Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bridge voltage" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Fault diagnosis of T-type three-level inverter based on bridge voltages
Autorzy:
Chen, Danjiang
Liu, Yutian
Zhang, Shaozhong
Powiązania:
https://bibliotekanauki.pl/articles/1841372.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bridge voltage
fault diagnosis
fault signal
open-circuit fault
T-type three-level inverter
napięcie mostka
błędna diagnoza
sygnał błędu
błąd obwodu otwartego
falownik trójpoziomowy typu T
Opis:
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, anda diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when anopen-circuit fault of the device occurred, and the effect on the circuit switching states andthe bridge voltages were analyzed. Then comprehensively considered the bridge voltages,and proposed a fault diagnosis method for a T-type three-level inverter based on specificfault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of theinverter device, and has the advantage of being easy to implement.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 73-87
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ideal rectifier bridge converting the harvested energy of vibrations into electric energy to power an mr damper
Autorzy:
Sapiński, Bogdan
Jastrzębski, Łukasz
Kozieł, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/1837924.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
energy harvesting
rectifier bridge
voltage
current
MR damper
Opis:
The newly developed ideal rectifier bridge equipped with four N-type MOSFETs and two rail-to-rail operational amplifiers is a part of a typical energy harvesting conditioning circuit responsible for the rectification stage in the system of converting the energy harvested from vibrations into electrical energy to power the MR damper. The only energy loss in the bridge is caused by the voltage loss in transistors’ channels. The first sections of the work summarises the structural design of the bridge, the simulation procedure under the RL load and by sine voltage inputs with predetermined frequency and amplitude range, and benchmarks the results against those obtained for the conventional bridge based on Schottky diodes. In the second section, the PCB prototype of the bridge is analysed, and measurement data are compiled. The third section reports on the laboratory testing of the developed bridge converting the harvested energy in an MR damper-based vibration reduction system.
Źródło:
Acta Mechanica et Automatica; 2020, 14, 4; 198-205
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DC-link voltage balancing in cascaded H-Bridge converters
Autorzy:
Lewicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/141491.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascaded H-Bridge converter
DC-link voltage balancing
space-vector pulse width modulation
Opis:
In this paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches on proposed control strategy are presented in the paper.
Źródło:
Archives of Electrical Engineering; 2014, 63, 3; 439-455
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
Autorzy:
Lewicki, A.
Morawiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/200099.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascade H-bridge inverter
DC-link voltage control
space vector modulation
mostek H
sterowanie napięciem
modulacja
Opis:
A control strategy of DC-link voltages for a seven-level cascaded H-bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by an appropriate selection of H-bridges and control of their duty cycles in space-vector modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the SVM strategy makes it possible to generate the output voltage vector properly also in the case where the DC-link voltages are not balanced. The results of simulation and experimental investigations are presented in the paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 619-628
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary stosunku impedancji wzorcowych w układzie komparatora z zastosowaniem metody przestawienia
Comparisons of impedances with the complex voltage ratio measurement
Autorzy:
Kontorski, K.
Powiązania:
https://bibliotekanauki.pl/articles/158545.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stosunek impedancji
impedancje pasożytnicze
zespolony stosunek napięć
próbkujący moduł pomiarowy
mostek transformatorowy
impedance ratio
stray
parasitic impedances
complex voltage ratio
sampling voltmeter
transformer bridge
Opis:
W artykule przedstawiona jest metoda pomiaru stosunku impedancji dwuportowych, współosiowych w zakresie (10 – 100) kΩ typu R-R, C-C, a także R-C z wykorzystaniem cyfrowego modułu pomiarowego. Badania miały na celu weryfikację dokładności nowego układu komparatora. Otrzymane wyniki pomiarów porównano z wynikami otrzymanymi klasycznym mostkiem transformatorowym. Dokonano analizy błędów układu i wskazano możliwości ich poprawy.
In the paper there is presented a new scheme of an unbalanced impedance comparator for measuring two terminal pair, coaxial impedance ratio with a complex voltage ratio (CVR). In the introduction there is given a description of classical and digital comparators. Fig. 1 shows the schematic diagram of a comparator. It contains a digital generator G, digital sampling voltmeter channels V1, V2, impedances ZX, ZN whose ratio is to be determined and reed relays K1 and K2. Parasitic impedances in the comparator are denoted as ZD [2]. The next section presents mathematical explanation how the impedance ratio is achieved using UV1', UV2', UV1'', UV2'' voltages derived by DFT from the gathered probes. The expression (7) is true if the generator voltage between measurements is constant. The experimental results of comparison of 6 impedances: 4 resistive type impedances of the nominal values of 10 kΩ (R3, R4), 100 kΩ (R1, R2) and two capacitive impedances of the nominal values of 3 nF (C1, C2) are given in Table 1. The left column presents the type of comparison. In the middle one there are given the results obtained by the comparator and in the right - the real parts of the impedance ratio obtained from a transformer bridge. Fig. 2 shows the experimental results to check if there is really the same voltage in the time of measurement. Summing up, these are the preliminary results and the comparator has to be investigated under other metrological conditions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 4, 4; 319-322
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary komparatorowe stosunku impedancji wzorcowych różnego typu
Measurements of different type standard impedance ratio with digital comparator
Autorzy:
Kontorski, K.
Powiązania:
https://bibliotekanauki.pl/articles/158540.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stosunek impedancji
impedancje pasożytnicze
zespolony stosunek napięć
mostek transformatorowy
próbkujący moduł pomiarowy
impedance ratio
stray
parasitic impedances
complex voltage ratio
sampling voltmeter
transformer bridge
Opis:
W artykule przedstawiony jest układ komparatora do wyznaczania stosunku impedancji dwuportowych, współosiowych w zakresie (10 – 100) kΩ, typu R-R, C-C, a także R-C. Główne elementy układu to generator, transformator pomiarowy i cyfrowy moduł pomiarowy. Przeprowadzono badania w celu pewnego porównania wyników otrzymanych komparatorem z tymi otrzymanymi klasycznym mostkiem transformatorowym. Dokonano analizy błędów występujących w systemie pomiarowym.
In the paper a comparator circuit which measures two terminal-pair impedance ratio is presented. The system is able to compare impedances of R-C type elements but with indirect comparison it is possible to achieve impedance ratio of R-R and C-C type elements. The first section describes the principle of operation of the impedance bridge and comparator. The system setup and the measurement method are presented in the second section. In Fig. 1 there are shown: a digital generator G, a measurement transformer Tr, the compared impedances ZX, ZN, a digital sampling voltmeter with channels V1, V2 and a buffer amplifier B. Stray impedances are depicted as ZI and they affect mostly the unbalance voltage [2]. The CVR (complex voltage ratio) is gathered when the secondary voltages are in phase and when they are in reversed phase (180˚). Equation (8) describes the relation between the measured CVRS and the impedance ratio. Table 1 contains the measurement results of the CVR at the transformer output in the circuit with different impedances. It is assumed that the voltage ratios at the transformer output are equal to 1 and -1, respectively. The experimental results are listed in Table 2. There were compared two standard resistors (R1, R2) of nominal values equal to 100 kΩ, two resistors (R3, R4) of 10 kΩ and two capacitors (C1, C2) of 3 nF. The resulting indirect ratio of C1, C2 and R1, R2 is compared with the direct result from a transformer bridge. The results are contained in the range of ± 5 ppm. The fifth section describes shortly sources of the uncertainty in the system.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 1, 1; 6-8
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Co-design of a low-power RF receiver and piezoelectric energy harvesting power supply for a Wireless Sensor Node
Autorzy:
Mancelos, N
Correia, J
Oliveira, J. P.
Oliveira, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/398018.pdf
Data publikacji:
2014
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
CMOS RF analog front-end
low-voltage wideband balun LNA
passive mixer
piezoelectric energy harvesting
active full bridge rectifier
LDO regulator
układ analogowy CMOS
balun szerokopasmowy
mikser pasywny
energia piezoelektryczna
prostownik aktywny
prostownik mostkowy
regulator LDO
Opis:
A low-voltage RF CMOS receiver front-end and an energy harvesting power circuit for a piezoelectric source are presented as a co-designed solution for a Wireless Sensor Node. A MOSFET-only Wideband balun LNA with noise cancelling and a 0.6 V supply voltage is designed in conjunction with a passive mixer. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver front-end reaches a total voltage conversion gain of 31 dB, a 0.1-5.2 GHZ bandwidth, an IIP3 value of -1.35 dBm, and a noise figure inferior to 9 dB. The total power consumption is 1.95 mW. The energy harvesting power circuit consists of an active full bridge cross-coupled rectifier followed by a low-dropout (LDO) regulator, and it is able to guarantee a power output of 6 mW with a regulated output voltage of 0.6 V, for typical vibration patterns.
Źródło:
International Journal of Microelectronics and Computer Science; 2014, 5, 4; 136-143
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies