Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gas detector" wg kryterium: Temat


Wyświetlanie 1-15 z 15
Tytuł:
Needle detector of X-ray and gamma radiation
Detektor igłowy promieniowania X i gamma
Autorzy:
Domański, G.
Szabatin, R.
Brzeski, P.
Konarzewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/408828.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
gas detector with electron multiplication
x-ray detector
gamma radiation
detektor z gazowym powielaniem elektronów
detektor promieniowania X
promieniowanie gamma
Opis:
The article presents the developed structure of the novel needle proportional gas detector (NPC – Needle Proportional Counter) used for the detection of X-rays and gamma rays. The advantage of the detector is its simple mechanical construction and the possibility of detection of incident radiation in a direction parallel to the needle. The measured energy spectrum of the isotope Fe-55 by means of the developed detector is presented.
Artykuł przedstawia opracowaną konstrukcję nowego typu gazowego detektora igłowego, służącego do detekcji promieniowania X i gamma. Zaletą detektora jest jego prosta konstrukcja mechaniczna i możliwość detekcji promieniowania w kierunku równoległym do igły. Zmierzono widmo energetyczne izotopu Fe-55 opracowanym detektorem.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 121-124
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detektory gazowe – drugie życie w badaniach termojądrowych
Gas detectors – second life in thermonuclear research
Autorzy:
Chernyshova, Maryna
Kowalska-Strzęciwilk, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/24201012.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plazma gorąca
diagnostyka plazmy
detektor rentgenowski
detektor gazowy
powielacz elektronowy
powielacz gazowy
hot plasma
plasma diagnostics
X-ray detector
gas detector
electron multiplier
gas multiplier
Opis:
Poszukiwanie najnowszych technologii w dziedzinie diagnostyki plazmy jest napędzane rosnącymi wymogami dotyczącymi stabilności materiałów, pod wpływem rożnego rodzaju promieniowania, stosowanych w budowie i eksploatacji urządzeń termojądrowych. W miarę postępu tych urządzeń, badanie procesów zachodzących podczas oddziaływania promieniowania z materią staje się coraz bardziej istotne. W tym kontekście poszukiwanie innowacyjnych technologii, zwłaszcza w detekcji obrazowej promieni X, staje się niezbędne dla nowej generacji reaktorów, takich jak ITER, oraz przyszłej elektrowni termojądrowej DEMO. Współcześnie powszechnie używane detektory promieniowania rentgenowskiego stosowane w takich warunkach stoją przed znaczącym wyzwaniem – szybką degradacją pod wpływem intensywnych strumieni neutronów charakterystycznych dla urządzeń termojądrowych. Kwestia ta wytycza potrzebę opracowania nowej technologii detekcji promieniowania rentgenowskiego dostosowanej do unikalnych wymagań obecnych oraz przyszłych urządzeń termojądrowych, z naciskiem na ich odporność i trwałość. Mimo iż tradycyjnie detektory półprzewodnikowe są wciąż wykorzystywane do rejestracji miękkich promieni rentgenowskich (z ang. SXR – Soft X-Ray), to istnieje rosnące zainteresowanie badaniem detektorów gazowych w układach plazmowych, jako bardziej obiecujących kandydatów ze względu na ich inherentną odporność na promieniowanie neutronowe. Wśród nowej klasy detektorów gazowych szczególnym wyróżnieniem cieszy się detektor typu GEM (z ang. GEM – Gas Electron Multiplier). Detektor tej klasy wykazuje wysoki współczynnik wzmocnienia dla pierwotnego ładunku pochodzącego z absorpcji fotonów, co między innymi czyni go właściwym wyborem do zastosowań w przyszłych reaktorach termojądrowych.
The search for the latest technologies in the field of plasma diagnostics is driven by increasing requirements for material stability under the influence of various types of radiation used in the construction and operation of thermonuclear devices. As these devices advance, studying the processes that occur during radiation-matter interactions becomes increasingly important. In this context, the search for innovative technologies, especially in X-ray imaging detection, becomes essential for future reactors such as ITER and the future thermonuclear power plant DEMO. Currently widely used X-ray radiation detectors used in such conditions face a significant challenge - rapid degradation under the influence of intense neutron flux characteristic of thermonuclear devices. This problem necessitates the development of new X-ray detection technology tailored to the unique requirements of current and future thermonuclear devices, with a focus on their resistance and durability. Although semiconductor detectors are traditionally used for soft X-ray (SXR) detection, there is growing interest in studying gas detectors for plasma devices as more promising candidates due to their inherent resistance to neutron radiation. Among the new class of gas detectors, the Gas Electron Multiplier (GEM) type detector is particularly notable. This type of detector exhibits a high gain coefficient for the primary charge resulting from photon absorption, making it, among other things, a noteworthy choice for applications in future thermonuclear reactors.
Źródło:
Postępy Techniki Jądrowej; 2023, 4; 18--33
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of explosive gases with a portable gas detector Drager X-am 5600
Autorzy:
Macuda, J.
Łukańko, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/298601.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
methane
hydrogen sulfide
measurement of methane concentration
monitoring of explosive gases
portable gas detector
exploration of hydrocarbon deposits
extraction of hydrocarbons
tubing
reservoir water
Opis:
During exploration and extraction of hydrocarbon deposits, the risk of elevated methane concentration above the lower explosive limit occurs. In some cases a higher concentration of hydrogen sulfide threatening the health and life of the crew also may be observed. The use of a portable gas detector Dräger X-am 5600 for constant monitoring of methane and hydrogen sulfide concentration in dangerous situations is proposed in the paper. Thanks to the IR sensors and modern electrochemical sensors, this detector allows for monitoring of 6 types of gases simultaneously. The applied infrared sensor IR EX allows for measuring explosive and combustible gases both within the lower explosive limit, and also measuring of methane in the range of 0 to 100 vol.%. The measured values are stored in the computer and also sent to the central through GSM.
Źródło:
AGH Drilling, Oil, Gas; 2017, 34, 2; 543-551
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Silicon TCD for the methane and carbon monoxide detection
Autorzy:
Łysko, J. M.
Latecki, B.
Nikodem, M.
Górska, M.
Mróz, J.
Małachowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/308823.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
detector
silicon
gas mixture
Opis:
Analytical model, design principles, technology and test results concerning a thermal conductivity detector (TCD) are presented. Prototype TCD units fabricated using the standard silicon IC VLSI and MEMS techniques are reported. The detectors are integrated with gas separation columns and micro-valve dosing systems. Initial tests were carried out in a gas mixture containing methane, carbon monoxide, oxygen, hydrogen and nitrogen.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 94-97
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas micro-flow-metering with the in-channel Pt resistors
Autorzy:
Łysko, J. M.
Latecki, B.
Nikodem, M.
Powiązania:
https://bibliotekanauki.pl/articles/308828.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
detector
silicon
gas
flow
thermo-conductivity
Opis:
Standard thermo-conductive gas flow meters have the side-channel integrated with the temperature detector and heater coils, both winded around the tube. This design suffers from a high thermal capacity, reduced sensitivity in the lower limit flow range, high thermal inertia, long response time and necessity to amplify electronically the output signal. The newly designed TCD detector can be applied as a precise gas flow meter. To identify the composition of the unknown gas, the TCD unit requires a connection to the separation column, application of the reference channel and highly stable flow rate regulator. To measure flow rates, the same TCD unit requires only one flow channel application, with active resistors inside it, and a definition of the gas type. In this work principles of the TCD design, technology and flow rate sensitivity tests are presented.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 98-100
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement the of radon gas concentrations of soil samples in Ishtar residential gleaner at the Tuwaitha nuclear site
Autorzy:
Meethaq, alib Hassan
Mahmood, Salim Karim
Powiązania:
https://bibliotekanauki.pl/articles/1177783.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
222Rn gas
Rad-7 detector
Tuwaitha site
Opis:
Radon irradiated and its solid products are the largest contributors to. Its concentration in soil gas is much greater than that of other sources. Therefore, the total inhalation dose and are harmful to human health it is necessary to measure the concentration of radon in the soil. This study investigated the measurements of radon irradiated 222Rn concentrations at 20 sites of the Ishtar residential gleaner at the Tuwaitha nuclear site using the RADON electronic detector manufactured by RAD7 (Durridge Company Inc., USA). Measurements were carried out at a depth of (10 cm), (A10 region) which was equal to (1590±176 Bq/m3), while the lowest average radon gas concentration was found in (A17 region) which was equal to (130±36.6 Bq/m3), with an average value of (698±162 Bq/m3), The results obtained from this study indicate .The present results in all areas of study have shown that the radon gas concentrations in soil samples were higher value of the recommended value (200 Bq/m3) given by (ICRP, 1993).
Źródło:
World Scientific News; 2018, 100; 233-238
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plasma characterization of the gas-puff target source dedicated for soft X-ray microscopy using SiC detectors
Autorzy:
Torrisi, A.
Wachulak, P.
Torrisi, L.
Bartnik, A.
Węgrzyński, Ł.
Fiedorowicz, H.
Powiązania:
https://bibliotekanauki.pl/articles/147432.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gas-puff target
plasma diagnostic technique
SiC detector
‘water-window’
EUV
Opis:
An Nd:YAG pulsed laser was employed to irradiate a nitrogen gas-puff target. The interaction gives rise to the emission of soft X-ray (SXR) radiation in the ‘water window’ spectral range (λ = 2.3÷4.4 nm). This source was already successfully employed to perform the SXR microscopy. In this work, a Silicon Carbide (SiC) detector was used to characterize the nitrogen plasma emission in terms of gas-puff target parameters. The measurements show applicability of SiC detectors for SXR plasma characterization.
Źródło:
Nukleonika; 2016, 61, 2; 139-143
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gain prediction theory of single foil gas electron multiplier detector
Teoria wzmocnienia jednofoliowego detektora z gazowym powielaniem elektronów
Autorzy:
Domański, G.
Szabatin, R.
Kalenik, J.
Jaworski, A.
Wróblewski, P.
Smolik, W.
Kurjata, R.
Konarzewski, B.
Dziewiecki, M.
Marzec, J.
Zaremba, K.
Ziembicki, M.
Rychter, A.
Kryszyn, J.
Brzeski, P.
Szmidt, J.
Powiązania:
https://bibliotekanauki.pl/articles/408074.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
Gas Electron Multiplier
ionizing radiation detector
detektor z gazowym powielaniem elektronów
detektor promieniowania
Opis:
Gain prediction theory of single foil Gas Electron Multiplier detector was developed. Gas electron multiplier (GEM) detector with single foil was developed. Soft X-ray spectra with an energy of 5.9 keV emitted by the isotope Fe-55 were measured. On this basis, the dependence of gain and energy resolution from the detector voltage was determined. The simple theory of gain dependence on various detector parameters was developed. Preliminary results of the study confirmed the potential usefulness of the GEM detector as a substitute for the multiwire proportional chamber.
Opracowano teorię wzmocnienia jednofoliowego detektora z gazowym powielaniem elektronów. Opracowano detektor z gazowym powielaniem elektronów z pojedynczą folią. Zmierzono widmo miękkiego promieniowania X, o energii 5,9 keV, emitowanego przez izotop Fe-55. Na tej podstawie wyznaczono zależność wzmocnienia i energetycznej zdolności rozdzielczej od napięcia zasilającego detektor. Opracowano prosta teorią zależności wzmocnienia od różnych parametrów detektora. Wstępne rezultaty badań potwierdzają potencjalną przydatność detektora GEM jako substytutu wielodrutowej komory proporcjonalnej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 130-132
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modyfikacja zasilania wodorem inwersyjnego chromatografu gazowego
The modification of hydrogen supply of the inverse gas chromatograph
Autorzy:
Dziewit, N.
Słomkiewicz, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/270809.pdf
Data publikacji:
2014
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
generator wodoru
inwersyjny chromatograf gazowy
detektor płomieniowo-jonizacyjny
hydrogen generator
inverse gas chromatography
detector FID
Opis:
Opracowano zmodyfikowany system zasilania wodorem inwersyjnego chromatografu gazowego z generatora wodoru. Polega on na zastosowaniu dodatkowego zbiornika buforowego i regulatora ciśnienia toru wodorowego. Uzyskano zmniejszenie oscylacji prądu detektora FID i jego pracę w dopuszczalnym zakresie wartości temperatur.
The modified system of hydrogen supply the inverse gas chromatograph from hydrogen generator was elaborated. It depends on the use of additional buffer reservoir and the regulator of pressure of hydrogen track. The decrease of the oscillations of current of detector the FID and the admittance range of temperatures value of his work were received.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2014, 19, 3; 245-250
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie analizy chromatograficznej w odlewnictwie
Chromatographic Analysis in Foundry Processes
Autorzy:
Szymański, Ł.
Żymankowska-Kumon, S.
Powiązania:
https://bibliotekanauki.pl/articles/383077.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chromatografia gazowa
spoiwo
odlewnictwo
związek BTEX
detektor płomieniowo jonizacyjny
gas chromatography
binder
founding
BTEX compounds
flame ionization detector
Opis:
Odlewnictwo należy do gałęzi przemysłu o zwiększonym ryzyku zawodowym. Podczas całego procesu produkcji odlewów pracownicy narażeni są na niebezpieczne, szkodliwe i uciążliwe czynniki związane między innymi z emisją szkodliwych substancji. Jedną z przyczyn emisji są stosowane w odlewnictwie spoiwa (np. żywice lub nośniki węgla błyszczącego stosowane w masach z bentonitem) i utwardzacze ulegające w wysokiej temperaturze rozkładowi termicznemu. Wiąże się to z powstawaniem szeregu mniej lub bardziej szkodliwych związków organicznych. W zależności od rodzaju stosowanej żywicy, pod wpływem temperatury mogą tworzyć się i uwalniać takie związki jak: alkohol furfurylowy, formaldehyd, fenol, związki z grupy BTEX (benzen, toluen, etylobenzen, ksyleny). Chromatografia gazowa jest jedną z przydatnych technik do analizy wyżej wymienionych związków z grupy BTEX. W pracy skupiono się głównie na preparatyce próbek przed pomiarem chromatograficznym. Popełnienie błędu na tym etapie badań eliminuje późniejsze wyniki analizy. Wybór odpowiedniego rozpuszczalnika (eter dietylowy, disiarczek węgla), służącego do wymywania związków z grupy BTEX oraz etapowe przygotowanie próbek zapewni uzyskanie wiarygodnych i powtarzalnych wyników badań. Przedmiotem analizy były zaadsorbowane podczas pomiarów na odlewni gazy, pochodzące z zalewania ciekłym metalem masy formierskiej, sporządzonej na bazie popularnych spoiw stosowanych w odlewnictwie. Do badań wykorzystano chromatograf gazowy z detektorem płomieniowo-jonizacyjnym FID (ang. Flame Ionization Detektor).
Foundry engineering belongs to an industrial branch of an increased professional risk. During the whole casting production process employees are exposed to dangerous, harmful and uncomfortable factors related, among others, to emissions of harmful substances. One of the reasons of such emission are binding agents applied in foundry practice (e.g. resins or lustrous carbon carriers applied in bentonite sands) and hardeners undergoing thermal decomposition at high temperatures. Due to this, several more of less harmful organic compounds are formed. In dependence on the applied resin, under a temperature influence can be formed and released such compounds as: furfuryl alcohol, formaldehyde, phenol, BTEX group. Gas chromatography is one of the useful techniques for the analysis of compounds from the group BTEX. The study focused on the samples preparation and selection of a suitable solvent (diethyl ether, carbon disulfide), to ensure a reliable and repeatable test results. The aim of this study was the determination the temperature influence on formation substances from the BTEX group, during thermal decomposition of the selected binder, used in foundry processes. The analysis was carried out by the gas chromatography method with the application of the flame-ionising detector (FID).
Źródło:
Archives of Foundry Engineering; 2013, 13, 3 spec.; 167-170
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sravnitelʹnyj analiz datčikov gazovyh izveŝatelej dlâ rannego obnaruženiâ požara
Comparative Analysis of Sensors Contained in Gas Detectors Designed For Early Fire Detection
Analiza porównawcza czujników wykorzystywanych w czujkach gazu do wczesnego wykrywania pożaru
Autorzy:
Kozubovskiy, V. R.
Misevich, I. Z.
Ivanchuk, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/372872.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
detector
multisensory
gas
sensor
concentration
electrochemical
electrolytic
oxidic
pożar
czujka
wielosensorowy
dym
gaz
czujnik
stężenie
elektrochemiczny
tlenkowy
elektrolityczny
Opis:
Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.Aim: The purpose of this article is to help designers of fire detectors with the selection of a carbon monoxide (CO) sensor for a multi-sensor fire detector. Academic work on detectors provides an abundance of material about sensors suitable for CO analysis. Each sensor has its advantages and disadvantages. Therefore, choosing a suitable sensor is quite difficult. The authors, based on their extensive experience in the development and production of devices for gas analysis and fire detectors, propose most adequate solutions. Introduction: Current devices for discovering a fire, work on the principle of detecting smoke, often incorporating a temperature sensor. However, these have many disadvantages. They do not function in a discerning way in relation to smoke (aerosols, water vapour, cooking vapour and dust are all identified as smoke). A CO fire detector is free of these shortcomings, since it is selective and reacts to CO. For this reason many perspective European norms and international standards emerged, which recommend CO analysis for detection of fires. Obviously, high concentrations of CO can occur in areas where people smoke, where heating appliances utilising solid and gaseous fuels are used, in garages and in underground car parks. Multi-Sensor Detectors with two methods of detecting fire, CO and smoke, compensate shortcomings of each method. It can be confidently stated that through a simultaneous response from both detection methods, a fire will be dealt with at an early stage of development and resources will not be sidetracked by dust, water vapour, aerosols or high concentration of CO. For detection of CO, existing standards recommend the use of electrochemical sensors. Methods: The article describes the technical parameters of the most appropriate electrochemical sensors for monitoring of CO. These are electrolytic, based on acidic electrolyte and metal oxide semiconductors, namely Nap-508 (505) and TGS2442. The principles of operation and recommended circuit connection are suitably described in the article. The sensors are specially designed for use with gas fire detectors and were tested in accordance with requirements for fire detectors. It is noted that metal-oxide sensors have the most acceptable performance characteristics, across the broadest temperature range, long period of validity and absence of aggressive substances in composite elements. Among its disadvantages is a relatively high power consumption ~ 15 mW. Conclusions: Examined prospects for the development and production of metal oxide semiconductor sensors. It is indicated that the use of micro and nanotechnology in the manufacture of sensors will solve the problem of reducing energy consumption to a level sufficient for the production of self-contained smoke detectors powered by batteries. At present, Figaro has developed a sensor TGS8410 with an average power consumption of 0.087 mW.
Cel: Celem artykułu jest udzielenie wskazówek konstruktorom czujek pożarowych odnośnie wyboru czujników tlenku węgla w komorze wielosensorowej czujki pożarowej. W monografiach poświęconych tej tematyce znaleźć można wiele czujników nadających się do analizy CO. Każdy czujnik ma swoje zalety jak i wady. W związku z tym wybór odpowiedniego czujnika jest dość trudny. Autorzy, na bazie wieloletniego doświadczenia w projektowaniu i produkcji przyrządów do analizy gazowej i czujek pożarowych, zaproponowali najbardziej adekwatne rozwiązania. Wprowadzenie: Obecnie do wykrywania pożarów bardzo często wykorzystywane są czujki dymu (zwykle z czujnikiem temperatury). Mają one jednak wiele wad – nie działają w sposób selektywny na dym (rozpoznają jako dym aerozole, parę wodną, parę powstającą przy gotowaniu, kurz). Czujka pożarowa CO nie ma takich wad, ponieważ reaguje wyłącznie na CO. Dlatego powstało wiele perspektywicznych norm europejskich i standardów międzynarodowych, które do wykrywania pożarów przewidują analizę CO. Oczywiście, duże stężenia CO mogą powstać w pomieszczeniach, w których pali się papierosy, również tam gdzie znajdują się urządzenia ciepłownicze na paliwo stałe lub gazowe, w garażach i parkingach podziemnych. Wielosensorowe czujki, wykorzystujące dwie komory wykrywania pożaru – CO i dymu, rekompensują wady każdej z tych komór. Przy jednoczesnej aktywacji obu, można z pewnością stwierdzić, że mamy do czynienia z pożarem we wczesnym stadium rozwoju, a nie z kurzem, parą wodną, aerozolem lub po prostu dużym stężeniem CO. Do wykrywania CO odpowiednie nomy rekomendują użycie czujników elektrochemicznych. Metody: W artykule opisano parametry techniczne najbardziej odpowiednich do kontroli CO czujników elektrochemicznych na bazie elektrolitów kwasowych i półprzewodników tlenkowych, a dokładnie Nap-508 (505) и TGS2442. Opisano również zasady pracy i zalecane schematy połączeń. Czujniki te były opracowywane specjalnie do wykorzystania w pożarniczych czujkach gazu i przeszły wszystkie badania zgodnie z wymogami dla czujek pożarniczych. Zaznaczono, że czujniki tlenkowe mają najbardziej akceptowalne charakterystyki eksploatacyjne – najszerszy zakres temperatur, długi termin ważności, brak w składzie elementów środowiska agresywnego. Do ich wad należy względnie duże zużycie energii ~ 15 mW. Wnioski: Rozpatrzono perspektywy rozwoju technologii produkcji półprzewodnikowych czujników tlenkowych. Wskazano, że zastosowanie mikro- i nanotechnologii przy produkcji tych czujników rozwiązuje kwestię zmniejszenia zużycia energii do poziomu dostatecznego do przygotowania autonomicznych czujek pożarniczych zasilanych baterią. Już teraz firma Figaro opracowała czujkę TGS8410 za średnim zużyciem prądu 0,087 mW.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 4; 107-122
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjne technologie mające zastosowanie w obszarze wykrywania zagrożenia pożarowego
Autorzy:
Turkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/373522.pdf
Data publikacji:
2007
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
czujka przeciwpożarowa
światłowody
system wykrywania pożarów
czujniki gazów
sensor
zagrożenie pożarowe
fire detector
fiber
fire detection systems
gas sensors
fire hazard
Opis:
W referacie przybliżono najbardziej obiecujące rozwiązania układów detekcyjnych, których zastosowanie w obszarze wykrywania zagrożenia pożarowego stało się możliwe, głównie dzięki rozwojowi współczesnej nanotechnologii i optoelektroniki.
This article presents the most promising sensors utilized in fire detection applications, which can be nowadays used thanks to continuous progress made in nanotechnology and optoelectronic domain.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2007, 1; 283-298
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie substancji ropopochodnych za pomocą chromatografii gazowej połączonej z detektorem płomieniowo-jonizacyjnym
Determination of total petroleum hydrocarbons (TPH) by gas chromatography with flame ionization detection method
Autorzy:
Poluszyńska, J.
Bożym, M.
Sławińska, I.
Dwojak, J.
Powiązania:
https://bibliotekanauki.pl/articles/392476.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
węglowodór ropopochodny
zanieczyszczenie środowiska
oznaczanie ilościowe
chromatografia gazowa
detektor płomieniowo-jonizacyjny
petroleum hydrocarbon
environment pollution
quantitative determination
gas chromatography
flame ionization detector
Opis:
Do oznaczania ropopochodnych (TPH) w próbkach środowiskowych najczęściej wykorzystuje się metodę chromatografii gazowej (GC) oraz spektrometrię w podczerwieni (IR). Metoda GC-FID jest preferowaną w oznaczeniach węglowodorów ropopochodnych (TPH). W pracy wykorzystano metodę chromatografii gazowej z detektorem jonizacji płomieniowej (GC-FID) w celu określenia zakresu metody, granicy wykrywalności (LOD) i oznaczalności (LOQ), wyznaczenia krzywych kalibracyjnych oraz odzysku dla próbek wzbogaconych. Dodatkowo zbadano dwie metody ekstrakcji: na zimno (20°C) i na ciepło (40°C). Dla obu metod obliczono stopnie odzysku na dwóch poziomach stężeń (2 i 20 mg/ml). Wyniki uzyskane z analizy odzysku wskazują, że zależy on od temperatury ekstrakcji. Najwyższe stopnie odzysku uzyskano dla metody na ciepło (40°C). Opracowana metoda GC-FID nadaje się do oznaczania TPH (C10-C40) w próbkach wody.
Two main methods are usually used to determined TPH in environmental samples: gas chromatography (GC) and infrared spectrometry (IR). However GC-FID is preferred method to TPH determination. In this work gas chromatography with flame ionization detection (GC-FID) was used to quantify of method range, to determine the limit of detection (LOD) and the limit of quantification (LOQ), to prepare a calibration curves, to determine the TPH in water samples and recovery test in contaminated samples. Two extraction methods were also researched in this paper: cold method (20°C) and warm method (40°C). The recovery range was calculated for these two types of extractions. The results indicate that the recovery of TPH is dependent on the temperature of the extraction. The highest recoveries of TPH were obtained with warm method (40°C). The GC-FID method, used in this work, is an useful technique for the determination of TPH (C10-C40) in water samples.
Źródło:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych; 2009, R. 2, nr 3, 3; 131-140
1899-3230
Pojawia się w:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie metodyki oznaczania polichlorowanych bifenyli w próbkach gleb
Development of a methodology for the determination of polychlorinated biphenyls in soil samples
Autorzy:
Wojtowicz, Katarzyna
Jakubowicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1835079.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
polichlorowane bifenyle
chromatografia gazowa
detektor wychwytu elektonów (ECD)
ekstrakcja
ekstrakcja do fazy stałej (SPE)
polychlorinated biphenyls
gas chromatography
electron capture detector (ECD)
extraction
solid-phase extraction (SPE)
Opis:
W artykule przedstawione zostały zagadnienia związane z opracowaniem metodyki chromatograficznego oznaczania polichlorowanych bifenyli w próbkach gleb. Do tego celu stosowano chromatograf gazowy wyposażony w detektor wychwytu elektronów (GC-ECD) firmy Perkin Elmer. W ramach prowadzonych badań określono optymalne parametry pracy chromatografu, takie jak: temperatura inżektora, temperatura detektora ECD, przebieg temperaturowy pieca w trakcie analizy chromatograficznej, czas analizy oraz dobrano kolumnę chromatograficzną umożliwiającą selektywny rozdział analitów. Następnie przeprowadzono kalibrację układu chromatograficznego i walidację metody analitycznej oznaczania polichlorowanych bifenyli, stosując roztwory wzorcowe firmy Supelco i Sigma-Aldrich o numerach odpowiednio 47330-U oraz 36989. Sporządzono krzywe kalibracyjne dla każdego z badanych kongenerów PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) w dwóch zakresach stężeń. Walidacja metody analitycznej obejmowała wyznaczenie liniowości, odchylenia standardowego, względnego odchylenia standardowego, granicy wykrywalności (LOD) i granicy oznaczalności (LOQ) wyżej wymienionych kongenerów PCB. W tym celu opracowania metodyki przygotowania próbek gleb do analizy chromatograficznej przetestowano układ pod kątem doboru metody ekstrakcji (ekstrakcja rozpuszczalnikiem wspomagana wytrząsaniem, ekstrakcja z wykorzystaniem ultradźwięków i ekstrakcja w aparacie Soxhleta), doboru rozpuszczalnika/układu rozpuszczalników (n-heksan, mieszanina n-heksanu i dichlorometanu w stosunku 1:1) oraz doboru materiału sorpcyjnego w etapie ekstrakcji do fazy stałej SPE (kolumienki do zadań specjalnych oraz kolumienki z wypełnieniem Florisil). Do badań modelowych wykorzystano próbki gleb zanieczyszczone roztworem wzorcowym firmy Supelco o numerze 47330-U. Dla wszystkich kombinacji wyżej wymienionych warunków przygotowania próbki do analizy chromatograficznej obliczono stopień odzysku poszczególnych analitów. Na podstawie analiz chromatograficznych i stopni odzysku wytypowano najbardziej optymalną metodykę przygotowania próbek gleb do analizy chromatograficznej pod kątem oznaczania polichlorowanych bifenyli. Opracowaną metodykę oznaczania polichlorowanych bifenyli w próbkach gleb przetestowano na rzeczywistych próbkach gleb skażonych zestarzałym olejem transformatorowym pobranych z terenów południowo-wschodniej Polski. Procedura analityczna oznaczania PCB w próbkach gleby obejmowała: wstępne przygotowanie próbek (suszenie, mielenie i homogenizacja), izolację analitów z matrycy próbki (ekstrakcja rozpuszczalnikiem wspomagana wytrząsaniem z zastosowaniem mieszaniny rozpuszczalników n-heksan:dichlorometan w stosunku 1:1), oczyszczanie próbki z substancji przeszkadzających (zestaw dwóch kolumienek do ekstrakcji SPE: Silica gel nr 7086-03 i PCB-A nr 7511-04 firmy Bakerbond), analizę chromatograficzną. Zastosowanie wyżej wymienionych technik analitycznych pozwoliło na uzyskanie informacji na temat zawartości badanych kongenerów polichlorowanych bifenyli w próbkach gleb.
The article presents issues related to the development of the chromatographic methodology for determining polychlorinated biphenyls in soil samples. For this purpose, a gas chromatograph equipped with an electron capture detector (GC-ECD) from Perkin Elmer was used. As part of the research, optimal chromatograph parameters were determined, such as injector temperature, ECD detector temperature, oven temperature course during chromatographic analysis, time of analysis and a chromatographic column allowing selective separation of analytes. Then, the chromatographic system was calibrated and the analytical method for polychlorinated biphenyls determination was validated, based on the Supelco and Sigma-Aldrich reference solutions with numbers 47330-U and 36989, respectively. Calibration curves for each of the congeners tested were PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) in two concentration ranges. The validation of the analytical method included the determination of linearity, standard deviation, relative standard deviation, detection limit (LOD) and limit of quantification (LOQ) of the above PCB congeners. To this end, the development of the methodology for preparing soil samples for chromatographic analysis has been tested for the selection of the extraction method (extraction with solvent assisted by shaking, extraction with ultrasonic assisted solvent, solvent extraction in a Soxhlet apparatus), solvent/solvent system selection (n- hexane, a mixture of n-hexane and dichloromethane in a 1:1 ratio) and selection of sorption material in the SPE solid phase extraction stage (columns for special tasks, Florisil packed columns). Model samples used soil contaminated with the Supelco standard solution number 47330-U. For all the combinations of the above-mentioned conditions of preparing the sample for chromatographic analysis, the recovery rate of individual analytes was calculated. On the basis of chromatographic analyses and recovery levels, the most optimal methodology for preparing soil samples for chromatographic analysis was selected for the determination of polychlorinated biphenyls. The developed methodology for the determination of polychlorinated biphenyls in soil samples was tested on real samples of soils contaminated with aged transformer oil taken from the areas of south-eastern Poland. The analytical procedure for the determination of PCBs in soil samples included: initial sample preparation (drying, milling, homogenization), isolation of analytes from the sample matrix (solvent extraction assisted by shaking with a 1:1 mixture of solvents n-hexane: dichloromethane), sample purification from disturbing substances (a set of two columns for SPE extraction: Silica gel No. 7086-03 and PCB-A No. 7511-04 from Bakerbond), chromatographic analysis. The application of the above-mentioned analytical techniques allowed to obtain information on the content of polychlorinated biphenyls investigated in soils samples.
Źródło:
Nafta-Gaz; 2019, 75, 7; 420-429
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrosystemy i Sensory
Microsystems and Sensors
Autorzy:
Maksymowicz, L.
Nowak, S.
Leja, E.
Pisarkiewicz, T.
Stapiński, T.
Zakrzewska, T.
Powiązania:
https://bibliotekanauki.pl/articles/154228.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
optoelectronics
semiconducting gas sensors
modified multicrystalline silicon structures as a light detector thin film technology
vacuum equipment
magnetic tunnel junctions
magnetic random access memory MRAM
radio frequency identification (RFID)
mine underground environment
ceramic microsystem
microfluidics
LTCC
photoimageable thick-films
Opis:
Prezentowana praca zawiera wybrane zagadnienia naukowe związane z rozwijaną od lat tematyką w Katedrze Elektroniki dotyczącą mikrosystemów i sensorów. Autorzy odnieśli się do szczegółowych zagadnień takich jak: półprzewodnikowe sensory gazu, zmodyfikowane struktury multikrystalicznego krzemu jako detektor światła, cienkowarstwowe magnetyczne złącza tunelowe i ich zastosowania. Opisano również opracowywane technologie i konstrukcje urządzeń próżniowych do wytwarzania cienkich warstw i układów wielowarstwowych. Zaprezentowano przykładowe zastosowania techniki sensorowej i radiowej identyfikacji obiektów RFID w sektorze energetycznym. Przedstawiono zastosowanie dwóch zaawansowanych technologii ceramicznych - współwypalanych folii ceramicznych LTCC oraz warstw grubych fotoformowalnych do wytworzenia elementów składowych mikrosystemu ceramicznego dla chromatografii - mikrokanału oraz płomieniowego detektora jonizacyjnego.
The work deals with scientific problems connected with microsystems and sensor technology developed in Department of Electronics. The authors present their achievements such as semiconductor gas sensors, microcrystalline silicon light detectors, thin film magnetic tunnel junctions and their applications. Some vacuum systems for films and multilayers depositions were also designed and constructed by our scientific staff. The sensor and radio frequency identification (RFID) applications were also described. Two advanced ceramic technologies (photoimageable thick films and LTCC) has been successfully combined to obtain microfluidic structures - the microchannel and the flame ionisation detector which are intended to use in a simple, portable ceramic microsystem for chromatography.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 3, 3; 63-69
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies