Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "membrane structure" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
FEM-BEM coupling in the membrane structure-air interaction problem
Połączenie MES i MEB w zagadnieniach interakcji powłok membranowych i powietrza
Autorzy:
Sygulski, R.
Powiązania:
https://bibliotekanauki.pl/articles/281304.pdf
Data publikacji:
1998
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
finite element method
boundary element method
membrane structure
Opis:
This paper deals with the interaction problems between the lightweight membrane structure and surrounding air. The coupling of FEM and BEM is described and applied to analysis of aerodynamics of membrane structures. Three methods of FEM-BEM coupling are presented.
Praca dotyczy problemów interakcji lekkich przekryć membranowych i otaczającego powietrza. Omawia się połączenie metody elementów skończonych (MES) i metody elementów brzegowych (MEB) do analizy zagadnień aerodynamiki powłok membranowych. Przedstawiono trzy metody połączenia MES i MEB.
Źródło:
Journal of Theoretical and Applied Mechanics; 1998, 2; 513-520
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projektowanie zadaszeń membranowych na przykładzie parkingu rowerowego w Jaworznie
Membrane canopy designing on the example of a parking lot in Jaworzno
Autorzy:
Gerlic, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1848267.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
przekrycie membranowe
konstrukcja napięta
projektowanie architektoniczne
forma
membrane structure
tensile structure
architectural design
form
Opis:
W artykule przedstawiono wybrane zagadnienia związane z projektem oraz realizacją zadaszenia parkingu rowerowego w Jaworznie. To szerokie studium przypadku zawiera zarówno inspiracje projektowe, jak i ocenę zrealizowanego obiektu. Szczególną uwagę zwrócono na zagadnienia istotne dla architekta, a zwłaszcza na kształtowanie napiętej membrany. W dostępnej literaturze zagadnienia te są ograniczane do metod obliczeniowych. Natomiast prawidłowe funkcjonowanie zadaszenia musi być powiązane z otoczeniem i zagospodarowaniem.
The article presents selected issues related to the design and realization of a roof for a bicycle parking lot in Jaworzno. This extensive case study includes both design inspiration and an evaluation of the completed facility. Particular attention was paid to issues important to the architect, especially the form finding of a tensile membrane. In the available literature, these issues are limited to computational methods. On the other hand, the proper functioning of the roof must be related to the surroundings and development.
Źródło:
Builder; 2021, 25, 7; 12-15
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical behaviour of the implant used in human hernia repair under physiological loads
Autorzy:
Szepietowska, K.
Lubowiecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/307096.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
finite element modelling
hernia repair
implants
membrane structure
metoda elementów skończonych
implanty
konstrukcja membranowa
Opis:
In laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element Method. Two models are analysed: in the first one interaction between the mesh and a fascia is taken into account, in the second this interaction is not considered. Computations are conducted for two different material types of the implants: one with isotropic properties and second one with orthotropic properties. The models are validated by comparing dynamic numerical analysis with experimental outcomes, where load was simulating intraabdominal pressure during postoperative cough. Due to displacements of joints during activities like bending sideways or torsion of an abdomen, influence of kinematic extortions on forces in the joints is analysed. The outcome shows that position of the orthotropic implants is crucial and may strongly change the level of forces in the joints.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 89-96
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie polimerowych membran do dozowania substancji
Use of polymer membranes for material dosage
Autorzy:
Jaworska, P.
Trusek-Hołownia, A.
Powiązania:
https://bibliotekanauki.pl/articles/2071758.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nośnik leków
struktura alginianowo-membranowa
kontrola transportu
drug delivery system
alginate-membrane structure
delivery control
Opis:
Celem pracy było doświadczalne wykazanie na przykładzie substancji modelowej - witaminy B12 (cyjanokobalaminy) możliwości wykorzystania membran do kontrolowanego spowolnienia transportu masy. Sam alginian sodu w niewystarczający sposób reguluje tempo uwalniania substancji organicznych. Przez zastosowanie porowatych membran polimerowych z octanu celulozy czy też z polieterosulfonu transport masy spowolniono kilkaset razy, przybliżając wartość strumienia masy do wartości oczekiwanych przy transporcie leków.
The aim of this paper was to prove experimentally, based on model organ compound - vitamin B12 (cyanocobalamin), the possibility of membrane application in the controlled slowdown of mass transport. A sodium alginate alone does not control sufficiently the rate of organic compound release The mass transport was slowed down several hundred times using porous, polymer membranes made of cellulose acetate or polyethersulfone, achieving mass stream values expected in drug delivery.
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 4; 131-132
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia projektowania i realizacji konstrukcji membranowych
Selected issues in the design and construction of membrane structures
Autorzy:
Kowal, A.
Powiązania:
https://bibliotekanauki.pl/articles/163707.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja membranowa
projektowanie
procedura formfinding
rozkład sił
ugięcie membrany
cable and membrane structure
designing
formfinding procedure
force distribution
membrane deflection
Opis:
Na przykładzie realizacji projektu zadaszenia peronów Dworca PKP we Wrocławiu w pracy przedstawiono aktualną problematykę projektowania membran tekstylnych w budownictwie.
On the example of a project involving the roofing of platforms at Wrocław rail station, current issues are presented relating to the design of textile membranes in construction.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 123-125
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure, function, and regulation of myosin 1C.
Autorzy:
Barylko, Barbara
Jung, Gwanghyun
Albanesi, Joseph
Powiązania:
https://bibliotekanauki.pl/articles/1041416.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
myosin 1
membrane protein translocation
domain structure
Opis:
Myosin 1C, the first mammalian single-headed myosin to be purified, cloned, and sequenced, has been implicated in the translocation of plasma membrane channels and transporters. Like other forms of myosin I (of which eight exist in humans) myosin 1C consists of motor, neck, and tail domains. The neck domain binds calmodulins more tightly in the absence than in the presence of Ca^(2+). Release of calmodulins exposes binding sites for anionic lipids, particularly phosphoinositides. The tail domain, which has an isoelectic point of 10.5, interacts with anionic lipid headgroups. When both neck and tail lipid binding sites are engaged, the myosin associates essentially irreversibly with membranes. Despite this tight membrane binding, it is widely believed that myosin 1C docking proteins are necessary for targeting the enzyme to specific subcellular location. The search for these putative myosin 1C receptors is an active area of research.
Źródło:
Acta Biochimica Polonica; 2005, 52, 2; 373-380
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compression of berry-like cell between two plates - role of internal stress
Autorzy:
Blahovec, J.
Posva, J.
Powiązania:
https://bibliotekanauki.pl/articles/25043.pdf
Data publikacji:
1996
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
internal structure
berry-like fruit
compression
internal stress
membrane
plant cell
fleshy fruit
plant tissue
Źródło:
International Agrophysics; 1996, 10, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Buildings of the John Paul II Center – a challenge for civil engineering and architecture
Obiekty budowlane Centrum Jana Pawła II – wyzwanie dla budownictwa i architektury
Autorzy:
Wrana, Bogumił
Wrana, Jan
Powiązania:
https://bibliotekanauki.pl/articles/390637.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
John Paul II Centre in Cracow
limestone sediments
reinforced concrete CFA-type drilled piles
reiforced concrete frame and membrane structure
natural material solutions
respect for context and identity of the place
Centrum Jana Pawła II w Krakowie
osady wapienne
żelbetowe pale wiercone typu CFA
konstrukcja szkielet żelbetowy ramowo-powłokowy
rozwiązania z naturalnego materiału
poszanowanie kontekstu i tożsamości miejsca
Opis:
The buildings of the John Paul II Centre (CJPII) are located in Cracow-Łagiewniki on a heap of limestone sediments from the former "Solvay" Sodium Plant in Cracow. The area is called "White Seas" (Białe Morze) and is located in the natural depression of the Wilga river valley, between Św. Józefa hill in the north and Borkowska Hill (Góra Borkowska) in the south-west. The limestone sediments as a building substrate for CJPII buildings is unprecedented ground in the world and thus a challenge for civil engineering. The height of the heap reaches about 15 m and has retained the consistency of a white pulp until today. CJPII buildings are objects of the third geotechnical category, founded on a foundation slab of 0.8-m thickness, and in the central part of 0.45-m thickness. The slab is based on 200 reinforced concrete CFA-type drilled piles with a diameter of 1000 mm and 650 mm and length up to 26 m. The load-bearing structure of the CJPII buildings is a reinforced concrete frame and shell structure. The symbolism of the urban complex (e.g. the scale of the market square in Wadowice), located on a system of 200 piles above the post-industrial landfill/heaps of sediments, is ensured with architectural solutions referring to places connected with the life of John Paul II – during the occupation in 1940-1944 he was a student of Jagiellonian University in Cracow and the worker of the Solvay factory in the Podgórze district, in 1958 he became a bishop of Cracow, in 1967 – the cardinal (architectural details from the St. Mary Church and the Wawel Cathedral), 1978-2005 – the pilgrim-pope from Rome, who confirmed the mission of the Church continuing the tradition depicted in the early-christian churches on the wall mosaics (the Basilica of San Vitale and the Basilica of Sant’ Apollinare Nuovo in Ravenna).
Obiekty budowlane Centrum Jana Pawła II (CJPII) znajdują się w Krakowie-Łagiewnikach na hałdzie osadów wapiennych z dawnych Krakowskich Zakładów Sodowych „Solvay”. Obszar ten nosi nazwę „Białe Morze” i został zlokalizowany w naturalnym obniżeniu doliny rzeki Wilgi, pomiędzy wzniesieniem św. Józefa na północy, a Górą Borkowską na południowym zachodzie. Osadnik wapienny jako podłoże budowlane dla budynków CJPII jest niespotykanym w świecie gruntem i stąd stał się wyzwaniem dla inżynierii lądowej. Wysokość osadnika hałdy sięga ok. 15 m, do dziś zachował on konsystencję pulpy koloru białego. Budynki CJPII to obiekty trzeciej kategorii geotechnicznej, posadowione na płycie fundamentowej grubości 0.8 m, a w części środkowej o grubości 0.45 m. Płyta oparta jest na 200 żelbetowych palach wierconych typu CFA o średnicy 1000 mm oraz 650 mm i długości do 26 m. Konstrukcja nośna budynków CJPII to żelbetowy szkielet ramowo-powłokowy. Symbolikę założenia urbanistycznego CJPII (wraz z placem w skali rynku w Wadowicach przed Sanktuarium), które usytuowano na płycie w sieci 200 pali nad odpadem poprodukcyjnym/hałdami jego osadu, zapewniają detale architektoniczne odnoszące się do miejsc związanych z życiem Jana Pawła II – podczas okupacji w latach 1940-1944 studenta UJ i robotnika fabryki Solvay w dzielnicy Podgórze, od 1958 r. biskupa krakowskiego, od 1967 r. kardynała (detale Katedry Wawelskiej oraz Kościoła Mariackiego), w latach 1978-2005 „papieża-pielgrzyma” z Rzymu, utrwalającego misję Kościoła kontynuującego tradycję przedstawianą w świątyniach wczesnochrześcijańskich na ściennych mozaikach (Bazylika San Vitale i Bazylika Sant’ Apollinare Nuovo w Rawennie).
Źródło:
Budownictwo i Architektura; 2020, 19, 4; 109-124
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lithium-Ion Conductive Film Membrane of Li0.3La0.57TiO2 Perovskite Structure and its Application in Li-Air Batteries
Autorzy:
Rhee, Chang-Kyu
Chun, Young-Bum
Kang, Suk Hoon
Kim, Whung-Whoe
Cao, G.
Powiązania:
https://bibliotekanauki.pl/articles/2203738.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lithium-ion conductive film
membrane
Li0.3La0.57TiO2
perovskite structure
Li-air batteries
Opis:
Impacts of precursor solution recipe, processing parameters, and pellet thickness on the lithium ionic conductivity of the ceramic materials with perovskite structure of Li0.3La0.57TiO3 were investigated and new method was proposed to synthesize Li0.3La0.57TiO3 solid state electrolyte. The results showed that ionic conductivity of Li0.3La0.57TiO3 membrane which was synthesized by firstly forming colloidal TiO2 (i.e., TiO2 sol) and then Li+ and La+ were added to the colloidal TiO2 was on the order of 10-5 S/cm. It also showed that the temperatures corresponding to a full decomposition for L0.3La0.57TiO3 is about 750°C and materials start forming perovskite structure when temperature reaches about 900°C and the lithium ionic conductivity gains about 21% increase when the pellet thickness is reduced to about ¼
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 1; 191--194
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological and operational concept of an LNG carrier
Koncepcja techniczno-eksploatacyjna gazowca LNG
Autorzy:
Bortnowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/359226.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
gaz skroplony
zbiorniki membranowe
objętość ładunkowa
siłownia okrętowa
struktura kosztów
liquefied gas
membrane tanks
cargo capacity
marine power plant
cost structure
Opis:
In connection with the current investment project of building an liquefied natural gas (LNG) terminal in Świnoujście, an analysis of design solutions and operational features of the potential variant of an LNG carrier supplying gas from the Persian Gulf areas has been conducted. As a result of studying the waterway restrictions on the assumed route, the article presents the concept of the optimum LNG carrier size - its overall dimensions - along with an analysis of design parameters. A hull shape model was used to examine the hull resistance and propulsion system. Besides, the size of the ship engine room was estimated and the power demand of the main propulsion system was determined. The cost patterns of LNG carrier construction and operation was included as well as the estimated mean value of its construction unit cost.
W związku z rozpoczętą inwestycją budowy gazoportu do obsługi skroplonego gazu ziemnego w Świnoujściu przeprowadzono analizę techniczno-eksploatacyjną potencjalnego wariantu gazowca LNG, dostarczającego gaz z obszarów Zatoki Perskiej. W wyniku przestudiowania ograniczeń drogi wodnej na założonej trasie w artykule przedstawiono koncepcję optymalnej wielkości gazowca LNG - jego wymiary wraz z analizą parametrów projektowych. Dla zamodelowanego kształtu kadłuba statku przeprowadzono wstępną analizę oporowo-napędową, oszacowano wielkość siłowni okrętowej i wyznaczono zapotrzebowaną moc napędu głównego. Zamieszczono strukturę kosztów budowy i eksploatacji gazowca LNG wraz z oszacowaniem średniej wartości jednostkowego kosztu jego budowy.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 21 (93); 28-33
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hiring cell gatekeepers – ABC transporters in plant biotechnology
Autorzy:
Szewczak, A.
Ziomkiewicz, I.
Jasinski, M.
Powiązania:
https://bibliotekanauki.pl/articles/80332.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ATP-binding cassette
catalytic activity
drought resistance
membrane transport
molecular structure
phytoremediation
plant biotechnology
plant hormone
plant physiology
secondary metabolite
transmembrane domain
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2011, 92, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of the basilar membrane vibration induced by the unsteady fluid flow in the human inner ear
Autorzy:
Wahl, Philipp
Ziegler, Pascal
Eberhard, Peter
Powiązania:
https://bibliotekanauki.pl/articles/1845019.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
human cochlea
basilar membrane
unsteady viscous fluid flow
fluid-structure interaction
pressure-displacement-based fluid element
viscous boundary layer
tonotopy
auditory threshold
ludzki ślimak
membrana podstawna
niestabilny przepływ cieczy lepkiej
interakcja płyn-struktura
element hydrauliczny oparty na ciśnieniu wyporowym
lepka warstwa graniczna
tonotopia
próg słyszalności
Opis:
For a deeper understanding of the inner ear dynamics, a Finite-Element model of the human cochlea is developed. To describe the unsteady, viscous creeping flow of the liquid, a pressure-displacement-based Finite-Element formulation is used. This allows one to efficiently compute the basilar membrane vibrations resulting from the fluid-structure interaction leading to hearing nerve stimulation. The results show the formation of a traveling wave on the basilar membrane propagating with decreasing velocity towards the peaking at a frequency dependent position. This tonotopic behavior allows the brain to distinguish between sounds of different frequencies. Additionally, not only the middle ear, but also the transfer behavior of the cochlea contributes to the frequency dependence of the auditory threshold. Furthermore, the fluid velocity and pressure fields show the effect of viscous damping forces and allow us to deeper understand the formation of the pressure difference, responsible to excite the basilar membrane.
Źródło:
Archive of Mechanical Engineering; 2020, LXVII, 4; 381-414
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies