Wyszukujesz frazę "radon concentration measurement" wg kryterium: Wszystkie pola


Wyświetlanie 1-11 z 11
Tytuł:
Intercomparison of instruments for measuring radon and radon progeny held in the CLOR calibration chamber
Pomiary porównawcze stężenia radonu i jego pochodnych w komorze kalibracyjnej CLOR
Autorzy:
Mamont-Cieśla, K.
Stawarz, O.
Powiązania:
https://bibliotekanauki.pl/articles/340680.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
pomiar stężenia radonu
Centralne Laboratorium Ochrony Radiologicznej
miernik AlphaGUARD
kalibracja radiometru
radon concentration measurement
Central Laboratory of Radiological Protection
AlphaGUARD meter
radiometer calibration
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 90-92
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast measurement of radon concentration in water with Lucas cell
Autorzy:
Machaj, B.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/147981.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon in water
measurement
concentration
Opis:
Abstract Fast method of measurement of radon concentration in water based on flushing (bubbling) water sample with air in closed loop with Lucas cell is presented. The main feature of the method is washing radon from large sample of water to small volume of air including the volume of Lucas cell, thanks to which high radon concentration in the air and considerable sensitivity of measurement is achieved. Estimated measuring sensitivity is S = 8.5 cpm/(Bq/dm3). Random error due to statistical fluctuations of count rate at radon concentration 1, 100, 10 000 Bq/dm3 is: 11, 1.1, 0.1% correspondingly at counting (measuring) time 10 min. Minimum detectable radon concentration in water for such counting time is 0.11 Bq/dm3.
Źródło:
Nukleonika; 2004, 49, 1; 29-31
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of radon concentration in the air by PicoRad detectors
Autorzy:
Chau, N. D.
Powiązania:
https://bibliotekanauki.pl/articles/146088.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
PicoRad detectors
charcoal
adsorption
desorption
liquid scintillation
Opis:
The paper presents the theory and methodology of radon concentration measurement in the air by PicoRad detector, which consists of a porous canister held securely near the top of a plastic vial. The porous canister contains a bed of a controlled mass of charcoal (1.3 g) and silica desiccant (0.9 g). To measure the radon concentration, the vial detector is exposed in the radon laden air for a certain interval of time (24, 48 or 72 h or longer), then the liquid scintillation cocktail is added into the vial and measured by the help of a liquid scintillation counter. In this paper both radon adsorption by the charcoal detector, while it is being exposed in the radon laden air, and desorption of radon from the charcoal into the liquid scintillation cocktail were investigated. As a result, some conclusions concerning the methodology of radon measurement by PicoRad detectors have been done. The desorption factor of radon from the charcoal into the liquid scintillation cocktail was determined. The radon concentration values in the air measured by PicoRad detectors were in good agreement with those obtained by an AlphaGuard radon monitor.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 21-24
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of aerosol concentration and multivariate processing on the indication of radon progeny concentration in air
Autorzy:
Machaj, B.
Urbański, P.
Powiązania:
https://bibliotekanauki.pl/articles/147261.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon progeny
measurement
data processing
Opis:
Measurements of radon progeny concentration in air by a radon progeny monitor are sensitive to the concentration of particles suspended in air. Minimum detectable concentration and accuracy of the measurement are determined by random errors of the monitor. Multivariate data processing can be used to decrease these random errors. Influence of aerosol concentration on the measured results of radon progeny concentration in air, by an RGR-30 mining radiometer, operating on the principle of alpha radiation detection from radon progeny deposited on an air filter, were determined in a radon chamber experiment. The air suspended particle concentration and the radon concentration in the radon chamber were controlled and the corresponding radon progeny concentration was measured by the radon progeny monitor. Additionally, count rate from the monitor detector, originating from the alpha activity deposited on the air filter, was measured at intervals of one minute and was then used for the three-interval, and Principal Component Regression (PCR) data processing. It was found that for the aerosol concentration in air from 40 p/cm3 to approximately 9,000 p/cm3 indications of the radon progeny monitor depends considerably on the aerosol concentration. Radon daughter concentration normalized to the radon concentration against aerosol concentration varied from 0.3 to 0.9. In mines, where the aerosol concentration generally is high, this phenomenon has little effect on the indication of the radon progeny monitor. At low aerosols concentration, appropriate correction of radon progeny concentration has to be taken. Comparison of random errors when measured signal of the monitor (count rate against time) was processed employing the three-interval method and PCR data processing shows that PCR ensures a lower random error.
Źródło:
Nukleonika; 2004, 49, 3; 123-129
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of radon (222Rn) and thoron (220Rn) concentration with a single scintillation cell
Autorzy:
Machaj, B.
Urbański, P.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/146829.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
measurement
scintillation cell
Opis:
. A single scintillation cell (ö 54 × 74 mm) is used for the measurement of radon and thoron. The radon and thoron laden air is filtered and forced to flow at 1 dm3/min through the scintillation cell in the period of 1 10 min. The count number from alpha radiation is registered in the periods of 3 10 min and 20 30 min. Two values of detection and deposition efficiency of alpha radiation are used for radon (at air flow and air at rest in the cell) and for thoron. Measurements of radon laden air and thoron laden air showed good agreement between the reference concentration and the measured concentration, not worse than 1% for radon and not worse than 2% for thoron. Combination of radon + thoron concentration showed also a small interference ("cross talk") not worse than 1%.
Źródło:
Nukleonika; 2007, 52, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon measurement as a monitoring possibility for mining subsidence occurrences
Możliwość wykorzystania pomiarów dla wykrywania przypadków osiadania terenów górniczych
Autorzy:
Kies, A.
Storoni, A.
Tosheva, Z.
Powiązania:
https://bibliotekanauki.pl/articles/340794.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
stężenie radonu
nradon na terenach górniczych
radon concentration
radon in mining areas
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 115-117
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issues of radon (Rn-222) exhalation measurements
Problematyka pomiarów ekshalacji radonu (Rn-222)
Autorzy:
Modzelewska, D.
Dołhańczuk-Śródka, A.
Ziembik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/126822.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
radon
exhalation
concentration
measurement uncertainty
AlphaGUARD
ekshalacja
stężenie
niepewność pomiarowa
Opis:
The Rn-222 isotope, a naturally occurring radioactive gas, is created in a radioactive decay of Ra-226. Both radionuclides belong to the radium decay chain in which U-238 is the prime parent. Radon is usually in plenty found in the earth crust, rocks, soil, water and air, therefore it is regarded as an indicator of ionizing radiation dose received by a population. Due to radon negative influence on people’s health, measurements of its concentration are commonly performed. The presented research concerns assessment of measurements uncertainty of Rn-222 concentration exhaled from soil. The measurements were repeated at the same site. The experiment was carried out in natural conditions, in the city center and lasted about half a year. In Rn-222 concentration measurements the AlphaGUARD radon monitor was used. The device was operating in the 10-minutes flow mode, with the air pump and exhalation-box arranged in the closed cycle. The studies have shown a significant differences between results of radon exhalation measurements, which were carried out sequentially in the same place. Generally, increase in measurements number in a series lowers the result uncertainty. Consequently, the number of measurements in a series can be adjusted to the desired uncertainty of result. What is more, the distribution of the results in series is well described by the Poisson distribution.
Izotop Rn-222, naturalnie występujący radioaktywny gaz, powstaje na skutek rozpadu promieniotwórczego Ra-226. Oba radionuklidy należą do szeregu uranowo-radowego, który rozpoczyna U-238. Radon występuje w dużych ilościach w skorupie ziemskiej, skałach, glebie, wodzie i powietrzu, dlatego jest on traktowany jako wskaźnik dawki promieniowania jonizującego otrzymywanego przez ludzi. Ze względu na negatywny wpływ radonu na zdrowie ludzi pomiary stężenia tego gazu są często wykonywane. Zaprezentowano wyniki badań niepewności pomiarowej stężenia Rn-222 w powietrzu ekshalowanym z gleby. Pomiary powtarzano wielokrotnie w tym samym miejscu. Eksperyment przeprowadzony został w warunkach naturalnych, w centrum miasta i obejmował okres około pół roku. Do pomiarów stężenia radonu wykorzystano monitor radonowy AlphaGUARD. Pracował on w 10-minutowym trybie przepływowym, z pompą oraz komorą ekshalacyjną w obiegu zamkniętym. Badania wykazały znaczne różnice pomiędzy wynikami pomiarów, wykonywanych w całym okresie badawczym. W pojedynczej serii większa liczba pomiarów zmniejsza niepewność pomiarową. Dzięki temu ilość pomiarów w serii może być dostosowana do oczekiwanej niepewności pomiarowej wyniku. Stwierdzono, że rozkład wyników aktywności radonu w serii jest dobrze opisywany przez rozkład Poissona.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 409-415
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polish national intercomparisons of measurement methods of 222Rn concentration in waters
Krajowe pomiary interkalibracyjne stężenia 222 Rn w próbkach wód
Autorzy:
Przylibski, T.
Mamont-Cieśla, K.
Stawarz, O.
Kłos, B.
Dorda, J.
Powiązania:
https://bibliotekanauki.pl/articles/340341.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
intercomparison measurement
radon contamination
radiological protection in Poland
Radon Centre
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 71-73
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of seasonal indoor radon concentration in Sakarya University, Turkey
Autorzy:
Zenginerler, Z.
Ertugral, F.
Yakut, H.
Tabar, E.
Demirci, N.
Gunermelikoglu, K.
Powiązania:
https://bibliotekanauki.pl/articles/1065299.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.-n
27.90.+b
Opis:
Indoor radon measurements were performed using LR-115 type-II solid state nuclear track detectors in Sakarya University in classrooms, laboratories and offices during the period from July 2013 to June 2014. The results show that the radon concentration in studied buildings ranges from 0.20±0.04 to 94.1±10 Bq/m³ with an average value of 40±5 Bq/m³. The annual effective doses from radon were estimated to range from 0.18 to 2.00 mSv/y with a mean value of 1.00 mSv/y. These results indicate no radiological health hazard, as the measured activities are well below International Commission on Radiological Protection recommended level of 200 Bq/m³ for indoor radon.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 450-452
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber
Autorzy:
Stawarz, O.
Karpińska, O.
Mamont-Ciesla, K.
Powiązania:
https://bibliotekanauki.pl/articles/148604.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
activated charcoal
relative humidity
duration of exposure
PicoRad system
Opis:
PicoRad system based on activated charcoal collectors and liquid scintillation counter is one of the most popular passive methods of radon measurements which may be used both indoors and in other environments such as caves, tunnels, mines etc. It is well known that charcoal is also a very good adsorber of water vapor and it can reduce adsorption efficiency for radon. In PicoRad collectors, the charcoal is mixed with a dessicant to lower this effect. A series of expositions of PicoRad detectors was performed in a Central Laboratory for Radiological Protection (CLOR) radon calibration/climatic chamber to study the effect of high relative humidity on the airborne radon concentration measurements and the dependence of the results on the duration of exposure. The results obtained from the PicoRad system were referred to the mean concentrations delivered by an AlphaGUARD monitor, Genitron (GmbH), Germany. The main conclusions are the following: 1) the PicoRad system results are not affected by high relative humidity, including extreme values of 90-96%, for the duration of exposure up to ca. 24 h; 2) in the relative humidity range of 75-96% the correction coefficient linearly depends on the duration of exposure reaching a value of ca. 16 for 96 h exposure; 3) the PicoRad system delivers results corresponding better to the mean value of radon concentration in the last 6 h interval of exposure than that in the whole exposure duration. This finding is particularly important for the calibration of PicoRad collectors in the conditions of decreasing radon concentration due to radon decay.
Źródło:
Nukleonika; 2006, 51,suppl.2; 53-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
First results of measurement of equilibrium factors F and unattached fractions fp of radon progeny in Czech dwellings
Autorzy:
Jílek, K.
Thomas, J.
Tomášek, L.
Powiązania:
https://bibliotekanauki.pl/articles/148749.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
unattached fraction
dose
indoor aerosol concentration
rural/urban area
day/night
Opis:
The unattached fraction of radon decay product clusters fp and equilibrium factor F are dose relevant parameters in all dosimetric approaches to dose calculation. In the past, three year continuous weekly measurements of unattached and attached activity of radon daughter product and air exchange rate were carried out during heating season in 30 occupied typical Czech family houses. The results indicated significantly different weekly averages of equilibrium factor F and fp for houses located in towns compared those in villages. Due to this fact, approximately a 10 per cent average increase of equivalent lung dose rate was estimated in the detriment in towns. Average values of equilibrium factor F and fp were 0.40 and 8.6 per cent in urban houses and 0.32 and 10.7 per cent, respectively in rural houses. Based on the measurements of mean values of fp, average effective dose conversion factors (DFC) in units of mSv per working level month (WLM) were estimated to be 15.0 mSv/WLM in urban houses and 15.9 mSv/WLM in rural houses, respectively.
Źródło:
Nukleonika; 2010, 55, 4; 439-444
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies