Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kondensator" wg kryterium: Temat


Tytuł:
Badania generatora indukcyjnego wzbudzanego kondensatorami
Research of induction generator excited capacitors
Autorzy:
Dybowski, P.
Orlewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/2076379.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator indukcyjny
kondensator
silnik indukcyjny
Opis:
Induction generator can work connected to power system or connected to separated system. Induction machine work can as generator only at this time, when reactive power is delivered to machine. Special selected capacitors were connected to the motor for realization this task. It is possible to use this generator as energy source in small water or wind power plant. Authors call special attention for stabilization of amplitude and frequency of generated voltage.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 23-26
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania generatora indukcyjnego wzbudzanego kondensatorami – obcia/enie niesymetryczne
Research of induction generator excited capacitors - non-symmetrical load
Autorzy:
Dybowski, P.
Orlewski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1374016.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
generator indukcyjny
kondensator
maszyna indukcyjna
obciążenie niesymetryczne
Opis:
Induction generator can work connected to power system or connected to separated system. Induction machine work can as generator only at this time, when reactive power is delivered to machine. Special selected capacitors were connected to the motor for realization this task. It is possible to use this generator as energy source in small water or wind power plant. Authors call special attention for stabilization of amplitude and frequency of generated voltage. Measurements and time registration for non-symmetrical load are presented in this paper.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2008, 80; 9-14
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oscylacje w filtrach wejściowych przekształtnikowych napędów trakcyjnych
Oscillations in input filters of converter-based traction drives
Autorzy:
Dudek, R.
Kosiorowski, S.
Stobiecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1373077.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
napęd trakcyjny
filtr wejściowy
kondensator
Opis:
LC input filters are applied in the traction drives with DC or AC motors controlled with the power electronic systems. As follows from experience in operation of the electric mine locomotives the most frequent reason for faults of these systems are faults of the filter's capacitors. Oscillations of voltage and current during the transient states of the drive operation can be one of the reasons for the damage of the capacitors. In this paper, special attention is paid to the angular frequency of oscillations of the voltage across the filter capacitor in transient states of drive operation. This quantity can be used in diagnostic and elimination of fault operation of the power electronic systems of the vehicles' drives. On the basis of a simplified model of the traction system, non-linear equation describing the system is formulated, linearized characteristic equation is given and minimum value of the filter capacity ensuring stable operation of the system is determined. The relationship determining the angular frequency is derived. The analysis of the influence of the filter capacity, inductance and resistance of the traction network, supply source voltage and power of the drive on the angular frequency of the oscillations of the voltage across the filter capacitor is carried out using simulations in the IsSpice program. Selected results of tests of the laboratory traction drive system equipped with a traction motor of the mine locomotive type Ld 31 are presented in the last section of the paper.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 86; 5-10
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of emergency condenser system response to loss of coolant accident in a BWR III+ generation
Modelowanie zachowania systemu kondensatora awaryjnego w przypadku awarii utraty chłodziwa w reaktorze BWR generacji III+
Autorzy:
Bryk, Rafał
Schmidt, Holger
Mull, Thomas
Powiązania:
https://bibliotekanauki.pl/articles/300663.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
boiling water reactor
emergency condenser
LOCA
Modelica
reaktor wodny wrzący
kondensator awaryjny
awaria utraty chłodziwa
Opis:
Emergency Condenser (EC) is a heat exchanger composed of a large number of slightly inclined U-tubes arranged horizontally. The inlet header of the condenser is connected with the top part of the Reactor Pressure Vessel (RPV), which is occupied by steam during critical operation. The lower header in turn is linked with the RPV below the liquid water level during normal operation of the reactor. The tube bundle is filled with cold water and it is located in a vessel filled with water of the same temperature. Thus, the EC and RPV form together a system of communicating vessels. In case of an emergency and a decrease of the water level in the RPV, the water flows gravitationally from U-tubes to the RPV. At the same time the steam from the RPV enters to the EC and condenses due to its contact with cold walls of the EC. The condensate flows then back to the RPV due to the tubes inclination. Hence, the system removes heat from the RPV and serves as a high- and low-pressure injection system at the same time. In this paper a model of the EC system is presented. The model was developed with Modelica modeling language and OpenModelica environment which had not been used in this scope before. The model was verified against experimental data obtained during tests performed at INKA (Integral Test Facility Karlstein) ̶ a test facility dedicated for investigation of the passive safety systems performance of KERENA ̶ generation III+ BWR developed by Framatome.
Kondensator awaryjny jest wymiennikiem ciepła złożonym z dużej ilości U-rurek lekko nachylonych względem pozycji horyzontalnej. Kolektor wlotowy kondensatora połączony jest pojedynczym przewodem z górną częścią zbiornika ciśnieniowego reaktora, w której w trakcie normalnej pracy reaktora znajduje się para wodna. Dolny kolektor połączony jest natomiast ze zbiornikiem ciśnieniowym poniżej lustra wody w stanie ciekłym. Wiązka rurek kondensatora, w trakcie krytycznej pracy reaktora, wypełniona jest zimną wodą i zanurzona jest w basenie z wodą o tej samej temperaturze. Wiązka rurek kondensatora oraz rur doprowadzających tworzą wraz ze zbiornikiem ciśnieniowym zespół naczyń połączonych. W razie sytuacji awaryjnej, w przypadku spadku poziomu wody w zbiorniku ciśnieniowym, woda z kondensatora spływa grawitacyjnie do zbiornika ciśnieniowego, a para, która dostaje się do U-rurek kondensuje na skutek wymiany ciepła z zimną wodą otaczającą kondensator od zewnątrz. W ten sposób kondensator działając pasywnie, zastępuje wysokociśnieniowy oraz niskociśnieniowy wtrysk wody chłodzącej do zbiornika ciśnieniowego. W artykule przedstawiono model systemu kondensatora awaryjnego wraz ze zbiornikiem ciśnieniowym. Model został wykonany przy użyciu niestosowanego wcześniej w tym zakresie języka Modelica oraz środowiska OpenModelica. Następnie opracowany kod został zweryfikowany poprzez porównanie wyników z pomiarami eksperymentalnymi przeprowadzonymi na obiekcie INKA (Integral Test Facility Karlstein) – obiekcie testowym dedykowanym badaniom nad pasywnymi systemami bezpieczeństwa reaktora KERENA – reaktora BWR generacji III+ opracowanego przez firmę Framatome.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 468-475
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of KERENA emergency condenser
Autorzy:
Bryk, R.
Schmidt, H.
Mull, T.
Wagner, T.
Ganzmann, I.
Herbst, O.
Powiązania:
https://bibliotekanauki.pl/articles/240358.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
Kerena
emergency condenser
Modelica
OpenModelica
kondensacja
kondensator awaryjny
Opis:
KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA) was built in Karlstein, Germany. The emergency condenser (EC) system transfers heat from the reactor pressure vessel (RPV) to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA). The comparison shows a good agreement. Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 29--51
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer during condensation of refrigerants in tubular minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/239949.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodzenie
kompaktowy kondensator
kondensacja w minikanałach
wymiana ciepła
compact condenser
condensation in minichannels
heat transfer
refrigeration
Opis:
Abstract The present paper describes the results of experimental investigations of heat transfer during condensation of R134a, R404A and R407C in pipe minichannels with internal diameters 0.31-3.30 mm. The results concern investigations of the local heat transfer coefficient. The results were compared with the correlations proposed by other authors. Within the range of examined parameters of the condensation process in minichannels made of stainless steel, it was established that the values of the heat transfer coefficient may be described with Akers et al., Mikielewicz and Shah correlations within a limited range of the mass flux density of the refrigerant and the minichannel diameter. On the basis of experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient.
Źródło:
Archives of Thermodynamics; 2012, 33, 2; 3-22
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure drop during condensation of refrigerants in pipe minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/240165.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompaktowy kondensator
przepływ
skraplanie
skraplaniea w minikanałach
spadek ciśnienia
compact condenser
condensation in minichannels
pressure drop during flow in condensation
Opis:
The present paper describes results of experimental investigations of pressure drop during the condensation of R134a, R404a and R407C refrigerants in pipe minichannels with internal diameter 0.31-3.30 mm. The results concern investigations of the mean and local pressure drop in single minichannels. The results of experimental investigations were compared with the calculations according to the correlations proposed by other authors. A pressure drop during the condensation of refrigerants is described in a satisfactory manner with Friedel and Garimella correlations. On the basis of the experimental investigations, the authors proposed their own correlation for calculation of local pressure drop during condensation in single minichannels.
Źródło:
Archives of Thermodynamics; 2012, 33, 1; 87-106
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza teoretyczna ciśnienia akustycznego propagowanego przez strukturę modelu fizycznego kondensatora elektroenergetycznego
Theoretical analysis of acoustic pressure propagate by structure of power capacitor physical model
Autorzy:
Błachowicz, A.
Kurtasz, P.
Powiązania:
https://bibliotekanauki.pl/articles/377391.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
kondensator
wyładowania niezupełne
metoda elementów skończonych
Opis:
W artykule przedstawiono wyniki analizy teoretycznej wykonanej przy użyciu symulacji komputerowych opierających się na metodzie elementów skończonych. Analizy dotyczą propagacji fali akustycznej emitowanej ze źródła punktowego przez strukturę fizyczną kondensatora elektroenergetycznego. W obszarze badań było wyznaczenie drogi propagacji fali akustycznej w postaci ciśnienia akustycznego w danych punktach modelu, emitowanego z punktowego źródła fali akustycznej o zadanych właściwościach. Przeprowadzono analizy zmian ciśnienia akustycznego w strukturze obiektu symulowanego jak również w jego okolicy. Na podstawie uzyskanych rezultatów uzyskano analityczny, akustyczny model przestrzenny kondensatora elektroenergetycznego.
The article presents the results of theoretical analysis performed using computer simulations based on the finite element method. Analysis concern the propagation of acoustic waves emitted from a point source by the physical structure of the power capacitor. In the area of research was to determine the propagation path of the acoustic wave in the form of acoustic pressure at specific points of the model, emitted from a point source of acoustic waves with specified properties. Analyses of changes of sound pressure in the structure of the object simulated as well as in its surroundings. Based on the results obtained established analytical, acoustic spatial model of power capacitor.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 171-183
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona układu izolacyjnego transformatora współpracującego z falownikami
Protection of the transformer insulation system cooperating with inverters
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2142529.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
falownik
kondensator
warystor
transformer
inverter
capacitor
varistor
Opis:
Farmy fotowoltaiczne są łączone z siecią elektroenergetyczną poprzez falownik DC/AC i transformator. Komutacja prądu w zaworach falownika generuje w indukcyjnościach rozproszenia impulsy napięcia, które oddziałują na układ izolacyjny uzwojeń transformatora. Skuteczną ochronę izolacji uzwojeń transformatora przed przepięcia stanowią filtry tłumiące. Mogą to być kondensatory bądź warystory. Filtr w sposób znaczący poprawia warunki dielektryczne izolacji uzwojenia transformatora.
The solar farms are connected to the electricity grid through a DC / AC inverter and a transformer. The current commutation in the inverter valves generates voltage pulses in the leakage inductances, which act on the insulation system of the transformer windings. Suppression filters provide effective protection of the transformer winding insulation against overvoltage. These can be capacitors or varistors. The filter significantly improves the dielectric conditions of the transformer winding insulation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 41--44
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies