Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "quality measurements" wg kryterium: Temat


Tytuł:
Improving environmental odor measurements : comparison of lab-based standard method and portable odor measurement technology
Autorzy:
Maurer, D. L.
Bragdon, A. M.
Short, B. C.
Ahn, H.
Koziel, J. A.
Powiązania:
https://bibliotekanauki.pl/articles/204983.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odor
volatile organic compounds
air quality measurements
standardization
olfactometry
Opis:
Current standard odor measurement methods are lab-based and require substantial investment in hardware, sample collection, training, and maintenance. Odor samples must be collected in the field using bags and brought to the lab to test. This can be a time-consuming process, with the possibility of the sample loss. The actual odor measurements are based on dilution olfactometry, embodied in the AC’SCENT® International Olfactometer, following the ASTM E679-04 standard. In recent years a portable olfactometer, the Scentroid SM100i, has been developed for odor measurements. The portable olfactometer has many advantages over lab-based standard method, especially the lower cost-per-sample. However, very little is known about the performance and reliability of portable olfactometer where the dilutions are controlled with orifices in metallic plates. It is important to evaluate the Scentroid SM100i accuracy to determine the usefulness of using it as a comparable technology for odor measurements. The main objective of this research is to compare the performance of the lab-based ASTM E679-04 method with portable odor measurement technology. Specific objectives include: (1) determining the accuracy of the dilution ratios specified by the manufacturer of both the AC’SCENT International Olfactometer and the Scentroid SM100i; (2) comparing results between olfactometers using n-butanol, a commonly used standard gas in the olfactometry field, and (3) determining the accuracy of odor measurement using real odor samples collected from livestock farms in Iowa. The AC’SCENT olfactometer had an average percent error between the factory specifications and measured dilution ratios of 5.23% compared with 14.1% for Scentroid SM100i (using plate i-2 with dilution range most comparable to the AC’SCENT olfactometer). The use of other dilution plates resulted in average percent errors ranging from 9.68% to 25.31%. The Scentroid SM100i deviated from the manufacturer specifications for flowrates and dilution ratios, but these flowrates were generally consistent with each dilution setting. Overall, the Scentroid SM100i overestimated the odor concentrations with the mean difference of 22.9% (ranging from 0.95% to 93.34%). When the post-measurement adjustment using dilution correction was made, the mean percent average difference was 11.8%.
Źródło:
Archives of Environmental Protection; 2018, 44, 2; 100-107
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of multimedia applications in a cluster-oriented environment
Autorzy:
Czarnul, P.
Dziubich, T.
Krawczyk, H.
Powiązania:
https://bibliotekanauki.pl/articles/220601.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quality measurements
software quality
quality model and measures
parallel computing
distributed middleware
multimedia applications
Opis:
In the age of Information and Communication Technology (ICT), Web and the Internet have changed significantly the way applications are developed, deployed and used. One of recent trends is modern design of web-applications based on SOA. This process is based on the composition of existing web services into a single scenario from the point of view of a particular user or client. This allows IT companies to shorten the producttime to market process. On the other hand, it raises questions about the quality of the application, trade-offs between quality factors and attributes and measurements of these. Services are usually hosted and executed in an environment managed by its provider that assures the quality attributes such as availability or throughput. Therefore, in this paper an attempt has been made to perform quality measurements towards the creation of efficient, dependable and user-oriented Web applications. First, the process of designing service-based applications is described. Next, metrics for subsequent measurements of efficiency, dependability and usability of distributed applications are presented. These metrics will assess the efforts and trade-offs in a Web-based application development. As examples, we describe a pair of multimedia applications which we have developed in our department and executed in a cluster-based environment. One of them runs in the BeesyCluster middleware and the second one in the Kaskada platform. For these applications we present results of measurements and conclude about relations between quality attributes in the presented application development model. This knowledge can be used to reason about such relations for new similar applications and be used in rapid and quality development of the latter.
Źródło:
Metrology and Measurement Systems; 2012, 19, 2; 177-190
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of Voltage Harmonics in 400 kV Transmission Network
Pomiary wyższych harmonicznych napięcia w sieci 400 kV
Autorzy:
Pawełek, R.
Wasiak, I.
Jurek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397094.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
voltage harmonics
power quality
power quality measurements
wyższe harmoniczne
jakość energii elektrycznej
pomiary jakości energii elektrycznej
Opis:
The paper deals with the analysis of voltage harmonics measurements performed in the 400 kV transmission network. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.
W artykule przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia, wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne, odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
Źródło:
Acta Energetica; 2014, 2; 127-134
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary wyższych harmonicznych napięcia w sieci 400 kV
Measurements of voltage harmonics in 400 kV transmission network logic
Autorzy:
Pawełek, R.
Wasiak, I.
Błajszczak, G.
Jurek, M.
Olak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267443.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyższe harmoniczne
jakość energii elektrycznej
pomiary jakości energii elektrycznej
voltage harmonics
power quality
power quality measurements
Opis:
Przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
The paper deals with the analysis of voltage harmonics measurements performed in the transmission network of 400 kV. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 139-142
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany nieustalone towarzyszące pomiarowi impedancji pętli zwarcia w obwodach wyjściowych zasilaczy bezprzerwowych UPS
Transient states associating loop impedance measurement in the output line of UPS power supplies
Autorzy:
Olesz, M.
Katarzyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/266602.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stany nieustalone
zasilacze bezprzerwowe
pomiary jakości energii elektrycznej
impedancja pętli zwarcia
transients
uninterruptible power supplies
power quality measurements
fault loop impedance
Opis:
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem wielokanałowym potwierdziły poprawność danych uzyskiwanych w celu określenia reakcji zasilacza na zaburzenia występujące na wejściu i wyjściu urządzenia. W pracy analizowano wyniki pomiarów impedancji pętli zwarciowej zmierzone przyrządem wymuszającym poziomy prądu zwarciowego na linii zasilającej odbiorniki energii elektrycznej we wszystkich stanach pracy zasilacza, a następnie porównywano je z wynikami obliczeń przeprowadzonych na uzyskanych przebiegach prądu i napięcia.
The paper presents the methodology and the results of transient measurement in on-line Uninterruptable Power Supply (UPS). There were two power quality measurement instruments (synchronised with time) used for registering the events in UPS input and output. The recorders compress the obtained measurement data, which may introduce additional measurement errors of measured values, i.e. voltage and current. Additional registrations with a multi-channel oscilloscope confirmed the correctness of the obtained data in order to determine the reaction of the UPS to the disturbances occurring in UPS input and output. The work analysed the results of loop impedance, measured by a meter that forces short-circuit current in the line supplying electric load, in all states of the UPS, and then they were compared with the results of calculations carried out on the obtained current and voltage waveforms. The measurement of fault loop impedance in UPS output line should be performed in active static switch (bypass mode), because UPS will operate in this mode after switching from inverter operation due to high current forcing during a short circuit in the UPS output. Measurement of fault loop impedance in UPS output circuits, when it is in AC-DC-AC double conversion mode, may result with loop impedance overstating by meters, which in turn limits recognition of the tested installation as safe from the protection against electric shock by automatic power off point of view. The values of calculated loop impedance at forced high current, i.e. 160 A in the UPS output, when it is respectively in the manual bypass and static switch mode, are 4% and 2.5% lower than the ones presented by meter after measure by forcing high current. Differences in impedance of the static switch and manual bypass UPS mode can be the basis for the estimation of the thyristor impedance. Estimation of direct measurement results with 14.6 m, and according to the calculation of recorded transients it is about 16.1 m.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 61; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short time algorithm of power waveforms fundamental harmonic estimation with use of pronys methods
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221769.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony's method
harmonics
measurements
Opis:
This paper presents an example of practical use of Prony's method for monitoring of power waveform fundamental harmonic fluctuations, which is required for the analysis of window synchronizations in frequency analyses in power monitoring systems. The example presented offers verification of the authors' theoretical considerations published earlier in articles about Prony's method and its opportunities for practical use for real life signals. The investigations shown are based on the least squares Prony's method, which, in connection with digital filtrations, enables estimations of fundamental frequency at the rate of even tens of times per one fundamental harmonic period.
Źródło:
Metrology and Measurement Systems; 2011, 18, 3; 371-378
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variable-frequency Prony method in the analysis of electrical power quality
Autorzy:
Zygarlicki, J.
Mroczka, J.
Powiązania:
https://bibliotekanauki.pl/articles/221630.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
Prony method
harmonics
measurements
Opis:
The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 39-48
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automation of technological processes in a coal preparation plant and useful systems and devices for monitoring of coal quality
Automatyzacja procesów technologicznych w zakładach mechanicznej przeróbki przydatne w tym zakresie systemy i urządzenia do monitorowania jakości węgla
Autorzy:
Sikora, T.
Będkowski, Z.
Smyła, J.
Powiązania:
https://bibliotekanauki.pl/articles/348603.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
automatyka
wzbogacanie węgla
pomiary parametrów jakościowych węgla
coal preparation
automation
measurements of basic coal quality parameters
Opis:
The paper presents works carried out at the Institute of Innovative Technology EMAG for the automation of the chosen processes of coal preparation, such as coal preparation in heavy media or in jigs, among others in terms of the process efficiency, minimizing of the loss of carbon in the waste and improvement of the quality of preparation products. The paper describes also systems and devices for coal quality measurement developed at the Institute, both for continuous and laboratory measurement, useful in monitoring of processes and basic quality parameters of coal and enrichment products for example System ALFA-06 for on-line measurement of the ash and moisture content in coal and Laboratory Analyzer GAMMA NATURA.
W referacie przedstawiono prace realizowane w Instytucie Technik Innowacyjnych EMAG w zakresie automatyzacji wybranych procesów wzbogacania węgla m.in. wzbogacania w cieczy ciężkiej czy w osadzarkach, w tym, w aspekcie zwiększenia wydajności procesów, zminimalizowania strat węgla w odpadach czy poprawy jakości produktów wzbogacania. Omówiono także opracowane w Instytucie systemy i urządzenia do pomiaru jakości węgla, zarówno do pomiarów ciągłych jak i laboratoryjnych, przydatne w monitorowaniu przebiegu procesów i kontroli podstawowych parametrów jakościowych węgla i produktów jego wzbogacania np. system ALFA-06 do ciągłego pomiaru zawartości popiołu i wilgoci w węglu czy analizator węgla GAMMA NATURA.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 309-323
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy of drying selected products using a moisture analyzer method based on infrared radiation
Autorzy:
Janas, Sławomir
Kowalska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/27311743.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
moisture analyser
infrared heating
food quality
mass measurements
Opis:
Trueness and precision of a method for determining the water content (%) of food and chemical products based on infrared radiation with a wavelength in the range (2.70÷7.21 μm) was evaluated. The most accurate measurements for food products were obtained when the heat source was a radiant heater with a radiation wavelength of 7.21 μm, a trueness deviation of 0.01%. When heated with radiation with wavelengths (from 3.32 μm to 7.21 μm), the trueness of the measurement ranged (0.03%÷0.13%) for chemical products. The shortest analysis time for food products was found when the analysis was carried out using an IR source with a wavelength of 7.21 μm, while for chemical products, a heat source with a wavelength of 2.70÷7.21 μm was optimal. According to the results of the analysis, the use of IR radiation with a wavelength range of 3.32÷7.21 μm is an alternative for accurate measurements.
Źródło:
Metrology and Measurement Systems; 2023, 30, 2; 305--321
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities for determining the interference between a power supply network and a converter fed drive
Autorzy:
Beniak, R.
Gardecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193393.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
power quality
converter drives
voltage and current measurements
Opis:
Measuring instruments, measurement methods, and an exemplary analysis of the impact of chosen operating stages of the converter drive on the power supply network have been presented. The measurements of electrical and mechanical parameters in drive systems used in industry are complex. The task is difficult due to the necessity of connecting a measuring instrument into electric circuits of an active facility with the use of only short non-operational periods of the device. However, a wellchosen model of a drive system allows the multivariate research of the impact of drive parameters and a control algorithm used on voltage and current harmonic content and performance of the system, and therefore on a simulation analysis of the impact of the drive on the power supply network.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 17-26
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rejestracja przepięć w instalacjach elektroenergetycznych
Overvoltages recording in electrical networks
Autorzy:
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/267427.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przepięcia
jakość energii elektrycznej
overvoltages
power quality
measurements
Opis:
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w instalacjach zasilających niskiego napięcia (nn) dwóch wybranych zakładów przemysłowych. Dodatkowo podano zestawienie rejestracji stanów przepięciowych towarzyszących zwarciom po stronie średniego napięcia (SN) zmierzonych poprzez przekładniki napięciowe przyłączone do szyn SN w stacji transformatorowej dwustronnie zasilanej. We wszystkich przypadkach uzyskiwano dane wystarczające dla określenia poprawności doboru odporności urządzeń zawierających wyposażenie elektroniczne do poziomu przepięć występujących w instalacji.
The paper presents methods of measurement and some records of transients in LV networks supplying two selected industrial plants. Additionally, records of overvoltages via the voltage instrument transformer in the MV two-side-supplied transformer station due to short-circuits have been presented. In all cases, the acquired data are sufficient for proper selection of immunity of appliances equipped with electronic devices to overvoltages occurring in real networks.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 105-110
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the Influence of Network Impairments on YouTube Video Streaming
Autorzy:
Biernacki, A.
Metzger, F.
Tutschku, K.
Powiązania:
https://bibliotekanauki.pl/articles/309310.pdf
Data publikacji:
2012
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
multimedia communication
network measurements
quality of service
video streaming
Opis:
Video sharing services like YouTube have become very popular which consequently results in a drastic shift of the Internet traffic statistic. When transmitting video content over packet based networks, stringent quality of service (QoS) constraints must be met in order to provide the comparable level of quality to a traditional broadcast television. However, the packet transmission is influenced by delays and losses of data packets which can have devastating influence on the perceived quality of the video. Therefore, we conducted an experimental evaluation of HTTP based video transmission focusing on how they react to packet delay and loss. Through this analysis we investigated how long video playback is stalled and how often re-buffering events take place. Our analysis revealed threshold levels for the packet delay, packet losses and network throughput which should not be exceeded in order to preserve smooth video transmission.
Źródło:
Journal of Telecommunications and Information Technology; 2012, 3; 83-90
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innovative application of quality methods in the homogeneity assessment of the F-16 aircraft group in terms of generated noise
Autorzy:
Misztal, Agnieszka
Szymanski, Grzegorz M.
Misztal, Wojciech
Komorski, Pawel
Powiązania:
https://bibliotekanauki.pl/articles/2087027.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
noise measurements
F-16 aircraft
homogeneity assessment
quality control methods
Opis:
Given the high-power concentration of combustion engines used in military aviation, it is reasonable to measure the instantaneous surges in the sound pressure level. Therefore, a research question was raised regarding the differences in this level for various aircraft engines of the same type (F100-PW-229) to assess their size and statistical significance. The aim of the paper is to discuss the attempt to check the significant difference between the parameters of the acoustic level generated by the aircraft engines. The measurements were carried out for 32 engines of the F-16 Block 52+ multirole aircraft during takeoff process. The parameters of noise in the point system and in the octave distribution were subject to analysis. Statistical methods dedicated to assessing production stability, i.e. the Shewhart chart, were applied. The results of the analysis showed that the discrepancies generally do not exceed a value of +/− 3σ . Therefore, it can be concluded that the analogous results for F-16 noise are homogeneous. Thus, the Shewhart chart method proved useful for assessing the homogeneity of these measurements.
Źródło:
Eksploatacja i Niezawodność; 2022, 24, 2; 187--199
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies