Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "07.85.Fv" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Development of a Soft X-ray Microprobe for Radiobiology Studies
Autorzy:
Appuhamilage, I.
Adjei, D.
Alatabi, S.
Alnaimi, R.
Michette, A.
Pfauntsch, S.
Powiązania:
https://bibliotekanauki.pl/articles/1197646.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.50.+h
07.85.Fv
Opis:
The King's College London (KCL) first X-ray microprobe (MKI) and the third generation microfocus X-ray sources (MKIII) are intended to be used for various applications including the study of physical and biological interactions at the atomic and molecular scales. The microfocus ultra-soft X-ray sources (MKI and MKIII) with interchangeable targets will provide a superior spatial resolution (a focal spot a few hundreds of nanometres in diameter can be achieved) and the control of the dose delivered to irradiated cells. This will require characterization of the spectra and intensities of the source, measurements of the focus intensities and spot sizes of suitable X-ray optics such as zone plates, grazing incidence microstructured optical arrays and multilayer mirrors.
Źródło:
Acta Physica Polonica A; 2014, 125, 4; 882-885
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Asymmetry of 1 nm XRD reflection and measurement of illite crystallinity
Autorzy:
Wang, Hejing
Zhou, Jian
Powiązania:
https://bibliotekanauki.pl/articles/1112783.pdf
Data publikacji:
2016-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.85.Nc
07.85.Jy
07.85.Fv
Opis:
Theoretically the X-ray emission is subjected to the Gaussian distribution and is symmetric. An X-ray diffraction peak should be symmetric, too. However all illite 1 nm (interplanar distance) peaks used for measurement of illite crystallinity (IC) are practically asymmetric. Our experimental results prove that any X-ray diffraction peak in low diffraction angle segment appears asymmetric if the diffractometer is running with a slit-fixed system. However, if the diffractometer is running with an auto-adjustable-slit system and the illumination length is fixed, the X-ray diffraction peak in low diffraction angle segment is symmetric. Those peaks derived from synchrotron radiation are symmetric in all angle ranges. The asymmetric degree (AsD) of a X-ray diffraction peak is subjected to the ratio of integrated intensities on lower and higher diffraction angle sides which are related to the X-ray illuminating length (area) on the sample. From the expression of illuminating length it is derived that with increasing diffraction angle the illuminating length decreases and therefore a X-ray diffraction peak is always asymmetric. The relationship between AsD and IC can be expressed as AsD = 0.239IC + 0.999, When illite/smectite mixed-layer phase presents the asymmetry of the illite 1 nm X-ray diffraction peak will be obviously higher than usual case and induces unusually larger IC value.
Źródło:
Acta Physica Polonica A; 2016, 130, 4; 886-888
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monte Carlo Analysis of the Influence of Different Packaging on MOSFET Energy Response to X-rays and Gamma Radiation
Autorzy:
Stanković, S.
Ilić, R.
Živanović, M.
Janković, K.
Lončar, B.
Powiązania:
https://bibliotekanauki.pl/articles/1418114.pdf
Data publikacji:
2012-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.85.Fv
85.30.Tv
87.55.kh
Opis:
Radiation sensing MOSFETs have found numerous applications as detectors or device components in radiation fields used in nuclear industry, medical applications and space research. Monte Carlo simulations of MOSFET energy response to X-ray and gamma radiation for different packaging were performed. The photon transport Monte Carlo software FOTELP-2K10 has been adapted to obtain the energy deposited in MOSFET structure with microscopic dimensions. In this work the ratio between values of total energy deposited in the sensitive volume (thick $SiO_2$ layer) for cases of MOSFET structure with and without package lid is presented. For this purpose is defined the shielding energy dependence factor (SDEF), and gave its value for kovar and Ti-24Al-11Nb and Ti-13Nb-13Zr alloys as lid materials.
Źródło:
Acta Physica Polonica A; 2012, 122, 4; 655-658
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrotron Radiation in Biology and Medicine
Autorzy:
Pełka, J.
Powiązania:
https://bibliotekanauki.pl/articles/1812240.pdf
Data publikacji:
2008-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.-s
87.59.-e
07.85.Fv
07.90.+c
Opis:
This work is focused on a present status of synchrotron radiation X-ray applications in medicine and biology to imaging, diagnostics, and radiotherapy. Properties of X-ray beams generated by synchrotron sources are compared with radiation produced by classical laboratory X-ray tubes. A list of operating and planned synchrotron facilities applicable to biomedical purposes is given, together with their basic characteristics. A concise overview of typical X-ray synchrotron techniques in biology and medicine is carried out with discussion of their specific properties and examples of typical results.
Źródło:
Acta Physica Polonica A; 2008, 114, 2; 309-329
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Rays Response of Diamond Detectors Constructed Using Diamond Layers Produced by Low Power Microwave Chemical Vapor Deposition Reactor
Autorzy:
Kordyasz, A.
Bednarek, A.
Kowalczyk, M.
Tarasiuk, J.
Kulczycka, E.
Teodorczyk, M.
Gajewski, M.
Kordyasz, Ł.
Rowiński, O.
Lamparski, K.
Karwański, Ł.
Lipczewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/1402641.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.75.-d
81.15.Gh
29.40.Vj
07.85.Fv
Opis:
The low power reactor for microwave chemical vapor deposition process is described. The rotating Mo holder of 12 mm diameter and 6 mm height with the diamond substrate was heated by 2.45 GHz microwaves to temperature about 800°C in the range of (1.5-7)% $CH_{4}//H_{2}$ mixture to create plasma at pressure 70 Tr. Stabilization of the holder temperature was performed by optical observation of radiation from the holder followed by adjusting of the magnetron power. Diamond detectors are produced using microwave chemical vapor deposition process grown on single crystal diamond high pressure high temperature Sumimoto substrates, [100] oriented. The response of diamond detectors for X-rays has been measured in the current mode using medical X-rays tube. The linear response of the diamond detector current versus X-ray tube current (dose) is presented.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1555-1559
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of New Structure for Silicon Carbide X-Ray Detector by Method Monte Carlo
Autorzy:
Stankovic, S.
Ilic, R.
Jankovic, K.
Vasic-Milovanovic, A.
Loncar, B.
Powiązania:
https://bibliotekanauki.pl/articles/1503337.pdf
Data publikacji:
2011-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.85.Fv
87.55.kh
85.30.Kk
61.72.uf
77.84.Bw
Opis:
This work presents a characterization of radiation absorption properties of silicon carbide (SiC) as semiconductor for the realization of detectors for X-rays. SiC detectors can potentially reach superior performance with respect to all the other semiconductors presently employed in hazardous environments in nuclear and space science and technology. Physics and numerical modeling of photons transport through SiC detector is incorporated in non-destructive Monte Carlo method for determining the energy deposited and dose distribution. The Monte Carlo code has been adopted for numerical simulations for different detector conditions and configurations. The X-ray characterization of new SiC structures originates the improving of design of these detector systems.
Źródło:
Acta Physica Polonica A; 2011, 120, 2; 252-255
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prompt-Gamma Monitoring of Proton- and Carbon-Therapy. Combined Development of Time-of-Flight Collimated- and Compton-Cameras
Autorzy:
Dauvergne, D.
Freud, N.
Krimmer, J.
Létang, J.
Testa, E.
Powiązania:
https://bibliotekanauki.pl/articles/1402603.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
07.85.Fv
87.53.Bn
87.56.Fc
87.56.-v
Opis:
Prompt-gamma imaging during ion therapy has proven its ability to control the ion range in real time. The achievable precision is of the order of the millimeter for a single spot in proton pencil beam scanning. Collimated gamma cameras have been developed, that are close to clinical application. The Compton cameras are also under development in various laboratories. Time of flight enables the reduction of the background due to other prompt radiations.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1445-1448
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies