Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gąska, Piotr" wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification
Autorzy:
Gruza, Maciej
Gąska, Adam
Gąska, Piotr
Harmatys, Wiktor
Sładek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103260.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
calibration
accuracy
przegubowa głowica sondy
kalibrowanie
precyzja
Opis:
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 252-259
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Influence of Sample Averaging on Accuracy of Point Coordinates Measurement Performed Using Laser Tracking Systems
Autorzy:
Gruza, Maciej
Gąska, Piotr
Gąska, Adam
Harmatys, Wiktor
Jedynak, Michał
Kobiela, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/102134.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Laser Tracker
measurement uncertainty
accuracy
niepewność pomiaru
dokładność
Opis:
Laser Tracking systems are commonly used in all branches of industry, which requires accurate large-scale measurements for instance aviation, space and shipbuilding industries. Laser Trackers belong to the group of non-Cartesian Coordinate Measuring Systems. Determination of the measured point coordinates involves the measurements of distance using laser beam and two angles recorded by horizontal and vertical encoders. Additionally, the environmental conditions are monitored and used for compensation of measured distance. The coordinates of single measured point are estimated using the results obtained from a series of samples taken in a short time period. The average value obtained from a sample is given as a result; additionally, the dispersion parameters are calculated which can be used to evaluate the probing process. This paper presents the research procedure which allows assessing the influence of chosen dispersion parameter related to the sample averaging on accuracy of the measurements performed with laser tracking devices. The procedure involves standard elements measurements during which the points with similar level of RMS parameter are used for the calculation of the measurement result. Such approach allows simulating the increasing dispersion of points taken into account during sample probing. The results presented in the article can be helpful to the operators of laser tracking systems to assess the influence of the probing process on the measurement accuracy.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 4; 94-99
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zero-Suppression Trigger Mode for GEM Detector Measurement System
Autorzy:
Kolasinski, Piotr
Pozniak, Krzysztof
Wojenski, Andrzej
Linczuk, Pawel
Krawczyk, Rafal
Gaska, Michal
Zabolotny, Wojciech
Kasprowicz, Grzegorz
Chernyshova, Maryna
Czarski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1844608.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FPGA
GEM
trigger
sequencer
DAQ
Xilinx
Opis:
A novel approach to a trigger mode in the Gas Electron Multiplier (GEM) detector readout system is presented. The system is already installed at WEST tokamak. The article briefly describes the architecture of the GEM detector and the measurement system. Currently the system can work in two trigger modes: Global Trigger and Local Trigger. All trigger processing blocks are parts of the Charge Signal Sequencer module which is responsible for transferring data to the PC. Therefore, the article presents structure of the Sequencer with details about basic blocks, theirs functionality and output data configuration. The Sequencer with the trigger algorithms is implemented in an FPGA chip from Xilinx. Global Trigger, which is a default mode for the system, is not efficient and has limitations due to storing much data without any information. Local trigger which is under tests, removes data redundancy and is constructed to send only valid data, but the rest of the software, especially on the PC side, is still under development. Therefore authors propose the trigger mode which combines functionality of two existing modes. The proposed trigger, called Zero Suppression Trigger, is compatible with the existing interfaces of the PC software, but is also capable to verify and filter incoming signals and transfer only recognized events. The results of the implementation and simulation are presented.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 1; 103-108
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Soft X-ray Diagnostic System Upgrades and Data Quality Monitoring Features for Tokamak Usage
Autorzy:
Wojenski, Andrzej
Linczuk, Paweł
Piotr, Kolasinski
Chernyshova, Maryna
Mazon, Didier
Kasprowicz, Grzegorz
Pozniak, Krzysztof T.
Gaska, Michał
Czarski, Tomasz
Krawczyk, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/1844595.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
data quality monitoring
FPGA
Verilog/VHDL
HDL
GEM detector
SXR plasma diagnostics
modular measurement system
data evaluation
tokamak
Opis:
The validation of the measurements quality after on-site diagnostic system installation is necessary in order to provide reliable data and output results. This topic is often neglected or not discussed in detail regarding measurement systems. In the paper recently installed system for soft X-ray measurements is described in introduction. The system is based on multichannel GEM detector and the data is collected and sent in special format to PC unit for further postprocessing. The unique feature of the system is the ability to compute final data based on raw data only. The raw data is selected upon algorithms by FPGA units. The FPGAs are connected to the analog frontend of the system and able to register all of the signals and collect the useful data. The interface used for data streaming is PCIe Gen2 x4 for each FPGA, therefore high throughput of the system is ensured. The paper then discusses the properties of the installation environment of the system and basic functionality mode. New features are described, both in theoretical and practical approach. New modes correspond to the data quality monitoring features implemented for the system, that provide extra information to the postprocessing stage and final algorithms. In the article is described also additional mode to perform hardware simulation of signals in a tokamak-like environment using FPGAs. The summary describes the implemented features of the data quality monitoring features and additional modes of the system.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 1; 109-114
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement Capabilities Upgrade of GEM Soft X-ray Measurement System for Hot Plasma Diagnostics
Autorzy:
Linczuk, Pawel
Wojenski, Andrzej
Kolasinski, Piotr
Krawczyk, Rafal
Zabolotny, Wojciech
Pozniak, Krzysztof
Chernyshova, Maryna
Czarski, Tomasz
Gaska, Michal
Kasprowicz, Grzegorz
Malinowski, Karol
Powiązania:
https://bibliotekanauki.pl/articles/1844588.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measurement system
GEM
DAQ
Opis:
The paper presents improvements of the developed system for hot plasma radiation measurement in the soft Xray range based on a Gas Electron Multiplier (GEM) detector. Scope of work consists of a new solution for handling hardware time-synchronization with tokamak systems needed for better synchronization with other diagnostics and measurement quality. The paper describes the support of new modes of triggering on PC-side. There are communication and data path overview in the system. The new API is described, which provide separate channels for data and control and is more robust than the earlier solution. Work concentrates on stability and usability improvements of the implemented device providing better usage for end-user.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 1; 115-120
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies