 71.5% and 69.2% for the classic Fenton and its modification, respectively. A reduction in toxicity was also obtained for Vibrio fischeri bacteria to below 25% by using the Microtox test. ZVI digestion at acidic pH for 10 minutes allowed to shorten the reaction time by about four times - from 15 to 4 minutes. BET analysis showed that the specific surface area increases with the digestion time, which significantly accelerates the reaction. The visual discoloration of aqueous solutions was obtained, and the final COD values were very small, ranging from 49-53 mg O2/L. According to the Aliivibrio fischeri toxicity classification test for water samples, all solutions of dyes tested can be considered as non-toxic (toxicity value <25%). In the study presented, results of decreasing the COD value and concentration of the dye in the ZVI/ H2O2 method obtained are slightly worse compared to the Fe2+/ H2O2method. However, taking the decolorisation time as a criterion, a four times faster decolorisation time was obtained in the ZVI/ H2O2 method, compared to the Fe2+/ H2O2 method.
W artykule porównano klasyczny odczynnik Fentona (Fe2+/H2O2) z jego modyfikacją żelazem o zerowej wartościowości (ZVI/ H2O2), w celu usunięcia barwnika azowego czerwień kwasowa 27 z wodnych roztworów, o stężeniu 100 mg/L. Dla obu metod wyznaczono najkorzystniejsze wartości parametrów, przy których uzyskano wizualne odbarwienie badanych roztworów (dla (Fe2+/H2O2): pH 3,5, H2O2=60 mg/L, Fe2+/ H2O2=0,3, t=15 min. i dla ZVI/H2O2: pH 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min. W tych warunkach wartość ChZT spadła o 71,5% i 69,2% dla klasycznego Fentona i jego modyfikacji. Zmniejszenie toksyczności uzyskano również dla bakterii Aliivibrio fischeri (poniżej 25%) przy zastosowaniu testu Microtox. Trawienie ZVI w kwasowym pH przez 10 minut pozwoliło skrócić czas reakcji około cztery razy z 15 do 4 minut. Analiza BET wykazała, że powierzchnia właściwa wzrasta wraz z czasem trawienia, co znacznie przyspiesza reakcję. Uzyskano wizualne odbarwienie roztworów wodnych, a końcowe wartości ChZT były bardzo małe i mieściły się w zakresie 49-53 mg O2/L. Zgodnie z testem klasyfikacji toksyczności wobec Vibrio fischeri dla próbek wodnych, wszystkie testowane roztwory barwników można uznać za nietoksyczne (wartość toksyczności <25%).
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 5 (137); 100-106
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie odczynnika Fentona modyfikowanego nanożelazem do rozkładu barwników azowych (AR27 i RB5) w roztworach wodnych
Application of Fenton reagent modified with nano zero-valent iron to removal of azo dyes (AR27 and RB5) from aqueous solutions
Autorzy:
Barbusiński, K.
Kliś, S.
Thomas, M.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/237608.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
barwniki
oczyszczanie ścieków
utlenianie
rozkład
odczynnik Fentona
modyfikacja reakcji Fentona
nanożelazo
dyes
Acid Red 27
Reactive Black 5
wastewater treatment
oxidation
degradation
the Fenton reagent
modified Fenton reaction
nano zero-valent iron
Opis:
Badano skuteczność rozkładu dwóch barwników azowych (Acid Red 27 – AR27 oraz Reactive Black 5 – RB5) w roztworach wodnych o stężeniu 100 mg/dm3 poddanych działaniu odczynnika Fentona modyfikowanego nanożelazem (H2O2/nFeo). W przypadku każdego barwnika określono najkorzystniejsze wartości parametrów procesu, przy których uzyskano widoczne odbarwienie roztworu (barwnik AR27: pH=3, dawka H2O2 40 mg/dm3, dawka nFeo 60 mg/dm3, czas reakcji 15 min, barwnik RB5: pH=3, dawka H2O2 50 mg/dm3, dawka nFeo 20 mg/dm3, czas reakcji 15 min). W tych warunkach zmniejszenie wartości ChZT roztworów barwników AR27 i RB5 wynosiło odpowiednio 82,6% i 86,5, a zmniejszenie ich toksyczności (mierzonej testem Microtox) – odpowiednio 100% i 92,7%. W celach porównawczych do rozkładu barwników zastosowano także klasyczny odczynnik Fentona (H2O2/Fe2+). Widoczne odbarwienie wodnego roztworu barwnika AR27 uzyskano w tym przypadku przy pH=3,5, dawce H2O2 60 mg/dm3, stosunku [Fe2+]/[H2O2]=0,3 w czasie 15 min, a barwnika RB5 pH=3,5, dawce H2O2 40 mg/dm3, stosunku [Fe2+]/[H2O2]=0,75 w czasie 15 min. Zmniejszenie wartości ChZT roztworów AR27 i RB5 wynosiło odpowiednio 71,5% i 71,8%, a zmniejszenie ich toksyczności – 100% i 84,4%. Obie zastosowane metody utleniania, poza odbarwieniem roztworów wodnych, pozwoliły na zmniejszenie wartości ChZT roztworów barwników do 21÷49 mgO2/dm3. Zgodnie z klasyfikacją toksyczności próbek wodnych, wszystkie badane roztwory barwników z klasy próbek wysokotoksycznych (toksyczność >75%), po poddaniu ich działaniu odczynnika Fentona można uznać za nietoksyczne (toksyczność <25%).
Effectiveness of two azo dyes decomposition (Acid Red 27 – AR27 and Reactive Black 5 – RB5) with the Fenton reagent modified with nanoiron (H2O2/nFeo) was studied in aqueous solutions at a concentration of 100 mg/L. For each dye, the most favorable process parameters were determined to obtain visual discoloration of tested solutions (AR27: pH = 3, H2O2 = 40 mg/L, nFeo = 60 mg/L, t = 15 min; RB5: pH = 3, H2O2 = 50 mg/L, nFeo = 20 mg/L, t = 15 min). Under these conditions, the decrease in COD values for AR27 and RB5 was 82.6% and 86.5, respectively and in toxicity (Microtox test) – 100% and 92.7%, respectively. For comparative purposes, classic Fenton reagent (H2O2/Fe2+) was also used for the dye decomposition. For AR27, the visual discoloration of the aqueous solution was obtained within 15 min at pH = 3.5, H2O2 = 60 mg/L, [Fe2+]/[H2O2]=0.3 and for RB5 – within 15 min at pH = 3.5, H2O2 = 40 mg/L, [Fe2+]/[H2O2]=0.75. The decrease in COD values for AR27 and RB5 was 71.5% and 71.8%, respectively and in toxicity – 100% and 84.4%, respectively. Both oxidation methods applied, beside visual discoloration of the aqueous solutions, allowed for the COD reduction to the level of 21–49 mgO2/L. According to the toxicity classification for water samples, all the highly toxic samples of dye solutions tested (toxicity >75%) could be considered non-toxic (toxicity <25%) after the Fenton reagent application.
Źródło:
Ochrona Środowiska; 2018, 40, 3; 35-39
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies