Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power plant efficiency" wg kryterium: Temat


Tytuł:
A novel Data Envelopment Analysis model with complex numbers : measuring the efficiency of electric generators in steam power plants
Autorzy:
Esfandiari, Mahmood
Saati, Saber
Navabakhsh, Mehrzad
Khalili-Damghani, Kaveh
Powiązania:
https://bibliotekanauki.pl/articles/406274.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Data Envelopment Analysis
power plant
power plant efficiency
complex numbers
Opis:
The output of a generator in power plant is the electricity, and it consists of two parts, active and reactive power. These quantities are expressed as complex numbers in which the real part is the active power and the imaginary part is the reactive power. Reactive power plays an important role in an electricity network. Ignoring it will exclude a lot of information. With regard to the importance of the generators in power plants, surely, calculating the efficiency of these units is of great importance. Data Envelopment Analysis (DEA) is a nonparametric approach to measure the relative efficiency of Decision-Making Units (DMUs). Since the generators data are complex numbers, thus, if we the use classical DEA models in order to measure the efficiency of the generators in power plants, the reactive power cannot be considered, and the measurement is limited to the real number of electric power. In this paper, a new DEA model with complex numbers is developed in order to assess the performance of the power plant generators.
Źródło:
Operations Research and Decisions; 2019, 29, 4; 41-52
2081-8858
2391-6060
Pojawia się w:
Operations Research and Decisions
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The improvement of environmental characteristics of the combined cycle power plant by the implementation of the carbon capture installation
Autorzy:
Kotowicz, J.
Brzęczek, M.
Job, M.
Powiązania:
https://bibliotekanauki.pl/articles/134906.pdf
Data publikacji:
2015
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
combined cycle power plant
post-combustion technology
chemical absorption
carbon capture installation
power plant efficiency
ecological characteristics
Opis:
The paper describes a combined cycle power plant with carbon capture installation in a post-combustion technology. Carbon dioxide is separated from flue gas by using a chemical absorption method with monoethanolamine (MEA) as a sorbent. Separated carbon dioxide is compressed in order to prepare for transportation to the storage place. This paper identifies the electric efficiencies and other characteristic parameters of power plants before and after implementation of CO2 capture installation, as well as the power plant efficiency drop, and the improvement of ecological characteristics related to the implementation of this installation. The implementation of the installation described herein is associated with the efficiency loss caused by the auxiliary power for additional installations. The CO2 separation installation is powered by heat energy required for reclaiming the sorbent. This energy is taken in the form of steam extracted from the steam cycle, thus reducing the steam turbine power output, while the CO2 compression installation is powered by electric energy.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2015, 44 (116); 19-24
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wzrostu sprawności elektrowni oraz polityki CCS na wielkość zasobów bilansowych węgla brunatnego w warunkach bilateralnego monopolu kopalni i elektrowni
Influence of power station efficiency increase and CCS policy on size of lignite resources in condition of bilateral monopoly of a mine and a power station
Autorzy:
Jurdziak, L.
Kawalec, W.
Powiązania:
https://bibliotekanauki.pl/articles/283675.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
zasoby węgla brunatnego
koszty polityki CCS
sprawność elektrowni
wyrobisko docelowe
lignite reserves
costs of CCS policy
power plant efficiency
ultimate pit
Opis:
Przedstawiono studium zależności zasobów bilansowych złoża węgla brunatnego od sprawności elektrowni spalającej wydobywany węgiel oraz kosztów opłat za emisję dwutlenku węgla. Zasoby bilansowe wyznaczono metodą generowania wyrobiska docelowego kopalni odkrywkowej na podstawie modelu ekonomicznego złoża, przy założeniu, że produktem kopalni węgla jest energia, koszty jej wytworzenia w elektrowni są traktowane jak koszty przeróbki, zaś koszty opłat za emisję CO2 są kosztami sprzedaży produktu – energii. Dla potrzeb przykładowej analizy wykorzystano studialny model jakościowy złoża Legnica Wschód. Uzyskano wielowariantowe wyniki dla przyjętych poziomów sprawności elektrowni, kosztów emisji CO2 oraz różnych cen energii. Wyniki obliczeń wskazują, że w warunkach przewidywanych rosnących kosztów emisji CO2 tylko zapewnienie najwyższej dostępnej technicznie sprawności elektrowni (rzędu 45–48%) umożliwia zachowanie zasobów bilansowych węgla odpowiednich dla przynajmniej 25-letniej eksploatacji złoża. Wdrażanie wysokowydajnych technologii w energetyce węglowej jest zatem warunkiem koniecznym utrzymania opłacalności pozyskiwania energii z krajowych złóż węgla brunatnego.
The study of the dependency of lignite reserve on the lignite fuelled power plant efficiency as well as carbon allowances costs has been presented. The lignite economical reserves have been set with the use of algorithm of generating an ultimate pit on the basis of the economical block model of the lignite deposit. In this approach the electric energy embedded in the coal has been set as the product, costs of transforming chemical energy of coal into electric energy (power plant costs) have been treated as processing costs and the carbon allowances costs have been set as selling costs of the final product – energy. Thus the power plant efficiency can be implemented into both the product price “in-situ” and the processing costs. For the case study the quality block model of the lignite deposit Legnica Wschod has been used. Multivariant results of the computations for chosen power plant efficiency, carbon allowances costs and electrical energy prices have been obtained. The most interesting result is the loss of reserves due to rising carbon allowances costs. As long as these costs are relatively low, the power plant efficiency does not influence the ultimate pit reserves significantly. However when carbon allowances costs are higher (which is expected after implementation the full auctioning of carbon) only the highest power plant efficiency can save the lignite reserves for at least 25 years of mining exploitation necessary for the profitability of investments into the mine and the power plant bilateral monopoly.
Źródło:
Polityka Energetyczna; 2010, 13, 2; 181-197
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownia jako zakład przeróbki kopalni węgla brunatnego - nowe możliwości optymalizacji łącznych działań
A power station as a lignite processing plant - new possibilities of optimization of a lignite pit and a power station joint activity
Autorzy:
Jurdziak, L.
Kawalec, W.
Powiązania:
https://bibliotekanauki.pl/articles/349059.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
zintegrowana kompania energetyczna
łączna optymalizacja kopalni i elektrowni
zasoby węgla brunatnego
sprawność elektrowni
integrated power engineering company
joint optimization of a lignite pit and a power station
lignite reserves
power plant efficiency
Opis:
Przedstawiono koncepcję integracji działań kopalni węgla brunatnego i elektrowni, w której elektrownia jest pozycjonowana jako zakład przeróbki węgla. Rozpatrywanie zróżnicowanych parametrów "przeróbki" (sprawności, kosztów procesu, strat własnych wytworzonej energii) oraz kosztów sprzedaży energii - gotowego produktu (np. kosztów uprawnień emisji dwutlenku węgla) umożliwia analizowanie wariantów zintegrowanej pionowo kompanii energetycznej. Korzyści z zastosowania nowej koncepcji to: identyfikacja zasobów bilansowych złoża węgla brunatnego - źródła energii dla elektrowni, wyznaczanie dokładnej emisyjności CO2 węgla dla przyjętego scenariusza postępu kopalni, analiza wpływu rynku uprawnień emisji dwutlenku węgla na wielkość zasobów, wyznaczanie potrzebnego poziomu sprawności elektrowni dla zachowania wielkości zasobów węgla zgodnych z założeniami kompleksu oraz szybka reoptymalizacja działań zintegrowanego układu po zmianie istotnych warunków. W przykładowej analizie wykorzystano studialny model jakościowy złoża Legnica Wschód. Uzyskano wielowariantowe wyniki dla przyjętych poziomów sprawności elektrowni, kosztów emisji CO2 oraz różnych cen energii.
An idea of an integration of joint activity of a lignite surface mine and a lignite fuelled power plant, that treats the power plant as a processing plant of the mine has been presented. Consideration of various parameters of "processing" (power plant efficiency, internal losses of produced energy) as well as selling costs of the final product - electric energy (e.g. carbon allowances costs) allows to analyze optional scenarios of the vertically integrated power engineering company. Advantages of such approach are: identification of mineable reserves as a raw energy source for a power plant, an exact assessment of CO2 emission for a given mine schedule, analysis of the impact of carbon allowances trading, identification of the necessary level of a power plant efficiency which maintains the lignite reserves within the presumed assumptions of the whole power engineering enterprise, quick re-optimisation of the activity the integrated complex following the changes of key parameters. The case study, developed upon the quality block model of the Legnica East lignite deposit, shows the multivariate results obtained for various levels of power plant efficiency, carbon allowances costs and energy pricing.
Źródło:
Górnictwo i Geoinżynieria; 2011, 35, 3; 95-101
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected aspects of the choice of live steam pressure in PWR nuclear power plant
Autorzy:
Laskowski, Rafał
Smyk, Adam
Jurkowski, Romuald
Ancé, Julien
Wołowicz, Marcin
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2134928.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
live steam
pressure
efficiency
power output
nuclear power plant
nuclear
power
plant
performance
entropy balance
Opis:
In commercially available generation III and III+ PWR (pressurized water reactor) reactors, pressure of steam produced in steam generators varies in a relatively wide range from 5.7 to 7.8 MPa. Therefore, it is important to ask which value of steam pressure should be used for a specific unit, taking into account different location conditions, the size of the power system and conditions of operation with other sources of electricity generation. The paper analyzes the effect of steam pressure at the outlet of a steam generator on the performance of a PWR nuclear power plant by presenting changes in gross and net power and efficiency of the unit for steam pressures in the range of 6.8 to 7.8 MPa. In order to determine losses in the thermal system of the PWR power plant, in particular those caused by flow resistance and live steam throttling between the steam generator and the turbine inlet, results concerning entropy generation in the thermal system of the power plant have been presented. A model of a nuclear power plant was developed using the Ebsilon software and validated based on data concerning the Olkiluoto Unit 3 EPR (evolutionary power reactor) power plant. The calculations in the model were done for design conditions and for a constant thermal power of the steam generator. Under nominal conditions of the Olkiluoto Unit 3 EPR power unit, steam pressure is about 7.8 MPa and the steam dryness fraction is 0.997. The analysis indicates that in the assumed range of live steam pressure the gross power output and efficiency increase by 32 MW and 0.735 percentage point, respectively, and the net power output and efficiency increase by 27.8 MW and 0.638 percentage point, respectively. In the case of all types of commercially available PWR reactors, water pressure in the primary circuit is in the range of 15.5−16.0 MPa. For such pressure, reducing the live steam pressure leads to a reduction in the efficiency of the unit. Although a higher steam pressure increases the efficiency of the system, it is necessary to take into account the limitations resulting from technical and economic criteria as well as operating conditions of the primary circuit, including the necessary DNBR (departure from nucleate boiling ratio) margin. For the above reasons, increasing the live steam pressure above 7.8 MPa (the value used in EPR units that have already been completed) is unjustified, as it is associated with higher costs of the steam generator and the high-pressure part of the turbine.
Źródło:
Archives of Thermodynamics; 2022, 43, 3; 85--109
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Condensing power plant cycle - assessing possibilities of improving its efficiency
Autorzy:
Chmielniak, T.
Łukowicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/240030.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Elektrownie kondensacyjne
poprawa efektywości
condensing power plant
Efficiency improvement
Opis:
This paper presents a method for assessing the degree of approaching the paper output of the Clausius-Rankine cycle to the Carnot cycle. The computations to illustrate its use were performed for parameters characteristic of the current state of development of condensing power plants as well as in accordance with predicted trends for their further enhancing. Moreover there are presented computations of energy dissipation in the machines and devices working in such a cycle.
Źródło:
Archives of Thermodynamics; 2010, 31, 3; 105-113
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of a combined cycle power plant located in Jordan: A case study
Autorzy:
Bataineh, Khaled
Khaleel, Bara A.
Powiązania:
https://bibliotekanauki.pl/articles/240565.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
energy efficiency
exergy efficiency
exergy destruction
exergy losses
Opis:
Efficiency and electrical power output of combined cycle power plants vary according to the ambient conditions. The amount of these variations greatly affects electricity production, fuel consumption, and plant incomes. Obviously, many world countries have a wide range of climatic conditions, which impact the performance of power plants. In this paper, a thermodynamic analysis of an operating power plant located in Jordan is performed with actual operating data acquired from the power plant control unit. The analysis is performed by using first and second laws of thermodynamics. Energy and exergy efficiencies of each component of the power plant system are calculated and the effect of ambient temperature on the components performance is studied. The effects of gas turbine pressure ratio, gas turbine inlet temperature, load and ambient conditions on the combined cycle efficiency, power outputs and exergy destruction are investigated. Energy and exergy efficiencies of the combined cycle power plant are found as 45.29%, and 42.73% respectively when the ambient temperature is 34°C. Furthermore, it is found that the combustion chamber has the largest exergy destruction rate among the system components. The results showed that 73% of the total exergy destruction occurs in the combustion chamber when the ambient temperature is 34°C. Moreover, the results show that the second major exergy loss is in HRSC. The results show that the energy and exergy efficiency of the combined cycle power plant decreases as the ambient temperature increases. According to the calculation results, improvement and modification suggestions are presented.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 95-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vlianie temperatury okruzausej sredy na velicinu eksergeticeskogo KPD glavnogo dvigatela
The Influence of Ambient Temperature on the Efficiency Factor of Main Engine Operation
Autorzy:
Behrendt, C.
Motornyj, A.
Powiązania:
https://bibliotekanauki.pl/articles/359702.pdf
Data publikacji:
2004
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
EXPLO-SHIP 2004
marine power plant
main engine
efficiency factor
ambient temperature
Opis:
The factor of thermal efficiency, used for the assessement of the use of heat in the diesel engine working cycles, has been based on the the first law of thermodynamics only. This paper indicates the fact that to achieve more comprehensive thermodynamic analyses it is necessary to use factors based on the two laws of thermodynamics. One such factor herein proposed is the exoergic efficiency. The method for the determination of this factor for the main engine is presented. Original relations involving the exoergic efficiency are set out. The factor depends on the ambient temperature.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2004, 1 (73); 21-29
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie efektowności turbin wiatrowych dużej mocy
Research studies on the efficiency of wind turbine generators
Autorzy:
Szczyrba, T.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/159046.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
turbiny wiatrowe
elektrownie wiatrowe
sprawność
wydajność
efektywność
wind turbine
efficiency
power curve
wind power plant
generator
Opis:
Podstawowym celem przeprowadzonych badań, było określenie wpływu zmian gęstości powietrza atmosferycznego na wyniki obliczeń wskaźników charakteryzujących efektywność elektrowni wiatrowych. Przy czy założono, że efektywność opisuje wielkość energii elektrycznej wyprodukowanej w określonym przedziale czasowym, przy istniejących warunkach atmosferycznych dla danej lokalizacji i przy uwzględnieniu jakości wyprodukowanej energii oraz rzeczywistej sprawności podzespołów prądotwórczych instalacji wiatrowych i ich układów sterowania. W części opisowej scharakte-ryzowano zastosowane urządzenia pomiarowe, usytuowanie mierników i sposób ich kalibracji oraz podstawowe zalecenia dotyczące metodyki wykonywania pomiarów wartości temperatury, ciśnienia oraz wilgotności powietrza atmosferycznego. Natomiast w części wynikowej przedstawiono wykresy obrazujące wpływ zarejestrowanych parametrów atmosferycznych i obliczonej na ich podstawie gęstości powietrza na przebiegi empirycznej krzywej mocy oraz na wartości rzeczywistej sprawności.
The primary objective of the research studies was to determine the impact of the air density changes on the calculation results of indicators characterizing the efficiency of a wind power plant. The equipment used for measuring purposes, location of metres and their calibration methods were characterized in the descriptive part of the article. Additionally, basic recommendations on the methodology of measuring the ambient air values of temperature, pressure and humidity. Wherein, it was assumed that the efficiency is being described by the electric force generated in a specified period of time, under existing weather conditions for the given location, taking into account the quality of the generated energy and the real efficiency of components of the wind turbine generators and their control systems. In the part of the describing the results, graphs showing the impact of the recorded atmospheric parameters on the courses of empirical power curve and the real efficiency value were presented.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 97-104
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of energy use and elimination of CO2 emissions in the life cycle of an offshore wind power plant farm
Autorzy:
Tomporowski, A.
Flizikowski, J.
Opielak, M.
Kasner, R.
Kruszelnicka, W.
Powiązania:
https://bibliotekanauki.pl/articles/258566.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
energy efficiency
use of machines
offshore wind power plant farms
CO2 emissions
Opis:
Power stations in marine locations cause multi-faceted impact on the environment, man and the economy. There are not many studies devoted to modeling energy benefits for CO2 emissions. The paper presents the issues of assessing the efficiency of offshore wind farms, defined as the ratio of benefits to life cycle inputs. The scientific goal was to develop a mathematical model for efficiency in the design, manufacture, use and management of offshore wind power. The papers practical purpose is the experimental designation of the impact of selected post-use management methods, time of use and maritime location, i.e. average annual productivity of wind power plants on the efficiency of energy benefits from greenhouse gas emissions. The mathematical model of the integrated cost-benefit ratio has been developed for energy use assessment, taking into account the benefits generated by electricity production and the life-cycle CO2 emissions based on the LCA analysis using the CML method. Mathematical model validation was performed by determining the value of the indicator for an existing 2 MW offshore wind farm and comparatively for fossil fuel production: lignite, stone, fuel oil and natural gas. Analytical and research work carried out showed that the higher the efficiency index, the higher the value of the indicator. It has been shown that the location of the power station at sea produces more favorable CO2 elimination rates, due to higher productivity compared to in-land wind power plants. A more favorable form of post-consumer management for CO2 has been determined as recycling. It was found that for electricity generated from offshore wind farms, the value of the energy efficiency benefit from CO2 emissions is higher than for fossil fuel energy production.
Źródło:
Polish Maritime Research; 2017, 4; 93-101
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the Efficiency of Treatment Model Mixtures of Petroleum Products with the Modified Sorbent Made of Ash-and-Slag During Dynamic Sorption
Autorzy:
Korotkova, Tatyana Germanovna
Bushumov, Svyatoslav Andreevich
Ksandopulo, Svetlana Yurevna
Solonnikova, Nataliya Vladimirovna
Powiązania:
https://bibliotekanauki.pl/articles/123373.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ash and slag
thermal power plant
sorbent
sorption dynamics
efficiency
petroleum products
extraction
Opis:
Experimental studies on the dynamic sorption of model mixtures containing petroleum products were performed. The subject of the study was the modified sorbent from the ash-and-slag wastes accumulated in the ash dump of the Novocherkassk State District Power Plant (SDPP) (Russia, Novocherkassk, Rostov Region), obtained using the method of ash removal. The quantity of the sorbent for each model solution was fixed at 5.0 g. The model solutions in the amount of 1 dm3 were passed through a column filled with the modified sorbent at constant filtration rate w = const with filtrate takeout of 0.1 dm3/min. The pH value of the solution, which is advisable for extracting petroleum products, was determined experimentally. For this purpose, the model solutions, containing 100 mg/dm3 of petroleum products with pH = 1.65, 4.01, 6.86, 8.12, 9.18, and 11.34, were prepared. The optimum pH value of the solution was considered pH = 7.5. The content of petroleum products in the filtrate in all experiments was determined using IR spectrometry. The working range of water pollution with petroleum products was determined on a series of model solutions containing petroleum products in the range between 0.5 and 10 mg/dm3 with the increment of 0.5, between 10 and 100 mg/dm3 with the increment of 10, and between 100 and 1,000 mg/dm3 with the increment of 100. The maximum extraction of petroleum products from the solution was 88.23%. The applicability of the Henry’s law to the range of petroleum products concentrations in the filtrate of 50 mg/dm3 was confirmed. The adsorption equilibrium constant (Henry’s law constant) was determined experimentally. The effect of the natural freshwater matrix on the degree of petroleum products extraction was studied; no significant effect on petroleum products sorption was found. A conclusion was made that the sorbent can ensure the efficiency of water purifying from petroleum products of no less than 85% in the range of pollution between 5 and 300 mg/dm3.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 202-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan i perspektywy rozwoju układów gazowo-parowych
Status and developement perspectives of combined cycle plants
Autorzy:
Kotowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/172928.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gaz ziemny
układ gazowo-parowy
elektrownia gazowo-parowa
sprawność energetyczna
natural gas
gas-steam plant
steam-gas power plant
power efficiency
Opis:
W artykule omówiono układy gazowo-parowe opalane gazem ziemnym. Zwrócono uwagę na genezę wysokiej sprawności oraz pokazano wiele innych zalet tych układów. Przedstawiono szereg koncepcji dalszego wzrostu sprawności elektrowni gazowo-parowych, począwszy od zwiększenia temperatury na wlocie do turbiny gazowej, poprzez organizację procesu chłodzenia, aż do sposobów podniesienia sprawności części parowej układu. Scharakteryzowano najnowsze rozwiązanie światowych liderów w produkcji turbin gazowych i układów gazowo-parowych. Przedstawiono różne koncepcje układów kombinowanych z instalacją sekwestracji dwutlenku węgla: układ z absorpcją przy użyciu monoetanoloaminy, układ ze spalaniem tlenowym i koncepcja zaawansowanego zero emisyjnego układu z reaktorem membranowym. Pokazano również sprawność tych koncepcji.
The paper focuses on a natural gas-fired combined cycle plants. Thermodynamic efficiency issues of these plants are discussed. Different concepts of the improvement of this parameter are presented starting from temperature increase at the gas turbine inlet through the cooling system arrangement to the increase of steam cycle efficiency. The latest solutions of world leaders in production of gas turbines and combined cycle plants were characterized. The following concepts of these plants were presented: a plant with an absorption installation with the use of MEA, a plant with oxy-fired combustion chamber and an advanced concept of zero-emission plant with a membrane reactor. The efficiency and CO2 emission of these concepts were presented.
Źródło:
Archiwum Energetyki; 2012, 42, 1; 23-38
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical thermodynamic optimization of supercritical coal fired power plant with support of IPSEpro software
Autorzy:
Elsner, W.
Kowalczyk, Ł.
Marek, M.
Powiązania:
https://bibliotekanauki.pl/articles/240118.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optymalizacja termodynamiczna
siłownia nadkrytyczna
symulacja
wydajność
efficiency
simulation
supercritical power plant
thermodynamic optimization
Opis:
The paper presents a thermodynamic optimization of supercritical coal fired power plant. The aim of the study was to optimize part of the thermal cycle consisted of high-pressure turbine and two chosen high-pressure feed water heaters. Calculations were carried out using IPSEpro software combined with MATLAB, where thermal efficiency and gross power generation efficiency were chosen as objective functions. It was shown that the optimization with newly developed framework is sufficiently precise and its main advantage is the reduction of computation time on comparison to the classical method. The calculations have shown the tendency of the increase in efficiency, with the rise of a number of function variables.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 101-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność ekonomiczna hybrydowej mikroinstalacji OZE
Efficiency of hybrid microinstallation with renewable energy sources
Autorzy:
Bogalecka, Elżbieta
Krzemiński, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/266952.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
mikroelektrownia hybrydowa
efektywność
moc bierna
czas zwrotu nakładów
small hybrid power plant
efficiency
reactive power
payback period
Opis:
W artykule przedstawiono warunki pracy mikroelektrowni hybrydowej zainstalowanej w małej firmie mieszczącej się na terenie przemysłowym. Pokazano strukturę i parametry elektrowni składającej się z paneli fotowoltaicznych i elektrowni wiatrowej. Przeanalizowano odbiorniki energii oraz warunki pobierania mocy biernej. Dla wybranego okresu czasu pokazano zużycie oraz produkcję energii elektrycznej i energię zużytą na potrzeby firmy oraz oddaną do sieci. Na podstawie cen energii określono czas zwrotu nakładów inwestycyjnych już poniesionych. Zbadano celowość modernizacji przekształtników w elektrowni polegającej na wymianie tranzystorów IGBT na tranzystory SiC i celowość zakupu magazynu energii. Wykazano, że poniesione nakłady zwrócą się po ponad 10 latach. Nieuchronny wzrost cen energii spowoduje skrócenie czasu zwrotu nakładów inwestycyjnych do mniej niż 10 lat.
The article presents the working conditions of a hybrid micro-plant installed in a small company located in an industrial area. The structure and parameters of a power plant consisting of photovoltaic panels and a wind power plant are shown. The energy receivers and the conditions of reactive power consumption were analyzed. For the selected period of time, the consumption and production of electricity and energy consumed for the needs of the company and sent to the network were shown. On the basis of energy prices, the payback period of investment outlays was determined. When examining economic efficiency, usually only active power is taken into account. The analysis takes into account the possibility of reactive power compensation by wind turbine and solar power converters. The purposefulness of modernization of converters in a power plant relying on the replacement of IGBT transistors by SiC transistors and the purposefulness of purchasing an energy storage was examined. It has been shown that the expenditure incurred will pay back after more than 10 years. The inevitable increase in energy prices will shorten the payback period of investment outlays to less than 10 years.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 19-22
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies