- Tytuł:
- Non-uniformity correction in microbolometer array with temperature influence compensation
- Autorzy:
-
Krupiński, M.
Bieszczad, G.
Sosnowski, T.
Madura, H.
Gogler, S. - Powiązania:
- https://bibliotekanauki.pl/articles/221147.pdf
- Data publikacji:
- 2014
- Wydawca:
- Polska Akademia Nauk. Czytelnia Czasopism PAN
- Tematy:
-
microbolometer
non-uniformity correction - Opis:
- In the article a non-uniformity correction method is presented which allows to compensate for the influence of detector’s temperature drift. For this purpose, dependency between output signal value and the temperature of the detector array was investigated. Additionally the influence of the temperature on the Offset and Gain coefficients was measured. Presented method utilizes estimated dependency between output signal of detectors and their temperature. In the presented method, the shutter is used for establishing signal reference. Thermoelectric cooler is used for changing the temperature of the detector array.
- Źródło:
-
Metrology and Measurement Systems; 2014, 21, 4; 709-718
0860-8229 - Pojawia się w:
- Metrology and Measurement Systems
- Dostawca treści:
- Biblioteka Nauki