Tytuł:
Distance protection with dynamic thermal line rating enhancement
Autorzy:
Staszewski, Ł.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410531.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
overload
heat balance
Opis:
As the worldwide analysis of recent wide area cascading failures have shown, very often the main cause of blackout was mal-operation of the third zone of a distance protection relay. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection mal-function. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to controlled impedance encroachment.This paper proposes a new approach to enhance the distance protection relay operation by introducing a new blocking algorithm. The algorithm is based on Dynamic Thermal Line Rating (DTLR) idea to restrain relay from tripping when conditions in electrical power system and weather conditions allow for it.
Źródło:
Present Problems of Power System Control; 2012, 2; 73-84
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Blackout prevention possibility using dynamic thermal line rating
Zastosowanie dynamicznej cieplnej obciążalności linii przesyłowych jako możliwości zapobiegania blackoutom
Autorzy:
Staszewski, Ł.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410569.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
blackout prevention
heat equation
Opis:
This paper presents the Dynamic Thermal Line Rating (DTLR) application, based on the heat equations, that makes possible overhead transmission lines operation over their conservatively designed current ratings. The DTLR concept is well known - owing to the CIGRE [1,2] and IEEE [3] standards for overhead bare conductor temperature calculations. However, this phenomenon may not have been used for a purpose of increasing electrical power system stability and thus for blackout prevention. This paper is based on both CIGRE and IEEE standards and presents investigation of the current flow through various conductors. Their temperature and monitoring ambient weather conditions and thermal limits of a conductor are considered. The influence of the weather conditions on the lines flow capacities is presented as a comparison of various types of AFL 6 conductor and various weather conditions. Also the short analysis of the recent blackouts and possibilities of DTLR use are presented. Obtained results are described and conclusions are drawn.
Artykuł przedstawia zastosowanie dynamicznej termicznej obciążalności linii przesyłowych (DTOLP) jako narzędzia umożliwiającego unikanie powstawania lub dalszego rozwoju powstałej już awarii wielkoobszarowej systemu elektroenergetycznego. Sama idea DTOLP jest dobrze znana, dzięki standardom CIGRE i IEEE służącym do obliczeń termicznego stanu przewodu jako funkcji warunków pogodowych oraz przepływającego przez przewód prądu elektrycznego. Na potrzeby artykułu korzystano z obu standardów i zaprezentowano analizę wpływu przepływu prądu w różnych przewodach na ich możliwości przesyłowe w zależności od otaczających je warunków pogodowych. Dodatkowo artykuł podkre sla istotność przeciążeń linii przesyłowych, jako elementu wywołującego lub pogłębiającego awarie wielkoobszarowe oraz możliwość zastosowania dynamicznej termicznej obciążalności linii przesyłowych w celu zapobiegania tym zjawiskom.
Źródło:
Present Problems of Power System Control; 2011, 1; 15-21
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal calculation for distance protection enhancement
Autorzy:
Staszewski, Ł
Rebizant, W
Powiązania:
https://bibliotekanauki.pl/articles/410608.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
power swing
third zone
Opis:
Worldwide analysis of recent wide area cascading failures has shown that very often their main cause was the mal-operation of the distance protection relay third zone. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to impedance encroachment while there was no risk of further, continuous operation. This paper proposes a way to improve operation of the distance protection relay by introducing a new blocking algorithm that uses the Dynamic Thermal Line Rating (DTLR) to restrain relay from tripping when conditions in electrical power system allow for it.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 83-94
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of ferroresonance phenomena in HV power networks
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410561.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inductive voltage transformer
ferroresonance oscillations
high voltage networks
simulation
Opis:
Analysis of ferroresonance phenomena in high voltage (HV) power networks is presented in this paper. The adequate digital simulation model for investigation of ferroresonance oscillations in MATLAB/Simulink program was developed. In the paper HV power system configuration with circuit breaker grading capacitors was described and analyzed. The phase as well as open delta VT voltages and their spectra were considered as signals for ferroresonance detection. Additionally, the possibility of ferroresonance oscillations suppression was also studied.
Źródło:
Present Problems of Power System Control; 2015, 6; 5-14
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptacyjne szerokopasmowe estymatory składowych impedencji
Adaptive wide frequency band estimators of impedance components
Autorzy:
Szafran, J.
Rebizant, W.
Michalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/157730.pdf
Data publikacji:
1998
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Opis:
Przedstawiono szerokopasmowe adaptacyjne algorytmy pomiaru składowych impedencji, które moga być stosowane np w układach sterowania i zabezpieczeń generatorów elektroenergetycznych. Istota metody sprowadza się do dwóch zasad: opracowania algorytmów niewrażliwych na niewielkie zmiany częstotliwości sygnałów oraz wyznaczenia przybliżonej wartości częstotliwości sygnałow pomiarowych i adaptacji do niej tych waskopasmowych algorytmów. Proponowaną metodę testowano symulacyjnie według róznych scenariuszy zmian częstotliwości sygnałów pomiarowych, z uwzględnieniem różnego poziomu zakłóceń, uzyskując błędy o wartościach podobnych do tych jakie obserwuje się dla algorytmów projektowanych na nominalną częstotliwość 50 Hz.
A raport on adaptive wide frequency band algorithmus for measuring impedance components that can be used e.g. in control and protection systems of electric power generators. Essence of the method boils down to two questions: working out algorithms insensitive to slight changes in signalsá frequency and determining an approximate measurement signalsá frequency and adapting to it these narrow band algorithms. This method was tested by simulation according. To different scenerios of changes in the measurement signalsá frequency with an account taken of different interference levels, which revealed errors of values similar to those observed in algorithms designed for the nominal frequency 50 Hz.
Źródło:
Pomiary Automatyka Kontrola; 1998, R. 44, nr 12, 12; 438-444
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New method of CT saturation detection
Autorzy:
Bąk, D.
Dong, X.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410533.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
CT saturation detection
protective relaying
transient analysis
Opis:
A new method for detection of CT saturation is presented in this paper. The presented algorithm applies a new, innovative methodology mapping first order derivative of phase current signals into coordinates of a 3D vector. The comparison of proposed algorithm with standard one based on secondary current signal's second derivative is conducted and some of simulation results are presented to show the proposed algorithm effectiveness.
Źródło:
Present Problems of Power System Control; 2012, 2; 65-72
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies