Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Yamashita, S." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Monitoring of cutting process in end milling of hard and brittle materials
Autorzy:
Shimana, K.
Kondo, E.
Yoshidome, A.
Yamashita, S.
Kawano, Y.
Powiązania:
https://bibliotekanauki.pl/articles/99634.pdf
Data publikacji:
2014
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
glass milling
micromachining
brittle materials
end mill
Opis:
Glass materials have been widely used in optical components in recent years. The purpose of this study was to develop an effective method for real-time detection of the state of cutting tools used in end milling of hard brittle materials. Cutting tests were performed to identify parameters that are useful in monitoring micro tool wear in glass milling. A specific component of the cutting force was found to be related to the progression of tool wear. Furthermore, using fast Fourier transform (FFT) analysis, the peak amplitudes of the cutting forces were found to occur at a specific frequency.
Źródło:
Journal of Machine Engineering; 2014, 14, 4; 55-64
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of portable blood glucose meters using canine and feline pooled blood samples
Autorzy:
Mori, A.
Oda, H.
Onozawa, E.
Shono, S.
Takahashi, T.
Yamashita, S.
Fujimoto, H.
Sako, T.
Powiązania:
https://bibliotekanauki.pl/articles/30884.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
This study evaluated the accuracy and reproducibility of a human portable blood glucose meter (PBGM) for canine and feline whole blood. Reference plasma glucose values (RPGV) were concurrently measured using glucose oxidation methods. Fifteen healthy dogs and 6 healthy cats were used for blood sampling. Blood glucose concentrations and hematocrits were adjusted using pooled blood samples for our targeted values. A positive correlation between the PBGM and RPGV was found for both dogs (y = 0.877, x = −24.38, r = 0.9982, n = 73) and cats (y = 1.048, x = −27.06, r = 0.9984, n = 69). Acceptable results were obtained in error grid analysis between PBGM and RPGV in both dogs and cats; 100% of these results were within zones A and B. Following ISO recommendations, a PBGM is considered accurate if 95% of the measurements are within ± 15 mg/dl of the RPGV when the glucose concentration is <100 mg/dl and within ±15% when it is ≥100 mg/dl; however, small numbers of samples were observed inside the acceptable limits for both dogs (11%, 8 of 73 dogs) and cats (39%, 27 of 69 cats). Blood samples with high hematocrits induced lower whole blood glucose values measured by the PBGM than RPGV under hypoglycemic, normoglycemic, and hyperglycemic conditions in both dogs and cats. Therefore, this device is not clinically useful in dogs and cats. New PBGMs which automatically compensate for the hematocrit should be developed in veterinary practice.
Źródło:
Polish Journal of Veterinary Sciences; 2016, 19, 4
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiazki perfluorowane w wodzie pitnej
Perfluorinated compounds in potable water
Autorzy:
Rostkowski, P
Taniyasu, S.
Yamashita, N.
Falandysz, J.
Powiązania:
https://bibliotekanauki.pl/articles/876193.pdf
Data publikacji:
2008
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
woda pitna
wody mineralne
woda dejonizowana
zanieczyszczenia wod
zwiazki perfluorowane
sulfonian perfluorooktanu
kwas perfluorooktanowy
Japonia
Polska
drinking water
mineral water
deionized water
water contaminant
perfluorinated compound
perfluorooctane sulfonamide
perfluorooctanoic acid
Japan
Polska
Opis:
W badaniach pilotowych oznaczono zawartość związków perfluorowanych takich jak: sulfonian perfluorobutanu (PFBS), sulfonian perfluoroheksanu (PFHS), sulfonian perfluorooktanu (PFOS), sulfonamid perfluorooktanu (PFOSA), kwas perfluoroheksanowy (PFHxA), kwas perfluoroheptanowy (PFHpA), kwas perfluorooktanowy (PFOA), kwas perfluorononanowy (PFNA), kwas perfluorodekanowy (PFDA), kwas perfluorotetradekanowy (PFTeDA), kwas perfluoroheksadekanowy (PFHxDA) i kwas perfluorooktadekanowy (PFOcDA) w japońskich i polskich gatunkach wody mineralnej butelkowanej oraz w pitnej wodzie wodociągowej. Butelkowana woda mineralna w obu krajach zawierała ultraśladowe ilości niektórych związków perfluorowanych, a większe zanieczyszczenie cechowało wodę wodociągową. Stężenia PFOS i PFOA były dużo mniejsze niż stosowne wartości progowe dla efektów szkodliwych, a dla analizowanych przypadków iloraz ryzyka (HQ) był znacznie < 1.
In a pilot study perfluorinated compounds such as perfluorobutane sulfonate (PFBS), perfluorohexane suflonate (PFHS), perfluorooctane sulfonate (PFOS), perfluorooctane sulfonamide (PFOSA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluorotetradecanoic acid (PFTeDA), perfluorohexadecanoic acid (PFHxDA) and perfluorooctadecanoic acid (PFOcDA) have been determined in the Japanese and Polish brands of bottled mineral water and in tap water. Bottled mineral water from both countries contained ultratrace amounts of some perfluorinated compounds, and higher degree of contamination showed tap water. PFOS and PFOA concentrations were much below threshold level for toxic effects, and Hazard Quotient (HQ) was much < 1.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2008, 59, 3; 283-292
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and evaluation of novel mri contrast agents of chemically modified GD-DTPA complexes with sugars
Autorzy:
Sugiyama, M.
Yamashita, M.
Yu, G.
Fujie, M.
Ogawa, K.
Ozaki, N.
Aoki, T.
Mizuno, S.
Okada, S.
Tachi, K.
Aoshima, K.
Sankar, U. R.
Kumar, B. S.
Takehara, Y.
Sakahara, H.
Powiązania:
https://bibliotekanauki.pl/articles/385252.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
MRI contrast agent
Gd(III)-DTPA
tumor imaging
Opis:
MRI is one of medical diagnostic imaging technologies that can draw the cross section in the body. To obtain a clearer image, Gd complexes are often used as MRI contrast agents. Gd-DTPA (Gd-Diethylenetriaminepentaacetate, Magnevist registered trademark ) is used in particular as the MRI contrast agents. We prepared and evaluated novel MRI contrast agents that were chemically modified Gd-DTPA with sugars (represented as Gd-DTPA-Sugar) via hydrolysis route for providing specificity to target organs and tissues. Gd-DTPASugar complex showed an excellent potential for the MRI contrast agent (r1=31.2 s-1mM-1). Gd-DTPA-Sugar complexes alternatively prepared by shorter synthetic route without protection/ deprotection (hydrolysis) method showed inferior results (r1=6.3 and 8.1 s-1mM-1) to the hydlized product.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 191-194
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
R&D of novel medicinal materials for curing cancer: sugar modified Gd-DTPA MRI contrast agents and phospha sugar anti-cancer agents
Autorzy:
Yamashita, Y.
Yamashita, M.
Fujie, M.
Suyama, K. A. T.
Ito, S.
Reddy, V. K.
Yamada, M.
Ogawa, K.
Ozaki, N.
Nakamura, S.
Aoki, T.
Yu, G.
Aoshima, K.
Kato, T.
Kamikage, N.
Kiyofuji, K.
Takehara, Y.
Sakahara, H.
Takayanagi, H.
Oshikawa, T.
Laurent, S.
Burtea, C.
Van der Elst, L.
Muller, R. N.
Powiązania:
https://bibliotekanauki.pl/articles/385218.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
MRI contrast agent
sugar-ball-dendrimer
Gd (III)-DTPA complex
phospha sugars
phospholanes
anticancer agent
tumor
Opis:
Novel Sugar Dendritic Gd-DTPA Complexes for MRI Contrast Agents were prepared and evaluated by in vitro and in vivo methods. The sugar dendritic MRI contrast agents have a good blood vesse pool character, and draw blood vessels and liver cancer remarkably clearer than the clinically using Gd-DTPA. Phospha sugar derivatives or phosphorus heterocyclic derivatives provided by functional groups such as epoxide, bromide, etc., were prepared and evaluated by MTT in vitro method. These phospha sugar derivatives showed excellent activities against leukemia cells as well as solid cancer cells in fashions of (i) higher activity, (ii) wider spectra, (iii) higher selectivity and specificity distingushing healthy and cancer cells, etc., compared with the molecular targeting chemotheraputic anti-cancer agent, Gleevec.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 80-83
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies