- Tytuł:
-
Aspekty metrologiczne doboru materiałów sorpcyjnych przy oznaczaniu olejów przenikających przez rękawice ochronne metodą spektrofotometrii absorpcyjnej w nadfiolecie
Metrological aspects of the sorptive material selection used to trace reference oils permeating thorough protective gloves by means of UV absorption spectrophotometry method - Autorzy:
-
Irzmańska, E.
Kamińska, W.
Dyńska-Kukulska, K.
Grzegorczyk, E. - Powiązania:
- https://bibliotekanauki.pl/articles/152640.pdf
- Data publikacji:
- 2010
- Wydawca:
- Stowarzyszenie Inżynierów i Techników Mechaników Polskich
- Tematy:
-
właściwości ochronne
rękawice ochronne
oleje mineralne
przenikanie
medium stałe
ocena statystyczna
protective properties
protective gloves
mineral oils
permeability
solid medium
statistical evaluation - Opis:
-
Przedstawiono metodę oznaczania olejów za pomocą spektrofotometrii absorpcyjnej w nadfiolecie. Przeprowadzono badania mające na celu dobranie stałego środka sorpcyjnego charakteryzującego się wysokim współczynnikiem odzysku tych substancji. W tym celu zastosowano obliczenia statystyczne stosowane w metrologii chemicznej pozwalające na stwierdzenie, że opracowana metoda badawcza charakteryzuje się dobrą precyzją. Procedura analityczna charakteryzuje się również odpowiednią dokładnością, o czym świadczą małe wartości względnego błędu przypadkowego wartości średniej U'A. Wyznaczone wartości współczynników odzysku są bliskie wartości 100%, a wartości odchylenia standardowego i współczynników zmienności świadczą o precyzji metody. Względne błędy przypadkowe wartości średniej U'A współczynników odzysku są mniejsze, niż 10%, co świadczy o przydatności metody do tego typu oznaczeń.
At present, there are no testing methods in the country which would permit to evaluate protective gloves, regarding their resistance to glue/adhesive permeability. At present, the efficacy of gloves' protection levels against chemical substances is assessed experimentally, in accordance with a normalized procedure, described in PN-EN 374-3:2005 standard. Taking into consideration the fact that hydrocarbons are the main oil components, neither gas nor water-based collecting medium can be used in a permeability chamber. In this situation, a selection of an appropriate solid medium would seem an optimal solution. However, neither accurate testing procedures nor result calculation methods have been designed and adapted for this particular purpose. The goal of the study was an evaluation of the analytical parameters of the designed test procedure and the definition of the attributes of the obtained statistical results. The scope of the study included a selection of solid collecting media and of reference oils; an optimization of reference oil sorption process on the selected solid medium, sample extraction methods and a quantitative estimation of the relation expressed by the recovery index. The results indicate that the designed method is appropriately precise and accurate, which is evidenced by the small values of the relative chance error of the U'A mean value. The determined values of recovery indices are close to 100%, while SD and variation index values are indicative of the method's precision. Relative random errors of the U'A mean value of recovery indices are < 10%, which is the best evidence for the usefulness of the method for such measurements. - Źródło:
-
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 883-886
0032-4140 - Pojawia się w:
- Pomiary Automatyka Kontrola
- Dostawca treści:
- Biblioteka Nauki