Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "earthquake resistance" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Modal analysis of real timber frame houses with different insulation materials
Autorzy:
Szczepański, M.
Migda, W.
Jankowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/101994.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
timber frame house
earthquake resistance
dynamic
numerical model
modal analysis
Opis:
The aim of this article is to present the results of a numerical modal analysis of two actual structures of timber frame buildings and the different behaviour due to the used insulation material. One model of the timber structure was filled with mineral wool, while the other with polyurethane foam. During the modal analysis, eigenvalues for both models have been determined. The results of the analysis clearly show the increase of stiffness and damping properties of skeletal constructions achieved by the use of polyurethane foam as the skeleton filling. The numerical model was based on prior experimental test on real scale single frame elements, therefore the result can be assumed to be adequate.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 31; 215-221
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Timber-frame house resistant to dynamic loads - analysis of wall panel filled with polyurethane foam
Autorzy:
Szczepański, M.
Migda, W.
Jankowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/127669.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
timber frame house
earthquake resistance
dynamic loads
numerical model
konstrukcje drewniane szkieletowe
odporność na ruchy tektoniczne
obciążenia dynamiczne
model numeryczny
Opis:
The present study shows the experimentally and numerically determined response of a single timber-frame house wall panel filled with polyurethane (PU) foam under dynamic loads. The harmonic tests were conducted for the following frequencies: 0.5 Hz, 1.0 Hz, 2.0 Hz and 5.0 Hz for various values of the specified displacement. Based on the results of the comparison between the experimental tests and the numerical analyses, the numerical model has been verified to be correct. The model can be used in further analyses so as to investigate the behaviour of the whole building under dynamic loads, including seismic and paraseismic excitations. Using such a numerical model, it will be possible to evaluate the improvement in resistance against dynamic loads for the case when PU foam is used instead of mineral wool.
Źródło:
Vibrations in Physical Systems; 2016, 27; 347-354
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismicity in Nigeria : the need for earthquake-resistant structures
Aktywność sejsmiczna w Nigerii : potrzeby związane z konstrukcjami odpornymi na trzęsienia ziemi
Autorzy:
Shiwua, A. J.
Powiązania:
https://bibliotekanauki.pl/articles/2068366.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
aktywność sejsmiczna
obciążenie sejsmiczne
trzęsienie ziemi
konstrukcja budowlana
odporność sejsmiczna
Nigeria
seismic activity
seismic load
earthquake
building construction
seismic resistance
Opis:
Nigeria has experienced pockets of tremors of magnitudes ranging from 4.3 to 4.5, even though it is not situated where major seismic activities are observed in the world. In 2000 an earthquake with body wave magnitude of 4.4 occurred in Nigeria and was recorded by some agencies like the International Seismological Centre (ISC). Similarly, the vibrations of the September 11, 2009 event with magnitude 4.4 and epicenter at Allada, Benin Republic, almost 130 km west of Lagos, Nigeria, was felt in parts of Ibadan and Ogun State, south-western Nigeria. Most of the previous tremors occurred in south-western Nigeria where a major fault (the Ifewara-Zungeru fault), is believed to exist. It is difficult to overlook the incidence of earth tremors in the country because recurring tremors could be a build-up to a major earthquake. Despite these events, most buildings in Nigeria are designed without incorporating the effect of seismic load. This paper seeks to reiterate why it is imperative to design earthquake-resistant structures in Nigeria bearing in mind the obvious knowledge of Earth’s dynamism and the country’s history of the earthquake activities.
Nigeria doświadczyła wstrząsów o sile od 4,3 do 4,5 mimo tego, że nie jest położona w obszarze, w którym obserwuje się aktywność sejsmiczną. W 2000 roku w Nigerii miało miejsce trzęsienie ziemi o sile 4,4 i zostało zarejestrowane przez niektóre agencje badawcze, np. Międzynarodowe Centrum Sejsmologiczne (ISC). Podobnie wstrząsy z dnia 11 września 2009 roku o sile 4,4 z epicentrum w Allada (Republika Beninu), położonej około 130 km na zachód od Lagos (Nigeria) były odczuwalne w części Ibaan i Ogun (południowo-zachodnia Nigeria). Większość wcześniejszych wstrząsów miała miejsce w południowo-zachodniej Nigerii, gdzie występuje poważny defekt. Trudno przeoczyć występowanie wstrząsów w Nigerii, które mogą być zapowiedzią większego trzęsienia ziemi. Pomimo tego budynki w Nigerii nie są projektowane z uwzględnieniem oddziaływań sejsmicznych. Niniejsza praca ma na celu przypomnienie o konieczności projektowania konstrukcji odpornych na trzęsienia ziemi z uwzględnieniem wiedzy o dynamice ziemi oraz historii trzęsień ziemi.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2013, 19 (169); 171--178
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies