Control of a doubly fed induction generator at grid voltage imbalance
Autorzy:
Łuszczyk, T.
Iwański, G.
Powiązania:
https://bibliotekanauki.pl/articles/1193415.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
doubly fed induction generator
power control
torque control
unbalanced grid
Opis:
Properties and control of a doubly fed induction machine operating under unbalanced grid voltage conditions have been presented. The proposed method does not include symmetrical sequences decomposition and is realized in a rotating frame not synchronized either with the grid voltage vector or with the stator flux vector. The method uses a reference torque and the reference q component of instantaneous power for calculation of the reference stator current. Next, calculation of magnetizing current for a given unbalanced grid voltage is used to assign the reference rotor current. Due to the fact that the reference current contains both a positive and a negative sequence, a proportional-integral-resonant controller is used. The main control target is the non-oscillatory waveform of torque, whereas other separate strategies like symmetrical stator current or sinusoidal rotor current can be easily obtained by adequate filtration of the reference control signals of the stator or rotor currents, respectively. The simulation results of the 2 MW model have been presented for a doubly fed induction generator as well as the results of laboratory tests with the use of a small scale 7.5 kW machine.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 31-48
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite control set MPC of LCL-filtered grid-connected power converter operating under grid distortions
Autorzy:
Falkowski, P.
Godlewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/201460.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite control set model predictive control FCS-MPC
grid-connected converters (GCCs)
inductive-capacitive-inductive (LCL) filter
unbalanced grid
higher harmonics
Opis:
Most of the basic control methods of the grid-connected converter (GCC) are defined to work with a sine wave grid voltage. In that case if the grid voltage is distorted by higher harmonics, the grid current may be distorted too, which, in consequence, may increase the value of the THD of the grid voltage. The paper deals with an improved finite control set model predictive control (FCS-MPC) method of an LCL-filtered GCC operating under distorted grid conditions. The proposed method utilizes supplementary grid current feedback to calculate the reference converter current. The introduced signal allows to effectively improve the operation when the grid is subject to harmonic distortion. The paper shows a simulation analysis of the proposed control scheme operating with and without additional feedback under grid distortions. To validate the practical feasibility of the proposed method an algorithm was implemented on a 32-bit microcontroller STM32F7 with a floating point unit to control a 10 kW GCC. The laboratory test setup provided experimental results showing properties of the introduced control scheme.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1069-1076
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies