Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Piechocki, R." wg kryterium: Autor


Tytuł:
Effects of Sodium Chloride on Growth and Mineral Nutrition of Purpletop Vervain
Autorzy:
Salachna, P.
Piechocki, R.
Powiązania:
https://bibliotekanauki.pl/articles/125276.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ion concentration
salinity stress
Verbena bonariensis
clustertop vervain
Opis:
There is a rising demand for salt-tolerant species for landscaping. Purpletop vervain is an excellent landscape plant for gardens and parks, with fragrant lavender to rose-purple flowers. However, little is known concerning the effect of sodium chloride on morphological characteristics, flowering and mineral uptake of purpletop vervain. In this study, carried out in 2013–2014, the plants of purpletop vervain were grown in pots in an unheated plastic tunnel. The plants were watered with 200 mM NaCl solution four times, every seven days. Salinity-exposed plants were characterized by slightly reduced plant height, weight of the aboveground part and visual score. Salt stress caused also an increase in leaf content sodium, chlorine and manganese. Salinity had no effect on earliness of flowering and content in leaves of phosphorus, potassium, magnesium, copper, zinc and iron. Purpletop vervain seems to be plant species able to tolerate salt stress under controlled conditions.
Źródło:
Journal of Ecological Engineering; 2016, 17, 2; 148-152
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plant Growth of Curly Kale Under Salinity Stress
Autorzy:
Salachna, P.
Piechocki, R.
Byczyńska, M.
Powiązania:
https://bibliotekanauki.pl/articles/952358.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sodium chloride
ornamental plants
stomatal conductance
SPAD
Opis:
Ornamental plants growing in urban areas are exposed to soil salinity that negatively affects their quality. Identifying species that retain high ornamental value despite salt stress is therefore of high practical importance. Curly kale (Brassica oleracea L. var. sabellica L.) is an attractive plant with leaves of both edible and ornamental character. The aim of the study was to evaluate a response of ornamental curly kale to different concentrations of NaCl. The study material was ‘Scarlet’ cultivar. The plants were grown in pots in a plastic tunnel. They were irrigated with NaCl solution at the following concentrations: 50, 100, 200, 400, and 800 mM mmol·dm-3. NaCl treatment resulted in a significant increase in pH and electrical conductivity (EC) of the substrate. Salt stress significantly affected plant growth and number, width and length of leaves, and the effects depended on NaCl concentration. Fifteen days after the salt supply ceased, relative chlorophyll content in leaves (SPAD) decreased due to NaCl treatment in a concentration-dependent manner. Treatments with 200, 400, and 800 mmol·dm-3 NaCl reduced stomatal conductance, and the changes were greater on the 5th day following the stress cessation than on the 15th day. Irrigation with a 200, 400, and 800 mmol·dm-3 NaCl solution negatively affected plant bonitation score. The plants treated with 50 i 100 mmol·dm-3 NaCl were not significantly different visual score from the control plants.
Źródło:
Journal of Ecological Engineering; 2017, 18, 1; 119-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozmnażanie śniedka arabskiego (Ornithogalum arabicum L.) przez sadzonki dwułuskowe z wykorzystaniem ekstraktów z alg morskich
Propagation of arabian star flower (Ornithogalum arabicum L.) by twin scales using seaweed extracts
Autorzy:
Salachna, P.
Zawadzinska, A.
Piechocki, R.
Wilas, J.
Powiązania:
https://bibliotekanauki.pl/articles/82410.pdf
Data publikacji:
2014
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Opis:
Aim of the experiment carried out in 2008–2009 was to assess the effect of the kind of twin scales and seaweed extracts on yield of adventitious bulbs of Arabian Star Flower (Ornithogalum arabicum L.). The twin scales were excised from the outer and inner of the parent bulb. The twin scales were soaked for 30 minutes in 0.2% solution of AlgaminoPlant and Goëmar Goteo containing extracts of algae Ascophyllum and Sargassum. The research showed the number of adventitious bulbs formation was greater when twin scales were excised from the outer of the parent bulb. The adventitious bulbs formed from outer twin scales had a higher fresh weight, circumference, number and length of roots. The seaweed extracts used stimulated the number and length of roots of adventitious bulbs.
Źródło:
Folia Pomeranae Universitatis Technologiae Stetinensis. Agricultura, Alimentaria, Piscaria et Zootechnica; 2014, 30
2081-1284
Pojawia się w:
Folia Pomeranae Universitatis Technologiae Stetinensis. Agricultura, Alimentaria, Piscaria et Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Response of Speckled Spur-Flower to Salinity Stress and Salicylic Acid Treatment
Autorzy:
Salachna, P.
Piechocki, R.
Zawadzińska, A.
Wośkowiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/124848.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
Plectranthus ciliatus
ion concentration
purple leaved plectranthus
salinity stress
Opis:
One of the limitations to using ornamental plants in green areas is too high salinity and alkalization of the soil. The adverse effect of salinity on plant growth and de-velopment may be effectively reduced by application of salicylic acid. Plectranthus ciliatus is an attractive bed plant with ornamental leaves, recommended for growing in containers, hanging baskets, or sunny borders. The aim of this study was to investi-gate the response of P. ciliatus to salicylic acid and calcium chloride. The plants were grown in pots in a glasshouse and were sprayed with solution of 0.5 mM salicylic acid and watered with 200 mM calcium chloride. The application of salicylic acid resulted in an increased weight of the aboveground parts, higher stomatal conductance and leaf greenness index and enhanced leaf content of nitrogen, potassium, iron and zinc. Salinity-exposed plants were characterized by reduced weight, stomatal conductance and leaf greenness index. Salt stress caused also a drop in leaf content of nitrogen, po-tassium and iron, and an increase in calcium, sodium, chlorine, copper and manganese concentration. Salicylic acid seemed to relieve salinity-mediated plant stress.
Źródło:
Journal of Ecological Engineering; 2015, 16, 5; 68-75
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutki dynamiczne w rozdzielni dla warunków zwarciowych w środkowej części rozdzielni
Dynamic effects in distribution substation under short-circuit conditions in central section of substation
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/376657.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
rozdzielnie najwyższych napięć
dynamiczne skutki zwarciowe
symulacja
Opis:
Prezentowane zagadnienie jest kontynuacją badań w dotyczących oceny wartości czasu trwania zwarcia w obliczeniach skutków zwarciowych metodą probabilistyczną. W artykule przedstawiono rozbudowany model rozdzielni do symulacyjnej analizy warunków zwarciowych i skutków dynamicznych w środkowej części szyn zbiorczych. W modelu uwzględniono rozpływ prądów zwarciowych w rozdzielni oraz działanie elektroenergetycznej automatyki zabezpieczeniowej EAZ i wyłączników w rozdzielniach najwyższych napięć podczas zwarć w systemie elektroenergetycznym. Przedstawiono wyniki badań symulacyjnych, mających na celu oszacowanie częstości występowania określonych wartości prądu zwarciowego, czasu trwania zwarcia oraz sił dynamicznych. Obliczenia wykonano dla różnych konfiguracji układu EAZ.
Presented topic is the continuation of investigations concerning the estimation of short-circuit duration when computing the short-circuit effects using probabilistic methods. In the paper, an expanded model of distribution substation for simulationbased analysis of the short-circuit conditions and dynamic effects in the central section of bus-bar is presented. In the model, the short circuit currents’ flow in the distribution station as well as the operation of the EAZ power automatic protections and circuit breakers in the EHV distribution substations during faults in the electric power system have been considered. The results of simulations aiming to assess the frequency of occurrence of the defined values of short-circuit current, short-circuit duration and dynamic forces are reported. Computations have been carried out for different EAZ system configurations.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 199-206
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki wpływające na wartości czasu trwania zwarcia określane podczas analizy sił dynamicznych w rozdzielni
Factors affecting short-circuit duration values being determined during analysis of dynamic forces in distribution substation
Autorzy:
Piechocki, P.
Frąckowiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/376815.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
skutki dynamiczne
czas trwania zwarcia
rozdzielnie najwyższych napięć
symulacja
Opis:
Artykuł dotyczy zagadnienia określania wartości czasu trwania zwarcia podczas obliczania skutków dynamicznych w rozdzielniach najwyższych napięć z przewodami giętkimi metodą statystyczno-probabilistyczną. Do realizacji zadania opracowano model symulacyjny, którego ważnym elementem jest model czasu trwania zwarcia. Wykorzystując opracowaną metodę określania wartości czasu trwania zwarcia dla potrzeb obliczeń dynamicznych sił w rozdzielniach elektroenergetycznych opartą na kryterium ryzyka, zbadano wpływ parametrów przęsła, konfiguracji EAZ oraz awaryjności wyłączników i zabezpieczeń na rezultaty prowadzonych badań.
The paper refers to the finding of the short-circuit duration values when computing the dynamic effects in the EHV distribution substations with flexible conductors using statistical-probabilistic method. A dedicated simulation model comprising an important element i.e. a short-circuit duration model has been developed. Using the elaborated risk criterion-based method of determination of the short-circuit duration values when computing the dynamic forces in the distribution substations, the influence of the span parameters, EAZ configuration and failure rate of the circuit-breakers and protections on the results of the conducted investigations has been discussed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 45-55
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ parametrów rozdzielni na dobór wartości czasu trwania zwarcia na liniach przesyłowych do obliczania skutków dynamicznych
Influence of substation parameters on the choice of fault duration on transmission lines for dynamic effects’ calculation
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/377520.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
sieć elektroenergetyczna
rozdzielnia najwyższych napięć
linie przesyłowe
wartość czasu trwania zwarcia
skutki zwarciowe
Opis:
W artykule przedstawiono metodę oceny wartości czasu trwania zwarcia na linii przesyłowej z punktu widzenia skutków dynamicznych w rozdzielniach najwyższych napięć NN z przewodami szynowymi giętkimi. Jako kryterium doboru wartości czasu trwania zwarcia przyjęto spodziewaną roczną częstość przekroczeń wyznaczanych sił dynamicznych. Wyniki badań symulacyjnych, wykonanych metodą Monte Carlo ukazują wpływ parametrów rozdzielni i zainstalowanych w niej urządzeń (napięcia znamionowego, mocy zwarciowej, zawodności wyłączników i zabezpieczeń, konfiguracji EAZ) na proponowane wartości czasu trwania zwarcia w zwarciowych obliczeniach inżynierskich.
In the paper, a method of assessment of the fault duration on the transmission line is presented regarding dynamic effects in the highest LV substations equipped with flexible bus conductors. Expected yearly frequency of exceeding the calculated dynamic forces has been assumed as the fault duration choice criterion. The simulation results carried out using the Monte Carlo technique are showing how the parameters of the substation and its devices affect the proposed fault duration values in the engineer’s sort-circuit calculations.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 79-86
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Values of short-circuit duration and dynamie forces during short-circuits in the EHV substations: simulation-based investigations
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97694.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
short-circuit duration
EHV substations
simulation
Opis:
Presented question is the continuation of investigations concerning the short-circuit duration’s estimation in the short-circuit effect calculations using the probabilistic method. In the paper, the developed simulation model of the short circuit duration under the disturbing conditions just in the distribution substation is presented. The model development was based on the analysis of operation of the automatic power protections EAZ and circuit-breakers in the EHV substations during short-circuits. The results of simulation investigations aiming to estimate the frequency of occurrence of the defined short-circuit duration are reported. The calculations have been carried out for different configurations of the EAZ system. For selected spans in the 220 kV substation, probabilistic analysis of dynamic forces accompanying the in-substation faults has been carried out. Also, the way of the short-circuit duration’s estimation when calculating the dynamic effects of the fault current flow basing on an assumed risk value has been proposed.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 171-184
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Factors affecting the choice of fault duration in transmission lines for computation of dynamic effects in EHV distribution substations
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97263.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
substation
dynamic effect
short-circuit duration
probabilistic method
Opis:
In the paper, the method of assessment of the fault duration in transmission line regard¬ing dynamic effects in the EHV distribution stations with flexible bus conductors is pre¬sented. Expected yearly frequency of exceeding the indicated dynamic forces has been assumed to be a criterion of choice of the short-circuit duration values. Results of simula¬tions carried out using Monte Carlo technique have shown the influence of parameters of the distribution substation and devices installed in it (nominal voltage, short-circuit capaci¬ty, unreliability of circuit-breakers and protections, EAZ configurations) on suggested fault duration values in the engineer-type short-circuit computations.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 176-188
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-circuit duration and dynamic forces in central section of substation
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97305.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
EHV distribution substations
short-circuit dynamic effects
simulations
Opis:
Presented topic is the continuation of investigations concerning the estimation of short-circuit duration when computing the short-circuit effects using probabilistic methods. In the paper, an expanded model of distribution substation for simulation-based analysis of the short-circuit conditions and dynamic effects in the central section of bus-bar is presented. In the model, the operation of protections in the transformer bay has also been considered. The results of simulations aiming to assess the frequency of occurrence of the defined values of short-circuit current, short-circuit duration and dynamic forces are reported. Also, the question: “How the transformer’s protections involved in simulation affect the simulated short-circuit conditions?” has been answered. Computations have been carried out for four different EAZ system configurations.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 220-230
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic assessment of the short-circuit duration on the 220 kV transmission line basing on simulation analysis
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97379.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transmission lines
current
simulation analysis
Opis:
In the paper, the problem of defining the short circuit duration time for the short-circuit effect calculations, especially thermal and electromagnetic ones, has been discussed. In author’s opinion, the results of probabilistic research could be helpful when resolving the problem. Therefore, a tailored simulation model based on the analysis of the protections and circuit breakers operation during the transmission lines fault clearance has been developed. Due to the results of simulation study, the found values of the fault duration time could be related to the expected risk of their exceeding depending on both the protection system configuration and the type of the circuit breakers applied.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 275-282
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Invasion in New Zeland snail Potamopyrgus antipodarum (Gray, 1843) in the lakes of Bory Tucholskie
Autorzy:
Piechocki, A.
Kaleta, R.
Powiązania:
https://bibliotekanauki.pl/articles/84383.pdf
Data publikacji:
2001
Wydawca:
Uniwersytet Mikołaja Kopernika. Wydział Biologii i Ochrony Środowiska. Stowarzyszenie Malakologów Polskich
Źródło:
Folia Malacologica; 2001, 09, 2
1506-7629
Pojawia się w:
Folia Malacologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wartości czasu trwania zwarcia podczas zakłóceń w rozdzielniach najwyższych napięć w świetle badań symulacyjnych
Short-circuit duration values under disturbation conditions in extreme high voltage distribution substations simulation-based research
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/376509.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
czas trwania zwarcia
rozdzielnie najwyższych napięć
symulacja
Opis:
Prezentowana problematyka jest kontynuacją badań dotyczących oceny wartości czasu trwania zwarcia w obliczeniach skutków zwarciowych metodą probabilistyczną. W artykule przedstawiono opracowany model symulacyjny czasu trwania zwarcia podczas zakłóceń w rozdzielniach. Model oparto na analizie działania elektroenergetycznej automatyki zabezpieczeniowej EAZ i wyłączników w rozdzielniach najwyższych napięć podczas zwarć. Przedstawiono wyniki badań symulacyjnych, mających na celu oszacowanie częstości występowania określonych wartości czasu trwania zwarcia. Obliczenia wykonano dla różnych konfiguracji układu EAZ.
Presented question is the continuation of investigations concerning the short-circuit duration’s estimation in the short-circuit effect calculations using the probabilistic method. In the paper, the developed simulation model of the short circuit duration under the short-circuit conditions in the distribution substation is presented. The model development was based on the analysis of operation of the automatic power protections EAZ and circuit-breakers in the EHV substations during short-circuits. The results of simulation investigations aiming to estimate the frequency of occurrence of the defined short-circuit duration are reported. The calculations have been carried out for different configurations of the EAZ system.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 81-88
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki zwarciowe w rozdzielni spowodowane zakłóceniami na różnych elementach sieci elektroenergetycznej
Short-circuit conditions in distribution substation due to disturbances on various elements of the grid
Autorzy:
Piechocki, P.
Frąckowiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/377813.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
rozdzielnie najwyższych napięć
warunki zwarciowe
symulacja
Opis:
Prezentowane zagadnienie jest kontynuacją badań w dotyczących oceny czasu trwania zwarcia i dynamicznych skutków zwarciowych w rozdzielniach najwyższych napięć metodą probabilistyczną. Badania są realizowane za pomocą specjalnie opracowywanego modelu do symulacyjnej analizy warunków zwarciowych w rozdzielniach, opartego na metodzie symulacji Monte Carlo. W ramach kolejnego etapu prac oceniono wpływ zakłóceń na różnych elementach sieci na rozkład prawdopodobieństwa prądu zwarciowego i czasu jego przepływu oraz sił dynamicznych w dwóch różnych miejscach rozdzielni 220 kV. Rozpatrzono wpływ zwarć na szynach głównych i w polach rozdzielni, na liniach (długiej i krótkiej) i na transformatorze.
The presented question forms a continuation of the research on the probabilisticbased assessment of the short-circuit duration in the EHV distribution stations is reported. In the research work, a model for simulation-based analysis of short-circuit conditions in distribution substations is applied, and the model using the Monte Carlo simulation technique is being especially developed. In the presented successive step of work, the influence of disturbances at different grid elements on the probability distribution of the short-circuit current and its flow duration and the dynamic forces in two different locations in the 220kV distribution station has been assessed. The analysis has been carried out for the faults across the busbar and in the substation’s bays, on the lines (short and long) and in the transformer.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 86; 177-188
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of dynamic effects in distribution substations with flexible conductors regarding short-circuit duration values
Wartości czasu trwania zwarcia a ocena skutków dynamicznych w rozdzielniach z przewodami giętkimi
Autorzy:
Piechocki, P.
Frąckowiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1365641.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
skutki dynamiczne
czas trwania zwarcia
rozdzielnie najwyższych napięć
symulacja
dynamic effects
short-circuit duration
EHV distribution substations
simulation
Opis:
Artykuł dotyczy zagadnienia określania wartości czasu trwania zwarcia podczas obliczania skutków dynamicznych w rozdzielniach najwyższych napięć z przewodami giętkimi metodą statystyczno-probabilistyczną. Do realizacji zadania opracowano model symulacyjny, którego ważnym elementem jest model czasu trwania zwarcia. Wyniki badań symulacyjnych pozwoliły na przeprowadzenie probabilistycznej analizy wartości czasu trwania zwarcia, prądu zwarciowego oraz sił dynamicznych dla wybranych punktów rozdzielni. W obliczeniach uwzględniono zwarcia na szynach i w polach rozdzielni, transformatorach oraz liniach elektroenergetycznych. Przedstawiono metodę określania wartości czasu trwania zwarcia dla potrzeb obliczeń dynamicznych sił w rozdzielniach elektroenergetycznych opartą na kryterium ryzyka.
The paper refers to the finding of the short-circuit duration when computing the dynamic effects in the EHV distribution substations with flexible conductors using statistical-probabilistic method. A dedicated simulation model comprising an important element i.e. a short-circuit duration model has been developed. Referring to the obtained results, the probabilistic analysis of values of short-circuit duration, short-circuit current and dynamic forces has been carried out for the substation’s selected points. In computations, faults on bus and in the substation’s bays, transformers and electric power lines have been taken into account. A risk criterion- based method of finding the short-circuit duration values needed in computations of dynamic forces in the power distribution substations has been presented.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 2; 237-243
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies