Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "43.66.Fe" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The Use of the Phase Locking Information in the Human Auditory System for Frequencies Above 5 kHz
Autorzy:
Sęk, A.
Bukała, M.
Powiązania:
https://bibliotekanauki.pl/articles/1400102.pdf
Data publikacji:
2013-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.66.Fe
43.66.Hg
Opis:
Accurate allocation of neural impulses to the same phase (i.e. phase locking) in the auditory system, ceases for frequencies above 5 kHz. However, some recent works suggest that it may have a much higher value. A discrimination of harmonic complex and inharmonic complex sound, formed using sound harmonic complex, in which all components were shifted towards higher frequency by the same number in hertzs, was analyzed. Fundamental frequency was $F_0$=1 kHz and signals were bandpass filtered by a fixed filter center frequency of which was $11F_0$ and bandwidth $5F_0$. Discrimination threshold was $\Delta F=0.089F_0$ for 10 normal-hearing subjects. However, replacing the sinusoidal components with the noise bands brought about a significant increase in thresholds. The largest increase was observed for 700 Hz bandwidth. The replacement of sinusoidal components with noisebands reduces information conveyed by phase locking. The differences in excitation pattern for harmonic complex and inharmonic complex signals, for the average threshold, did not exceed 0.7 dB. Therefore they could not be a useful cue for harmonic complex and inharmonic complex discrimination. A simplified model of phase locking showed that the substitution of sinusoids with bands of noise significantly reduced number of intervals between successive neural spikes corresponding to the virtual pitch of harmonic complex and inharmonic complex sounds. This degradation of discrimination suggests that the main source of information about the pitch of harmonic complex and inharmonic complex, especially for sinusoidal components, was the phase locking.
Źródło:
Acta Physica Polonica A; 2013, 123, 6; 1106-1113
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency Discrimination for Amplitude Modulated Sinusoidal Signals at High Carrier Frequencies
Autorzy:
Sęk, A.
Kordus, M.
Powiązania:
https://bibliotekanauki.pl/articles/1359956.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.66.Fe
43.66.Hg
Opis:
The current study is a continuation of experiments presented by Sęk and Bukała (Acta Physica Polonica A 123, 1106 (2013)). The purpose of the present study was to investigate frequency discrimination of amplitude modulated high frequency carriers. Using 2AFC procedure, the subjects were presented with two observation intervals of which the first interval contained four pulses of the same high frequency signal (called SSSS), while in the second interval (called SHSH) the second and fourth pulses had higher frequencies values (i.e. shifted upwards by Δ f). The carrier frequency (in S pulses) was fixed and equal to 10 kHz. Modulation rates were equal to 100, 200, 337, 500, 600, 733, and 800 Hz. The value of the modulation rate was limited to keep all components of the sinusoidal modulation within one auditory filter (17% of the center frequency) centered at the carrier frequency. Two different types of modulation were used: a simple sinusoidal modulation with the modulation depth m set to 100%, and a logarithmic modulation with the modulation depth m set to 50 dB. Results indicate a strong relationship between frequency discrimination threshold and modulation type. The thresholds are significantly higher for logarithmic modulation in comparison to sinusoidal modulation. Amplitude modulation as well as logarithmic modulation applied to the high frequency carrier cause significant increase in the frequency discrimination threshold. For high frequency sinusoidal signal carriers (i.e. close to 10 kHz), frequency discrimination thresholds do not depend on amplitude modulation rates up to about 800 Hz. In general, the excitation pattern mechanism was a primary cue enabling frequency discrimination of modulated and unmodulated signals to compare with the mechanism based on the temporal fine structure. However, the excitation pattern was not the only mechanism responsible for the frequency discrimination.
Źródło:
Acta Physica Polonica A; 2014, 125, 4A; A-149-A-154
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies