Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Arkani, M." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
A High Performance Digital Time Interval Spectrometer: An Embedded, FPGA-Based System With Reduced Dead Time Behaviour
Autorzy:
Arkani, M.
Powiązania:
https://bibliotekanauki.pl/articles/221045.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval spectrum
stochastic process
TDC
dead time effect
Monte Carlo simulation
FPGA
Opis:
In this work, a fast 32-bit one-million-channel time interval spectrometer is proposed based on field programmable gate arrays (FPGAs). The time resolution is adjustable down to 3.33 ns (= T, the digitization/discretization period) based on a prototype system hardware. The system is capable to collect billions of time interval data arranged in one million timing channels. This huge number of channels makes it an ideal measuring tool for very short to very long time intervals of nuclear particle detection systems. The data are stored and updated in a built-in SRAM memory during the measuring process, and then transferred to the computer. Two time-to-digital converters (TDCs) working in parallel are implemented in the design to immune the system against loss of the first short time interval events (namely below 10 ns considering the tests performed on the prototype hardware platform of the system). Additionally, the theory of multiple count loss effect is investigated analytically. Using the Monte Carlo method, losses of counts up to 100 million events per second (Meps) are calculated and the effective system dead time is estimated by curve fitting of a non-extendable dead time model to the results (τNE = 2.26 ns). An important dead time effect on a measured random process is the distortion on the time spectrum; using the Monte Carlo method this effect is also studied. The uncertainty of the system is analysed experimentally. The standard deviation of the system is estimated as ± 36.6 × T (T= 3.33 ns) for a one-second time interval test signal (300 million Tin the time interval).
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 601-619
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficient dead time correction of G-M counters using feed forward artificial neural network
Autorzy:
Arkani, M.
Khalafi, A.
Powiązania:
https://bibliotekanauki.pl/articles/146121.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dead time
artificial neural network (ANN)
Geiger-Müller (G-M) detector
hybrid model
source decaying experiment
Opis:
Dead time parameter of Geiger-Müller (G-M) counters causes a great uncertainty in their response to the incident radiation intensity at high counting rates. As their applications in experimental nuclear science are widespread, many attempts have been done on improvements of their nonlinear response. In this work, response of a G-M counter system is optimized and corrected efficiently using feed forward artificial neural network (ANN). This method is simple, fast, and provides the answer to the problem explicitly with no need for iteration. The method is applied to a set of decaying source experimental data measured by a fairly large G-M tube. The results are compared with those predicted by a given analytical model which is called hybrid model. The maximum deviation of the corrected results from the true counting rates is less than 4% which is a significant improvement in comparison with the results obtained by the analytical method. Results of this study show that by using a proper artificial neural network structure, the dead time effects of G-M counters can be tolerated significantly.
Źródło:
Nukleonika; 2013, 58, 2; 317-321
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An improved formula for dead time correction of G-M detectors
Autorzy:
Arkani, M.
Khalafi, H.
Powiązania:
https://bibliotekanauki.pl/articles/147009.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dead time model
Geiger-Müller (G-M) detector
decaying source experiment
hybrid model
Opis:
Different analytical formulae have been described in the literature to modify response of Geiger-Müller (G-M) detectors. In this work, improvement of a previously proposed dead time correction formula was investigated. A set of experimental data of a decaying source was the basis of the analysis. A general agreement is seen with the experimental data. The result was compared with those obtained by the original work. Numerical aspects were also examined.
Źródło:
Nukleonika; 2013, 58, 4; 533-536
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an embedded FPGA-based data acquisition system dedicated to zero power reactor noise experiments
Autorzy:
Arkani, M.
Khalafi, H.
Vosoughi, N.
Powiązania:
https://bibliotekanauki.pl/articles/220709.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zero power reactor (ZPR) noise
time interval measurement
probability distribution function (PDF)
field programmable gate array (FPGA)
data acquisition system (DAS)
nuclear reactor
neutron detection
Opis:
An embedded time interval data acquisition system (DAS) is developed for zero power reactor (ZPR) noise experiments. The system is capable of measuring the correlation or probability distribution of a random process. The design is totally implemented on a single Field Programmable Gate Array (FPGA). The architecture is tested on different FPGA platforms with different speed grades and hardware resources. Generic experimental values for time resolution and inter-event dead time of the system are 2.22 ns and 6.67 ns respectively. The DAS can record around 48-bit x 790 kS/s utilizing its built-in fast memory. The system can measure very long time intervals due to its 48-bit timing structure design. As the architecture can work on a typical FPGA, this is a low cost experimental tool and needs little time to be established. In addition, revisions are easily possible through its reprogramming capability. The performance of the system is checked and verified experimentally.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 433-446
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development and Experimental Validation of a Correlation Monitor Tool Based on the Endogenous Pulsed Neutron Source Technique
Autorzy:
Arkani, M.
Khalafi, H.
Vosoughi, N.
Khakshournia, S.
Powiązania:
https://bibliotekanauki.pl/articles/221446.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
endogenous pulsed neutron source experiment
neutron noise fluctuation
zero power reactor noise
Esfahan heavy-water zero power reactor
neutron correlation
Opis:
A correlation measuring tool for an endogenous pulsed neutron source experiment is developed in this work. Paroxysmal pulses generated by a bursts of neutron chains are detected by a 10-kbit embedded shift register with a time resolution of 100 ns. The system is implemented on a single reprogrammable device making it a compact, cost-effective instrument, easily adaptable for any case study. The system was verified experimentally in the Esfahan heavy-water zero power reactor (EHWZPR). The results obtained by the measuring tool are validated by the Feynman-α experiment, and a good agreement is seen within the boundaries of statistical uncertainties. The theory of the methods is briefly initiated in the text. Also, the system structure is described, the experimental results and their uncertainties are discussed, and neutron statistics in EHWZPR is examined experimentally.
Źródło:
Metrology and Measurement Systems; 2017, 24, 3; 441-461
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies