Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Balacha, J." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Właściwości modelowej posadzki przemysłowej w kontekście momentu aplikacji posypki i jej zacierania na świeżej mieszance betonowej
Properties of the standard industrial floor in terms of the application time and applying during finishing operations of the dry shake topping
Autorzy:
Balacha, J.
Powiązania:
https://bibliotekanauki.pl/articles/392021.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
posadzka przemysłowa
posypka utwardzająca
procedura aplikacyjna
odporność na ścieranie
aparat Bȍhmego
równanie Fullera-Thompsona
przyczepność do podłoża
industrial floor
dry shake topping
application procedure
wear resistance
Bȍhme apparatus
Fuller-Thompson equation
bond to subground
Opis:
Celem projektu było określenie w jaki sposób na właściwości posadzki przemysłowej wpływa moment rozpoczęcia aplikacji posypki i jej zacierania na świeżej mieszance betonowej na bazie cementu CEM I 42,5 R. W ramach realizacji pracy zaprojektowano i przygotowano posypkę utwardzającą na bazie cementu CEM I 42,5 R, piasków kwarcowych oraz żywicy melaminowej. Ilość wypełniacza określono na podstawie równania Fullera-Thompsona. Dla posypki wyznaczono wytrzymałość na ściskanie oraz odporność na ścieranie na tarczy Böhmego. Po nałożeniu posypka została zatarta ręcznie, a płyty pielęgnowano w warunkach laboratoryjnych. Po okresie dojrzewania zrealizowano badania cyklicznego zamrażania i rozmrażania przy zanurzeniu w soli odladzającej według PN-EN 13687-1:2008. Następnie dokonano oceny wizualnej powierzchni próbek oraz przeprowadzono badanie przyczepności do podłoża. Przeprowadzone badania potwierdziły, że moment aplikacji posypki ma istotny wpływ na walory techniczne posadzki. Wykazano, że przedwczesna aplikacja posypki obniża wytrzymałość na ściskanie i pogarsza przyczepność. W przypadku późniejszego zatarcia posypki wyraźnie spada możliwość połączenia struktury betonu z zacieraną warstwą. Efektem ubocznym jest słabe związanie posypki utwardzającej i niższa odporność na ścieranie.
The aim of the study was to investigate the influence of the application time and applying during finishing operations of the dry shake topping on the surface of freshly laid portland cement based concrete on the properties of the industrial floor. In order to research this objective the dry shake topping based on mixture of the portland cement, quartz sands and melamine resin was designed and prepared. The amount of filler was determined on the basis of the Fuller-Thompson equation. Prepared dry shake topping was examined in terms of its compressive strength and abrasion resistance. The dry shake powder was applying manually on the surface of the concrete slabs at different time intervals. After curing in laboratory conditions the following tests were carried out: determination of thermal compatibility. freeze-thaw cycling with de-icing salt immersion (EN 13687-1:2008). Furthermore, the visual assessment of the specimen surfaces and bonding test were conducted. Obtained test results have confirmed that application time of the dry shake topping has a significant impact on the technical performances of the concrete floor. It has been shown that the premature application affects the compressive strength of the concrete floor and causes deterioration in the bond strength. The side effect of the subsequent spreading of the dry shake powder is the weak dry shake topping – binding ability and lower resistance to abrasion.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2015, R. 8, nr 23, 23; 7-18
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola różnych wypełniaczy w kształtowaniu odporności na ścieranie podkładów podłogowych
Autorzy:
Łagosz, A.
Balacha, J.
Powiązania:
https://bibliotekanauki.pl/articles/342942.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Producentów Cementu
Tematy:
podkład podłogowy
obciążenie eksploatacyjne
ścieralność
utwardzanie powierzchniowe
technologia wykonania
wypełniacz
Źródło:
Budownictwo, Technologie, Architektura; 2012, 3; 68-71
1644-745X
Pojawia się w:
Budownictwo, Technologie, Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies