Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stn" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Testing the Accuracy of Determining 3D Cartesian Coordinates Using the Measuring Station S8 Trimble DR Plus ROBOTIC
Badanie dokładności określania trójwymiarowych współrzędnych kartezjańskich przy użyciu uniwersalnej stacji pomiarowej S8 Trimble DR Plus ROBOTIC
Autorzy:
Sokol, S.
Bajtala, M.
Jezko, J.
Cernota, P.
Powiązania:
https://bibliotekanauki.pl/articles/318989.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
Trimble S8
STN ISO 17123-5
testing
stability of parameters
testowanie
stabilność parametrów
Opis:
Prerequisite for responsible implementation of geodetic activities and to obtain reliable results is to work with the device for which it is possible to say with certainty that it meets the required accuracy specified for the selected type of work. For this purpose it is possible to carry out the testing of the device, both in the terms of a set of norms ISO 17123, or application of other test methods and procedures. In the present paper there are results of testing of the stability of robot universal measuring station (RUMS) S8 Trimble DR Plus ROBOTIC published, which is in scientific research and teaching activities in the Department of Geodesy (KG)STU in Bratislava used.
Warunkiem właściwej realizacji działań geodezyjnych i uzyskania wiarygodnych wyników jest praca z urządzeniem, dla którego możliwe jest stwierdzenie z dużą pewnością wysokiej dokładności dla określonych obszarów badań. W tym celu możliwe jest przeprowadzenie testów urządzenia pod kątem norm ISO 17123 lub zastosowanie innych metod badawczych i procedur. W niniejszym artykule przedstawiono wyniki testów stabilności automatycznej uniwersalnej stacji pomiarowej (robot universal measuring station – RUMS) S8 Trimble DR Plus ROBOTIC, która używana jest w Wydziale Geodezji uniwersytetu STU w Bratysławie w celach badawczych i naukowych.
Źródło:
Inżynieria Mineralna; 2014, R. 15, nr 1, 1; 85-90
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of long-term heating on the fatigue properties of low-alloyed cast steel STN 42 2707
Autorzy:
Bokuvka, O.
Jambor, M.
Novy, F.
Trsko, L.
Lago, J
Powiązania:
https://bibliotekanauki.pl/articles/111812.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
cast steel STN 42 2707
long-term heating
fatigue properties
Kath
da/dN = f(Ka)
staliwa
własności zmęczeniowe
pęknięcie zmęczeniowe
Opis:
In this paper the authors publish own experimental results of examination of low-alloyed cast steel STN 42 2707 fatigue properties (near- threshold regime of fatigue crack propagation for rates from da/dN =5.6x10-9m.cycle-1 to da/dN =10-12 m.cycle-1 and Kath at da/dN =10-12 m.cycle-1) initial state and after long-term heating (T = 400 °C, t = 4000 hours ≈ 167 days) obtained at high-frequency loading (f ≈ 20 kHz, T= 20 ± 5 °C, R = -1). The long-term heating of material caused decrease of Kath and increase of fatigue crack growth rate in the near-threshold regime; then worse of low-alloyed cast steel STN 42 2707 fatigue properties.
Źródło:
Production Engineering Archives; 2016, 12, 3; 30-33
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer aided subthalamic nucleus (STN) localization during deep brain stimulation (DBS) surgery in Parkinsons patients
Komputerowo wspomagana lokalizacja jądra niskowzgórzowego (STN) w przebiegu operacji głębokiej stymulacji mózgu (DBS) u pacjentów z chorobą Parkinsona
Autorzy:
Ciecierski, Konrad
Mandat, Tomasz
Rola, Rafał
Raś, Zbigniew W.
Przybyszewski, Andrzej W.
Powiązania:
https://bibliotekanauki.pl/articles/1037886.pdf
Data publikacji:
2014
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
parkinson’s disease
dbs
stn
spike detection
spike sorting
wavelet
neuronal noise
signal power
choroba parkinsona
wykrywanie potencjałów czynnościowych
grupowanie potencjałów czynnościowych
falki
neuronowy szum tła
moc sygnału
Opis:
INTRODUCTION During deep brain stimulation (DBS) treatment of Parkinson’s disease, the anatomical target of the surgery is a small (9 x 7 x 4 mm) deeply located structure called the Subthalamic Nucleus (STN). It is similar morphologically to the surrounding tissue and as such, not easily distinguished in CT or MRI. The goal of the surgery is precise placement of a permanent stimulating electrode within the target nucleus. Precision is extremely important as incorrect placement of the stimulating electrode may lead to serious adverse effects such as mood disturbances. MATERIALS AND METHODS To obtain the exact location of the STN nucleus, intraoperative stereotactic supportive navigation is used. A set of 3 ~ 5 parallel microelectrodes is inserted into the brain and advanced towards the expected location of the nucleus. From a depth of 10 mm above the estimated STN, the electrodes advance at 1 mm steps. At each step, the activity of the surrounding neural tissue is recorded. Typically, the electrodes are further advanced until the ventral STN border is passed and the Substantia Nigra pars reticulata (SNr) is reached. Because the STN has distinct physiological properties, signals recorded in the vicinity of the STN display specific features. Therefore it was possible to provide an analytical method to detect specific STN characteristics. This paper presents a computer-based approach in order to discriminate between microelectrode signals coming from the STN and those outside it. R E S U L TS A N D C O N C L US I O N S When our method was used on-line during DBS neurosurgical procedure, it helped in precise identification of STN borders and shorted the surgery. Since the fall of 2013, we have developed an on-line computer-aided application for STN border localization that is used during PD DBS surgeries performed in the Institute of Psychiatry and Neurology in Warsaw, POLAND.
WSTĘP Podczas zabiegu głębokiej stymulacji mózgu (deep brain stimulation – DBS) stosowanego w leczeniu choroby Parkinsona celem operacji jest mała (9 x 7 x 4 mm) głęboko położona struktura mózgu nazywana jądrem niskowzgórzowym (subthalamic nucleus – STN). Struktura ta jest morfologicznie podobna do otaczających ją tkaneki jako taka niezbyt dobrze rozróżnialna w obrazowaniu tomografem komputerowym (CT) lub rezonansem magnetycznym (MRI). Celem zabiegu operacyjnego jest precyzyjna implantacja stymulującej elektrody w docelowym jądrze. Precyzja jest niesłychanie istotna, ponieważ niewłaściwe umiejscowienie stymulującej elektrody może doprowadzić do wystąpienia poważnych efektów ubocznych, takich jak zaburzenia nastroju. MATERIAŁ I METODY Aby uzyskać dokładne położenie STN w trakcie operacji, używana jest wspomagająca nawigacja stereotaktyczna. Zestaw 3~5 równoległych elektrod jest wprowadzany do mózgu pacjenta i zagłębiany w kierunku spodziewanej lokalizacji STN. Od głębokości około 10 mm ponad spodziewanym STN elektrody są zagłębiane z krokiem 1 mm. Po każdym takim kroku rejestrowana jest aktywność tkanki nerwowej otaczającej elektrody. Najczęściej elektrody są dalej zagłębiane, aż przekroczą dolną granicę STN i osiągną istotę czarną część siatkowatą (substantia nigra pars reticulata – SNr). Ponieważ STN przejawia specyficzne właściwości fizjologiczne, sygnały zarejestrowane w jego okolicy również mają wyróżniające właściwości. Można przez to stworzyć analityczne metody wykrywające te specyficzne dla STN właściwości. W niniejszej publikacji zaprezentowano podejście informatyczne, pozwalające na wykrywanie zarejestrowanych sygnałów pochodzących z wewnątrz oraz spoza STN. WYNIKI I WNIOSKI Zastosowanie naszej metody w trakcie zabiegów operacyjnych pomogło w precyzyjnej lokalizacji granic STN oraz pozwoliło skrócić czas zabiegu. Od jesieni 2013 opracowujemy aplikację do wspomagania lokalizacji STN, która jest używana w trakcie zabiegów DBS przeprowadzanych w leczeniu choroby Parkinsona w Instytucie Psychiatrii i Neurologii w Warszawie.
Źródło:
Annales Academiae Medicae Silesiensis; 2014, 68, 5; 275-283
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies